5.2.26 Laboratory Permeability Tests

Laboratory testing is the scientific foundation of every geotechnical design.
Authors: Daniel P. Colwell and Mario Ruel
5.2.26 Laboratory Permeability Tests

Laboratory permeability tests give the hydraulic conductivity of a specimen at a known density. Constant-head tests suit clean sands and gravels; falling-head tests suit finer sands and silts; clays need a flexible-wall permeameter (ASTM D5084). Results are corrected to 20°C because the viscosity of water changes about 2% per degree. Field values, which are controlled by layering and fissures, are usually higher; use the lab value to compare materials, design filters and check drainage layers.

5.2.26.1 Method

Equation 5.2-11. Coefficient of permeability

Constant head: k = QL/(Aht);   Falling head: k = 2.303(aL/At) log(h1/h2);   k20 = kTηT/η20

Q = volume collected in time t; h = constant head difference; a = standpipe area; h1, h2 = heads at the start and end; A, L = specimen area and length; ηT/η20 = 0.889 at 25°C, 1.135 at 15°C.

5.2.26.2 Worked example

Example 5.2-8: Constant Head Test on a Uniform Sand

A uniform sand was tested in a 6.35-cm permeameter at three heads (Das, Tables 10-2 and 10-3). The specimen’s dry mass was 726.9 g and Gs = 2.66.

L = 13.2 cmh = 60, 70, 80 cmQ in tD = 6.35 cmGivenD = 6.35 cm, L = 13.2 cmQ = 305, 375, 395 cm³ in 60 sh = 60, 70, 80 cm; T = 25 °CRequiredk at 25 °C and k20
Constant head permeameter: flow Q is collected in time t under a constant head difference h across a specimen of length L.

Given

VariableValueDescription
D, L6.35 cm; 13.2 cmA = 31.67 cm²
Q305, 375, 395 cm³ in 60 s
h60, 70, 80 cm
T25°Cη25/η20 = 0.889
Md726.9 gDry specimen

Required

  • Void ratio
  • k at 25°C and k20

Equations

  1. e = Gsρw/ρd − 1
  2. Eq. 5.2-11: k = QL/(Aht)
  3. Eq. 5.2-11: k20 = kTηT/η20

Steps

Step 1 · Void ratio
ρd = 726.9/418.0 = 1.739 g/cm³; 2.66/1.739 − 1
e = 0.53
↓
Step 2 · Runs
305(13.2)/(31.67 × 60 × 60); 375(13.2)/(31.67 × 70 × 60); 395(13.2)/(31.67 × 80 × 60)
0.0353, 0.0372, 0.0343 cm/s
Spot check: The three runs agree within 8%, so the flow stayed laminar.
↓
Step 3 · Average and correction
0.0356 × 0.889
k20 = 0.032 cm/s = 90 ft/day
Spot check: Das: average 0.035 and k20 = 0.031 cm/s; the falling-head test on the same sand gives 0.033 cm/s.
↓
Solution
k20 = 0.032 cm/s (about 90 ft/day) at e = 0.53.

Solution

The sand’s permeability is about 3 × 10−2 cm/s at 20°C, typical of a clean, uniform medium sand.

This is free-draining for a subballast or drainage blanket; check the filter criteria against the subgrade (Section 2.4.19) so fines do not migrate into it.

Open the laboratory permeability calculator →
Constant- and falling-head reductions for any number of runs, the viscosity correction to 20 °C, the specimen void ratio, k in cm/s and ft/day.

5.2.26.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

← Previous · 5.0 Testing Chapter 5.1 — In Situ Testing
Next · 5.0 Testing → Chapter 5.3 — Construction Monitoring and Field Testing