Method: Oven-dry at 230 ± 9°F for minimum 16 hours (peat and organic soils: 140°F).
Equation:
w = (M_water / M_dry) × 100%
where M_water = mass of water (mass_wet − mass_dry); M_dry = mass of dry soil.

Output: Water content w (%), dimensionless.
Minimum frequency: Every disturbed and undisturbed sample. Water content is the most fundamental test in the program — never omit it.

| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| w | water content = ( M_water / M_dry ) × 100% | Lab test | Oven-dry water content of samples (ASTM D2216); field check by microwave (D4643) or nuclear gauge (D6938). | gravels/sands 3–25%, clays 15–70% · by USCS group |
| Mdry | mass of dry soil. | Field or lab measurement | Recorded during the test or monitoring (readings, times, dimensions of the test setup). | project-specific |
Liquid Limit (LL): Casagrande cup method; flow curve plotted; LL at N = 25 blows.
Plastic Limit (PL): ⅛-in. thread rolling on glass plate.
Plasticity Index: PI = LL − PL
Liquidity Index: LI = (w − PL) / PI
Activity: A = PI / (% < 0.002 mm)
Output: LL, PL, PI (all %); LI and A dimensionless.
Minimum frequency: 1 per fine-grained stratum per boring; 1 per 5 ft depth in highly variable fine-grained profiles.
Sieve analysis (ASTM D6913): Applicable for material with particles retained on the No. 200 sieve. Sieves: 3 in., 2 in., 1½ in., 1 in., ¾ in., ½ in., No. 4, No. 10, No. 20, No. 40, No. 60, No. 100, No. 200.

Hydrometer analysis (ASTM D7928): For material passing No. 200 (clay and silt sizes). Combined with sieve for full gradation curve (ASTM D6913 + D7928).
Key outputs:
Minimum frequency: 1 per stratum per boring for classification; additional tests for filter design and liquefaction susceptibility assessment.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Cu | D₆₀ / D₁₀ (uniformity coefficient, dimensionless) | Lab test | Grain-size curve: sieve (ASTM D6913) plus hydrometer for fines (ASTM D7928). Read D10, D30, D50, D60, D85 from the curve. | by USCS group |
| Cc | D₃₀² / (D₆₀ × D₁₀) (coefficient of curvature, dimensionless) | Lab test | Grain-size curve: sieve (ASTM D6913) plus hydrometer for fines (ASTM D7928). Read D10, D30, D50, D60, D85 from the curve. | by USCS group |
Method: Pycnometer (volumetric flask) method; soil displaced volume in de-aired water.
Equation:
G_s = M_sd / (M_sd + M_pw − M_spw) (dimensionless)
where M_sd = mass of dry soil; M_pw = mass of pycnometer + water; M_spw = mass of pycnometer + soil + water.
Typical values: G_s = 2.60–2.75 (mineral soils); 2.60–2.65 (clean quartz sand); 2.70–2.80 (iron-rich soils).
Minimum frequency: 1 per soil type in each project; required for void ratio and consolidation calculations.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Gs | specific gravity of solids = M_sd / ( M_sd + M_pw − M_spw ) (dimensionless) | Lab test | Specific gravity of solids (ASTM D854). 2.65–2.70 is usually adequate for mineral soils when untested. | 2.64–2.80 mineral; lower if organic · by USCS group |
| Mpw | mass of pycnometer + water | Field or lab measurement | Recorded during the test or monitoring (readings, times, dimensions of the test setup). | project-specific |
| Mspw | mass of pycnometer + soil + water. | Field or lab measurement | Recorded during the test or monitoring (readings, times, dimensions of the test setup). | project-specific |
Standard Proctor (ASTM D698):
Modified Proctor (ASTM D1557):
Output: Compaction curve (γ_d pcf vs. w %); γ_d,max (pcf); w_opt (%)
Zero-Air-Voids (ZAV) line: γ_d,ZAV = G_s × γ_w / (1 + G_s × w/100) (pcf)
Minimum frequency: 1 Modified Proctor per borrow source or fill material type (not per sample); repeat if source changes during construction.
Method: Laboratory CBR at Modified Proctor density (95% RC minimum). Specimen soaked 96 hours at Standard loading conditions.
Penetration resistance equation:
CBR = (P_sample / P_standard) × 100%
where:
Use the higher CBR from 0.1 or 0.2 in. penetration (recheck if 0.2 in. governs).
Output: CBR (%); used directly for pavement design (Chapter 7.3, Section 7.3.1).
Minimum frequency: 1 per subgrade soil type per project; 3+ tests for intermodal yard pavement design.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| CBR | California Bearing Ratio = ( P_sample / P_standard ) × 100% | Lab or field test | Lab CBR (ASTM D1883, soaked) on compacted samples; field CBR (D4429); or from DCP (ASTM D6951) correlation. | CL/CH ≤ 15; sands 10–40; gravels 20–80 · by USCS group |
| Psample | measured force at 0.1 in | Field or lab measurement | Recorded during the test or monitoring (readings, times, dimensions of the test setup). | project-specific |
| Pstandard | standard force at same penetration | Constant | Physical constant or standard value. | project-specific |
Method: Cyclic triaxial test with conditioning sequence (500 cycles at 4 psi deviator) followed by 15 stress states per AASHTO T 307 protocol.
M_r from regression (NCHRP 1-28A model):
M_r = k₁ × P_a × (θ/P_a)^k₂ × (τ_oct/P_a + 1)^k₃ (psi)
where:
Minimum frequency: 1 test per subgrade soil type where the pavement or subgrade design uses M_r; confirm whether the owner requires it.
Repeated-load triaxial (or simple shear) tests give two results that matter for track:
Tiny plastic strains per cycle add up to large settlement over millions of cycles, so report both.
What to look for.
Test conditions. Test at the field moisture and density, including a wet-of-optimum case (Chapter 7.3). Fine-grained modulus falls steeply on the wet side.
After Selig & Waters (1994), chs. 3, 7 and 10. Full reference under Supplemental References.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Mr | resilient modulus = k₁ × P_a × (θ/ P_a )^k₂ × ( τ_oct / P_a + 1)^k₃ (psi) | Lab test (or correlation) | Repeated-load triaxial (AASHTO T 307), or Mr ≈ 2,555·CBR0.64 (MEPDG). | fine-grained 3,000–14,000 psi · by USCS group |
| Pa | atmospheric pressure = 2,117 psf = 14.7 psi | Constant | Physical constant or standard value. | project-specific |
| θ | bulk stress = σ₁ + σ₂ + σ₃ (psi) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| τoct | octahedral shear stress (psi) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |

Method A: Incremental load; load doubling each 24-hour interval; loads: 125–250–500–1,000–2,000–4,000–8,000 psf (standard); extend to 16,000 psf for deep or heavily preloaded sites.
Method B: Constant rate of strain (CRS); continuous loading at a controlled strain rate.
Key outputs (English units):
| Parameter | Symbol | Units | Equation |
|---|---|---|---|
| Compression index | C_c | dimensionless | Slope of e-log σ'_v curve (NC range) |
| Recompression index | C_r | dimensionless | Slope of e-log σ'_v curve (OC range); ≈ C_c/5 to C_c/10 |
| Preconsolidation pressure | σ'_p | tsf | Casagrande graphical construction |
| OCR | — | dimensionless | σ'_p / σ'_v0 |
| Coefficient of consolidation | c_v | ft²/day | c_v = T_v × H_dr² / t (see Chapter 6.2) |
| Secondary compression index | C_α | dimensionless | Δe / Δ log t (secondary range) |
Minimum frequency: 1 per fine-grained stratum per project; minimum 3 tests in any stratum requiring settlement analysis.
Method: Undrained shear test on undisturbed sample; three specimens at different confining pressures (typically 500, 1,000, 2,000 psf); no drainage allowed during shear.
Output: s_u (psf or tsf) from Mohr circle at failure; φ_u ≈ 0° for saturated clay.
Note: For saturated clay, UU test gives s_u directly regardless of confining pressure — the Mohr circle diameter is constant. UU is appropriate for short-term (undrained) stability analysis only.
Minimum frequency: 1 per soft or medium clay stratum per boring at critical cross-sections (slope stability, embankment loading over soft clay).


After Selig & Waters (1994), ch. 3. Full reference under Supplemental References.
Method: Specimens consolidated to two or three effective confining pressures (σ'₃); sheared undrained with pore pressure measurement; effective stress Mohr circles give c' and φ'.
Output: c' (psf), φ' (degrees) — effective strength parameters for long-term (drained) analysis.
Minimum frequency: Required for all critical slope stability analyses (Class I railroad clay shale, Class I railroad clay located in the prairies, Class I railroad sensitive marine clay); 1 set (3 specimens) per stratum per project minimum.
Method: Specimen sheared at constant normal stress; three tests at different normal stresses.
Peak and residual strength:
τ_peak = c' + σ_n × tan φ'_peak (psf)
τ_residual = σ_n × tan φ'_r (psf, c' = 0 for residual)
Output: c' (psf), φ' (degrees), φ'_r (degrees).
Use cases: Residual strength for Class I railroad clay shale and Class I railroad weathered shale slope stability; rock joint shear strength for cut slope design.
Minimum frequency: 1 per stratum requiring residual strength parameters; rock joints: minimum 3 direct shear tests per joint set per project.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| φ' | effective friction angle | Lab test (or correlation) | Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08). | sands 30–42°, clays 17–32° · by USCS group |
| c' | effective cohesion | Lab test | Effective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more. | 0–300 psf · by USCS group |

Method: Axial loading to failure at unconfined conditions (σ₃ = 0). Quick and inexpensive.
Output: q_u (psf or tsf); s_u = q_u / 2.
Limitation: UU triaxial provides more reliable s_u; unconfined compression can underestimate s_u in fissured or brittle clays. Use for screening; not for final design in critical applications.
Minimum frequency: Appropriate for routine s_u checks on Shelby tube samples; supplement with UU triaxial for design-level analysis.
Constant head (ASTM D2434): For coarse-grained soils (k above about 3 ft/day, 10⁻³ cm/s).
k = (Q × L) / (A × h × t) (ft/day)
where Q = flow volume (ft³); L = specimen length (ft); A = cross-sectional area (ft²); h = head differential (ft); t = test duration (day).
Flexible wall permeameter (ASTM D5084): For fine-grained soils (k below about 3 ft/day, 10⁻³ cm/s).
k = (a × L × ln(h₁/h₂)) / (A × t) (ft/day)
where a = standpipe area (ft²); L = specimen length (ft); h₁, h₂ = head at start and end; t = elapsed time (day).
Minimum frequency: 1 per stratum for drainage design; 3 per stratum for seepage analysis through embankments or dams.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| k | (Q × L) / (A × h × t) (ft/day) | Field or lab test | Field: pumping test, slug test (ASTM D4044, withdrawn 2024) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only. | clean sand 1–100, clay < 0.001 ft/day · by USCS group |
| L | specimen length (ft) | Test setup | Dimension of the test equipment or specimen: from the test standard or the lab/field test record. | project-specific |
| A | cross-sectional area (ft²) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| h | head differential (ft) | Field or lab measurement | Recorded during the test or monitoring (readings, times, dimensions of the test setup). | project-specific |
| t | test duration (day). | Time | Elapsed test time (recorded) or the analysis time chosen for design. | project-specific |
Method: Rock core or irregular lump loaded to failure between conical platens.
Point load strength index:
I_s = P / D_e² (psi or psf)
where P = failure load (lb); D_e = equivalent core diameter (in.).
Size-corrected index:
I_s(50) = F × I_s where F = (D_e/1.97 in.)^0.45
Estimated UCS of rock:
q_u(rock) ≈ 24 × I_s(50) (psi) [Broch & Franklin 1972; I_s in psi]
Minimum frequency: at least 10 valid tests per rock unit (ASTM D5731, withdrawn 2025); not a substitute for UCS testing for critical rock foundation designs.

| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Is | P / D_e² (psi or psf) | Lab test | Uniaxial compression of rock core (ASTM D7012); point load index (D5731) for screening. | shale 1,000–15,000; sandstone 5,000–25,000; granite 15,000–40,000 psi |
| De | equivalent core diameter (in.). | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| Is(50) | F × I_s where F = ( D_e /1.97 in.)^0.45 | Lab test | Uniaxial compression of rock core (ASTM D7012); point load index (D5731) for screening. | shale 1,000–15,000; sandstone 5,000–25,000; granite 15,000–40,000 psi |
USACE manuals (EM 1110-2-1902 slope stability, EM 1110-2-2504 sheet piles, and others cited in this manual) use letter names for the basic triaxial tests: Q = unconsolidated-undrained (UU); R = consolidated-undrained (CU); S = consolidated-drained (CD), which is also the long-term drained case. The Q test applies only to soils that are not free-draining, and R-test specimens should generally be fully saturated before shear. Errors EM 1110-2-1906 lists for R tests: back-pressure increments too large or applied too fast; chamber and back pressure not held precisely (which can overconsolidate the specimen); shearing before consolidation is complete; too fast a strain rate; temperature drift; and water absorbed from the porous inserts after the test, which biases the final water content. For S tests the main errors are strain rate and volume-change measurement. In pervious soils, water redistributes even in a quick Q test, so measure the water content of the middle third separately from the ends.

Section 5.2.3.8 gives cv = TvHdr2/t but not how t is found. The two standard curve-fitting methods (Das lab manual) are:
With double drainage, Hdr is half the average specimen height during the increment. Report which method was used. The two methods commonly give different cv values for the same increment, and the report should say which one the settlement-time analysis in Chapter 6.2 used.
Source: U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906 · Das, B. M. (2002). Soil Mechanics Laboratory Manual, 6th ed. Oxford University Press

Railroad cuts in Appalachian and prairie shales (Chapter 6.3) need durability as well as strength data, and Atterberg limits of clay shale depend on how the sample was processed. EM 1110-2-1906 therefore standardizes three preparations: blenderized (the primary reference — dried below 122°F at < 30% RH, soaked at least 48 hr, then blended as a slurry above 300% water content or twice the LL); undried (shaved directly into distilled water); and air-dried (one drying–soaking cycle). The spread among the three indicates the strength of interparticle bonds. Report which method produced the limits used for design.

Slake durability (Franklin and Chandra, 1972; ASTM D4644, withdrawn 2025): oven-dried rock lumps are rotated for 10 minutes in a sieve-mesh drum half immersed in 68°F water. Id is the percentage of the initial dry mass retained. Nagaraj reports reproducibility within 5% at 95% confidence, and the test discriminates well between mudstones that otherwise look alike.
| Id (%) | 0–25 | 25–50 | 50–75 | 75–90 | 90–95 | 95–100 |
|---|---|---|---|---|---|---|
| Durability | Very low | Low | Medium | High | Very high | Extremely high |
After Franklin and Chandra (1972). As printed in Nagaraj’s Table 9.7, the 75–90 and 90–95 labels are transposed; the order shown here is the original.
For clay shales, Nagaraj also reproduces the Morgenstern and Eigenbrod (1974) classification, which combines the amount of slaking (by the liquid limit of the slaked material: < 20 very low to > 140 very high) with the rate (change in liquidity index in the first cycle: < 0.75 slow, 0.75–1.25 fast, > 1.25 very fast). Add slake durability to the rock column of Table 5.2-1 for every cut in shale, mudstone or claystone and for any rock proposed as riprap or fill.
Source: U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906 · Nagaraj, T. S. (1993). Principles of Testing Soils, Rocks and Concrete. Elsevier (Developments in Geotechnical Engineering)

| Test | Equipment and procedure | Result |
|---|---|---|
| Deval (1896) | 11-lb sample in cylinders 8 in. dia. × 13 in., inclined 30°; 10,000 revolutions at 2,000 rev/h (about 5 h); dry or wet | Deval coefficient from % attrition. Typical minimums: > 12 (limestone), > 14 (hard rock), some railways > 16 |
| Los Angeles (1926) | Drum 28 in. dia. × 20 in.; 11-lb sample with 12 steel balls of 15 oz each; 500 revolutions at 30–33 rpm (about 15 min). EN version: 22-lb sample, 1,000 revolutions | % passing No. 12 (French) or No. 8 (British) sieve. Many specifications: LA < 25. EN reference test |
| Micro-Deval | 1.1 lb of ⅜–½ in. gravel with 11 lb of small steel balls (about ⅜ in.) and 2.6 qt of water in an 8-in. cylinder; 12,000 revolutions at 100 rpm. EN version: 22 lb, 14,000 revolutions | MDE = % finer than No. 12. Used mainly for subballast; subballast MDE < 15–20 |

North American ballast specifications (AREMA Chapter 1) use the ASTM Los Angeles test for large coarse aggregate (ASTM C535). Results from the European methods are not interchangeable with ASTM results without correlation.
Cyclic behavior. Ballast takes a large permanent set on first loading as stones rearrange, then accumulates strain slowly: εN = ε1(1 + c·log N), with c ≈ 0.2 (European ORE and British Rail research) or 0.25–0.40 (American research). On that basis it takes 100,000–300,000 cycles to double the first-cycle plastic strain. Ballast modulus roughly doubles over the first 1,000 cycles and then stays nearly constant; gravel subballast modulus does not change with cycles. Repeated-load triaxial programs should run long enough to get past this initial bedding-in.

After Profillidis (2014), §12.3–12.4, Eq. 12.1, Figs. 12.3–12.4. Full reference under Supplemental References.
| Test | Standard | What it gives |
|---|---|---|
| Atterberg limits | ASTM D4318 | Liquid limit, plastic limit, plasticity index; classifies fines |
| Particle-size distribution | ASTM D6913 (sieve), D7928 (hydrometer) | Sieve gradation, % finer than No. 200, hydrometer split of silt and clay |
| Moisture content | ASTM D2216 (oven); D4643 (microwave, for quick checks) | Water content by drying |
| Unconfined compressive strength | ASTM D2166 | Direct strength of cohesive samples |
| Proctor compaction | ASTM D698 / D1557 | Target density and optimum moisture for fill and subgrade |





Compaction can roughly double a soil’s strength. The fines content of granular fill controls its drainage, frost susceptibility and strength after rain, so specify and test fines on ballast and sub-ballast deliveries rather than accepting material that only looks good dry.
After Geotechnology for Railroaders Program, Module 2; §09–10. Full reference under Supplemental References.
Case study: 5.2.16.1 Curing time changes compaction and CBR results (Look 2023), in Section 5.2.16 Case Studies.