The situational rating says what a site could do. The instability rating says what it has done and is doing: past failures and repairs, track geometry defects that keep coming back, and the cracks, bulges, seeps and voids that the engineer sees on the ground. Past movement is the best single predictor of future movement, and present movement is direct proof that the frequency index is high. The instability rating therefore governs the frequency index: it supplies the defect rating D that, with the geospatial frequency, sets the current frequency index (Table 3.8-11) at the desk and in the field.
The instability rating is assembled in two passes. The desk pass reads the railroad’s records and the public event and movement data (Section 3.8.24.1 to 3.8.24.3). The field pass is made by the EIC on site, in Blocks 2 and 3 of the report (Sections 3.8.24.4 and 3.8.24.5), and turns what is seen into the field frequency index (Section 3.8.24.6).
Continue the site history begun in Section 3.8.23.2, still oldest first, with the record of what has gone wrong:
The instability record is scored on one attribute, L6, using the same 1-to-5 convention as the situational attributes, and the defect history is scored as the defect rating D of Chapter 3.8.
| Item | Score 1 / no change | Score 3 | Score 5 / raise one level | Main sources |
|---|---|---|---|---|
| L6 Historic instability | No evidence of movement | Past repair at the site, or mapped instability nearby | Repeated documented failure, a scarp visible in lidar, or measured movement | Railroad records, lidar, landslide inventory, InSAR |
| Defect rating D | 1: no defects in the record and no indicators | 3: defects reported more than once but not returning between cycles, or indicators without progress | 5: defects returning within weeks of surfacing; standing slow order. 4: the same defect returns between surfacing cycles, or a slow order in the last 12 months (Table 3.8-10) | Track geometry exception reports, slow order history, surfacing records |
This table scores the defect rating at the desk from the records. The levels themselves, 1 None to 5 Active, are defined once in Table 3.8-10 (Section 3.8.19); where wording here differs, Table 3.8-10 governs.
Scores of 2 and 4 for L6 are described in Table 3.8-76. Defects are scored as a separate rating rather than as an attribute because they are direct evidence that the ground is moving now; they outweigh what the terrain alone suggests, so they act on the frequency index through Table 3.8-11 instead of being diluted in the average.
The preliminary frequency index combines the situational likelihood with the instability attribute. L6 carries a weight of 1 and is added to the weighted situational attributes:
L = [ Σ (wi · Li)i = 1 to 5 + L6 ] / [ Σ wi + 1 ]
Round L half up (2.5 becomes 3) to the nearest whole number, then bound it by the trigger rating to give the geospatial frequency Fg = the lesser of L and T (Equation 3.8-2). The preliminary frequency index Fp is read from Table 3.8-11 using Fg and the defect rating D scored from the railroad's records. The situational and instability contributions (LS, L6, L), T and D are kept separately so they can be seen, and printed, on the report.
On site, the instability rating is completed from what the ground and the track are showing. Block 2 of the report is a checklist of indicators, recorded separately for the left embankment, the track between the rails and the right embankment. The embankment lists are the same on both sides. The between-rails list records the track geometry defects and track structure symptoms that brought the engineer to the site.
| Left and right embankment | Between the rails |
|---|---|
| Upper slope bulge, tension crack or seepage | Reported cross level (measurement and frequency) |
| Mid-slope bulge, tension crack or seepage | Reported profile (measurement and frequency) |
| Lower slope bulge, tension crack or seepage | Reported alignment (measurement and frequency) |
| Standing water in ditch or at toe of slope | Reported warp (measurement and frequency) |
| Obstruction in ditch | Fouled ballast or water between cribs |
| Culvert dry, obstructed or damaged | Tie shift |
| Water level higher than on the opposite side | Voids between cribs |
| Erosion | Shoulder narrower than 12 in. |
Orient and walk the site. Stand on the track centerline facing up station (increasing milepost); the left embankment column is on your left and the right on your right, so “left” and “right” mean the same thing to everyone who reads the form. Walk each embankment from the top of slope to the toe, then check the ditch and toe, each culvert, the water level against the opposite embankment, and erosion. Between the rails, enter each reported defect with its measurement (the defect value, in inches, from the geometry car or track inspector) and its frequency (how often it has been reported or corrected, for example “surfaced 3 times since May”), then mark the track structure symptoms you can see. Photograph every marked indicator with a scale and the milepost in the frame, and write the photo number beside the entry.
Read the pattern, not the item. A single indicator rarely decides the case; the combination does. Typical patterns are:
Defect frequency is the best single field measure of how fast the condition is developing, and it is the main evidence for the field frequency index. Record it exactly as the railroad reports it.
Block 3 records what is failing, what will make it hard to fix, and how it is expected to fail.
| Major element | Construction constraint | Estimated failure type |
|---|---|---|
| Ballast | Access and mobility | Bearing capacity |
| Subgrade | Railroad workload conflict | Slope |
| Foreslope | Property | Settlement |
| Backslope | Material | Washout |
| Bridge abutment | Underground obstructions | Subsidence |
| Culvert | Water source | Surface erosion |
| Ditch | Permit | Stream and wave erosion |
| Adjacent property | Environmental | Underground flow erosion |
Major element is the part of the roadbed or structure whose failure threatens the track. More than one may apply; number them with the governing element as 1.
Estimated failure type is the engineer’s field judgment of the mechanism. Mark one as primary; a second may be marked as contributing. Compare it with the driving mechanism assigned at the desk (printed in the Desktop Study Summary of the report) and note any change. The exploration and analysis scoped in Block 5 confirm or revise it, and it sets which analyses are required (Section 3.8.42.8). Section 3.8.13 shows how to work from the symptom back to the mechanism.
Construction constraints are not part of the rating, but they are recorded here, while the access, the right-of-way and the utilities are in view, because they often decide which alternative is practical. Equipment access, track time (railroad workload conflict, confirmed with the railroad contact), right-of-way and adjacent property, the supply of fill and aggregate, buried utilities, a construction water source, permits and environmental restrictions can each rule out an otherwise sound fix. A toe berm that needs property the railroad does not own, or a sheet pile wall that needs a crane on a single-track main line with no work windows, is not a practical alternative.
In the field the EIC does not recompute L. The EIC confirms the trigger and T, sets the field defect rating D from the instability evidence (Table 3.8-27, which matches Table 3.8-10), and reads the current frequency index Fc from Table 3.8-11 using the geospatial frequency Fg printed on the report. Fc is the field F. The preliminary Fp is printed beside it as a check.
| Instability evidence (Blocks 2 and 3, desk record) | Field defect rating D |
|---|---|
| Active movement, settlement or erosion affecting the track now; repeated slow orders or surfacing; defects recurring faster than surfacing can hold | 5 Active |
| Fresh tension cracks or a growing bulge; geometry defects that return between surfacing cycles; the track still runs at or near normal speed | 4 Recurring |
| No sign of movement, but the conditions for it are present: water ponded against the fill, seepage, a blocked culvert, an over-steepened or eroding slope | 3 Present |
| Old scarps, past repairs or a documented failure (L6 of 3 or more), but no fresh indicators and no recurring defects | 2 Historic |
| No indicators, no instability record, or the cause has been removed | 1 None |
This table sets the defect rating in the field from what is seen. The levels themselves, 1 None to 5 Active, are defined once in Table 3.8-10 (Section 3.8.19); where wording here differs, Table 3.8-10 governs.
Where the field F differs from Fp by more than one level, write the reason on the report. Those notes are how the desktop attributes and thresholds are calibrated over time.
Continuing Example 3.8-4: the site's record of past movement and its track defects are added to its situation, first at the desk and then on the field visit.
| Variable | Value | Description |
|---|---|---|
| ΣwiLi, Σwi | 23; 6 | From Example 3.8-4 |
| Repair record | Shoulder slump repaired with fill and riprap 12 years ago | Evidence for L6 |
| Geometry record | Four cross level exceptions since the last slow order, returning between surfacing cycles | Desk evidence for D |
| T | 4 | Storm exceeding the half-blocked culvert ponds water in most wet years |
| Field findings | Seepage at mid-slope; water 3 ft higher on the left; culvert half blocked; fresh tension cracks; track at normal speed, no slow order | Field evidence for D |
L6 = 4; L = 3.86 → 4; Fg = 4; D = 4 at the desk and in the field; Fp = Fc = 4, Emerging. The desk rating predicted the field rating: the records already showed the recurring defects that the visit confirmed.
The site now has a situational severity and an instability-based frequency index. Section 3.8.25 combines them into the static rating that ranks the site under usual conditions.