The library's notes on the Mohr-Coulomb model and on drained and undrained strength cover how a set of triaxial or direct shear specimens becomes a design envelope. The common error in railroad reports is to fit c and φ to too few specimens, or to report a peak effective cohesion for a clay slope that will, over decades, soften toward zero cohesion. The calculator fits the envelope by least squares and states the fit quality so the scatter is visible.
Equation 5.2-1. Triaxial results in p-q space
Equation 5.2-2. Direct shear
| Condition | Test and strength | Railroad example |
|---|---|---|
| End of construction or rapid loading of saturated clay | UU or CU total stress: su (φ = 0) | New fill placed quickly on soft clay |
| Long term, drained | CU with pore pressure or CD: c', φ' | Cut slopes and old embankments |
| Clay slopes that have softened | Fully softened (c' ≈ 0) | Over-steepened fill slopes in fat clay |
| Pre-existing slide surface | Residual (ring or reversal shear) | Reactivated slides at a track realignment |
Three consolidated-undrained specimens with pore pressure measurement (effective σ3 of 10, 20 and 40 psi) give φ' = 29.3 deg and c' = 2.78 psi with r² = 1.000. For a long-term slope check the 2.8-psi cohesion (about 400 psf) should be justified or dropped toward the fully softened value. On a 5-ft-deep slide in a dry 2H:1V slope with this friction angle, the Chapter 6.3 calculator gives a factor of safety of 1.12 with c' = 0 and 2.79 with c' = 400 psf, so the cohesion, not the friction angle, decides the answer.
Open the shear strength calculator →
Mohr-Coulomb c and φ from triaxial (σ3, σ1) or direct shear (σn, τ) results, with Mohr circles, fit quality and strength at a design normal stress.
These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.