↑ Parent Menu⌂ Main Menu
← Railway Ground Hazard Risk Management
GHRM
Railway Ground Hazard Risk Management · 5.0 · Testing
Sections · click a car to open it

Chapter 5.2 — Laboratory Testing Program

Laboratory testing is the scientific foundation of every geotechnical design.
Authors: Daniel P. Colwell and Mario Ruel

Geotechnical Services Manual for Railroad Clients

A Consultant's Reference for Delivering Geotechnical Engineering Services Across North American Railroad Capital Programs

Soil & Rock Properties and Laboratory Testing Database

Typical values and ranges for soil and rock properties, typical laboratory results, ASTM precision (acceptable range of two results), and a catalog of the laboratory and field tests in this chapter with their standards, specimen requirements and design uses. English units, with source, table and page for every value.

Laboratory tests catalog  ·  Typical values and ranges  ·  Download Excel

Typical Values for This Chapter — from the GHRM Soil & Rock Properties Database

Typical laboratory results and ASTM precision for reviewing test data. English units; every value cites its library source, table and page. For preliminary design and checking test results, not a substitute for site testing.

Typical laboratory test results (30 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Natural water content (saturated)Loose uniform sandSaturated, natural2527.530%DAS T2-3, p.12
Natural water content (saturated)Dense uniform sandSaturated, natural121416%DAS T2-3, p.12
Natural water content (saturated)Loose angular-grained silty sandSaturated, natural25%DAS T2-3, p.12
Natural water content (saturated)Dense angular-grained silty sandSaturated, natural15%DAS T2-3, p.12
Natural water content (saturated)Stiff claySaturated, natural20%DAS T2-3, p.12
Natural water content (saturated)Soft claySaturated, natural304050%DAS T2-3, p.12
Natural water content (saturated)Soft organic claySaturated, natural80105130%DAS T2-3, p.12
Natural water content (saturated)Glacial tillSaturated, natural10%DAS T2-3, p.12
Specific gravity of soil solidsSandSW-SP2.632.652.67–DAS T3-1, p.14
Specific gravity of soil solidsSiltsML-MH2.652.6752.7–DAS T3-1, p.14
Specific gravity of soil solidsClay and silty clayCL-CH2.672.7852.9–DAS T3-1, p.14
Specific gravity of soil solidsOrganic soilOL / OH / Pt2–DAS T3-1, p.14
Plasticity index of clay mineralKaoliniteClay mineral203040%DAS ch. 7 comments, p.45
Plasticity index of clay mineralIlliteClay mineral3542.550%DAS ch. 7 comments, p.45
Plasticity index of clay mineralMontmorilloniteClay mineral5075100%DAS ch. 7 comments, p.45
Drained friction angle (direct shear)Round-grained sandSP-SWLoose283032degDAS ch. 15 comments, p.98
Drained friction angle (direct shear)Round-grained sandSP-SWMedium3032.535degDAS ch. 15 comments, p.98
Drained friction angle (direct shear)Round-grained sandSP-SWDense343638degDAS ch. 15 comments, p.98
Drained friction angle (direct shear)Angular-grained sandSP-SWLoose303336degDAS ch. 15 comments, p.98
Drained friction angle (direct shear)Angular-grained sandSP-SWMedium343740degDAS ch. 15 comments, p.98
Drained friction angle (direct shear)Angular-grained sandSP-SWDense4042.545degDAS ch. 15 comments, p.98
Pore pressure parameter at failureClays with high sensitivityCL-CHTriaxial (CU with pore pressure)0.751.1251.5–DAS ch. 18 comments, p.134
Pore pressure parameter at failureNormally consolidated claysCL-CHTriaxial (CU with pore pressure)0.50.751–DAS ch. 18 comments, p.134
Pore pressure parameter at failureOverconsolidated claysCL-CHTriaxial (CU with pore pressure)-0.5-0.250–DAS ch. 18 comments, p.134
Pore pressure parameter at failureCompacted sandy clayCL-CHTriaxial (CU with pore pressure)0.50.6250.75–DAS ch. 18 comments, p.134
Expansion indexCompacted fine-grained soilCL-CH / MHVery low expansion potential01020–D4829-19 T1, p.2
Expansion indexCompacted fine-grained soilCL-CH / MHLow expansion potential2135.550–D4829-19 T1, p.2
Expansion indexCompacted fine-grained soilCL-CH / MHMedium expansion potential5170.590–D4829-19 T1, p.2
Expansion indexCompacted fine-grained soilCL-CH / MHHigh expansion potential91110.5130–D4829-19 T1, p.2
Expansion indexCompacted fine-grained soilCL-CH / MHVery high expansion potential130–D4829-19 T1, p.2
Open this set in the database ↗
ASTM precision – acceptable range of two results (60 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Liquid limit – acceptable range of two resultsASTM reference soilCHSingle operator (repeatability)2% pointsD4318-17e1 T2, p.13
Plastic limit – acceptable range of two resultsASTM reference soilCHSingle operator (repeatability)1% pointsD4318-17e1 T2, p.13
Plasticity index – acceptable range of two resultsASTM reference soilCHSingle operator (repeatability)2% pointsD4318-17e1 T2, p.13
Liquid limit – acceptable range of two resultsASTM reference soilCLSingle operator (repeatability)1% pointsD4318-17e1 T2, p.13
Plastic limit – acceptable range of two resultsASTM reference soilCLSingle operator (repeatability)1% pointsD4318-17e1 T2, p.13
Plasticity index – acceptable range of two resultsASTM reference soilCLSingle operator (repeatability)1% pointsD4318-17e1 T2, p.13
Liquid limit – acceptable range of two resultsASTM reference soilMLSingle operator (repeatability)2% pointsD4318-17e1 T2, p.13
Plastic limit – acceptable range of two resultsASTM reference soilMLSingle operator (repeatability)1% pointsD4318-17e1 T2, p.13
Plasticity index – acceptable range of two resultsASTM reference soilMLSingle operator (repeatability)2% pointsD4318-17e1 T2, p.13
Liquid limit – acceptable range of two resultsASTM reference soilCHMultilaboratory (reproducibility)4% pointsD4318-17e1 T2, p.13
Plastic limit – acceptable range of two resultsASTM reference soilCHMultilaboratory (reproducibility)6% pointsD4318-17e1 T2, p.13
Plasticity index – acceptable range of two resultsASTM reference soilCHMultilaboratory (reproducibility)7% pointsD4318-17e1 T2, p.13
Liquid limit – acceptable range of two resultsASTM reference soilCLMultilaboratory (reproducibility)3% pointsD4318-17e1 T2, p.13
Plastic limit – acceptable range of two resultsASTM reference soilCLMultilaboratory (reproducibility)3% pointsD4318-17e1 T2, p.13
Plasticity index – acceptable range of two resultsASTM reference soilCLMultilaboratory (reproducibility)5% pointsD4318-17e1 T2, p.13
Liquid limit – acceptable range of two resultsASTM reference soilMLMultilaboratory (reproducibility)4% pointsD4318-17e1 T2, p.13
Plastic limit – acceptable range of two resultsASTM reference soilMLMultilaboratory (reproducibility)3% pointsD4318-17e1 T2, p.13
Plasticity index – acceptable range of two resultsASTM reference soilMLMultilaboratory (reproducibility)5% pointsD4318-17e1 T2, p.13
Specific gravity – acceptable range of two resultsASTM reference soilCHSingle operator (repeatability)0.03–D854-14 T3, p.7
Specific gravity – acceptable range of two resultsASTM reference soilCLSingle operator (repeatability)0.02–D854-14 T3, p.7
Specific gravity – acceptable range of two resultsASTM reference soilMLSingle operator (repeatability)0.02–D854-14 T3, p.7
Specific gravity – acceptable range of two resultsASTM reference soilSPSingle operator (repeatability)0.02–D854-14 T3, p.7
Specific gravity – acceptable range of two resultsASTM reference soilCHMultilaboratory (reproducibility)0.08–D854-14 T3, p.7
Specific gravity – acceptable range of two resultsASTM reference soilCLMultilaboratory (reproducibility)0.06–D854-14 T3, p.7
Specific gravity – acceptable range of two resultsASTM reference soilMLMultilaboratory (reproducibility)0.06–D854-14 T3, p.7
Specific gravity – acceptable range of two resultsASTM reference soilSPMultilaboratory (reproducibility)0.02–D854-14 T3, p.7
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilCHSingle operator (repeatability)0.4% pointsD1140-17 T2, p.5
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilCLSingle operator (repeatability)0.4% pointsD1140-17 T2, p.5
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilMLSingle operator (repeatability)0.3% pointsD1140-17 T2, p.5
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilSPSingle operator (repeatability)0.5% pointsD1140-17 T2, p.5
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilCHMultilaboratory (reproducibility)0.6% pointsD1140-17 T2, p.5
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilCLMultilaboratory (reproducibility)1.1% pointsD1140-17 T2, p.5
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilMLMultilaboratory (reproducibility)0.4% pointsD1140-17 T2, p.5
Percent fines (No. 200 wash) – acceptable range of two resultsASTM reference soilSPMultilaboratory (reproducibility)1% pointsD1140-17 T2, p.5
Maximum dry unit weight, standard effort – acceptable range of two resultsASTM reference soilCHSingle operator (repeatability)1.3pcfD698-12e2 T3, p.10
Optimum water content, standard effort – acceptable range of two resultsASTM reference soilCHSingle operator (repeatability)0.7% pointsD698-12e2 T3, p.10
Maximum dry unit weight, standard effort – acceptable range of two resultsASTM reference soilCLSingle operator (repeatability)1.2pcfD698-12e2 T3, p.10
Optimum water content, standard effort – acceptable range of two resultsASTM reference soilCLSingle operator (repeatability)0.9% pointsD698-12e2 T3, p.10
Maximum dry unit weight, standard effort – acceptable range of two resultsASTM reference soilMLSingle operator (repeatability)1.3pcfD698-12e2 T3, p.10
Optimum water content, standard effort – acceptable range of two resultsASTM reference soilMLSingle operator (repeatability)0.9% pointsD698-12e2 T3, p.10
Maximum dry unit weight, standard effort – acceptable range of two resultsASTM reference soilCHMultilaboratory (reproducibility)3.9pcfD698-12e2 T3, p.10
Optimum water content, standard effort – acceptable range of two resultsASTM reference soilCHMultilaboratory (reproducibility)1.8% pointsD698-12e2 T3, p.10
Maximum dry unit weight, standard effort – acceptable range of two resultsASTM reference soilCLMultilaboratory (reproducibility)2.3pcfD698-12e2 T3, p.10
Optimum water content, standard effort – acceptable range of two resultsASTM reference soilCLMultilaboratory (reproducibility)1.5% pointsD698-12e2 T3, p.10
Maximum dry unit weight, standard effort – acceptable range of two resultsASTM reference soilMLMultilaboratory (reproducibility)1.6pcfD698-12e2 T3, p.10
Optimum water content, standard effort – acceptable range of two resultsASTM reference soilMLMultilaboratory (reproducibility)1.3% pointsD698-12e2 T3, p.10
Maximum dry unit weight, modified effort – acceptable range of two resultsLean clay with sand / sandy lean clay (AMRL samples)CLSingle operator (repeatability)1.8pcfD1557-12e1 T3, p.11
Optimum water content, modified effort – acceptable range of two resultsLean clay with sand / sandy lean clay (AMRL samples)CLSingle operator (repeatability)1% pointsD1557-12e1 T3, p.11
Maximum dry unit weight, modified effort – acceptable range of two resultsLean clay with sand / sandy lean clay (AMRL samples)CLMultilaboratory (reproducibility)4.4pcfD1557-12e1 T3, p.11
Optimum water content, modified effort – acceptable range of two resultsLean clay with sand / sandy lean clay (AMRL samples)CLMultilaboratory (reproducibility)2.1% pointsD1557-12e1 T3, p.11
CBR – coefficient of variation, single operatorLaboratory-compacted soilCompacted per D6988.2%D1883-16 T12.1, p.10
CBR – coefficient of variation, single operatorLaboratory-compacted soilCompacted per D15575.9%D1883-16 T12.1, p.10
Sand equivalent – single-operator standard deviationGranular soil / fine aggregateSE > 801.5SE unitsD2419-14 T13.1.1, p.9
Sand equivalent – single-operator standard deviationGranular soil / fine aggregateSE < 802.9SE unitsD2419-14 T13.1.1, p.9
Nuclear gauge wet density – 95% repeatability limitASTM reference soilMLDirect transmission1.3pcfD6938-17a T1, p.6
Nuclear gauge wet density – 95% reproducibility limitASTM reference soilMLDirect transmission2.1pcfD6938-17a T1, p.6
Nuclear gauge wet density – 95% repeatability limitASTM reference soilCLDirect transmission0.9pcfD6938-17a T1, p.6
Nuclear gauge wet density – 95% reproducibility limitASTM reference soilCLDirect transmission1.9pcfD6938-17a T1, p.6
Nuclear gauge wet density – 95% repeatability limitASTM reference soilSPDirect transmission0.7pcfD6938-17a T1, p.6
Nuclear gauge wet density – 95% reproducibility limitASTM reference soilSPDirect transmission1.9pcfD6938-17a T1, p.6
Open this set in the database ↗
Laboratory measurement error (COV) (13 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Coefficient of variation – lab measurement errorClay, silt – Undrained strength, triaxial compression su(TC)CL-MLPhoon & Kulhawy (1999a)81938%FGE T31.4, p.480
Coefficient of variation – lab measurement errorClay, silt – Undrained strength, direct shear su(DS)CL-MLPhoon & Kulhawy (1999a)192020%FGE T31.4, p.480
Coefficient of variation – lab measurement errorClay – Undrained strength, lab vane su(LV)CL-CHPhoon & Kulhawy (1999a)51337%FGE T31.4, p.480
Coefficient of variation – lab measurement errorClay, silt – Friction angle, triaxial φ′(TC)CL-MLPhoon & Kulhawy (1999a)72456%FGE T31.4, p.480
Coefficient of variation – lab measurement errorClay, silt – Friction angle, direct shear φ′(DS)CL-MLPhoon & Kulhawy (1999a)31329%FGE T31.4, p.480
Coefficient of variation – lab measurement errorSand – Friction angle, direct shear φ′(DS)SW-SMPhoon & Kulhawy (1999a)131414%FGE T31.4, p.480
Coefficient of variation – lab measurement errorSand, silt – tan φ′, triaxialSM-MLPhoon & Kulhawy (1999a)2822%FGE T31.4, p.480
Coefficient of variation – lab measurement errorClay – tan φ′, direct shearCL-CHPhoon & Kulhawy (1999a)61422%FGE T31.4, p.480
Coefficient of variation – lab measurement errorFine-grained soils – Natural moisture content wnML-CHPhoon & Kulhawy (1999a)6812%FGE T31.4, p.480
Coefficient of variation – lab measurement errorFine-grained soils – Liquid limit wLML-CHPhoon & Kulhawy (1999a)3711%FGE T31.4, p.480
Coefficient of variation – lab measurement errorFine-grained soils – Plastic limit wPML-CHPhoon & Kulhawy (1999a)71018%FGE T31.4, p.480
Coefficient of variation – lab measurement errorFine-grained soils – Plasticity index PIML-CHPhoon & Kulhawy (1999a)52451%FGE T31.4, p.480
Coefficient of variation – lab measurement errorFine-grained soils – Total unit weight γML-CHPhoon & Kulhawy (1999a)112%FGE T31.4, p.480
Open this set in the database ↗
Ballast and subballast acceptance limits (32 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Ballast – material passing No. 200 sieveBallast – Granite and traprockAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – material passing No. 200 sieveBallast – QuartziteAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – material passing No. 200 sieveBallast – LimestoneAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – material passing No. 200 sieveBallast – Dolomitic limestoneAREMA limit (max); ASTM C1171%AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – Granite and traprockAREMA limit (min); ASTM C1272.6–AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – QuartziteAREMA limit (min); ASTM C1272.6–AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – LimestoneAREMA limit (min); ASTM C1272.6–AREMA19 T1-2-1, p.1-2-11
Ballast – bulk specific gravityBallast – Dolomitic limestoneAREMA limit (min); ASTM C1272.65–AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – Granite and traprockAREMA limit (max); ASTM C1271%AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – QuartziteAREMA limit (max); ASTM C1271%AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – LimestoneAREMA limit (max); ASTM C1272%AREMA19 T1-2-1, p.1-2-11
Ballast – absorptionBallast – Dolomitic limestoneAREMA limit (max); ASTM C1272%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – Granite and traprockAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – QuartziteAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – LimestoneAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – clay lumps and friable particlesBallast – Dolomitic limestoneAREMA limit (max); ASTM C1420.5%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – Granite and traprockAREMA limit (max); ASTM C535 or C13135%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – QuartziteAREMA limit (max); ASTM C535 or C13130%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – LimestoneAREMA limit (max); ASTM C535 or C13130%AREMA19 T1-2-1, p.1-2-11
Ballast – Los Angeles abrasion loss (LAA)Ballast – Dolomitic limestoneAREMA limit (max); ASTM C535 or C13130%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – Granite and traprockAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – QuartziteAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – LimestoneAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – sodium sulfate soundness, 5 cyclesBallast – Dolomitic limestoneAREMA limit (max); ASTM C885%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – Granite and traprockAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – QuartziteAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – LimestoneAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Ballast – flat or elongated particlesBallast – Dolomitic limestoneAREMA limit (max); ASTM D4791 Method A5%AREMA19 T1-2-1, p.1-2-11
Subballast lateral stress ratioSubballast0.40.71–LI16 T3.8, p.105
Subballast fines (passing No. 200)SubballastAREMA maximum5%AREMA19 text, p.1-2-25
Subballast LA abrasion lossSubballastReasonable acceptance limit50%LI16 text, p.105
Subballast sodium sulfate soundness lossSubballastReasonable acceptance limit5%LI16 text, p.105
Open this set in the database ↗
References (16)
  1. AREMA19 – AREMA (2019). Manual for Railway Engineering, Chapter 1 – Roadway and Ballast. American Railway Engineering and Maintenance-of-Way Association.
  2. CB – Carter, M. & Bentley, S.P. (2016). Soil Properties and their Correlations, 2nd ed. Wiley.
  3. D1140-25 – ASTM D1140-25, Amount of Material in Soils Finer than the No. 200 (75-μm) Sieve.
  4. D1557-12(2021) – ASTM D1557-12(2021), Laboratory Compaction Characteristics of Soil Using Modified Effort.
  5. D1883-21 – ASTM D1883-21, California Bearing Ratio (CBR) of Laboratory-Compacted Soils.
  6. D2419-22 – ASTM D2419-22, Sand Equivalent Value of Soils and Fine Aggregate.
  7. D4318-17e1 – ASTM D4318-17e1, Liquid Limit, Plastic Limit, and Plasticity Index of Soils.
  8. D4829-21 – ASTM D4829-21, Expansion Index of Soils.
  9. D6938-23 – ASTM D6938-23, In-Place Density and Water Content of Soil by Nuclear Methods.
  10. D698-12(2021) – ASTM D698-12(2021), Laboratory Compaction Characteristics of Soil Using Standard Effort.
  11. D854-23 – ASTM D854-23, Specific Gravity of Soil Solids by Water Pycnometer.
  12. DAS – Das, B.M. (2002). Soil Mechanics Laboratory Manual, 6th ed. Oxford University Press.
  13. FGE – Rao, V.V.S. & Sivakumar Babu, G.L., eds. (2016). Forensic Geotechnical Engineering. Developments in Geotechnical Engineering. Springer India.
  14. LI16 – Li, D., Hyslip, J., Sussmann, T. & Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis.
  15. LOOK – Look, B.G. (2007). Handbook of Geotechnical Investigation and Design Tables. Taylor & Francis.
  16. USACE – U.S. Army Corps of Engineers (1990). EM 1110-1-1904, Settlement Analysis.
Correlations (10)
EstimateCorrelationLimits / notesSource
Compression index – claysCc = 0.009 (LL − 10) (organic soils, sensitivity < 4)Skempton / Terzaghi & PeckUSACE 3-7, p.59
Compression index – claysCc = 1.15 (e0 − 0.35); Cc = 0.012 wn; Cc = 0.01 (LL − 13)All claysUSACE 3-7, p.59
Compression index – organic soils, peatCc = 0.0115 wnwn in percentUSACE 3-7, p.59
Compression index – varved claysCc = (1 + e0) [0.1 + 0.006 (wn − 25)]USACE 3-7, p.59
Compression index – remolded claysCc = 0.007 (LL − 7)Azzouz et al. (1976)CB 5.2, p.109
Compression index – inorganic silt/clayCc = 0.30 (e0 − 0.27); Cc = 0.75 (e0 − 0.5)Azzouz et al. (1976)CB 5.2, p.109
Recompression indexCr ≈ 0.05–0.10 Cc (range 0.015–0.35)Roscoe et al. (1958)CB 5.1 text, p.108
Secondary compression indexCα ≈ 0.0001 wn (10 < wn < 3000%)NAVFAC DM 7.1USACE 3-14 text, p.79
Plasticity index from linear shrinkagePI ≈ 2.13 LSUse where PL and LL are difficultLOOK 2.12, p.49
Liquidity and consistency indexLI = (w − PL)/PI; CI = (LL − w)/PICB Eq. 6.15–6.16, p.145
All correlations ↗

Full database  ·  Laboratory tests  ·  Download Excel  ·  Library documents for this chapter  ·  Calculators for this chapter

Further reading — ICE Manual of Geotechnical Engineering
The chapters below cover the same ground in more depth. They are cited, not reproduced; see Appendix G for the full cross-reference and edition notes.
5.2.0 Executive Summary

Laboratory testing is the scientific foundation of every geotechnical design. Field observations classify soils and rock; laboratory tests quantify the engineering properties that drive bearing capacity, settlement, slope stability, and pavement design calculations. For railroad capital projects, the consequences of poorly selected or inadequately executed lab programs are magnified by the scale of the loading environment — 286,000-lb gross rail load, cyclic dynamic amplification, and serviceability tolerances measured in fractions of an inch.

This chapter defines the laboratory testing program for geotechnical investigations serving owner railroads. It covers test selection by project type, ASTM standards for every test method, sample handling and chain of custody, laboratory QA/QC, turnaround time expectations by client, and accreditation requirements. All test results are expressed in English units throughout. The consultant must confirm current ASTM edition requirements with each client's engineering standards before mobilizing a laboratory program — clients periodically update their referenced editions.

Empirical Equations — Use and Limitations

The correlations used in this chapter are listed below. Each gives an estimate, not a test result. The full equation, variables, range of applicability, constraints and source for each one, and the note to record whenever one is used, are in the Empirical Equations & Correlations reference.

IDCorrelationGives
RK-10UCS from point load indexσ꜀
IX-01Compression index from liquid limit (undisturbed)C꜀
IX-02Compression index from liquid limit (remolded)C꜀
IX-03Compression index from void ratioC꜀
IX-04Compression index from plasticity indexC꜀
IX-05Secondary compression ratioC_α
IX-06Normalized undrained strength from plasticitySᵤ/σ'
IX-08Friction angle of NC clay from plasticityφ'
IX-10Undrained strength from liquidity indexSᵤ (remolded)
IX-11Hazen hydraulic conductivityk
IX-13Small-strain shear modulus (Hardin)G_max
5.2.1 Background and Railroad Context

The laboratory testing program for a railroad geotechnical investigation must be:

  1. Purposeful. Every test must serve a defined analytical need. Ordering triaxial shear strength tests for a track subgrade investigation without a slope stability analysis to use them wastes budget and delays the schedule. Order only what the analysis matrix demands.
  2. Sufficient. Under-testing is the more common and more dangerous failure mode. A single consolidation test in a soft clay stratum extending over 500 ft is not statistically defensible. A minimum of one test per identified stratum per project segment, plus additional tests where variability is observed, is a reasonable minimum; confirm the owner railroad's expectations.
  3. QA-verified. Owner railroads that maintain laboratory accreditation requirements (see Section 5.2.8) will reject data produced by non-accredited laboratories. Confirm accreditation before awarding the laboratory subcontract.
5.2.2 Test Program Design by Project Type
Table 5.2-1. Laboratory Testing Matrix by Railroad Project Type
TestSiding/Track Ext.Intermodal YardBridge/CulvertMainline RehabEmergency
Moisture content (D2216)All samplesAll samplesAll samplesAll samplesAll samples
Atterberg limits (D4318)Fine-grainedFine-grainedFine-grainedFine-grainedFine-grained
Grain size (D6913/D7928)SelectSelectSelectSelectPriority
Specific gravity (D854)Consolidation setAll triaxial setAll triaxial setConsolidation setPriority
Standard Proctor (D698)Structure backfillAs neededStructure backfillAs neededNot typically
Modified Proctor (D1557)EmbankmentYesEmbankmentYesNot typically
CBR (D1883)SubgradePavement designNot typicallySubgrade rehabNot typically
Resilient Modulus (T307)SubgradePavement designNot typicallySubgrade rehabNot typically
Consolidation (D2435)Soft claySoft claySoft claySoft clayNot typically
UU Triaxial (D2850)Not typicallySlope stabilitySlope stabilitySlope stabilityQuick stability
CU Triaxial (D4767)Not typicallyCritical slopesCritical slopesCritical slopesNot typically
Direct shear (D3080)Not typicallyResidual φ'Rock jointsResidual φ'Not typically
Unconfined compression (D2166)Not typicallySelectSelectSelectQuick s_u
Permeability (D2434/D5084)Drainage designDrainage designDrainage designDrainage designNot typically
Point load index (D5731)Rock cutsRock cutsRock cutsRock cutsNot typically
Sodium sulfate soundnessBallastBallastNot typicallyBallast rehabNot typically
LA Abrasion (C131)BallastBallastNot typicallyBallast rehabNot typically
Rock Tests
Rock Tests

Ballast, subballast and fouling test suite

For ballast-source qualification, ballast condition surveys and subballast design, add the following to the soil program:

Tests for Soil
Tests for Soil
  • Ballast source: petrographic analysis; LA Abrasion; Mill Abrasion (wet) and the Abrasion Number, AN = LAA + 5 MA; wet attrition (Deval) for soft stone in wet track; clay lumps and friable particles (ASTM C142); flat and elongated particles; specific gravity and absorption.
  • Fouled ballast: trench samples taken by zone (crib, shoulder, top, bottom). Report the fraction finer than 3/8 in. as fouling material and the fraction finer than No. 200 as fines. Compute the fouling index, and identify the source of the fines by color, plasticity and, where it matters, SEM or XRD mineralogy.
  • Subballast: gradation for the filter checks against both ballast and subgrade; LA Abrasion ≤ 50; LL and PI on the minus-No. 40 fraction (≤ 25 and ≤ 6).

After Selig & Waters (1994), chs. 7, 8 and 9. Full reference under Supplemental References.

Empirical equation note · this section

Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.

  • RK-10 UCS from point load index σ꜀Use: Hard, isotropic rock; quick strength index in field. Limits: K varies widely with rock type and anisotropy; calibrate with lab UCS. Unreliable in weak rock (σc < ~3,600 psi).
5.2.3 Test Methods — ASTM Standards and English Unit Outputs
5.2.3.1 Water Content (ASTM D2216)

Method: Oven-dry at 230 ± 9°F for minimum 16 hours (peat and organic soils: 140°F).

Equation:

w = (M_water / M_dry) × 100%

where M_water = mass of water (mass_wet − mass_dry); M_dry = mass of dry soil.

Soil Index Properties
Soil Index Properties

Output: Water content w (%), dimensionless.

Minimum frequency: Every disturbed and undisturbed sample. Water content is the most fundamental test in the program — never omit it.

Water Content Test
Water Content Test
Inputs for the equations in this section (2)
SymbolWhat it isComes fromHow to get itTypical range
wwater content = ( M_water / M_dry ) × 100%Lab testOven-dry water content of samples (ASTM D2216); field check by microwave (D4643) or nuclear gauge (D6938).gravels/sands 3–25%, clays 15–70% · by USCS group
Mdrymass of dry soil.Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
5.2.3.2 Atterberg Limits (ASTM D4318)

Liquid Limit (LL): Casagrande cup method; flow curve plotted; LL at N = 25 blows.

Plastic Limit (PL): ⅛-in. thread rolling on glass plate.

Plasticity Index: PI = LL − PL

Liquidity Index: LI = (w − PL) / PI

Activity: A = PI / (% < 0.002 mm)

Output: LL, PL, PI (all %); LI and A dimensionless.

Minimum frequency: 1 per fine-grained stratum per boring; 1 per 5 ft depth in highly variable fine-grained profiles.

5.2.3.3 Grain Size Analysis

Sieve analysis (ASTM D6913): Applicable for material with particles retained on the No. 200 sieve. Sieves: 3 in., 2 in., 1½ in., 1 in., ¾ in., ½ in., No. 4, No. 10, No. 20, No. 40, No. 60, No. 100, No. 200.

Sieve Analysis Test
Sieve Analysis Test

Hydrometer analysis (ASTM D7928): For material passing No. 200 (clay and silt sizes). Combined with sieve for full gradation curve (ASTM D6913 + D7928).

Hydrometer Analysis
Hydrometer Analysis

Key outputs:

  • D₁₀, D₃₀, D₆₀ (in., or mm for reference): particle diameters at 10%, 30%, 60% passing
  • C_u = D₆₀ / D₁₀ (uniformity coefficient, dimensionless)
  • C_c = D₃₀² / (D₆₀ × D₁₀) (coefficient of curvature, dimensionless)
  • Fines content: % passing No. 200 sieve

Minimum frequency: 1 per stratum per boring for classification; additional tests for filter design and liquefaction susceptibility assessment.

Inputs for the equations in this section (2)
SymbolWhat it isComes fromHow to get itTypical range
CuD₆₀ / D₁₀ (uniformity coefficient, dimensionless)Lab testGrain-size curve: sieve (ASTM D6913) plus hydrometer for fines (ASTM D7928). Read D10, D30, D50, D60, D85 from the curve.by USCS group
CcD₃₀² / (D₆₀ × D₁₀) (coefficient of curvature, dimensionless)Lab testGrain-size curve: sieve (ASTM D6913) plus hydrometer for fines (ASTM D7928). Read D10, D30, D50, D60, D85 from the curve.by USCS group
5.2.3.4 Specific Gravity (ASTM D854)

Method: Pycnometer (volumetric flask) method; soil displaced volume in de-aired water.

Equation:

G_s = M_sd / (M_sd + M_pw − M_spw) (dimensionless)

where M_sd = mass of dry soil; M_pw = mass of pycnometer + water; M_spw = mass of pycnometer + soil + water.

Typical values: G_s = 2.60–2.75 (mineral soils); 2.60–2.65 (clean quartz sand); 2.70–2.80 (iron-rich soils).

Minimum frequency: 1 per soil type in each project; required for void ratio and consolidation calculations.

Why Soil Consolidation Happens
Why Soil Consolidation Happens
Soil Consolidation Testing
Soil Consolidation Testing
Inputs for the equations in this section (3)
SymbolWhat it isComes fromHow to get itTypical range
Gsspecific gravity of solids = M_sd / ( M_sd + M_pw − M_spw ) (dimensionless)Lab testSpecific gravity of solids (ASTM D854). 2.65–2.70 is usually adequate for mineral soils when untested.2.64–2.80 mineral; lower if organic · by USCS group
Mpwmass of pycnometer + waterField or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Mspwmass of pycnometer + soil + water.Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
5.2.3.5 Compaction Tests

Standard Proctor (ASTM D698):

  • Method A: material passing No. 4 sieve; 3 layers; 25 blows per layer; 5.5-lb hammer; 12-in. drop
  • Energy: 12,375 ft·lb/ft³

Modified Proctor (ASTM D1557):

  • Method A or C: 5 layers; 25 blows per layer; 10-lb hammer; 18-in. drop
  • Energy: 56,250 ft·lb/ft³

Output: Compaction curve (γ_d pcf vs. w %); γ_d,max (pcf); w_opt (%)

Zero-Air-Voids (ZAV) line: γ_d,ZAV = G_s × γ_w / (1 + G_s × w/100) (pcf)

Minimum frequency: 1 Modified Proctor per borrow source or fill material type (not per sample); repeat if source changes during construction.

5.2.3.6 California Bearing Ratio (ASTM D1883)

Method: Laboratory CBR at Modified Proctor density (95% RC minimum). Specimen soaked 96 hours at Standard loading conditions.

Penetration resistance equation:

CBR = (P_sample / P_standard) × 100%

where:

  • P_sample = measured force at 0.1 in. or 0.2 in. penetration (lb)
  • P_standard = standard force at same penetration; 0.1 in.: 3,000 lb; 0.2 in.: 4,500 lb

Use the higher CBR from 0.1 or 0.2 in. penetration (recheck if 0.2 in. governs).

Output: CBR (%); used directly for pavement design (Chapter 7.3, Section 7.3.1).

Minimum frequency: 1 per subgrade soil type per project; 3+ tests for intermodal yard pavement design.

Inputs for the equations in this section (3)
SymbolWhat it isComes fromHow to get itTypical range
CBRCalifornia Bearing Ratio = ( P_sample / P_standard ) × 100%Lab or field testLab CBR (ASTM D1883, soaked) on compacted samples; field CBR (D4429); or from DCP (ASTM D6951) correlation.CL/CH ≤ 15; sands 10–40; gravels 20–80 · by USCS group
Psamplemeasured force at 0.1 inField or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Pstandardstandard force at same penetrationConstantPhysical constant or standard value.project-specific
California Bearing Ratio (CBR) Test
California Bearing Ratio (CBR) Test
5.2.3.7 Resilient Modulus (AASHTO T307)

Method: Cyclic triaxial test with conditioning sequence (500 cycles at 4 psi deviator) followed by 15 stress states per AASHTO T 307 protocol.

M_r from regression (NCHRP 1-28A model):

M_r = k₁ × P_a × (θ/P_a)^k₂ × (τ_oct/P_a + 1)^k₃ (psi)

where:

  • P_a = atmospheric pressure = 2,117 psf = 14.7 psi
  • θ = bulk stress = σ₁ + σ₂ + σ₃ (psi)
  • τ_oct = octahedral shear stress (psi)
  • k₁, k₂, k₃ = regression constants from test

Minimum frequency: 1 test per subgrade soil type where the pavement or subgrade design uses M_r; confirm whether the owner requires it.

Repeated-load testing for track subgrade

Repeated-load triaxial (or simple shear) tests give two results that matter for track:

  • The resilient modulus, Er = cyclic deviator stress ÷ recoverable axial strain.
  • The rate at which plastic strain accumulates.

Tiny plastic strains per cycle add up to large settlement over millions of cycles, so report both.

What to look for.

  • In drained or unsaturated tests, the plastic increment shrinks with each cycle.
  • In saturated specimens, or at stresses near failure, the increment can grow. That is the runaway case.
  • Running a series of stress levels identifies the threshold stress used in Chapter 2.3, Section 2.3.4.2.
  • Er typically rises over the first cycles. Granular materials need several thousand cycles to stabilize, and their modulus is strongly dependent on confining pressure (Er = K1 θK2, where θ is bulk stress).

Test conditions. Test at the field moisture and density, including a wet-of-optimum case (Chapter 7.3). Fine-grained modulus falls steeply on the wet side.

After Selig & Waters (1994), chs. 3, 7 and 10. Full reference under Supplemental References.

Inputs for the equations in this section (4)
SymbolWhat it isComes fromHow to get itTypical range
Mrresilient modulus = k₁ × P_a × (θ/ P_a )^k₂ × ( τ_oct / P_a + 1)^k₃ (psi)Lab test (or correlation)Repeated-load triaxial (AASHTO T 307), or Mr ≈ 2,555·CBR0.64 (MEPDG).fine-grained 3,000–14,000 psi · by USCS group
Paatmospheric pressure = 2,117 psf = 14.7 psiConstantPhysical constant or standard value.project-specific
θbulk stress = σ₁ + σ₂ + σ₃ (psi)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
τoctoctahedral shear stress (psi)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Triaxial Shear Test
Triaxial Shear Test
Triaxial Shear Test Explained
Triaxial Shear Test Explained
5.2.3.8 One-Dimensional Consolidation (ASTM D2435)

Method A: Incremental load; load doubling each 24-hour interval; loads: 125–250–500–1,000–2,000–4,000–8,000 psf (standard); extend to 16,000 psf for deep or heavily preloaded sites.

Method B: Constant rate of strain (CRS); continuous loading at a controlled strain rate.

Key outputs (English units):

ParameterSymbolUnitsEquation
Compression indexC_cdimensionlessSlope of e-log σ'_v curve (NC range)
Recompression indexC_rdimensionlessSlope of e-log σ'_v curve (OC range); ≈ C_c/5 to C_c/10
Preconsolidation pressureσ'_ptsfCasagrande graphical construction
OCR—dimensionlessσ'_p / σ'_v0
Coefficient of consolidationc_vft²/dayc_v = T_v × H_dr² / t (see Chapter 6.2)
Secondary compression indexC_αdimensionlessΔe / Δ log t (secondary range)

Minimum frequency: 1 per fine-grained stratum per project; minimum 3 tests in any stratum requiring settlement analysis.

5.2.3.9 Unconsolidated-Undrained (UU) Triaxial (ASTM D2850)

Method: Undrained shear test on undisturbed sample; three specimens at different confining pressures (typically 500, 1,000, 2,000 psf); no drainage allowed during shear.

Unconsolidated–Undrained (UU) Triaxial Test
Unconsolidated–Undrained (UU) Triaxial Test

Output: s_u (psf or tsf) from Mohr circle at failure; φ_u ≈ 0° for saturated clay.

Note: For saturated clay, UU test gives s_u directly regardless of confining pressure — the Mohr circle diameter is constant. UU is appropriate for short-term (undrained) stability analysis only.

Minimum frequency: 1 per soft or medium clay stratum per boring at critical cross-sections (slope stability, embankment loading over soft clay).

Strength parameters: match the test to the drainage condition

  • CD tests give c′ ≈ 0 for both loose and dense soils. A small c′ appears only from a curved envelope or heavy overconsolidation. Use effective-stress parameters for drained problems.
  • CU tests. Dense sand develops negative excess pore pressure, so its undrained strength exceeds the drained strength (up to the limit of cavitation). Loose sand develops positive pore pressure, so its undrained strength is lower. φ′ is the same as from CD tests.
  • UU tests give φ = 0 and c = su, which depends only on the initial state. This is the convenient basis for short-term undrained loading.
  • Unconfined compression works only on fine soils that stand unsupported. Disturbance and unloading make it underestimate su.
  • Partially saturated subgrade. Pore pressure is rarely known, so analyze in total stress with both c and φ. Soil at low saturation behaves essentially drained in any test.
Drained vs Undrained Analysis
Drained vs Undrained Analysis
Triaxial Compression Test of Soil
Triaxial Compression Test of Soil
Unconfined Compression Test
Unconfined Compression Test
Figure 5.2-14. Bank, loose and compacted states of soil during earthwork.
Figure 5.2-14. Bank, loose and compacted states of soil during earthwork.

After Selig & Waters (1994), ch. 3. Full reference under Supplemental References.

5.2.3.10 Consolidated-Undrained (CU) Triaxial with Pore Pressure (ASTM D4767)

Method: Specimens consolidated to two or three effective confining pressures (σ'₃); sheared undrained with pore pressure measurement; effective stress Mohr circles give c' and φ'.

Output: c' (psf), φ' (degrees) — effective strength parameters for long-term (drained) analysis.

Minimum frequency: Required for all critical slope stability analyses (Class I railroad clay shale, Class I railroad clay located in the prairies, Class I railroad sensitive marine clay); 1 set (3 specimens) per stratum per project minimum.

5.2.3.11 Direct Shear (ASTM D3080)

Method: Specimen sheared at constant normal stress; three tests at different normal stresses.

Peak and residual strength:

τ_peak = c' + σ_n × tan φ'_peak (psf)

τ_residual = σ_n × tan φ'_r (psf, c' = 0 for residual)

Output: c' (psf), φ' (degrees), φ'_r (degrees).

Use cases: Residual strength for Class I railroad clay shale and Class I railroad weathered shale slope stability; rock joint shear strength for cut slope design.

Minimum frequency: 1 per stratum requiring residual strength parameters; rock joints: minimum 3 direct shear tests per joint set per project.

Inputs for the equations in this section (2)
SymbolWhat it isComes fromHow to get itTypical range
φ'effective friction angleLab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
c'effective cohesionLab testEffective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more.0–300 psf · by USCS group
Direct Shear Test
Direct Shear Test
5.2.3.12 Unconfined Compression (ASTM D2166)

Method: Axial loading to failure at unconfined conditions (σ₃ = 0). Quick and inexpensive.

Output: q_u (psf or tsf); s_u = q_u / 2.

Limitation: UU triaxial provides more reliable s_u; unconfined compression can underestimate s_u in fissured or brittle clays. Use for screening; not for final design in critical applications.

Minimum frequency: Appropriate for routine s_u checks on Shelby tube samples; supplement with UU triaxial for design-level analysis.

5.2.3.13 Hydraulic Conductivity (Permeability)

Constant head (ASTM D2434): For coarse-grained soils (k above about 3 ft/day, 10⁻³ cm/s).

k = (Q × L) / (A × h × t) (ft/day)

where Q = flow volume (ft³); L = specimen length (ft); A = cross-sectional area (ft²); h = head differential (ft); t = test duration (day).

Flexible wall permeameter (ASTM D5084): For fine-grained soils (k below about 3 ft/day, 10⁻³ cm/s).

k = (a × L × ln(h₁/h₂)) / (A × t) (ft/day)

where a = standpipe area (ft²); L = specimen length (ft); h₁, h₂ = head at start and end; t = elapsed time (day).

Minimum frequency: 1 per stratum for drainage design; 3 per stratum for seepage analysis through embankments or dams.

Inputs for the equations in this section (5)
SymbolWhat it isComes fromHow to get itTypical range
k(Q × L) / (A × h × t) (ft/day)Field or lab testField: pumping test, slug test (ASTM D4044, withdrawn 2024) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only.clean sand 1–100, clay < 0.001 ft/day · by USCS group
Lspecimen length (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Across-sectional area (ft²)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
hhead differential (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
ttest duration (day).TimeElapsed test time (recorded) or the analysis time chosen for design.project-specific
Constant Head Permeability Test
Constant Head Permeability Test
5.2.3.14 Point Load Index (ASTM D5731)

Method: Rock core or irregular lump loaded to failure between conical platens.

Point load strength index:

I_s = P / D_e² (psi or psf)

where P = failure load (lb); D_e = equivalent core diameter (in.).

Size-corrected index:

I_s(50) = F × I_s where F = (D_e/1.97 in.)^0.45

Estimated UCS of rock:

q_u(rock) ≈ 24 × I_s(50) (psi) [Broch & Franklin 1972; I_s in psi]

Minimum frequency: at least 10 valid tests per rock unit (ASTM D5731, withdrawn 2025); not a substitute for UCS testing for critical rock foundation designs.

Rock Triaxial Testing
Rock Triaxial Testing
Inputs for the equations in this section (3)
SymbolWhat it isComes fromHow to get itTypical range
IsP / D_e² (psi or psf)Lab testUniaxial compression of rock core (ASTM D7012); point load index (D5731) for screening.shale 1,000–15,000; sandstone 5,000–25,000; granite 15,000–40,000 psi
Deequivalent core diameter (in.).Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Is(50)F × I_s where F = ( D_e /1.97 in.)^0.45Lab testUniaxial compression of rock core (ASTM D7012); point load index (D5731) for screening.shale 1,000–15,000; sandstone 5,000–25,000; granite 15,000–40,000 psi
Supplemental reference

USACE Q / R / S nomenclature and common triaxial errors

USACE manuals (EM 1110-2-1902 slope stability, EM 1110-2-2504 sheet piles, and others cited in this manual) use letter names for the basic triaxial tests: Q = unconsolidated-undrained (UU); R = consolidated-undrained (CU); S = consolidated-drained (CD), which is also the long-term drained case. The Q test applies only to soils that are not free-draining, and R-test specimens should generally be fully saturated before shear. Errors EM 1110-2-1906 lists for R tests: back-pressure increments too large or applied too fast; chamber and back pressure not held precisely (which can overconsolidate the specimen); shearing before consolidation is complete; too fast a strain rate; temperature drift; and water absorbed from the porous inserts after the test, which biases the final water content. For S tests the main errors are strain rate and volume-change measurement. In pervious soils, water redistributes even in a quick Q test, so measure the water content of the middle third separately from the ends.

Details of a typical triaxial compression chamber for 1.4-in.-diameter specimens (EM 1110-2-1906).
Supplemental Figure 10-S2. Details of a typical triaxial compression chamber for 1.4-in.-diameter specimens (EM 1110-2-1906). Source: U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906, p. X-4.

Picking t50 and t90 from each load increment

Section 5.2.3.8 gives cv = TvHdr2/t but not how t is found. The two standard curve-fitting methods (Das lab manual) are:

  • Square-root-of-time (Taylor, 1942): plot dial reading against √t, extend the initial straight line, draw a second line from the same origin with abscissas 1.15 times larger, and read t90 where it cuts the curve. Then cv = 0.848 Hdr2/t90.
  • Log-of-time (Casagrande and Fadum, 1940): d100 is the intersection of the primary and secondary straight lines. For d0, pick t1 and t2 = 4t1 in the early curved part and step up by their difference. t50 is at d50 = (d0 + d100)/2. Then cv = 0.197 Hdr2/t50, and Cα comes from the slope after d100.

With double drainage, Hdr is half the average specimen height during the increment. Report which method was used. The two methods commonly give different cv values for the same increment, and the report should say which one the settlement-time analysis in Chapter 6.2 used.

Source: U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906 · Das, B. M. (2002). Soil Mechanics Laboratory Manual, 6th ed. Oxford University Press

Schematic of fixed-ring and floating-ring consolidometers (EM 1110-2-1906). Apparatus compression in either type must be calibrated out for stiff soils.
Supplemental Figure 10-S1. Schematic of fixed-ring and floating-ring consolidometers (EM 1110-2-1906). Apparatus compression in either type must be calibrated out for stiff soils. Source: U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906, p. VIII-2.
Supplemental reference

Tests for shale and mudstone: preparation effects and slake durability

Railroad cuts in Appalachian and prairie shales (Chapter 6.3) need durability as well as strength data, and Atterberg limits of clay shale depend on how the sample was processed. EM 1110-2-1906 therefore standardizes three preparations: blenderized (the primary reference — dried below 122°F at < 30% RH, soaked at least 48 hr, then blended as a slurry above 300% water content or twice the LL); undried (shaved directly into distilled water); and air-dried (one drying–soaking cycle). The spread among the three indicates the strength of interparticle bonds. Report which method produced the limits used for design.

Atterberg Limits
Atterberg Limits

Slake durability (Franklin and Chandra, 1972; ASTM D4644, withdrawn 2025): oven-dried rock lumps are rotated for 10 minutes in a sieve-mesh drum half immersed in 68°F water. Id is the percentage of the initial dry mass retained. Nagaraj reports reproducibility within 5% at 95% confidence, and the test discriminates well between mudstones that otherwise look alike.

Id (%)0–2525–5050–7575–9090–9595–100
DurabilityVery lowLowMediumHighVery highExtremely high

After Franklin and Chandra (1972). As printed in Nagaraj’s Table 9.7, the 75–90 and 90–95 labels are transposed; the order shown here is the original.

For clay shales, Nagaraj also reproduces the Morgenstern and Eigenbrod (1974) classification, which combines the amount of slaking (by the liquid limit of the slaked material: < 20 very low to > 140 very high) with the rate (change in liquidity index in the first cycle: < 0.75 slow, 0.75–1.25 fast, > 1.25 very fast). Add slake durability to the rock column of Table 5.2-1 for every cut in shale, mudstone or claystone and for any rock proposed as riprap or fill.

Source: U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906 · Nagaraj, T. S. (1993). Principles of Testing Soils, Rocks and Concrete. Elsevier (Developments in Geotechnical Engineering)

Physico-Mechanical Properties of Rocks
Physico-Mechanical Properties of Rocks

Ballast and subballast abrasion tests (Deval, Los Angeles, Micro-Deval)

Table 5.2-7. Abrasion tests for railway aggregates as described by Profillidis
TestEquipment and procedureResult
Deval (1896)11-lb sample in cylinders 8 in. dia. × 13 in., inclined 30°; 10,000 revolutions at 2,000 rev/h (about 5 h); dry or wetDeval coefficient from % attrition. Typical minimums: > 12 (limestone), > 14 (hard rock), some railways > 16
Los Angeles (1926)Drum 28 in. dia. × 20 in.; 11-lb sample with 12 steel balls of 15 oz each; 500 revolutions at 30–33 rpm (about 15 min). EN version: 22-lb sample, 1,000 revolutions% passing No. 12 (French) or No. 8 (British) sieve. Many specifications: LA < 25. EN reference test
Micro-Deval1.1 lb of ⅜–½ in. gravel with 11 lb of small steel balls (about ⅜ in.) and 2.6 qt of water in an 8-in. cylinder; 12,000 revolutions at 100 rpm. EN version: 22 lb, 14,000 revolutionsMDE = % finer than No. 12. Used mainly for subballast; subballast MDE < 15–20
Figure 5.2-11. Deval attrition machine. Profillidis Fig. 12.4.
Figure 5.2-11. Deval attrition machine. Profillidis Fig. 12.4.

North American ballast specifications (AREMA Chapter 1) use the ASTM Los Angeles test for large coarse aggregate (ASTM C535). Results from the European methods are not interchangeable with ASTM results without correlation.

Cyclic behavior. Ballast takes a large permanent set on first loading as stones rearrange, then accumulates strain slowly: εN = ε1(1 + c·log N), with c ≈ 0.2 (European ORE and British Rail research) or 0.25–0.40 (American research). On that basis it takes 100,000–300,000 cycles to double the first-cycle plastic strain. Ballast modulus roughly doubles over the first 1,000 cycles and then stays nearly constant; gravel subballast modulus does not change with cycles. Repeated-load triaxial programs should run long enough to get past this initial bedding-in.

Figure 5.2-12. Elastic deformation of ballast vs. number of loading cycles N. Profillidis Fig. 12.3.
Figure 5.2-12. Elastic deformation of ballast vs. number of loading cycles N. Profillidis Fig. 12.3.

After Profillidis (2014), §12.3–12.4, Eq. 12.1, Figs. 12.3–12.4. Full reference under Supplemental References.

Standard index tests for subgrade samples

Table 5.2-8. Standard laboratory battery for subgrade samples (course summary)
TestStandardWhat it gives
Atterberg limitsASTM D4318Liquid limit, plastic limit, plasticity index; classifies fines
Particle-size distributionASTM D6913 (sieve), D7928 (hydrometer)Sieve gradation, % finer than No. 200, hydrometer split of silt and clay
Moisture contentASTM D2216 (oven); D4643 (microwave, for quick checks)Water content by drying
Unconfined compressive strengthASTM D2166Direct strength of cohesive samples
Proctor compactionASTM D698 / D1557Target density and optimum moisture for fill and subgrade
Compressive Strength Test of Cement
Compressive Strength Test of Cement
Core Test Compressive Strength Test
Core Test Compressive Strength Test
Triaxial Compressive Strength test
Triaxial Compressive Strength test
Uniaxial Compressive Strength
Uniaxial Compressive Strength
Liquid Limit and Plastic Limit Tests
Liquid Limit and Plastic Limit Tests
Standard Proctor Test
Standard Proctor Test
Proctor Compaction Test
Proctor Compaction Test
Soil Compaction and Maximum Dry Density
Soil Compaction and Maximum Dry Density
Figure 5.2-13. Proctor compaction device.
Figure 5.2-13. Proctor compaction device.

Compaction can roughly double a soil’s strength. The fines content of granular fill controls its drainage, frost susceptibility and strength after rain, so specify and test fines on ballast and sub-ballast deliveries rather than accepting material that only looks good dry.

After Geotechnology for Railroaders Program, Module 2; §09–10. Full reference under Supplemental References.

Case study: 5.2.16.1 Curing time changes compaction and CBR results (Look 2023), in Section 5.2.16 Case Studies.

5.2.4 Sample Handling and Chain of Custody
5.2.4.1 Shelby Tube Handling

Shelby tubes (ASTM D1587, withdrawn 2024 thin-wall samples) must be:

Storage of Samples
Storage of Samples
  • Sealed at both ends with wax within 2 hours of extraction
  • Stored vertically (upright) in a padded core box or individual foam holders
  • Transported at ambient temperature; never frozen (unless specifically permitted for permafrost)
  • Extruded at laboratory in a horizontal extruder within 30 days of collection
  • Never impact-loaded, dropped, or inverted during transport

Sample Quality Designation (Lunne et al. 1997, for OCR 1–2) — also referenced in Chapter 4.1:

Δe/e₀Quality
< 0.04Very good to excellent
0.04–0.07Good to fair
0.07–0.14Poor
> 0.14Very poor

Report SQD for all consolidation and triaxial test specimens. Note samples with SQD = Poor or Very Poor in the report, with a caveat on the reliability of the strength and compressibility parameters derived from them.

5.2.4.2 Chain of Custody

A chain of custody (COC) form must accompany every sample shipment from field to laboratory. Required fields:

  • Project name and number; client railroad
  • Boring ID, sample ID, sample type, and depth interval
  • Date and time of collection; collector's name
  • Date and time of departure from field; shipper's name
  • Date and time of receipt at laboratory; receiver's name and signature
  • Condition of samples at receipt (sealed, intact, disturbed)
  • Tests assigned (referenced to lab test request form)
  • Custody transfer: any intermediate handler must sign and date

Owner railroads may require COC forms to be scanned and submitted with the laboratory report as a QC attachment.

5.2.5 Laboratory QA/QC
5.2.5.1 Duplicate Testing

A minimum of 10% of all tests (by test type) must be run in duplicate as a QC check. Duplicate tests are run on split halves of the same sample by the same method. Acceptable precision limits:

Table 5.2-2. Laboratory Test Precision Requirements
TestAcceptable Duplicate DifferenceAction if Exceeded
Water content (D2216)≤ 1.0%Repeat test on third portion
Atterberg limits (D4318)LL ≤ 2%, PL ≤ 2%Repeat; average of three if still outside
Modified Proctor (D1557)γ_d,max ≤ 1.0 pcf; w_opt ≤ 1.0%Rerun entire compaction curve
Consolidation C_c (D2435)≤ 0.05Flag and report; use higher value for design
UU triaxial s_u (D2850)≤ 10% of meanInvestigate specimen preparation
CBR (D1883)≤ 5 percentage pointsAverage of three specimens
5.2.5.2 Reference Standards

The laboratory must maintain certified reference standards for:

  • Atterberg limits: reference LL material (typical LL ≈ 30%; verified against liquid limit standard)
  • Proctor: reference soil with known γ_d,max ± 0.5 pcf and w_opt ± 0.5% (checked semiannually)
  • Sieve analysis: NIST-traceable calibrated sieves (checked annually)
  • Consolidation: calibrated load frames and displacement transducers (calibrated annually)
  • Triaxial: calibrated load cells (ASTM E4), pressure transducers, and displacement gauges
5.2.5.3 Laboratory Report Requirements

Each laboratory report must contain:

  • Project name, boring ID, sample ID, test date
  • Test method reference (ASTM standard edition)
  • Technician and supervisor names
  • All raw data (loads, deformations, masses, dimensions)
  • Calculated results with units
  • Any deviations from standard method noted
  • Supervisor review signature
Supplemental reference

Equipment checks that most often go wrong (USACE EM 1110-2-1909)

  • Temperature: keep rooms used for consolidation, permeability, triaxial (especially with pore pressure) and direct shear within ± 5°F; otherwise results become erratic. EM 1110-2-1906 adds that a temperature rise during undrained shear lowers effective stress — a problem that grows with test duration.
  • Mechanical compaction rammers: calibrate before first use, after every 500 mold fillings, after any repair, whenever results are questionable, and after any 6-month period without calibration — separately for standard and modified effort and for each foot type. Check drop height at operating speed, not in slow operation.
  • Consolidometer deformation: for stiff clays and dense sands, a significant part of the measured compression can be in the apparatus and porous stones. Load a dummy setup (wet stones with filter paper, or a metal disk) through the test sequence until readings repeat within about 0.0005 in. between cycles (usually three cycles) and subtract the apparatus correction at each load. In the USACE example, apparatus deformation at 4 tsf was about 0.008 in. — not negligible for an OC clay specimen. Recalibrate each test until the correction proves stable, then semiannually or annually.
  • Liquid limit device: check new devices on arrival, since many do not meet specification. Check base hardness yearly by dropping a 5/16-in. steel ball from 10 in.: rebound must be 7.3–9.0 in.
  • Records: keep the date, who calibrated, and the devices and methods used for every calibration. Lab audits for Section 5.2.8 accreditation will ask for them.

Specimen selection matters more than test count. EM 1110-2-1906 stresses that strength, compressibility and permeability can vary severalfold within a few inches. Specimen selection therefore needs personal inspection of the samples by the laboratory and the design engineer together, not selection from boring logs alone. Its guiding principle: “one good test is not only far better than many poor tests, but is also less expensive.” Undisturbed samples should not be stored for long periods, because physical and chemical changes eventually invalidate them.

Source: U.S. Army Corps of Engineers (1970, with changes through 1986). Calibration of Laboratory Soils Testing Equipment. EM 1110-2-1909 · U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906

Case study: 5.2.16.2 Laboratory variation in Cooroy clay compaction curves (Look 2023), in Section 5.2.16 Case Studies.

5.2.6 Turnaround Time by Client
Table 5.2-3. Laboratory Test Turnaround Time Requirements by Railroad Client
TestClass IClass IClass IClass IClass IPassengerClass IShort line
Water content, Atterberg, grain size5 business days5 business days5 business days5 business days5 business days5 business days5 business days5 business days
Modified Proctor7 business days7 business days7 business days7 business days7 business days7 business days7 business days7 business days
CBR (soaked)10 business days10 business days10 business days10 business days10 business days10 business days10 business days10 business days
UU Triaxial10 business days10 business days10 business days10 business days10 business days10 business days10 business days10 business days
CU Triaxial15 business days15 business days15 business days15 business days15 business days15 business days15 business days15 business days
Consolidation (D2435)14 business days14 business days14 business days14 business days14 business days14 business days14 business days14 business days
Resilient modulus (T307)Not requiredNot requiredNot required15 business days15 business days15 business days15 business daysNot required

Rush processing (1.5–2× standard fee): available from most accredited labs at 50–70% of standard turnaround times. Confirm availability at project initiation for emergency and fast-track projects.

5.2.7 Sample Retention Requirements

Sample Retention Policy vary by owner railroad. Confirm them against the owner railroad's current standards when the work is scoped, and record the edition used.

Owner railroads reserve the right to request sample re-testing or third-party verification testing within the retention period.

5.2.8 Laboratory Accreditation Requirements

Laboratory Accreditation Requirements vary by owner railroad. Confirm them against the owner railroad's current standards when the work is scoped, and record the edition used.

Key accreditation bodies:

  • AAP (AASHTO Accreditation Program): Covers all geotechnical and pavement lab tests; scope is per-method
  • A2LA: ISO/IEC 17025 accreditation; broader scope; confirm acceptance with the owner railroad
  • CCRL (Cement and Concrete Reference Laboratory): ASTM-sponsored inspection and proficiency program, located at NIST, for cement, concrete and aggregate testing (including LA abrasion and soundness); it supports accreditation rather than accrediting laboratories itself
  • SCC (Standards Council of Canada): Canadian national accreditation body
5.2.9 Worked Calculation Examples
The three examples reduce the three laboratory tests that most often control railroad designs: consolidation, compaction with CBR, and CU triaxial. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution.
Example 5.2-1: Consolidation Test Analysis for a Bridge Approach

An oedometer test on a tube sample from 18 to 20 ft under a bridge approach embankment on a Class I railroad located in Georgia. Three numbers come out of the e-log σ′ curve: the preconsolidation stress, the compression index above it and the recompression index below it. Together with the present effective stress they say which settlement equation of Chapter 6.2 applies.

0.111011.21.41.61.8σ′ (tsf, log scale)Void ratio eσ′p = 1.50 tsfCc = ?Cr = ?OCR = ?Givene at 0.125–16 tsf (8 stages)σ′p = 1.50 tsf (Casagrande)γsat = 115 pcf; GWT at surfaceSample depth z = 19 ftRequiredCc and Cr OCRBlack = given; red = required
Given and required for Example 5.2-1.

Given

VariableValueDescription
Dataσ′ = 0.125, 0.25, 0.5, 1, 2, 4, 8, 16 tsf; e = 1.820, 1.795, 1.762, 1.698, 1.590, 1.430, 1.235, 1.015End of each load stage
σ′p1.50 tsfCasagrande construction (maximum curvature near 1.0 to 1.5 tsf)
γsat115 pcfWater table at the surface
z19 ftSample depth

Required

  • Cc and Cr
  • OCR

Equations

  1. Eq. 1: C = Δe / Δlog σ′ — slope of the e-log σ′ curve; Cc in the virgin range, Cr below σ′p
  2. Eq. 2: σ′v0 = (γsat − γw) z — present effective stress
  3. Eq. 3: OCR = σ′p / σ′v0

Steps

Step 1 · Cc, 2 to 8 tsf (Eq. 1)
(1.590 − 1.235) / log(8/2) = 0.355 / 0.602
Cc = 0.590
↓
Step 2 · Cr, 0.125 to 1 tsf (Eq. 1)
(1.820 − 1.698) / log(1/0.125) = 0.122 / 0.903
Cr = 0.135
Spot check: Cr/Cc = 0.23, within the usual 0.1 to 0.25.
↓
Step 3 · σ′v0 (Eq. 2)
(115 − 62.4) × 19
999 psf = 0.50 tsf
↓
Step 4 · OCR (Eq. 3)
1.50 / 0.50
OCR = 3.0
↓
Solution
Cc = 0.590; Cr = 0.135; σ′p = 1.50 tsf; OCR = 3.0.

Solution

Cc = 0.590, Cr = 0.135, σ′p = 1.50 tsf and OCR = 3.0: a moderately overconsolidated clay.

Use the overconsolidated settlement equations of Chapter 6.2: recompression only while the final stress stays below 1.50 tsf, and recompression plus virgin compression if the embankment pushes it past. Report all four values in the engineering properties table of the geotechnical report. Cc is taken from the straight part of the curve well above σ′p, not from the bend.

Example 5.2-2: Modified Proctor and Soaked CBR

Subgrade for an intermodal yard expansion on a Class I railroad located in Kansas City. The Proctor test sets the compaction reference; the CBR is run on a specimen compacted to the specified fraction of it and soaked, which is the condition the subgrade will be in after a wet season.

1012141618110115120Water content w (%)γd (pcf)γd,max, wopt = ?Design CBR = ? Target 95%?Givenw = 10.5, 12, 14, 16, 18%γd = 111.8, 115.4, 118.2, 117.1, 113.5RC 95%CBR loads 730 lb @0.1; 960 lb @0.2 in.Standard 3,000 / 4,500 lbRequire CBR ≥ 20%Requiredγd,max, wopt and target densityDesign CBRBlack = given; red = required
Given and required for Example 5.2-2.

Given

VariableValueDescription
Proctor pointsw = 10.5, 12, 14, 16, 18%; γd = 111.8, 115.4, 118.2, 117.1, 113.5 pcfModified Proctor
RC95% (assumed)Specimen compaction
Loads730 lb at 0.1 in.; 960 lb at 0.2 in.Soaked CBR
Standard loads3,000 lb at 0.1 in.; 4,500 lb at 0.2 in.ASTM D1883
RequirementCBR ≥ 20% (assumed)Subgrade or blanket

Required

  • γd,max, wopt and target density
  • Design CBR

Equations

  1. Eq. 1: γd,target = RC × γd,max
  2. Eq. 2: CBR = P / Pstd × 100% — at 0.1 and 0.2 in.; the higher governs if the test is valid

Steps

Step 1 · Peak of the curve
γd,max = 118.2 pcf at wopt = 14.0%
↓
Step 2 · Target (Eq. 1)
0.95 × 118.2
112.3 pcf
↓
Step 3 · CBR (Eq. 2)
730/3,000; 960/4,500
24.3% and 21.3%; 0.1 in. governs
↓
Solution
Design CBR = 24%.

Solution

γd,max = 118.2 pcf at 14.0%; design CBR = 24.3%, just above the assumed 20% requirement.

A soaked CBR of 24% is high for a lean clay, which commonly tests between 3 and 15%. Before the value is used, check the specimen’s classification, compaction and soak record, and run at least three more tests across the yard footprint. If the result is confirmed, the subgrade is marginally adequate; if not, plan for a blanket layer or treatment (Chapter 7.3).

Example 5.2-3: Effective Strength From a CU Triaxial Test

A cut slope in residual silty clay on a Class I railroad located in Appalachia. Three CU specimens with pore pressure measurement give the effective strength parameters for long-term (drained) slope stability. The p′-q′ plot turns three Mohr circles into a straight line, whose slope and intercept give φ′ and c′.

0200040006000800001000200030004000Normal stress σ′ (psf)Shear stress (psf)Envelope: φ′, c′ = ?Givenσ3 = 1,000; 2,000; 3,000 psfΔuf = 400; 710; 1,050 psfq = 820; 1,540; 2,290 psfRequiredEffective φ′ and c′Black = given; red = required
Given and required for Example 5.2-3.

Given

VariableValueDescription
σ31,000; 2,000; 3,000 psfCell pressures, specimens A to C
Δuf400; 710; 1,050 psfPore pressure at failure
q820; 1,540; 2,290 psf(σ1 − σ3)/2 at failure

Required

  • Effective φ′ and c′

Equations

  1. Eq. 1: σ′3 = σ3 − Δu; σ′1 = σ′3 + 2q
  2. Eq. 2: p′ = (σ′1 + σ′3)/2
  3. Eq. 3: q = a + p′ tanα; sinφ′ = tanα; c′ = a / cosφ′ — modified failure envelope

Steps

Step 1 · Effective stresses (Eq. 1)
A: 600 and 2,240; B: 1,290 and 4,370; C: 1,950 and 6,530 psf
σ′3 and σ′1
↓
Step 2 · Centers p′ (Eq. 2)
1,420; 2,830; 4,240 psf
↓
Step 3 · Slope (Eq. 3)
(2,290 − 820)/(4,240 − 1,420) = 1,470 / 2,820
tanα = 0.521; φ′ = 31°
↓
Step 4 · Intercept and c′ (Eq. 3)
a = 1,550 − 0.521 × 2,830 = 75 psf; 75 / cos 31°
c′ ≈ 90 psf
Spot check: Specimen B: 75 + 0.521 × 2,830 = 1,550 psf, against a measured q of 1,540 psf.
↓
Solution
φ′ = 31°; c′ ≈ 90 psf.

Solution

φ′ ≈ 31° and c′ ≈ 90 psf.

These are for long-term (drained) stability. Small cohesion intercepts from three points are uncertain; for a cut slope with a factor of safety near 1.3, test at least two more specimens and consider checking the slope with c′ = 0, because weathering of a residual soil in the cut face destroys cohesion first.

5.2.10 Representative Lab Data Table
Table 5.2-6. Laboratory Test Summary — Class I railroad subdivision Bridge Approach located in Georgia (8 Borings)
BoringSampleDepth (ft)USCSLLPLPIw (%)γ_d (pcf)s_u (tsf)φ' (°)c' (psf)C_cC_rσ'_p (tsf)k (ft/day)
B-1SS-38–10CL42202224.1————————
B-1ST-112–14CH65283738.578.20.24——0.520.111.20—
B-2SS-410–12CL35221318.2————————
B-3ST-118–20CH71294242.176.50.19——0.590.141.502.1×10⁻⁵
B-3SS-625–27SC——49.8——32°0————
B-4ST-215–17CL48222629.480.10.31——0.440.091.35—
B-5SS-38–10CL44212322.8————————
B-6ST-112–14CH68274140.277.40.2231°2000.570.121.45—
5.2.11 Reference Photographs
Why Soil Consolidation Happens
Why Soil Consolidation Happens
Proctor Compaction Test
Proctor Compaction Test
Cone Penetration Test
Cone Penetration Test
Triaxial Shear Test
Triaxial Shear Test
Flexible Pavement Layers — Subgrade to Asphalt
Flexible Pavement Layers — Subgrade to Asphalt
5.2.12 Practical Recommendations
  1. Write the laboratory test program before the field crew mobilizes. A well-designed test program begins with the analysis matrix (Table 5.2-1). Know which tests are needed before drilling begins so that samples are collected, preserved, and shipped appropriately. Changing the test program after samples have dried or disturbed is expensive and unreliable.
  2. Confirm laboratory accreditation per-method, not per-lab. An AAP-accredited lab may be accredited for D2216 and D4318 but not for D4767 (CU triaxial). Always verify the accreditation scope certificate for every test method in the program. Owners that require accreditation may reject data produced outside its scope.
  3. Ship Shelby tubes within 72 hours of collection. Sample quality degrades with time, handling, and temperature cycling. The SQD classification (Section 5.2.4.1) will reveal disturbance — but by then the sample is consumed. Minimize handling, seal immediately, and ship promptly.
  4. Always run water content on all samples, even those not assigned to formal tests. Water content needs little labor and costs almost nothing. It documents the in-situ condition of every sample and supports stratigraphic correlation, parameter estimation, and QC. A boring with 20 samples and only 5 water contents is professionally incomplete.
  5. Request electronic data delivery in addition to PDF reports. All major geotechnical laboratories can deliver test data in CSV or Excel format. Request this at the time of laboratory subcontract award. Electronic data is essential for efficient entry into calculation spreadsheets and prevents transcription errors from PDF reports.
  6. Verify specific gravity before computing void ratio in consolidation analysis. The void ratio calculation (e = G_s × γ_w / γ_d − 1) is directly affected by G_s. Assuming G_s = 2.70 for a kaolin-rich clay (G_s may be 2.60–2.65) overestimates e₀, and because Δe scales with 1 + e₀ it also overstates C_c. Always measure G_s on the same material used for consolidation testing.
  7. For projects in Canada, confirm metric vs. English unit reporting requirements with the laboratory. Canadian laboratories report in SI units by default. Specify English unit output in the lab subcontract, or include a unit conversion table in the laboratory report appendix, and verify conversions before using values in design.
Geotechnical laboratory testing for earth dam clay cores
Geotechnical laboratory testing for earth dam clay cores
5.2.13 Laboratory Testing Checklist

Checklist · Part V · Subsurface Exploration

Laboratory Testing Checklist

Pre-Field0 of 7
Field0 of 6
Laboratory Phase0 of 6
Report Integration0 of 5
Ticks are saved in this browser.
Plain text version

Pre-Field

  • [ ] Analysis matrix completed (Table 5.2-1 adapted to project type); tests selected match analytical needs
  • [ ] Laboratory subcontract awarded; accreditation scope verified per-method for all required tests
  • [ ] COC forms prepared and printed; field team briefed on COC procedure
  • [ ] Shelby tube size and quantity confirmed (typically 3-in. OD for ASTM D1587, withdrawn 2024)
  • [ ] Shipping coolers, foam padding, and waterproof labels procured
  • [ ] Rush processing option confirmed with laboratory (if project schedule requires)
  • [ ] Sample retention requirements confirmed with client

Field

  • [ ] Water content taken on every sample (no exceptions)
  • [ ] Shelby tubes sealed within 2 hours of extraction; ends waxed
  • [ ] COC form completed for each sample; signed by collector
  • [ ] Samples shipped within 72 hours; COC transmitted to laboratory with shipment
  • [ ] Condition at laboratory receipt confirmed (email or call from lab supervisor)
  • [ ] Test assignments transmitted to laboratory with priority schedule

Laboratory Phase

  • [ ] 10% duplicate testing performed per QC program (Table 5.2-2)
  • [ ] SQD computed for all Shelby tube-based tests; poor quality samples flagged
  • [ ] All raw data retained by laboratory (not just final results)
  • [ ] Laboratory report includes technician and supervisor signatures
  • [ ] Electronic data (CSV or Excel) received and checked against PDF report
  • [ ] Accreditation certificate attached to laboratory report as QC document

Report Integration

  • [ ] Lab data master table complete (all samples; Table 5.2-6 format)
  • [ ] All design parameters sourced from lab data with traceability to sample ID and test date
  • [ ] SQD flags noted in engineering properties discussion (Section 6 of GDR/FGR)
  • [ ] Any test anomalies or out-of-specification results explained in report narrative
  • [ ] Sample retention calendar established; laboratory notified of client retention requirements
5.2.14 Cross-Reference Table
TopicSee Also
SPT N-value correction using γ_d and G_sChapter 4.1
In situ test correlation to lab parametersChapter 5.1
USCS classification using Atterberg limits and grain sizeChapter 2.2
Groundwater (effect on consolidation parameters)Chapter 2.8
Bearing capacity using c', φ' from triaxialChapter 6.1
Settlement using C_c, C_r, σ'_p from consolidationChapter 6.2
Slope stability using φ' and c' from CU triaxialChapter 6.3
Liquefaction using fines content and FC correctionChapter 6.5
CBR and M_r for pavement designChapter 7.3
Ground improvement parameter selectionChapter 7.2
Retaining wall backfill φ' from direct shearChapter 7.1
Subgrade s_u from UU triaxial for subgrade FSChapter 2.3
Reference Proctor for compaction acceptanceChapter 5.3
Lab data table format in final reportChapter 8.4
Lab test data table template (blank)Appendix B
5.2.15 Practice Questions
Each question is worked in the same five parts as the examples. Question 5.2-3 is a reasoning question.
Question 5.2-1: Compression Index, OCR and Which Settlement Equation

Problem Statement

A consolidation test was run on a tube sample from beneath a planned railroad embankment. The test gave the void ratios in the virgin range and the stresses shown. The engineer must compute the compression index and the overconsolidation ratio and decide which settlement equation applies to the embankment load.

1101.11.31.5σ′ (tsf, log scale)Void ratio e1.42 at 1.0 tsf1.18 at 4.0 tsfσ′v0 σ′p Cc = ?OCR = ? Which equation?Givene = 1.42 at 1.0 tsf (virgin)e = 1.18 at 4.0 tsf (virgin)σ′v0 = 0.80 tsfσ′p = 1.60 tsfRequired(a) Cc (b) OCR(c) Which Chapter 6.2 equationBlack = given; red = required
Given and required for Question 5.2-1.

Given

VariableValueDescription
Pointse = 1.42 at 1.0 tsf; e = 1.18 at 4.0 tsfVirgin range
σ′v00.80 tsf
σ′p1.60 tsfCasagrande

Required

  • (a) Cc
  • (b) OCR
  • (c) Which Chapter 6.2 equation applies

Equations

  1. Eq. 1: Cc = Δe / Δlog σ′
  2. Eq. 2: OCR = σ′p/σ′v0

Steps

Step 1 · (a) Cc
0.24 / 0.602
0.399
↓
Step 2 · (b) OCR
1.60/0.80
2.0
↓
Step 3 · (c) Equation
Depends on the final stress: recompression only if it stays below 1.60 tsf; recompression plus virgin compression if it exceeds it
↓
Solution
Cc = 0.40; OCR = 2.0; equation depends on the final stress.

Solution

(a) Cc = 0.40. (b) OCR = 2.0. (c) The overconsolidated equations; which one depends on whether the final stress passes 1.60 tsf.

The new load decides the case, so compute σ′vf = σ′v0 + Δσ before choosing.

Question 5.2-2: Field Density Acceptance

Problem Statement

A nuclear gauge test on a lift of fill for a new railroad yard gave the field density and moisture shown. The railroad’s specification requires 95% of Modified Proctor and moisture within 3% of optimum. The inspector must decide whether the lift passes on density and on moisture.

10141822110115120Water content w (%)γd (pcf)max 120.5 at 14.0%field 117.4 at 17.2%RC = ? Density and moisture pass?Givenγd,field = 117.4 pcfγd,max = 120.5 pcfw = 17.2%; wopt = 14.0%Spec: RC ≥ 95%; w ±3%Required(a) RC(b) Density pass or fail(c) Moisture pass or failBlack = given; red = required
Given and required for Question 5.2-2.

Given

VariableValueDescription
γd,field117.4 pcf
γd,max120.5 pcfModified Proctor
w, wopt17.2%; 14.0%
SpecRC ≥ 95%; w within ±3% of optimumRailroad requirement

Required

  • (a) RC
  • (b) Density pass or fail
  • (c) Moisture pass or fail

Equations

  1. Eq. 1: RC = γd,field/γd,max × 100%

Steps

Step 1 · (a) RC
117.4 / 120.5
97.4%
↓
Step 2 · (b) Density
97.4 ≥ 95
Pass
↓
Step 3 · (c) Moisture
Window 11.0 to 17.0%; field 17.2%
Fail, wet side
↓
Solution
RC 97.4% passes; moisture 17.2% fails.

Solution

(a) 97.4%. (b) Passes. (c) Fails: 0.2% above the wet limit.

Rework or dry the lift and retest before placing the next one. A wet-side lift that passes density can still rut and pump under construction traffic, which is why both criteria must be met.

Question 5.2-3: Choosing Between Two Consolidation Tests

Problem Statement

Two consolidation tests on the same clay stratum beneath a planned railroad bridge approach fill gave different compression indices, and the sample quality measurements differ as shown. The engineer must decide which compression index to use for the approach settlement and why.

Two tests on the same stratum disagree; sample quality decides which to trust.

0.1110σ′ (log scale)Void ratio eA: Cc = 0.45, Δe/e0 = 0.06B: Cc = 0.31, Δe/e0 = 0.12Which Cc to use, and why?GivenSample A: Cc = 0.45; Δe/e0 = 0.06 (good to fair)Sample B: Cc = 0.31; Δe/e0 = 0.12 (poor)Lunne et al. (1997) SQDRequiredWhich Cc to useWhyBlack = given; red = required
Given and required for Question 5.2-3.

Given

VariableValueDescription
Sample ACc = 0.45; Δe/e0 = 0.06, good to fairLunne et al. (1997) SQD
Sample BCc = 0.31; Δe/e0 = 0.12, poor

Required

  • Which Cc to use, and why

Equations

No equation is needed; the answer follows from the criteria listed under Given.

Steps

Step 1 · What does disturbance do?
It rounds the curve, hides σ′p and flattens the virgin line, lowering the measured Cc.
↓
Step 2 · Effect on design
The poor sample would underestimate settlement: unconservative.
↓
Step 3 · Choice
Use Sample A; record why Sample B was rejected.
↓
Solution
Use Cc = 0.45 from Sample A.

Solution

Use Cc = 0.45 from Sample A.

Disturbance always errs toward less compressible behavior beyond σ′p, so the lower value is the suspect one. Document the rejection with the SQD criteria in the report.

Question 5.2-4: Effective Friction Angle From Three CU Tests

Problem Statement

Three consolidated-undrained triaxial tests were run on clay from the foundation of a railroad embankment that is to be widened. The confining pressures, deviator stresses and pore pressures at failure are shown. The engineer must find the effective stresses at failure and the effective friction angle for the widening’s drained stability analysis.

The same method as Example 5.2-3.

0200040006000800001000200030004000Normal stress σ′ (psf)Shear stress (psf)σ′3, σ′1, φ′ = ?Givenσ3 = 1,000; 2,000; 3,000 psf(σ1−σ3)f = 1,840; 3,280; 4,920 psfuf = 450; 820; 1,200 psfRequired(a) σ′3 (b) σ′1 (c) φ′Black = given; red = required
Given and required for Question 5.2-4.

Given

VariableValueDescription
σ31,000; 2,000; 3,000 psf
(σ1 − σ3)f1,840; 3,280; 4,920 psf
uf450; 820; 1,200 psf

Required

  • (a) σ′3
  • (b) σ′1
  • (c) φ′

Equations

  1. Eq. 1: σ′3 = σ3 − uf; σ′1 = σ′3 + (σ1 − σ3)
  2. Eq. 2: sinφ′ = Δq / Δp′ — slope of the p′-q line

Steps

Step 1 · (a) σ′3
550; 1,180; 1,800 psf
↓
Step 2 · (b) σ′1
2,390; 4,460; 6,720 psf
↓
Step 3 · Radii and centers
q = 920, 1,640, 2,460; p′ = 1,470, 2,820, 4,260 psf
↓
Step 4 · (c) φ′
(2,460 − 920)/(4,260 − 1,470) = 1,540/2,790
sinφ′ = 0.552; φ′ = 33.5°
↓
Solution
φ′ ≈ 33.5°.

Solution

(a) 550, 1,180 and 1,800 psf. (b) 2,390, 4,460 and 6,720 psf. (c) φ′ ≈ 33.5°.

The middle point lies close to the line through the outer two (predicted q = 920 + 0.552 × 1,350 = 1,665 psf against 1,640), so the three specimens are consistent.

Question 5.2-5: Reducing a Soaked CBR Test

Problem Statement

A soaked CBR test was run on the proposed subballast borrow for a Class I railroad siding. The test gave the loads shown at 0.1 and 0.2 in. of penetration, with a seating load. The engineer must correct the loads, compute the CBR and report the design value.

0.10.20.30.450010001500Penetration (in.)Load (lb)880 lb1,260 lbseating 15 lbCorrected loads, CBR = ?Given880 lb at 0.1 in.; 1,260 lb at 0.2 in.Seating 15 lb at zero penetrationStandard 3,000 and 4,500 lbSubballast borrow, sidingRequired(a) Corrected loads(b) CBR at 0.1 and 0.2 in.(c) Design CBRBlack = given; red = required
Given and required for Question 5.2-5.

Given

VariableValueDescription
Loads880 lb at 0.1 in.; 1,260 lb at 0.2 in.
Seating15 lb at zero penetration
Standard loads3,000 and 4,500 lb

Required

  • (a) Corrected loads
  • (b) CBR at 0.1 and 0.2 in.
  • (c) Design CBR

Equations

  1. Eq. 1: CBR = (P − Pseat) / Pstd × 100%

Steps

Step 1 · (a) Corrected loads
865 lb and 1,245 lb
↓
Step 2 · (b) CBR
865/3,000; 1,245/4,500
28.8% and 27.7%
↓
Step 3 · (c) Design
0.1 in. governs: 28.8%
↓
Solution
Design CBR = 28.8%.

Solution

(a) 865 and 1,245 lb. (b) 28.8% and 27.7%. (c) Design CBR = 28.8%.

If the 0.2-in. value had been higher, ASTM D1883 calls for a repeat test; a higher value at 0.2 in. usually means a seating error at low penetration.

Question 5.2-6: Corrosivity Screening for a Soldier Pile Wall

Problem Statement

A soldier pile and lagging wall will support a cut beside a yard track for a Class I railroad located in Indiana. The piles pass through clean fill above the water table and old cinder fill below it. Corrosivity tests on one sample from each zone have come back from the laboratory. The engineer must decide whether either zone is aggressive to the steel piles, which results govern, and what to ask the laboratory about its procedure before finalizing the design (Section 5.2.30).

Upper fill,above water table Old cinder fill,below water table Soldier pile 12 Given: sample B-1 (upper fill) pH 6.8; resistivity 4,200 ohm-cmChloride 45 ppm; sulfate 150 ppmOrganic content 0.6% Given: sample B-2 (cinder fill) pH 4.6; resistivity 1,800 ohm-cmChloride 160 ppm; sulfate 820 ppm*Organic content 3.5%; Eh −120 mV *Sample oven-dried at 200°F before the sulfate test Required: classify each zone; response
Figure 5.2-15. Question 5.2-6: soldier pile through two fill zones, with test results.

Given

VariableValueDescription
B-1, upper fillpH 6.8; 4,200 ohm-cm; Cl 45 ppm; SO4 150 ppm; organics 0.6%Above the water table
B-2, cinder fillpH 4.6; 1,800 ohm-cm; Cl 160 ppm; SO4 820 ppm; organics 3.5%; Eh −120 mVBelow the water table; sulfate sample oven-dried at 200°F

Required

  • (a) Whether each zone is aggressive by the screening criteria
  • (b) Which results govern for B-2 and why redox matters
  • (c) What to question about the laboratory procedure, and the design response

Equations

  1. Screen (Section 5.2.30.3): aggressive if pH < 5 or pH > 10
  2. ρ < 3,000 ohm-cm
  3. Cl > 100 ppm
  4. SO4 > 200 ppm
  5. organic content > 1%

Steps

Step 1 · (a) B-1
pH 6.8 (5 to 10); 4,200 > 3,000; 45 < 100; 150 < 200; 0.6% < 1%
Not aggressive: passes all five
↓
Step 2 · (a) B-2
pH 4.6 < 5; 1,800 < 3,000; 160 > 100; 820 > 200; 3.5% > 1%
Aggressive: fails all five
↓
Step 3 · (b) Governing results
Low pH and resistivity drive general corrosion; Eh of −120 mV means reducing conditions in saturated organic cinders
Expect fast and possibly pitting corrosion by sulfate-reducing bacteria
Spot check: Even if drying had raised the sulfate result by 47%, the true value would be about 820/1.47 = 560 ppm, still well above 200 ppm: the classification does not change.
↓
Step 4 · (c) Procedure and response
Ask the method, extraction ratio and drying temperature; was B-2 sealed and tested promptly?
Design the piles for aggressive ground in the cinder zone
↓
Solution
B-1 not aggressive; B-2 aggressive on every criterion; design for aggressive ground below the water table.

Solution

(a) B-1 is not aggressive; B-2 is aggressive on all five criteria. (b) pH, resistivity and the reducing (low Eh) conditions govern; sulfate and chloride confirm it. (c) Question the oven-drying of the sulfate sample and confirm the methods, but the conclusion stands.

Design the steel for the cinder zone, not the average: options include a sacrificial thickness or heavier section based on an aggressive-ground loss rate, coatings over the length in the cinder fill, concrete encasement of the embedded pile, or a different wall type. Treat lagging and connections the same way. Take more samples along the wall alignment, because old cinder fills vary, and keep a sealed, unopened sample from below the water table for redox and sulfide testing. Disposal of excavated cinder fill may also need environmental testing (Chapter 5.4).

5.2.16 Case Studies

Field case studies by Burt G. Look, from Earthworks: Theory to Practice – Design and Construction (CRC Press/Balkema, 2023), chosen for this chapter’s topics. Each is summarized from the book with its key figures and a closing note on railroad application added by the authors of this manual. Credit for the case material belongs to Look; see item S8 under Supplemental References.

Case Study 10.16.1 — Curing time changes compaction and CBR results
Case study · Look (2023) §5.8

Related section: 5.2.3 Test Methods — ASTM Standards and English Unit Outputs

Samples of Bundamba clay (plasticity index 47%, 97% passing No. 40, 69%–82% fines) were cured for 0, 1, 4 and 7 days before compaction and soaked and unsoaked CBR testing:

  • Short curing gave a higher maximum dry density, so the field material is more likely to fail its density ratio or need extra compactive effort.
  • Short curing gave higher CBR swell, which would trigger more remove-and-replace than is needed (typically 10 in. for the swell measured). Whether the sample arrived wet or dry also changed the swell when curing was inadequate.
  • Short curing gave a higher unsoaked CBR (thinner pavement, more long-term failures) and a lower soaked CBR (over-designed pavement).

For railroad work: plastic clay subgrade samples for CBR, resilient modulus or Proctor testing should be cured to the period the test standard requires, and the curing time should be reported. A test turned around too quickly can push the design either way.

Curing 0–1 days gave a higher MDD than 4–7 days for a high-plasticity clay.
Figure 10-LK1. Curing 0–1 days gave a higher MDD than 4–7 days for a high-plasticity clay. Source: Look (2023), Figure 5.8-1, p. 143.
Curing time against soaked CBR and swell: short curing lowers soaked CBR and raises swell.
Figure 10-LK2. Curing time against soaked CBR and swell: short curing lowers soaked CBR and raises swell. Source: Look (2023), Figure 5.9-1, p. 143.

Source: Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press/Balkema. Case study §5.8, pp. 142. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.

Case Study 10.16.2 — Laboratory variation in Cooroy clay compaction curves
Case study · Look (2023) §7.9

Related section: 5.2.5 Laboratory QA/QC

Eleven standard compaction tests on clay from one project site at Cooroy, Queensland (55 compaction points) gave maximum dry densities from 97–104 pcf, median about 101 pcf, and optimum moisture contents from 18.6% to 24.5%, median 21.5%. The idea of a unique MDD and OMC does not hold for clays. The repeatability allowed in the Australian standard suggests 85%–115% of OMC as a realistic moisture window, yet many specifications ask for ±2% of OMC, which testing variation alone makes unachievable.

The real target is low air voids: much below 85% of OMC, air voids exceed about 10%. Look also warns that the compacted soil will not stay at its placement moisture, so the moisture target should guide field effort and not be a pass/fail criterion. Density is the pass/fail measure. Compaction well above MDD or dry of OMC raises suction, so the “stronger” material is more sensitive to later moisture change.

For railroad work: the ±2% moisture band suits processed granular materials such as subballast, not high-moisture clays in embankment or subgrade. Use a band that reflects the laboratory’s own repeatability.

Individual five-point compaction curves for 11 samples of Cooroy clay: MDD 97–104 pcf, OMC 18.6%–24.5%.
Figure 10-LK3. Individual five-point compaction curves for 11 samples of Cooroy clay: MDD 97–104 pcf, OMC 18.6%–24.5%. Source: Look (2023), Figure 7.9-1, p. 233.

Source: Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press/Balkema. Case study §7.9, pp. 230–232. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.

5.2.17 Reducing Shear Strength Test Results

The library's notes on the Mohr-Coulomb model and on drained and undrained strength cover how a set of triaxial or direct shear specimens becomes a design envelope. The common error in railroad reports is to fit c and φ to too few specimens, or to report a peak effective cohesion for a clay slope that will, over decades, soften toward zero cohesion. The calculator fits the envelope by least squares and states the fit quality so the scatter is visible.

5.2.17.1 Method

Equation 5.2-1. Triaxial results in p-q space

p = (σ1 + σ3)/2,  q = (σ1 − σ3)/2 at failure;  q = a + p tanα  →  sinφ = tanα,  c = a/cosφ

Equation 5.2-2. Direct shear

τf = c + σn tanφ fitted by least squares
Table 5.2-9. Choosing the strength for the problem
ConditionTest and strengthRailroad example
End of construction or rapid loading of saturated clayUU or CU total stress: su (φ = 0)New fill placed quickly on soft clay
Long term, drainedCU with pore pressure or CD: c', φ'Cut slopes and old embankments
Clay slopes that have softenedFully softened (c' ≈ 0)Over-steepened fill slopes in fat clay
Pre-existing slide surfaceResidual (ring or reversal shear)Reactivated slides at a track realignment

5.2.17.2 Worked example: CU triaxial on embankment clay

Three consolidated-undrained specimens with pore pressure measurement (effective σ3 of 10, 20 and 40 psi) give φ' = 29.3 deg and c' = 2.78 psi with r² = 1.000. For a long-term slope check the 2.8-psi cohesion (about 400 psf) should be justified or dropped toward the fully softened value. On a 5-ft-deep slide in a dry 2H:1V slope with this friction angle, the Chapter 6.3 calculator gives a factor of safety of 1.12 with c' = 0 and 2.79 with c' = 400 psf, so the cohesion, not the friction angle, decides the answer.

Open the shear strength calculator →
Mohr-Coulomb c and φ from triaxial (σ3, σ1) or direct shear (σn, τ) results, with Mohr circles, fit quality and strength at a design normal stress.

5.2.17.3 Sources in the library

These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.

  • Soil Shear Strength: Mohr-Coulomb and Soil Shear Strength: The Friction Model (course notes), Shear Strength folder.Find source ↗Library entry
  • Undrained and Drained Shear Strength (notes), Geotechnical Principles folder.Find source ↗Library entry
  • Fundamentals of Geotechnical Engineering (Shear Strength folder) and Soil Mechanics Laboratory Manual.Find source ↗
5.2.18 Ballast Acceptance Testing to AREMA Limits

Ballast is bought to a specification, and acceptance rests on two sets of laboratory results: the gradation, compared with the recommended band for the specified size number, and the physical tests, compared with limiting values that depend on the rock type. AREMA Chapter 1, Part 2, publishes both tables. The tests screen out rock that breaks down, absorbs water, carries clay or fines into the track, or packs poorly. Conference papers in the library show how petrography and field imaging extend these tests where a quarry's rock is marginal.

5.2.18.1 Limits

Table 5.2-10. Recommended ballast gradations (AREMA Table 1-2-2), percent passing
Size No.3 in.2 1/221 1/213/41/23/8No. 4No. 8
2410090–10025–600–100–5
2510080–10060–8550–7025–505–200–100–3
310095–10035–700–150–5
4A10090–10060–9010–350–100–3
410090–10020–550–150–5
510090–10040–7515–350–150–5
5710095–10025–600–100–5

Nos. 24, 25, 3, 4A and 4 are main line ballast; Nos. 5 and 57 are yard ballast.

Table 5.2-11. Limiting test values (AREMA Table 1-2-1)
Property (ASTM)Granite, traprockQuartziteLimestoneDolomitic limestone
Passing No. 200, max (C 117)1.0%1.0%1.0%1.0%
Bulk specific gravity, min (C 127)2.602.602.602.65
Absorption, max (C 127)1.0%1.0%2.0%2.0%
Clay lumps and friable particles, max (C 142)0.5%0.5%0.5%0.5%
LA abrasion, max (C 535 or C 131)35%30%30%30%
Sodium sulfate soundness, 5 cycles, max (C 88)5.0%5.0%5.0%5.0%
Flat or elongated, max (D 4791 Method A)5.0%5.0%5.0%5.0%

Use ASTM C535 for gradations with particles retained on the 1 in. sieve and C 131 for gradations passing 1 in. For concrete tie track AREMA excludes carbonate rock and gradation No. 57.

5.2.18.2 Worked example: two shipments of No. 4A

Table 5.2-12. Calculator results
SampleGradationTestsResult
Granite: 96% passing 2 in., 72% at 1 1/2, 22% at 1, 6% at 3/4, 2% at 3/8; LA 24%conformsall within limitsacceptable
Limestone, finer: 40% passing 1 in., 12% at 3/4, 3% at 3/8; LA 32%does not conform (1 in. and 3/4 in. sieves high)LA abrasion over 30%not acceptable

The second shipment fails on both counts: it is too fine for No. 4A and the limestone is softer than the 30% LA limit allows. Fine, soft ballast breaks down faster and fouls sooner (Chapter 6.4), so rejection at the quarry costs far less than early undercutting.

Open the ballast acceptance calculator →
Sieve analysis against the AREMA band for the size number, plus the limiting test values for the rock type and the concrete-tie exclusions.

5.2.18.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated limits are standard or published values. Individual railroads are not named.

  • AREMA Manual for Railway Engineering, Chapter 1 (2019 edition), Part 2 Ballast: Tables 1-2-1 and 1-2-2, concrete tie restrictions.Official page ↗
  • AREMA conference paper (2014): petrographic evaluation of ballast suitability, a case study.Find source ↗
  • AREMA conference paper (2021): testing and characterization of dolomite aggregate for ballasted track on a new passenger line.Find source ↗
  • AREMA conference papers (2015, 2018): ballast properties and degradation trends; principles of degraded ballast and track safety.Find source ↗
5.2.19 Consolidated-Undrained Triaxial Tests: Pore Pressure, Stress Paths and Strength

Consolidated-undrained (CU) triaxial tests with pore pressure measurement are the workhorse strength test for clay foundations under embankments. One set of tests gives both the undrained strength for short-term stability and the effective stress parameters for long-term stability. Das's Principles of Geotechnical Engineering shows how to reduce the results. Each failure point is plotted as p = (σ1 + σ3)/2 against q = (σ1 − σ3)/2. A straight line through the points (the Kf line, q = m + p tan α) converts to the Mohr–Coulomb parameters through sin φ = tan α and c = m/cos φ. Skempton's pore pressure coefficient at failure, Af, shows whether the clay tends to contract or dilate when sheared. Budhu and Craig give the critical state view of the same tests. Das also gives Skempton's correlation between the field vane strength ratio and plasticity index, with an overconsolidation adjustment, as a check on the laboratory values.

5.2.19.1 Method

Equation 5.2-3. Kf line, Skempton's A and field vane estimate

q = m + p tan α;   sin φ = tan α;   c = m / cos φ  (total stresses for φcu, effective for φ′)

Af = (Δud)f / (Δσd)f
(cu(VST)/σ′0)NC = 0.11 + 0.0037PI;   (cu(VST)/σ′0)OC = (cu(VST)/σ′0)NC(OCR)0.8

Table 5.2-13. Verification against Das, Examples 12.6 to 12.8
QuantityDasCalculator
φcu, one specimen: σ3 = 12 psi, (Δσd)f = 9.1 psi, (Δud)f = 6.8 psi16°16.0°
φ′, same specimen27.8°27.8°
Drained deviator stress at σ′3 = 12 psi21 psi21.0 psi
Field vane strength, PI = 28, OCR = 3.2, σ′0 = 160 kPa (3,342 psf)86.7 kPa (1,811 psf)1,810 psf

5.2.19.2 Worked example

Three CU tests on a clay at cell pressures of 10, 20 and 30 psi give a best-fit Kf line of φ′ = 36.1° with c′ = 0.69 psi, and a total stress angle φcu = 20.5°. These are illustrative results, not data from a real site. The mean Af is 0.49. Use φ′ and c′ for long-term embankment stability, and the undrained strength ratio for the end of construction and for staged construction (Chapter 2.5). A field vane strength well below the laboratory value usually points to sample disturbance, not to weak clay; check it with Chapter 4.1.

Check saturation (Skempton's B-value) before shearing and report it with the results. If Af values scatter widely between specimens, the pore pressure measurements are suspect, and so is φ′.

Open the CU triaxial calculator →
Total and effective stress Kf lines from CU tests with pore pressure, Mohr-Coulomb parameters, Skempton's Af, the implied drained strength, and a field vane strength estimate from PI and OCR, with a p-q plot.

5.2.19.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.

  • B.M. Das, Principles of Geotechnical Engineering, 7th edition: Chapter 12, CU tests, Examples 12.6 to 12.9, stress paths and the Kf line, and Skempton's vane strength relationFind source ↗
  • M. Budhu, Soil Mechanics and Foundations, 3rd edition: stress paths, pore pressure parameters and critical state interpretationFind source ↗
  • R.F. Craig, Craig's Soil Mechanics, 7th edition: triaxial testing and pore pressure coefficientsFind source ↗Library entry
5.2.20 Reducing Oedometer Readings: Coefficient of Consolidation and Permeability

The settlement-rate calculations in Chapters 6.2, 7.2 and 2.5 all start from cv, and cv comes from fitting the time readings of each oedometer load increment to Terzaghi's theory. Craig's Soil Mechanics (Section 7.8) describes both standard fits. Casagrande's log time method finds the start of primary consolidation from the parabolic early part of the curve, and the end where the steep and secondary parts meet, then reads t50. Taylor's root time method draws a line with abscissae 1.15 times those of the straight early part and reads t90 where it meets the curve. Craig notes that the root time method needs shorter readings but does not always show a straight line. The same increment also gives mv, and from mv and cv the permeability. He also warns that small laboratory specimens often understate field cv, because they miss the silt layers and fissures that drain a clay in the field.

5.2.20.1 Method

Equation 5.2-4. Curve fitting and derived properties (Craig Eqs. 7.26 to 7.31)

Log time: cv = 0.196d²/t50;   root time: cv = 0.848d²/t90 (d = half the average specimen thickness, two-way drainage)

r0 = (a0 − as)/(a0 − af);   rp = 10(as − a90)/[9(a0 − af)];   rs = 1 − r0 − rp
mv = Δe/[(1 + e0)Δσ′];   k = cvmvγw

The calculator automates both constructions. For the root time plot it finds the longest straight run of early readings (R² above 0.997) and intersects the 1.15 line with the readings. For the log time plot it takes the corrected zero from the readings at t and 4t, and the end of primary consolidation where the steepest segment meets a line through the last three readings. Hand constructions differ from person to person, and so does this one, by a few percent.

Table 5.2-14. Verification against Craig
QuantityCraigCalculator
Example 7.4: t90 (root time)53.3 min54.5 min
Example 7.4: cv, root time / log time0.46 / 0.45 m²/yr0.45 / 0.49 m²/yr
Example 7.4: r0, rp0.080, 0.7850.083, 0.784
Example 7.4: mv0.70 m²/MN0.70 m²/MN
Problem 7.1: cv, root time / log time2.7 / 2.6 m²/yr2.77 / 2.58 m²/yr
Problem 7.1: mv0.98 m²/MN0.98 m²/MN
Problem 7.1: k8.1 × 10−10 m/s8.5 × 10−10 m/s

The log time value for Example 7.4 is about 9% higher than Craig's because the calculator's tangent at the steepest segment falls slightly differently from his hand construction.

5.2.20.2 Worked example

Craig's Example 7.4 increment, 214 to 429 kPa (4,469 to 8,960 psf), gives cv of 0.013 ft²/day by root time and 0.014 ft²/day by log time, with t90/t50 of 54.5 / 11.6 min. Secondary compression makes up about 13% of the compression in the increment. The permeability back-figured from cv and mv is 9.66 × 10−9 cm/s, typical of a clay. When this cv is used for a preload or wick drain design, compare it with field ch from CPTu dissipation tests (Chapter 5.1). The laboratory value is often the lower of the two.

Report cv for the load increment that brackets the field stresses, not an average over the whole test. Where the root time plot shows no straight line, or secondary compression swamps the primary part (organic clays, peat), use the log time method and say so in the report.

Open the oedometer curve fitting calculator →
Root time (Taylor) and log time (Casagrande) curve fitting of an oedometer load increment, compression ratios, mv and permeability, in either mm or inch dial units.

5.2.20.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.

  • R.F. Craig, Craig's Soil Mechanics, 7th edition: Section 7.8, determination of the coefficient of consolidation, compression ratios, Example 7.4 and Problem 7.1Find source ↗Library entry
  • B.M. Das, Principles of Geotechnical Engineering, 7th edition: one-dimensional consolidation testingFind source ↗
  • P.J. Sabatini and others, Evaluation of Soil and Rock Properties, FHWA Geotechnical Engineering Circular No. 5: consolidation properties and their variabilityFind source ↗Library entry
5.2.21 Phase Relationships of Soil

Almost every laboratory and field result is reported through the weight-volume (phase) relationships of soil: a moisture content and a unit weight from a tube sample give the void ratio for a settlement calculation; a field density test gives the dry unit weight for a compaction check; an assumed porosity gives the saturated and buoyant weights for a slope or a retaining wall. The relationships are simple, but they are easy to mix up, and an inconsistent set (degree of saturation over 100%, for example) is a common sign of a wrong specific gravity or a bad density test.

5.2.21.1 Method

Equation 5.2-5. Phase relationships

e = Vv/Vs;   n = e/(1 + e);   w = Ww/Ws;   Se = wGs;   γd = Gsγw/(1 + e) = γ/(1 + w);   γ = (Gs + Se)γw/(1 + e);   γ′ = (Gs − 1)γw/(1 + e);   ic = (Gs − 1)/(1 + e)

Vv = volume of voids (air plus water); Vs = volume of solids; S = degree of saturation; Gs = specific gravity of solids (ASTM D854); γw = 62.4 pcf; ic = critical hydraulic gradient for a quick condition under upward flow.

5.2.21.2 Worked example

Example 5.2-4: Phase Properties of a Tube Sample

A specimen trimmed from a tube sample of embankment fill is weighed, oven-dried and weighed again. Its bulk specific gravity was measured by immersion. The numbers are those of the soil composition example in Hicks (2000).

air Va = ?water 18 gsolids 104 gGs = 2.53W = 122 gGm = 1.82Phase diagram of the specimenGivenW = 122 g moistWs = 104 g oven-dryGm = 1.82; Gs = 2.53Requirede, n, w, Sγd, γsat, γ′Critical gradient ic
Phase diagram of the trimmed specimen: air, water and solids by volume.

Given

VariableValueDescription
W122 gMoist weight
Ws104 gOven-dry weight
Gm1.82Bulk specific gravity of the moist mass
Gs2.53Specific gravity of solids

Required

  • Void ratio, porosity, water content and degree of saturation
  • Dry, saturated and submerged unit weights
  • Critical gradient

Equations

  1. Eq. 5.2-5: V = W/Gm; Vs = Ws/Gs; Vw = W − Ws — volumes in cm³
  2. Eq. 5.2-5: e = (V − Vs)/Vs; w = Ww/Ws; S = Vw/Vv
  3. Eq. 5.2-5: γd, γsat, γ′, ic

Steps

Step 1 · Volumes
V = 122/1.82; Vs = 104/2.53; Vw = 18
V = 67.0 cm³; Vs = 41.1 cm³; Vw = 18.0 cm³; Va = 7.9 cm³
↓
Step 2 · Ratios
e = 25.9/41.1; n = 25.9/67.0; w = 18/104; S = 18.0/25.9
e = 0.631; n = 38.7%; w = 17.3%; S = 69.4%
Spot check: Se = 0.694 × 0.631 = 0.438 and wGs = 0.173 × 2.53 = 0.438: consistent. Hicks reports 63.0%, 38.7%, 17.3% and 69.5%.
↓
Step 3 · Unit weights
γd = 2.53 × 62.4/1.631; γsat = (2.53 + 0.631)62.4/1.631
γd = 96.8 pcf; γsat = 120.9 pcf; γ′ = 58.5 pcf
↓
Step 4 · Critical gradient
(2.53 − 1)/1.631
ic = 0.94
↓
Solution
e = 0.631, n = 38.7%, w = 17.3%, S = 69.4%; γd = 96.8 pcf.

Solution

The sample has a void ratio of 0.631 at 17.3% water content and 69% saturation, and a dry unit weight of 96.8 pcf.

A Gs of 2.53 is low for mineral soil and suggests some organic matter or light particles (for example cinders in an old track fill). If Gs is assumed rather than measured, check it: with 2.70 the same weights give e = 0.74 and S = 63%, a material difference for settlement estimates.

Open the phase relationships calculator →
Void ratio, porosity, water content, saturation and unit weights from a lab specimen, from field unit weight and water content, or from void ratio, with the critical gradient and a seepage check.

5.2.21.3 Sources

The summaries above are paraphrased in original wording; equations and tabulated values are standard or published. Individual railroads, clients, companies and projects are not named.

5.2.22 ASTM Soil and Rock Standards Cross-Reference

Laboratory and field test results in this manual cite ASTM standard numbers. This table lists every active standard published in ASTM Volumes 04.08 and 04.09 (Soil and Rock) as of the 2010 subject index, grouped by purpose, so a test name in a proposal, a lab report or a specification can be matched to its designation. The 55 standards marked ★ are the ones used most often in railroad geotechnical work. Standards are revised on a five-year cycle and some have been replaced since 2010 (for example, D422 by D6913 and D7928, and D2938, D2664 and others by D7012), so confirm the current edition at astm.org before citing one in a scope or specification.

Table 5.2-15. ASTM soil and rock standards (Volumes 04.08 and 04.09), 376 active standards, edition shown as of 2010
DesignationEditionTitleVol.
Classification and index properties (33)
D422 ★63(2007)Test Method for Particle-Size Analysis of Soils04.08
D42588(2008)Test Method for Centrifuge Moisture Equivalent of Soils04.08
D854 ★06ε1Test Methods for Specific Gravity of Soil Solids by Water Pycnometer04.08
D1140 ★00(2006)Test Methods for Amount of Material in Soils Finer than No. 200 (75-µm) Sieve04.08
D2487 ★06ε1Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)04.08
D2488 ★09aPractice for Description and Identification of Soils (Visual-Manual Procedure)04.08
D2974 ★07aTest Methods for Moisture, Ash, and Organic Matter of Peat and Other Organic Soils04.08
D2976 ★71(2004)Test Method for pH of Peat Materials04.08
D297703Test Method for Particle Size Range of Peat Materials for Horticultural Purposes04.08
D297803Test Method for Volume of Processed Peat Materials04.08
D298004Test Method for Volume Mass, Moisture-Holding Capacity, and Porocity of Saturated Peat Materials04.08
D328209Practice for Classification of Soils and Soil-Aggregate Mixtures for Highway Construction Purposes04.08
D422199(2005)Test Method for Dispersive Characteristics of Clay Soil by Double Hydrometer04.08
D4318 ★05Test Methods for Liquid Limit, Plastic Limit, and Plasticity Index of Soils04.08
D454486(2008)Practice for Estimating Peat Deposit Thickness04.08
D464308Test Method for Determination of Water (Moisture) Content of Soil by Microwave Oven Heating04.08
D464706ε1Test Method for Identification and Classification of Dispersive Clay Soils by the Pinhole Test04.08
D494308Test Method for Shrinkage Factors of Soils by the Wax Method04.08
D494404Test Method for Field Determination of Water (Moisture) Content of Soil by the Calcium Carbide Gas Pressure Tester04.08
D495907Test Method for Determination of Water (Moisture) Content of Soil By Direct Heating04.08
D4972 ★01(2007)Test Method for pH of Soils04.08
D523904Practice for Characterizing Fly Ash for Use in Soil Stabilization04.08
D5519 ★07Test Methods for Particle Size Analysis of Natural and Man-Made Riprap Materials04.08
D555006Test Method for Specific Gravity of Soil Solids by Gas Pycnometer04.08
D571500(2006)Test Method for Estimating the Degree of Humification of Peat and Other Organic Soils (Visual/Manual Method)04.08
D572095(2009)Practice for Static Calibration of Electronic Transducer-Based Pressure Measurement Systems for Geotechnical Purposes04.08
D585200(2007)Test Method for Erodibility Determination of Soil in the Field or in the Laboratory by the Jet Index Method04.08
D602606Practice for Using Significant Digits in Geotechnical Data04.09
D602796(2004)Practice for Calibrating Linear Displacement Transducers for Geotechnical Purposes04.09
D627699a(2006)ε1Test Method for Using pH to Estimate the Soil-Lime Proportion Requirement for Soil Stabilization04.09
D656500(2005)Test Method for Determination of Water (Moisture) Content of Soil by the Time-Domain Reflectometry (TDR) Method04.09
D657206Test Methods for Determining Dispersive Characteristics of Clayey Soils by the Crumb Test04.09
D6913 ★04(2009)Test Methods for Particle-Size Distribution (Gradation) of Soils Using Sieve Analysis04.09
Compaction, density and field control (28)
D55804Test Methods for Moisture-Density (Unit Weight) Relations of Soil-Cement Mixtures04.08
D55903Test Methods for Wetting and Drying Compacted Soil-Cement Mixtures04.08
D56003Test Methods for Freezing and Thawing Compacted Soil-Cement Mixtures04.08
D698 ★07ε1Test Methods for Laboratory Compaction Characteristics of Soil Using Standard Effort (12 400 ft-lbf/ft3 (600 kN-m/m3))04.08
D1556 ★07Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method04.08
D1557 ★09Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft3 (2,700 kN-m/m3))04.08
D188307ε2Test Method for CBR (California Bearing Ratio) of Laboratory- Compacted Soils04.08
D216708Test Method for Density and Unit Weight of Soil in Place by the Rubber Balloon Method04.08
D216802aTest Methods for Calibration of Laboratory Mechanical-Rammer Soil Compactors04.08
D2844 ★07Test Method for Resistance R-Value and Expansion Pressure of Compacted Soils04.08
D2937 ★04Test Method for Density of Soil in Place by the Drive-Cylinder Method04.08
D4253 ★00(2006)Test Methods for Maximum Index Density and Unit Weight of Soils Using a Vibratory Table04.08
D4254 ★00(2006)ε1Test Methods for Minimum Index Density and Unit Weight of Soils and Calculation of Relative Density04.08
D438084(2006)Test Method for Density of Bentonitic Slurries04.08
D453186(2008)Test Methods for Bulk Density of Peat and Peat Products04.08
D456408Test Method for Density and Unit Weight of Soil in Place by the Sleeve Method04.08
D471887(2007)Practice for Correction of Unit Weight and Water Content for Soils Containing Oversize Particles04.08
D508008Test Method for Rapid Determination of Percent Compaction04.08
D510209Test Methods for Unconfined Compressive Strength of Compacted Soil-Lime Mixtures04.08
D585695(2007)Test Method for Measurement of Hydraulic Conductivity of Porous Material Using a Rigid-Wall, Compaction-Mold Permeameter04.08
D602307Test Method for Density (Unit Weight), Yield, Cement Content, and Air Content (Gravimetric) of Controlled Low-Strength Material (CLSM)04.09
D603508Test Method for Determining the Effect of Freeze-Thaw on Hydraulic Conductivity of Compacted or Intact Soil Specimens Using a Flexible Wall Permeameter04.09
D668308Test Method for Measuring Bulk Density Values of Powders and Other Bulk Solids as Function of Compressive Stress04.09
D678005Test Method for Water Content and Density of Soil in Place by Time Domain Reflectometry (TDR)04.09
D6938 ★08aTest Method for In-Place Density and Water Content of Soil and Soil-Aggregate by Nuclear Methods (Shallow Depth)04.09
D701304Guide for Nuclear Surface Moisture and Density Gauge Calibration Facility Setup04.09
D726309Test Methods for Laboratory Determination of Density (Unit Weight) of Soil Specimens04.09
D738208Test Methods for Determination of Maximum Dry Unit Weight and Water Content Range for Effective Compaction of Granular Soils Using a Vibrating Hammer04.09
Strength and deformation (21)
D163300(2007)Test Methods for Compressive Strength of Molded Soil-Cement Cylinders04.08
D163400(2006)Test Method for Compressive Strength of Soil-Cement Using Portions of Beams Broken in Flexure (Modified Cube Method)04.08
D2166 ★06Test Method for Unconfined Compressive Strength of Cohesive Soil04.08
D2850 ★03a(2007)Test Method for Unconsolidated-Undrained Triaxial Compression Test on Cohesive Soils04.08
D3080 ★04Test Method for Direct Shear Test of Soils Under Consolidated Drained Conditions04.08
D399991(2003)Test Methods for the Determination of the Modulus and Damping Properties of Soils Using the Cyclic Triaxial Apparatus04.08
D401507Test Methods for Modulus and Damping of Soils by Resonant- Column Method04.08
D421908Test Method for Unconfined Compressive Strength Index of Chemical-Grouted Soils04.08
D4429 ★09aTest Method for CBR California Bearing Ratio of Soils in Place __04.08
D472908Test Method for In Situ Stress and Modulus of Deformation Using Flatjack Method04.08
D4767 ★04Test Method for Consolidated Undrained Triaxial Compression Test for Cohesive Soils04.08
D520208Test Method for Determining Triaxial Compression Creep Strength of Chemical Grouted Soils04.08
D531192(2004)ε1Test Method for Load Controlled Cyclic Triaxial Strength of Soil04.08
D587402(2007)Test Method for Determination of the Impact Value (IV) of a Soil04.08
D612806Test Method for Shear Testing of Bulk Solids Using the Jenike Shear Cell04.09
D646706aTest Method for Torsional Ring Shear Test to Determine Drained Residual Shear Strength of Cohesive Soils04.09
D652807Test Method for Consolidated Undrained Direct Simple Shear Testing of Cohesive Soils04.09
D668208Test Method for Measuring Shear Stresses of Powders Using Peschl Rotational Split Level Shear Tester04.09
D675808Test Method for Measuring Stiffness and Apparent Modulus of Soil and Soil-Aggregate In-Place by Electro-Mechanical Method04.09
D677308Test Method for Bulk Solids Using Schulze Ring Shear Tester04.09
D720705Test Method for Determination of Unvegetated Rolled Erosion Control Product (RECP) Ability to Protect Sand from Hydraulically-Induced Shear Stresses under Bench-Scale Conditions04.09
Consolidation, swell and collapse (9)
D2435 ★04Test Methods for One-Dimensional Consolidation Properties of Soils Using Incremental Loading04.08
D387708Test Methods for One-Dimensional Expansion, Shrinkage, and Uplift Pressure of Soil-Lime Mixtures04.08
D408389(2007)Practice for Description of Frozen Soils (Visual-Manual Procedure)04.08
D418606Test Method for One-Dimensional Consolidation Properties of Saturated Cohesive Soils Using Controlled-Strain Loading04.08
D4546 ★08Test Methods for One-Dimensional Swell or Collapse of Cohesive Soils04.08
D4829 ★08aTest Method for Expansion Index of Soils04.08
D533303Test Method for Measurement of Collapse Potential of Soils04.08
D591806Test Methods for Frost Heave and Thaw Weakening Susceptibility of Soils04.09
D730006Test Method for Laboratory Determination of Strength Properties of Frozen Soil at a Constant Rate of Strain04.09
Permeability and suction (11)
D2434 ★68(2006)Test Method for Permeability of Granular Soils (Constant Head)04.08
D451100(2006)Test Method for Hydraulic Conductivity of Essentially Saturated Peat04.08
D452508Test Method for Permeability of Rocks by Flowing Air04.08
D463096(2008)Test Method for Determining Transmissivity and Storage Coefficient of Low-Permeability Rocks by In Situ Measurements Using the Constant Head Injection Test04.08
D463195(2008)Test Method for Determining Transmissivity and Storativity of Low Permeability Rocks by In Situ Measurements Using Pressure Pulse Technique04.08
D5084 ★03Test Methods for Measurement of Hydraulic Conductivity of Saturated Porous Materials Using a Flexible Wall Permeameter04.08
D529803Test Method for Measurement of Soil Potential (Suction) Using Filter Paper04.08
D652700(2008)Test Method for Determining Unsaturated and Saturated Hydraulic Conductivity in Porous Media by Steady-State Centrifugation04.09
D683602(2008)ε2Test Methods for Determination of the Soil Water Characteristic Curve for Desorption Using Hanging Column, Pressure Extractor, Chilled Mirror Hygrometer, or Centrifuge04.09
D710006Test Method for Hydraulic Conductivity Compatibility Testing of Soils with Aqueous Solutions04.09
D724306aGuide for Measuring the Saturated Hydraulic Conductivity of Paper Industry Sludges04.09
Exploration, sampling and in situ testing (47)
D420 ★98(2003)Guide to Site Characterization for Engineering Design and Construction Purposes04.08
D421 ★85(2007)Practice for Dry Preparation of Soil Samples for Particle-Size Analysis and Determination of Soil Constants04.08
D145209Practice for Soil Exploration and Sampling by Auger Borings04.08
D155899(2004)ε1Test Method for Moisture Content Penetration Resistance Relationships of Fine-Grained Soils04.08
D1586 ★08aTest Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils04.08
D1587 ★08Practice for Thin-Walled Tube Sampling of Soils for Geotechnical Purposes04.08
D199791(2008)ε1Test Method for Laboratory Determination of the Fiber Content of Peat Samples by Dry Mass04.08
D2573 ★08Test Method for Field Vane Shear Test in Cohesive Soil04.08
D294471(2008)Test Method of Sampling Processed Peat Materials04.08
D3441 ★05Test Method for Mechanical Cone Penetration Tests of Soil04.08
D355001(2007)Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils04.08
D4220 ★95(2007)Practices for Preserving and Transporting Soil Samples04.08
D442707Classification of Peat Samples by Laboratory Testing04.08
D445206Practice for X-Ray Radiography of Soil Samples04.08
D4633 ★10Test Method for Energy Measurement for Dynamic Penetrometers04.08
D464805Test Method for Laboratory Miniature Vane Shear Test for Saturated Fine-Grained Clayey Soil04.08
D4719 ★07Test Methods for Prebored Pressuremeter Testing in Soils04.08
D552094(2006)ε1Test Method for Laboratory Determination of Creep Properties of Frozen Soil Samples by Uniaxial Compression04.08
D571495(2002)Specification for Content of Digital Geospatial Metadata04.08
D5778 ★07Test Method for Electronic Friction Cone and Piezocone Penetration Testing of Soils04.08
D578195(2006)Guide for Use of Dual-Wall Reverse-Circulation Drilling for Geoenvironmental Exploration and the Installation of Subsurface Water-Quality Monitoring Devices04.08
D578295(2006)Guide for Use of Direct Air-Rotary Drilling for Geoenvironmental Exploration and the Installation of Subsurface Water-Quality Monitoring Devices04.08
D578395(2006)Guide for Use of Direct Rotary Drilling with Water-Based Drilling Fluid for Geoenvironmental Exploration and the Installation of Subsurface Water-Quality Monitoring Devices04.08
D578495(2006)Guide for Use of Hollow-Stem Augers for Geoenvironmental Exploration and the Installation of Subsurface Water-Quality Monitoring Devices04.08
D587295(2006)Guide for Use of Casing Advancement Drilling Methods for Geoenvironmental Exploration and Installation of Subsurface Water- Quality Monitoring Devices04.08
D587595(2006)Guide for Use of Cable-Tool Drilling and Sampling Methods for Geoenvironmental Exploration and Installation of Subsurface Water-Quality Monitoring Devices04.08
D587695(2005)Guide for Use of Direct Rotary Wireline Casing Advancement Drilling Methods for Geoenvironmental Exploration and Installation of Subsurface Water-Quality Monitoring Devices04.08
D587995(2003)Practice for Surface Site Characterization for On-Site Septic Systems04.09
D591196(2002)ε1Practice for Minimum Set of Data Elements to Identify a Soil Sampling Site04.09
D592196(2003)ε1Practice for Subsurface Site Characterization of Test Pits for On-Site Septic Systems04.09
D597107Practice for Sampling Freshly Mixed Controlled Low-Strength Material04.09
D606696(2004)Practice for Determining the Normalized Penetration Resistance of Sands for Evaluation of Liquefaction Potential04.09
D615108Practice for Using Hollow-Stem Augers for Geotechnical Exploration and Soil Sampling04.09
D6230 ★98(2005)Test Method for Monitoring Ground Movement Using Probe-Type Inclinometers04.09
D623698(2004)Guide for Coring and Logging Cement - or Lime-Stabilized Soil04.09
D639106Test Method for Field Measurement of Hydraulic Conductivity Limits of Porous Materials Using Two Stages of Infiltration from a Borehole04.09
D651908Practice for Sampling of Soil Using the Hydraulically Operated Stationary Piston Sampler04.09
D6598 ★07Guide for Installing and Operating Settlement Platforms for Monitoring Vertical Deformations04.09
D6635 ★01(2007)Test Method for Performing the Flat Plate Dilatometer04.09
D691404ε1Practice for Sonic Drilling for Site Characterization and the Installation of Subsurface Monitoring Devices04.09
D701507Practices for Obtaining Intact Block (Cubical and Cylindrical) Samples of Soils04.09
D729906Practice for Verifying Performance of a Vertical Inclinometer Probe04.09
D738008Test Method for Soil Compaction Determination at Shallow Depths Using 5-lb (2.3 kg) Dynamic Cone Penetrometer04.09
D738409Practice for Minimum Geospatial Data for a Surface Coal Mining Permit Boundary04.09
D744309Practice for Minimum Geospatial Data for Underground Coal Mining Extents04.09
D7533/D7533M09Practice for Minimum Geospatial Data for Abandoned Mine Land Problem Area04.09
D7534/D7534M09Practice for Minimum Geospatial Data for Abandoned Mine Land Planning Unit04.09
Geophysical methods (16)
D4428/D4428M ★07Test Methods for Crosshole Seismic Testing04.08
D575305Guide for Planning and Conducting Borehole Geophysical Logging04.08
D5777 ★00(2006)Guide for Using the Seismic Refraction Method for Subsurface Investigation04.08
D616797(2004)Guide for Conducting Borehole Geophysical Logging: Mechanical Caliper04.09
D627498(2004)Guide for Conducting Borehole Geophysical Logging - Gamma04.09
D642999(2006)Guide for Selecting Surface Geophysical Methods04.09
D643099(2005)Guide for Using the Gravity Method for Subsurface Investigation04.09
D643199(2005)Guide for Using the Direct Current Resistivity Method for Subsurface Investigation04.09
D643299(2005)Guide for Using the Surface Ground Penetrating Radar Method for Subsurface Investigation04.09
D663901(2008)Guide for Using the Frequency Domain Electromagnetic Method for Subsurface Investigations04.09
D672601(2007)Guide for Conducting Borehole Geophysical Logging— Electromagnetic Induction04.09
D672701(2007)Guide for Conducting Borehole Geophysical Logging— Neutron04.09
D682020Guide for Use of the Time Domain Electromagnetic Method for Subsurface Investigation04.09
D704604Guide for Use of the Metal Detection Method for Subsurface Investigation04.09
D712805Guide for Using the Seismic-Reflection Method for Shallow Subsurface Investigation04.09
D740008Test Methods for Downhole Seismic Testing04.09
Rock (56)
D65309Terminology Relating to Soil, Rock, and Contained Fluids04.08
D163500(2006)Test Method for Flexural Strength of Soil-Cement Using Simple Beam with Third-Point Loading04.08
D2113 ★08Practice for Rock Core Drilling and Sampling of Rock for Site Investigation04.08
D2216 ★05Test Methods for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass04.08
D284508Test Method for Laboratory Determination of Pulse Velocities and Ultrasonic Elastic Constants of Rock04.08
D293608Test Method for Direct Tensile Strength of Intact Rock Core Specimens04.08
D374008Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in Engineering Design and Construction04.08
D396708Test Method for Splitting Tensile Strength of Intact Rock Core Specimens04.08
D439408Test Method for Determining In Situ Modulus of Deformation of Rock Mass Using Rigid Plate Loading Method04.08
D439508Test Method for Determining In Situ Modulus of Deformation of Rock Mass Using Flexible Plate Loading Method04.08
D440384(2005)Practice for Extensometers Used in Rock04.08
D440484(2004)Test Method for Determination of Pore Volume and Pore Volume Distribution of Soil and Rock by Mercury Intrusion Porosimetry04.08
D443608Test Method for Rock Bolt Long-Term Load Retention Test04.08
D450608Test Method for Determining In Situ Modulus of Deformation of Rock Mass Using Radial Jacking Test04.08
D453508Test Methods for Measurement of Thermal Expansion of Rock Using Dilatometer04.08
D454308Practices for Preparing Rock Core as Cylindrical Test Specimens and Verifying Conformance to Dimensional and Shape Tolerances04.08
D455308Test Method for Determining In Situ Creep Characteristics of Rock04.08
D455402(2006)Test Method for In Situ Determination of Direct Shear Strength of Rock Discontinuities04.08
D455501(2005)Test Method for Determining Deformability and Strength of Weak Rock by an In Situ Uniaxial Compressive Test04.08
D461108Test Method for Specific Heat of Rock and Soil04.08
D462308Test Method for Determination of In Situ Stress in Rock Mass by Overcoring Method—USBM Borehole Deformation Gauge04.08
D464408Test Method for Slake Durability of Shales and Similar Weak Rocks04.08
D464508Test Method for Determination of In-Situ Stress in Rock Using Hydraulic Fracturing Method04.08
D475307Guide for Evaluating, Selecting, and Specifying Balances and Standard Masses for Use in Soil, Rock, and Construction Materials Testing04.08
D487908Guide for Geotechnical Mapping of Large Underground Openings in Rock04.08
D491408Test Methods for Density and Unit Weight of Soil and Rock in Place by the Sand Replacement Method in a Test Pit04.08
D497108Test Method for Determining In Situ Modulus of Deformation of Rock Using Diametrically Loaded 76-mm (3-in.) Borehole Jack04.08
D499207Practice for Evaluation of Rock to be Used for Erosion Control04.08
D503004Test Method for Density of Soil and Rock in Place by the Water Replacement Method in a Test Pit04.08
D507908Practices for Preserving and Transporting Rock Core Samples04.08
D512106Practice for Preparation of Rock Slabs for Durability Testing04.08
D519508Test Method for Density of Soil and Rock In-Place at Depths Below Surface by Nuclear Methods04.08
D522008Test Method for Water Mass per Unit Volume of Soil and Rock In-Place by the Neutron Depth Probe Method04.08
D524004Test Method for Testing Rock Slabs to Evaluate Soundness of Riprap by Use of Sodium Sulfate or Magnesium Sulfate04.08
D525501(2008)Practice for Certification of Personnel Engaged in the Testing of Soil and Rock04.08
D531204Test Method for Evaluation of Durability of Rock for Erosion Control Under Freezing and Thawing Conditions04.08
D531304Test Method for Evaluation of Durability of Rock for Erosion Control Under Wetting and Drying Conditions04.08
D533408Test Method for Determination of Thermal Conductivity of Soil and Soft Rock by Thermal Needle Probe Procedure04.08
D533508Test Method for Linear Coefficient of Thermal Expansion of Rock Using Bonded Electric Resistance Strain Gauges04.08
D543409Guide for Field Logging of Subsurface Explorations of Soil and Rock04.08
D560708Test Method for Performing Laboratory Direct Shear Strength Tests of Rock Specimens Under Constant Normal Force04.08
D573004Guide for Site Characterization for Environmental Purposes With Emphasis on Soil, Rock, the Vadose Zone and Ground Water04.08
D5731 ★08Test Method for Determination of the Point Load Strength Index of Rock and Application to Rock Strength Classifications04.08
D577908Test Method for Field Determination of Apparent Specific Gravity of Rock and Manmade Materials for Erosion Control04.08
D587305Test Method for Determination of Rock Hardness by Rebound Hammer Method04.08
D587808Guide for Using Rock-Mass Classification Systems for Engineering Purposes04.09
D588396(2008)Guide for Use of Rotary Kiln Produced Expanded Shale, Clay or Slate (ESCS) as a Mineral Amendment in Topsoil Used for Landscaping and Related Purposes04.09
D603196(2004)Test Method for Logging In Situ Moisture Content and Density of Soil and Rock by the Nuclear Method in Horizontal, Slanted, and Vertical Access Tubes04.09
D6032 ★08Test Method for Determining Rock Quality Designation (RQD) of Rock Core04.09
D616897(2004)Guide for Selection of Minimum Set of Data Elements Required to Identify Locations Chosen for Field Collection of Information to Describe Soil, Rock, and Their Contained Fluids04.09
D616998(2005)Guide for Selection of Soil and Rock Sampling Devices Used With Drill Rigs for Environmental Investigations04.09
D647399(2005)Test Method For Specific Gravity And Absorption of Rock For Erosion Control04.09
D671101(2008)Practice for Specifying Rock to Fill Gabions, Revet Mattresses, and Gabion Mattresses04.09
D707008Test Methods for Creep of Rock Core Under Constant Stress and Temperature04.09
D709904Terminology Relating to Frozen Soil and Rock04.09
D745808Test Method for Determination of Beryllium in Soil, Rock, Sediment, and Fly Ash Using Ammonium Bifluoride Extraction and Fluorescence Detection04.09
Deep foundations and anchors (10)
D1143/D1143M ★07ε1Test Methods for Deep Foundations Under Static Axial Compressive Load04.08
D3689 ★07Test Methods for Deep Foundations Under Static Axial Tensile Load04.08
D396607Test Methods for Deep Foundations Under Lateral Load04.08
D443508Test Method for Rock Bolt Anchor Pull Test04.08
D4945 ★08Test Method for High-Strain Dynamic Testing of Deep Foundations04.08
D578095(2002)Test Methods for Individual Piles in Permafrost Under Static Axial Compressive Load04.08
D5882 ★07Test Method for Low Strain Impact Integrity Testing of Deep Foundations04.09
D676008Test Method for Integrity Testing of Concrete Deep Foundations by Ultrasonic Crosshole Testing04.09
D738308Test Methods for Axial Compressive Force Pulse (Rapid) Testing of Deep Foundations04.09
D740108Test Methods for Laboratory Determination of Rock Anchor Capacities by Pull and Drop Tests04.09
Stabilization, soil-cement and CLSM (14)
D80600(2006)Test Method for Cement Content of Hardened Soil-Cement Mixtures04.08
D163207Practice for Making and Curing Soil-Cement Compression and Flexure Test Specimens in the Laboratory04.08
D315598(2006)Test Method for Lime Content of Uncured Soil-Lime Mixtures04.08
D355108Practice for Laboratory Preparation of Soil-Lime Mixtures Using Mechanical Mixer04.08
D401608Test Method for Viscosity of Chemical Grouts by Brookfield Viscometer (Laboratory Method)04.08
D422399(2006)Practice for Preparation of Test Specimens of Asphalt- Stabilized Soils04.08
D4320/D4320M09Practice for Laboratory Preparation of Chemically Grouted Soil Specimens for Obtaining Engineering Parameters04.08
D438106Test Method for Sand Content by Volume of Bentonitic Slurries04.08
D460908Guide for Evaluating Effectiveness of Admixtures for Soil Stabilization04.08
D483202Test Method for Preparation and Testing of Controlled Low Strength Material (CLSM) Test Cylinders04.08
D598207Test Method for Determining Cement Content of Fresh Soil-Cement (Heat of Neutralization Method)04.09
D602407Test Method for Ball Drop on Controlled Low Strength Material (CLSM) to Determine Suitability for Load Application04.09
D610304Test Method for Flow Consistency of Controlled Low Strength Material (CLSM)04.09
D6910/D6910M09Test Method for Marsh Funnel Viscosity of Clay Construction Slurries04.09
Erosion control, riprap and revetments (23)
D526807Specification for Topsoil Used for Landscaping Purposes04.08
D553994(2008)Specification for Seed Starter Mix04.08
D6092 ★97(2008)Practice for Specifying Standard Sizes of Stone for Erosion Control04.09
D644999(2008)Test Method for Flow of Fine Aggregate Concrete for Fabric Formed Concrete (Flow Cone Method)04.09
D645907Test Method for Determination of Rolled Erosion Control Product (RECP) Performance in Protecting Hillslopes from Rainfall-Induced Erosion04.09
D646007Test Method for Determination of Rolled Erosion Control Product (RECP) Performance in Protecting Earthen Channels from Stormwater- Induced Erosion04.09
D646199(2007)ε2Specification for Silt Fence Materials04.09
D646203(2008)Practice for Silt Fence Installation04.09
D647506Test Method for Measuring Mass Per Unit Area of Erosion Control Blankets04.09
D659900(2008)Practice for Construction of Live Fascines on Slopes04.09
D662901(2007)Guide for Selection of Methods for Estimating Soil Loss by Erosion04.09
D668404Specification for Materials and Manufacture of Articulating Concrete Block (ACB) Revetment Systems04.09
D668501(2008)Guide for the Selection of Test Methods for Fabrics Used for Fabric Formed Concrete (FFC)04.09
D676502(2008)Practice for Live Staking04.09
D6825 ★02(2008)ε1Guide for Placement of Riprap Revetments04.09
D688403Practice for Installation of Articulating Concrete Block (ACB) Revetment Systems04.09
D693903Practice for Brushmattressing04.09
D701404Practice for Assembly and Placement of Double-Twisted Wire Mesh Gabions and Revet Mattresses04.09
D704704Test Method for Mucilloid Content of Plantago Insularis (Ovata, Psyllium) Used as a Tackifiers04.09
D710108Index Test Method for Determination of Unvegetated Rolled Erosion Control Product (RECP) Ability to Protect Soil from Rain Splash and Associated Runoff Under Bench-Scale Conditions04.09
D720806Test Method for Determination of Temporary Ditch Check Performance in Protecting Earthen Channels from Stormwater-Induced Erosion04.09
D727608Guide for Analysis and Interpretation of Test Data for Articulating Concrete Block (ACB) Revetment Systems in Open Channel Flow04.09
D727708Test Method for Performance Testing of Articulating Concrete Block (ACB) Revetment Systems for Hydraulic Stability in Open Channel Flow04.09
Chemical and corrosion (2)
D141109Test Methods for Water-Soluble Chlorides Present as Admixtures in Graded Aggregate Road Mixes04.08
D437302(2007)Test Method for Rapid Determination of Carbonate Content of Soils04.08
Groundwater, wells and environmental (95)
D338509Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer04.08
D340491(2004)Guide for Measuring Matric Potential in Vadose Zone Using Tensiometers04.08
D404396(2004)Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques04.08
D404496(2008)Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers04.08
D405096(2008)Test Method for (Field Procedure) for Withdrawal and Injection Well Tests for Determining Hydraulic Properties of Aquifer Systems04.08
D410496(2004)Test Method (Analytical Procedure) for Determining Transmissivity of Nonleaky Confined Aquifers by Overdamped Well Response to Instantaneous Change in Head (Slug Tests)04.08
D410596(2008)Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Modified Theis Nonequilibrium Method04.08
D410696(2008)Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Theis Nonequilibrium Method04.08
D4542 ★07Test Method for Pore Water Extraction and Determination of the Soluble Salt Content of Soils by Refractometer04.08
D469692(2008)Guide for Pore-Liquid Sampling from the Vadose Zone04.08
D470091(2006)Guide for Soil Sampling from the Vadose Zone04.08
D475087(2001)Test Method for Determining Subsurface Liquid Levels in a Borehole or Monitoring Well (Observation Well)04.08
D508802(2008)Practice for Decontamination of Field Equipment Used at Waste Sites04.08
D509204ε1Practice for Design and Installation of Ground Water Monitoring Wells04.08
D509302(2008)Test Method for Field Measurement of Infiltration Rate Using Double-Ring Infiltrometer with Sealed-Inner Ring04.08
D512690(2004)Guide for Comparison of Field Methods for Determining Hydraulic Conductivity in Vadose Zone04.08
D514306Test Method for Analysis of Nitroaromatic and Nitramine Explosive in Soil by High Performance Liquid Chromatography04.08
D525492(2004)Practice for Minimum Set of Data Elements to Identify a Ground-Water Site04.08
D526996(2008)Test Method for Determining Transmissivity of Nonleaky Confined Aquifers by the Theis Recovery Method04.08
D527096(2008)Test Method for Determining Transmissivity and Storage Coefficient of Bounded, Nonleaky, Confined Aquifers04.08
D529999(2005)Guide for Decommissioning of Ground Water Wells, Vadose Zone Monitoring Devices, Boreholes, and Other Devices for Environmental Activities04.08
D531492(2006)Guide for Soil Gas Monitoring in the Vadose Zone04.08
D540893(2004)Guide for Set of Data Elements to Describe a Ground-Water Site; Part One—Additional Identification Descriptors04.08
D540993(2004)Guide for Set of Data Elements to Describe a Ground-Water Site; Part Two—Physical Descriptors04.08
D541093(2007)Guide for Set of Data Elements to Describe a Ground-Water Site;Part Three—Usage Descriptors04.08
D543503(2008)Test Method for Diagnostic Soil Test for Plant Growth and Food Chain Protection04.08
D544704Guide for Application of a Ground-Water Flow Model to a Site-Specific Problem04.08
D547293(2005)Test Method for Determining Specific Capacity and Estimating Transmissivity at the Control Well04.08
D547393(2006)Test Method for (Analytical Procedure for) Analyzing the Effects of Partial Penetration of Control Well and Determining the Horizontal and Vertical Hydraulic Conductivity in a Nonleaky Confined Aquifer04.08
D547493(2006)Guide for Selection of Data Elements for Ground-Water Investigations04.08
D549093(2008)Guide for Comparing Ground-Water Flow Model Simulations to Site-Specific Information04.08
D552105Guide for Development of Ground-Water Monitoring Wells in Granular Aquifers04.08
D560801(2006)Practices for Decontamination of Field Equipment Used at Low Level Radioactive Waste Sites04.08
D560994(2008)Guide for Defining Boundary Conditions in Ground-Water Flow Modeling04.08
D561094(2008)Guide for Defining Initial Conditions in Ground-Water Flow Modeling04.08
D561194(2008)Guide for Conducting a Sensitivity Analysis for a Ground- Water Flow Model Application04.08
D571695(2006)Test Method for Measuring the Rate of Well Discharge by Circular Orifice Weir04.08
D571895(2006)Guide for Documenting a Ground-Water Flow Model Application04.08
D571995(2006)Guide for Simulation of Subsurface Airflow Using Ground-Water Flow Modeling Codes04.08
D573795(2006)Guide for Methods for Measuring Well Discharge04.08
D573895(2006)Guide for Displaying the Results of Chemical Analyses of Ground Water for Major Ions and Trace Elements—Diagrams for Single Analyses04.08
D575495(2006)Guide for Displaying the Results of Chemical Analyses of Ground Water for Major Ions and Trace Elements—Trilinear Diagrams for Two or More Analyses04.08
D578595(2006)Test Method for (Analytical Procedure) for Determining Transmissivity of Confined Nonleaky Aquifers by Underdamped Well Response to Instantaneous Change in Head (Slug Test)04.08
D578695(2006)Practice for (Field Procedure) for Constant Drawdown Tests in Flowing Wells for Determining Hydraulic Properties of Aquifer Systems04.08
D578795(2009)Practice for Monitoring Well Protection04.08
D585095(2006)Test Method for (Analytical Procedure) Determining Transmissivity, Storage Coefficient, and Anisotropy Ratio from a Network of Partially Penetrating Wells04.08
D585595(2006)Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Confined Nonleaky or Leaky Aquifer by Constant Drawdown Method in Flowing Well04.08
D587795(2005)Guide for Displaying Results of Chemical Analyses of Ground Water for Major Ions and Trace Elements—Diagrams Based on Data Analytical Calculations04.09
D588195(2005)Test Method for (Analytical Procedure) Determining Transmissivity of Confined Nonleaky Aquifers by Critically Damped Well Response to Instantaneous Change in Head (Slug)04.09
D590396(2006)Guide for Planning and Preparing for a Groundwater Sampling Event04.09
D591296(2004)Test Method for (Analytical Procedure) Determining Hydraulic Conductivity of an Unconfined Aquifer by Overdamped Well Response to Instantaneous Change in Head (Slug)04.09
D592096(2005)Test Method (Analytical Procedure) for Tests of Anisotropic Unconfined Aquifers by Neuman Method04.09
D592296(2004)Guide for Analysis of Spatial Variation in Geostatistical Site Investigations04.09
D592396(2004)Guide for Selection of Kriging Methods in Geostatistical Site Investigations04.09
D597896(2005)Guide for Maintenance and Rehabilitation of Ground-Water Monitoring Wells04.09
D597996(2008)Guide for Conceptualization and Characterization of Ground-Water Systems04.09
D598096(2004)Guide for Selection and Documentation of Existing Wells for Use in Environmental Site Characterization and Monitoring04.09
D598196(2008)Guide for Calibrating a Ground-Water Flow Model Application04.09
D599598(2004)Guide for Environmental Site Characterization in Cold Regions04.09
D600096(2008)Guide for Presentation of Water-Level Information from Ground-Water Sites04.09
D600105Guide for Direct-Push Ground Water Sampling for Environmental Site Characterization04.09
D602596(2008)Guide for Developing and Evaluating Ground-Water Modeling Codes04.09
D602896(2004)Test Method (Analytical Procedure) for Determining Hydraulic Properties of a Confined Aquifer Taking into Consideration Storage of Water in Leaky Confining Beds by Modified Hantush Method04.09
D602996(2004)Test Method (Analytical Procedure) for Determining Hydraulic Properties of a Confined Aquifer and a Leaky Confining Bed with Negligible Storage by the Hantush-Jacob Method04.09
D603096(2008)Guide for Selection of Methods for Assessing Ground Water or Aquifer Sensitivity and Vulnerability04.09
D603396(2008)Guide for Describing the Functionality of a Ground-Water Modeling Code04.09
D603496(2004)Test Method (Analytical Procedure) for Determining the Efficiency of a Production Well in a Confined Aquifer from a Constant Rate Pumping Test04.09
D603696(2008)Guide for Displaying the Results of Chemical Analyses of Ground Water for Major Ions and Trace Elements—Use of Maps04.09
D606796(2003)Guide for Using the Electronic Cone Penetrometer for Environmental Site Characterization04.09
D608997(2003)Guide for Documenting a Ground-Water Sampling Event04.09
D610697(2004)Guide for Establishing Nomenclature of Ground-Water Aquifers04.09
D617097(2004)Guide for Selecting a Ground-Water Modeling Code04.09
D617197(2004)Guide for Documenting a Ground-Water Modeling Code04.09
D618797(2003)Practice for Cone Penetrometer Technology Characterization of Petroleum Contaminated Sites with Nitrogen Laser-Induced Fluorescence04.09
D623504Practice for Expedited Site Characterization of Vadose Zone and Ground Water Contamination at Hazardous Waste Contaminated Sites04.09
D628298(2005)Guide for Direct Push Soil Sampling for Environmental Site Characterizations04.09
D628599(2005)Guide for Locating Abandoned Wells04.09
D628698(2006)Guide for Selection of Drilling Methods for Environmental Site Characterization04.09
D631298(2005)Guide for Developing Appropriate Statistical Approaches for Ground-Water Detection Monitoring Programs04.09
D645299(2005)Guide for Purging Methods for Wells Used for Ground-Water Quality Investigations04.09
D651700(2005)Guide for Field Preservation of Ground-Water Samples04.09
D656400(2005)Guide for Field Filtration of Ground-Water Samples04.09
D663401(2006)Guide for the Selection of Purging and Sampling Devices for Ground-Water Monitoring Wells04.09
D664201(2006)Guide for Comparison of Techniques to Quantify the Soil-Water (Moisture) Flux04.09
D672404Guide for Installation of Direct Push Ground Water Monitoring Wells04.09
D672504Practice for Direct Push Installation of Prepacked Screen Monitoring Wells in Unconsolidated Aquifers04.09
D677102Practice for Low-Flow Purging and Sampling for Wells and Devices Used for Ground-Water Quality Investigations04.09
D691103Guide for Packaging and Shipping Environmental Samples for Laboratory Analysis04.09
D704504Guide for Optimization of Ground Water Monitoring Constituents for Detection Monitoring Programs for RCRA Waste Disposal Facilities04.09
D704804Guide for Applying Statistical Methods for Assessment and Corrective Action Environmental Monitoring Programs04.09
D706904Guide for Field Quality Assurance in a Ground-water Sampling Event04.09
D724206Practice for Field Pneumatic Slug (Instantaneous Change in Head) Tests to Determine Hydraulic Properties of Aquifers with Direct Push Ground Water Samplers04.09
D726207Test Method for Estimating the Permanganate Natural Oxidant Demand of Soil and Aquifer Solids04.09
D732207Test Method for Determination of Rolled Erosion Control Product (RECP) Ability to Encourage Seed Germination and Plant Growth Under Bench-Scale Conditions04.09
D735207Practice for Direct Push Technology for Volatile Contaminant Logging with the Membrane Interface Probe (MIP)04.09
Specifications and aggregates (5)
D124107Specification for Materials for Soil-Aggregate Subbase, Base, and Surface Courses04.08
D639308Test Method for Bulk Solids Characterization by Carr Indices04.09
D694004Practice for Measuring Sifting Segregation Tendencies of Bulk Solids04.09
D694105ε1Practice for Measuring Fluidization Segregation Tendencies of Powders04.09
D748109Test Methods for Determining Loose and Tapped Bulk Densities of Powders using a Graduated Cylinder04.09
Other (6)
D321308Practices for Handling, Storing, and Preparing Soft Intact Marine Soil04.08
D461208Practice for Calculating Thermal Diffusivity of Rocks04.08
D588095(2006)Guide for Subsurface Flow and Transport Modeling04.09
D592496(2004)Guide for Selection of Simulation Approaches in Geostatistical Site Investigations04.09
D735107Test Method for Determination of Sediment Retention Device Effectiveness in Sheet Flow Applications04.09
D736707Test Method for Determining Water Holding Capacity of Fiber Mulches for Hydraulic Planting04.09

Source

ASTM International, Annual Book of ASTM Standards 2010, Volume 00.01, Subject Index and Alphanumeric List. Designations and titles are listed for reference; the standards themselves must be obtained from ASTM.

5.2.23 Specific Gravity of Soil Solids

The specific gravity of the solids, Gs, ties together every weight-volume calculation (Section 5.2.21), the hydrometer analysis and the zero-air-voids curve. Most mineral soils fall between 2.65 and 2.75; a lower value warns of organic matter, cinders or other light particles, which are common in old railroad fills. The pycnometer test is simple, but entrapped air and temperature differences are its main sources of error.

5.2.23.1 Method

Equation 5.2-6. Specific gravity by pycnometer

Gs(T) = Ws / [(W1 + Ws) − W2];   Gs(20°C) = A·Gs(T),   A = ρw(T)/ρw(20°C)

W1 = flask filled with water to the mark at T; W2 = flask with soil and water filled to the mark; Ws = oven-dry soil. A ranges from 1.0007 at 16°C to 0.9974 at 30°C. ASTM D854.

5.2.23.2 Worked example

Example 5.2-5: Specific Gravity of a Sandy Silt

Three pycnometer trials on a light brown sandy silt were run at 23°C (Das, Table 3-3). The scanned table prints W2 for the first flask as 722.0 g; the water mass of 37.0 g printed in the same column requires 728.0 g, which is used here.

mark (500 ml)soil WsW2 = flask+ soil + waterT = 23 °CGivenW1 = 666.0, 674.0, 652.0 gW2 = 728.0, 738.3, 709.93 gWs = 99.0, 103.0, 92.0 gTest temperature 23 °CRequiredGs at 20 °C (average)
Pycnometer test: the flask is weighed full of water (W1), then with the soil and water (W2), both filled to the mark at the test temperature.

Given

VariableValueDescription
W1666.0, 674.0, 652.0 gFlask + water to the mark
W2728.0, 738.3, 709.93 gFlask + soil + water
Ws99.0, 103.0, 92.0 gOven-dry soil
T23°CA = 0.9993

Required

  • Gs of each trial at 20°C
  • Average and spread

Equations

  1. Eq. 5.2-6: Ww = W1 + Ws − W2; Gs = Ws/Ww
  2. Eq. 5.2-6: Gs(20°C) = A·Gs(T)

Steps

Step 1 · Water displaced
666.0 + 99.0 − 728.0; 674.0 + 103.0 − 738.3; 652.0 + 92.0 − 709.93
37.0; 38.7; 34.07 g
↓
Step 2 · Gs at 23°C
99.0/37.0; 103.0/38.7; 92.0/34.07
2.676; 2.661; 2.700
↓
Step 3 · Correct to 20°C
× 0.9993
2.674; 2.660; 2.698
Spot check: The trials span 0.038, or 1.4% of the mean, within the 2 to 3% the manual allows.
↓
Step 4 · Average
(2.674 + 2.660 + 2.698)/3
Gs = 2.68
↓
Solution
Gs = 2.68 at 20°C.

Solution

The specific gravity of the solids is 2.68, typical of quartz-rich silt and sand.

Use the measured value rather than an assumed 2.65 or 2.70 in the phase relationships and the hydrometer analysis; a 0.05 error in Gs shifts a computed void ratio by about 3%.

Open the specific gravity calculator →
Pycnometer reduction for any number of trials, the temperature correction to 20 °C, the average and the spread check.

5.2.23.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

5.2.24 Particle-Size Analysis: Sieve and Hydrometer

The gradation curve classifies the soil (USCS, Section 2.2.4.2), checks filter and subballast criteria, and screens frost susceptibility and liquefaction. Sieves cover gravel and sand; the hydrometer test, which measures the density of a soil-water suspension as particles settle, extends the curve into the silt and clay sizes so that the clay fraction and activity can be found.

5.2.24.1 Method

Equation 5.2-7. Sieve analysis

Rn = Wn/W × 100;   percent finer = 100 − ΣRn;   Cu = D60/D10;   Cc = D30²/(D10D60)

Wn = mass retained on sieve n; W = oven-dry specimen mass. Mass lost during sieving should be under 2%.

Equation 5.2-8. Hydrometer analysis (ASTM 152H)

Rcp = R + FT − Fz, FT = −4.85 + 0.25T;   percent finer = aRcp/Ws × 100, a = 1.65Gs/[(Gs − 1)2.65];   L = 16.29 − 0.164(R + Fm) cm;   D = A√(L/t), A = √[30η/((Gs − 1)γw)]

From Stokes’ law. Fz = zero correction; Fm = meniscus correction; T in °C (15 to 28); t in minutes; η = viscosity of water (g·s/cm²); D in mm.

5.2.24.2 Worked example

Example 5.2-6: Gradation of a Sand and of a Silty Clay

A 500-g sample of sand with some fines was sieved (Das, Table 4-2), and a 50-g sample of brown silty clay was tested with the 152H hydrometer at 28°C (Das, Table 5-4; Gs = 2.75, Fz = 7, Fm = 1).

No. 4: 0 gNo. 10: 40.2 gNo. 20: 84.6 gNo. 40: 40.0 gNo. 60: 106.4 gNo. 200: 59.4 gpan: 8.7 gSieve stack (No. 30 and No. 140 not shown)GivenW = 500 g oven-dryMasses retained on 8 sieves + panHydrometer data (Table 5-4 of Das)RequiredPercent finerD10, D30, D60, Cu, CcGravel, sand, fines
Sieve analysis: mass retained on each sieve of the stack; a separate hydrometer test on the fines extends the curve below 0.075 mm.

Given

VariableValueDescription
W500 gSieve specimen
Retained0, 40.2, 84.6, 50.2, 40.0, 106.4, 108.8, 59.4 g; pan 8.7 gNo. 4, 10, 20, 30, 40, 60, 140, 200
HydrometerR = 51 at 0.25 min … 27 at 2,880 minWs = 50 g, T = 28°C

Required

  • Sieve: percent finer, D10, D30, D60, Cu, Cc
  • Hydrometer: percent finer and particle size at each reading

Equations

  1. Eq. 5.2-7: percent finer = 100 − ΣRn
  2. Eq. 5.2-7: Cu, Cc
  3. Eq. 5.2-8: Rcp, a, L, A, D

Steps

Step 1 · Sieve losses
Σ retained = 498.3 g
Loss 0.34% (under 2%)
↓
Step 2 · Percent finer
No. 10: 100 − 8.0; No. 20: 100 − 24.9; No. 40: 57.1; No. 60: 35.8; No. 140: 14.0; No. 200: 2.1
92.0, 75.1, … 2.1%
↓
Step 3 · Characteristic sizes
Log interpolation on the curve
D60 = 0.48 mm; D30 = 0.20 mm; D10 = 0.095 mm
Spot check: Das reads 0.46, 0.21 and 0.098 mm from the plotted curve.
↓
Step 4 · Coefficients
0.484/0.0945; 0.200²/(0.0945 × 0.484)
Cu = 5.1; Cc = 0.87: poorly graded sand
↓
Step 5 · First hydrometer reading
FT = −4.85 + 0.25(28) = 2.15; Rcp = 51 + 2.15 − 7 = 46.15; a = 0.978; L = 16.29 − 0.164(52) = 7.76 cm; A = 0.0121
Percent finer 90.3%; D = 0.0121√(7.76/0.25) = 0.068 mm
Spot check: Matches Das: 90.3% and 0.068 mm. The last reading gives 43.3% finer than 0.0008 mm.
↓
Solution
Sand: D60 0.48, D30 0.20, D10 0.095 mm, Cu 5.1, Cc 0.87 (SP); silty clay: about 54% finer than 0.002 mm.

Solution

The sand is poorly graded (SP) with only 2% fines; the silty clay has about 54% clay-size particles.

For railroad work the sand’s narrow gradation matters for filters and subballast (Section 2.4.19); the clay fraction of the silty clay, with its PI, gives the activity used to screen swell (Section 2.2.15).

Open the particle-size analysis calculator →
Sieve reduction with the loss check, the 152H hydrometer reduction with all corrections, the combined gradation curve, D10, D30, D60, Cu, Cc and the gravel, sand, fines and clay fractions.

5.2.24.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

  • B.M. Das, Soil Mechanics Laboratory Manual, 6th ed. (2002): Chapters 4 and 5, Tables 4-2 and 5-1 to 5-4.Find source ↗
  • ASTM D6913 (sieve analysis) and D7928 (hydrometer analysis; formerly D422, withdrawn 2016; use D6913/D6913M (sieve) and D7928 (hydrometer)).Official page ↗
5.2.25 Atterberg Limits: Data Reduction

The liquid and plastic limits place a fine-grained soil on the plasticity chart, correlate with compressibility and strength, and, with the natural water content, show whether a clay is near its liquid limit (sensitive, likely to flow) or below its plastic limit (stiff or desiccated). The shrinkage limit adds a measure of how much the soil will shrink as it dries, which matters for embankment cracking and track geometry on expansive clay.

5.2.25.1 Method

Equation 5.2-9. Liquid limit

Multipoint: w = a − FI log N, LL = w at N = 25;   One-point: LL = wN(N/25)0.121;   Fall cone: LL = w at 20 mm penetration (80 g, 30° cone)

FI = flow index; N = blows to close the groove 1/2 in. The one-point method applies for N = 20 to 30. The cone method (Nagaraj, 1993) is less operator-dependent and agrees with the cup below LL ≈ 100%.

Equation 5.2-10. Plastic and shrinkage limits and indices

PI = LL − PL;   LI = (wn − PL)/PI;   A = PI/(% < 0.002 mm);   SL = wi − (Vi − Vf)ρw/Wdry × 100

A-line: PI = 0.73(LL − 20). Vi, Vf = volume of the wet and dry pat (mercury mass/13.6, or wax method ASTM D4943).

Table 5.2-16. Reading the indices
IndexRangeMeaning
Liquidity index LI> 1Water content above LL: sensitive, flows when remolded
0 to 1Plastic range
< 0Below PL: stiff, often desiccated or overconsolidated
Activity A< 0.75Inactive (kaolinite)
0.75 to 1.25Normal (illite)
> 1.25Active (smectite): swell likely

5.2.25.2 Worked example

Example 5.2-7: Limits of a Gravelly Silty Clay

Three cup trials, a plastic limit trial and a shrinkage limit pat were run on samples from the Das laboratory manual (Tables 6-1, 7-1 and 8-1).

Casagrande cup: groove closes 1/2 in. after N blows1/8-in. thread (PL)N = 35, 23, 17Given3 LL trials: can masses and N1 PL trialShrinkage pat: Vi 14.62, Vf 11.05 cm³RequiredLL, PL, PIPlasticity chart symbolShrinkage limit
Liquid limit by the flow curve from three cup trials, plastic limit by rolling threads, and shrinkage limit from the volume of a dried pat.

Given

VariableValueDescription
LL trialscans 15.26/29.30/25.84 g at N = 35; 17.01/31.58/27.72 g at N = 23; 15.17/31.45/26.96 g at N = 17can, can + wet, can + dry
PL trial13.33/23.86/22.27 g
SL patdish 12.34 g; + wet 40.43 g; + dry 33.68 g; Vi = 14.62, Vf = 11.05 cm³Mercury 198.83 g and 150.30 g /13.6

Required

  • LL, PL, PI and the plasticity chart symbol
  • Shrinkage limit

Equations

  1. Eq. 5.2-9: w = (W2 − W3)/(W3 − W1) × 100; flow curve at N = 25
  2. Eq. 5.2-10: PI = LL − PL; A-line
  3. Eq. 5.2-10: SL = wi − (Vi − Vf)/Wdry × 100

Steps

Step 1 · Water contents
3.46/10.58; 3.86/10.71; 4.49/11.79
32.70%, 36.04%, 38.08%
↓
Step 2 · Flow curve
Least-squares fit of w on log N
FI = 17.2; LL = 35.3%
Spot check: Das reports LL ≈ 35.2% from the plotted line.
↓
Step 3 · Plastic limit
1.59/8.94
PL = 17.8%
↓
Step 4 · PI and chart
35.3 − 17.8; A-line 0.73(35.3 − 20) = 11.2
PI = 17.5, above the A-line: CL
↓
Step 5 · Shrinkage limit
wi = 6.75/21.34 = 31.63%; Δw = 3.57/21.34 = 16.73%
SL = 14.9%
Spot check: Das: 31.63%, 16.72% and 14.91%.
↓
Solution
LL = 35.3%, PL = 17.8%, PI = 17.5% (CL); SL = 14.9%.

Solution

The fines are a lean clay (CL) with LL 35, PI 17.5 and a shrinkage limit of about 15%.

LL/SL = 2.4, a moderate shrinkage potential: fills of this clay will crack when they dry below about 15% water content, opening paths for rain into the embankment.

Open the Atterberg limits calculator →
Liquid limit by multipoint flow curve, one-point method or fall cone; plastic limit; shrinkage limit and ratio; PI, LI, activity, toughness index and the plasticity chart.

5.2.25.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

  • B.M. Das, Soil Mechanics Laboratory Manual, 6th ed. (2002): Chapters 6 to 8, Tables 6-1, 7-1 and 8-1.Find source ↗
  • T.S. Nagaraj, Principles of Testing Soils, Rocks and Concrete, Elsevier (1993): Chapter 9, cone penetration and one-point liquid limit methods.Find source ↗
  • ASTM D4318, Liquid Limit, Plastic Limit and Plasticity Index of Soils.Official page ↗Library entry
5.2.26 Laboratory Permeability Tests

Laboratory permeability tests give the hydraulic conductivity of a specimen at a known density. Constant-head tests suit clean sands and gravels; falling-head tests suit finer sands and silts; clays need a flexible-wall permeameter (ASTM D5084). Results are corrected to 20°C because the viscosity of water changes about 2% per degree. Field values, which are controlled by layering and fissures, are usually higher; use the lab value to compare materials, design filters and check drainage layers.

5.2.26.1 Method

Equation 5.2-11. Coefficient of permeability

Constant head: k = QL/(Aht);   Falling head: k = 2.303(aL/At) log(h1/h2);   k20 = kTηT/η20

Q = volume collected in time t; h = constant head difference; a = standpipe area; h1, h2 = heads at the start and end; A, L = specimen area and length; ηT/η20 = 0.889 at 25°C, 1.135 at 15°C.

5.2.26.2 Worked example

Example 5.2-8: Constant Head Test on a Uniform Sand

A uniform sand was tested in a 6.35-cm permeameter at three heads (Das, Tables 10-2 and 10-3). The specimen’s dry mass was 726.9 g and Gs = 2.66.

L = 13.2 cmh = 60, 70, 80 cmQ in tD = 6.35 cmGivenD = 6.35 cm, L = 13.2 cmQ = 305, 375, 395 cm³ in 60 sh = 60, 70, 80 cm; T = 25 °CRequiredk at 25 °C and k20
Constant head permeameter: flow Q is collected in time t under a constant head difference h across a specimen of length L.

Given

VariableValueDescription
D, L6.35 cm; 13.2 cmA = 31.67 cm²
Q305, 375, 395 cm³ in 60 s
h60, 70, 80 cm
T25°Cη25/η20 = 0.889
Md726.9 gDry specimen

Required

  • Void ratio
  • k at 25°C and k20

Equations

  1. e = Gsρw/ρd − 1
  2. Eq. 5.2-11: k = QL/(Aht)
  3. Eq. 5.2-11: k20 = kTηT/η20

Steps

Step 1 · Void ratio
ρd = 726.9/418.0 = 1.739 g/cm³; 2.66/1.739 − 1
e = 0.53
↓
Step 2 · Runs
305(13.2)/(31.67 × 60 × 60); 375(13.2)/(31.67 × 70 × 60); 395(13.2)/(31.67 × 80 × 60)
0.0353, 0.0372, 0.0343 cm/s
Spot check: The three runs agree within 8%, so the flow stayed laminar.
↓
Step 3 · Average and correction
0.0356 × 0.889
k20 = 0.032 cm/s = 90 ft/day
Spot check: Das: average 0.035 and k20 = 0.031 cm/s; the falling-head test on the same sand gives 0.033 cm/s.
↓
Solution
k20 = 0.032 cm/s (about 90 ft/day) at e = 0.53.

Solution

The sand’s permeability is about 3 × 10−2 cm/s at 20°C, typical of a clean, uniform medium sand.

This is free-draining for a subballast or drainage blanket; check the filter criteria against the subgrade (Section 2.4.19) so fines do not migrate into it.

Open the laboratory permeability calculator →
Constant- and falling-head reductions for any number of runs, the viscosity correction to 20 °C, the specimen void ratio, k in cm/s and ft/day.

5.2.26.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

5.2.27 Unconfined Compression Test Reduction

The unconfined compression test is the quickest measure of the undrained strength of a clay sample: an unconfined cylinder is loaded axially until it fails or reaches 15 to 20% strain. It is the strength usually reported on boring logs of cohesive soil and used for quick undrained stability checks of embankments and cuts. Because there is no confinement, fissures and sample disturbance lower the result, so it is a lower bound to the in-situ strength.

5.2.27.1 Method

Equation 5.2-12. Stress, strength and modulus

ε = ΔL/L0;   Ac = A0/(1 − ε);   σ = P/Ac;   qu = σmax (or σ at 15–20% strain);   su = qu/2;   E50 = (qu/2)/ε50;   St = qu/qu,remolded

A0 = initial area; the area correction assumes the specimen bulges uniformly. ASTM D2166.

5.2.27.2 Worked example

Example 5.2-9: Unconfined Strength of a Light Brown Clay

A 1.43-in. by 3.0-in. specimen of light brown clay was tested in a frame with a proving ring of 0.264 lb per division (Das, Table 16-1).

P = dial × 0.264 lbL0 = 3.0 in.D = 1.43 in.GivenD = 1.43 in., L0 = 3.0 in.Ring factor 0.264 lb/div17 readings of ΔL and dialRequiredStress-strain curvequ, su = qu/2, E50
Unconfined compression: the specimen is loaded axially with no confining pressure; the cross-section grows as it shortens, so each stress uses the corrected area.

Given

VariableValueDescription
D, L01.43 in.; 3.0 in.A0 = 1.606 in.²
Ring factor0.264 lb/div
ReadingsΔL 0 to 0.36 in.; dial 0 to 86 div17 readings

Required

  • Stress-strain curve and qu
  • su, E50 and consistency

Equations

  1. Eq. 5.2-12: ε = ΔL/L0; Ac = A0/(1 − ε)
  2. Eq. 5.2-12: σ = P/Ac; qu = σmax
  3. Eq. 5.2-12: su = qu/2; E50

Steps

Step 1 · Peak reading
ΔL = 0.18 in.: ε = 0.06; P = 86 × 0.264 = 22.70 lb; Ac = 1.606/0.94 = 1.708 in.²
σ = 13.29 psi
↓
Step 2 · Strength
qu = 13.29 psi; su = 6.64 psi
su = 957 psf: medium stiff
Spot check: Das: qu = 13.288 psi at 6% strain.
↓
Step 3 · Modulus
Half of qu = 6.64 psi reached at ε50 = 0.73%
E50 ≈ 910 psi (131 ksf), E50/su ≈ 140
↓
Solution
qu = 13.3 psi; su ≈ 960 psf; E50 ≈ 910 psi.

Solution

The clay has an unconfined strength of 13.3 psi, so su ≈ 960 psf (medium stiff).

Before using it for a slope or bearing check, compare with pocket penetrometer and vane readings on the same sample; if the clay is fissured or the sample was disturbed, the field strength may be noticeably higher, and a UU triaxial test is the better design value.

Open the unconfined compression calculator →
Strain, area-corrected stress and the stress-strain curve from raw dial readings; qu, su, strain at failure, E50, consistency and sensitivity.

5.2.27.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

5.2.28 Direct Shear Test Reduction

The direct shear box is the common test for the friction angle of sands, ballast fines, subballast and drained clays (at slow rates). The upper half of the box is displaced across the lower half under a fixed normal load while the shear force and the change in height are recorded. Dense sands reach a peak and then soften toward an ultimate value as they dilate; loose sands contract and show no clear peak. Section 5.2.17 (Shear Strength from Lab Tests) fits envelopes to already-reduced results; this section reduces the raw readings.

5.2.28.1 Method

Equation 5.2-13. Direct shear reduction

τ = S/A = (dial × ring factor)/A;   σ = N/A;   Clean sand: tanφ = τpeak/σ;   Several tests: τ = c + σ tanφ (least squares)

A = box area; N = normal load; S = shear force. ASTM D3080: for clays, shear slowly enough for drainage.

5.2.28.2 Worked example

Example 5.2-10: Friction Angle of a Uniform Sand

A 2-in. square specimen of uniform sand at e = 0.596 was sheared under a normal load of 56 lb (Das, Tables 15-1 and 15-2).

N = 56 lbS = dial × 0.31 lbBox 2 in. × 2 in.; shear plane between halvesGivenBox 2 × 2 in.; N = 56 lbRing factor 0.31 lb/div13 readings to 0.12 in.RequiredPeak and ultimate τφ peak and φ ultimate
Direct shear: the upper half of the box is pushed across the lower half under a constant normal load; the proving ring measures the shear force.

Given

VariableValueDescription
Box2 in. × 2 in.A = 4.0 in.²
N56 lbσ = 14 psi
Ring factor0.31 lb/div
ReadingsDial 45 to 129 to 105 div over 0.12 in.Vertical +0.001 to +0.010 in.

Required

  • Peak and ultimate shear stress
  • Peak and ultimate friction angle

Equations

  1. Eq. 5.2-13: τ = dial × 0.31/4.0
  2. Eq. 5.2-13: tanφ = τ/σ — c = 0

Steps

Step 1 · Normal stress
56/4.0
σ = 14.0 psi
↓
Step 2 · Peak
Dial 129 at 0.06 in.: 129 × 0.31/4.0
τpeak = 10.0 psi
↓
Step 3 · Peak angle
atan(10.0/14.0)
φpeak = 35.5°
Spot check: Das plots the same envelope: s = σ tan 35.5°.
↓
Step 4 · Ultimate
Dial 105 at 0.12 in.: 105 × 0.31/4.0 = 8.14 psi; atan(8.14/14.0)
φult ≈ 30°
Spot check: The specimen expanded 0.010 in. before the peak: a dense, dilating sand.
↓
Solution
φpeak = 35.5°; ultimate about 30°.

Solution

The sand has a peak friction angle of 35.5°, softening to about 30° at large displacement.

For slopes and walls where the sand may already have moved (old slides, reworked fill), use the lower, ultimate value. Run at least three normal stresses spanning the field range before relying on the envelope; one test assumes c = 0.

Open the direct shear calculator →
Raw proving-ring readings for any number of tests reduced to stress-displacement curves, peak and ultimate stress and dilation, and the peak and ultimate envelopes.

5.2.28.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

5.2.29 Slake Durability of Shale and Weak Rock

Shales, mudstones and claystones that look sound when cut can break down within months of exposure to wetting and drying. In railroad cuts this produces raveling, undercutting of harder beds and rockfall onto the track; as fill or riprap such rock turns to clay. The slake durability test measures that resistance by tumbling oven-dried lumps in a mesh drum half immersed in water; the second-cycle index, Id2, is the standard reporting value.

5.2.29.1 Method

Equation 5.2-14. Slake durability index

Id1 = (B − D)/(A − D) × 100;   Id2 = (C − D)/(A − D) × 100

A = drum + oven-dry sample before the test; B, C = drum + oven-dry retained material after the first and second 10-minute cycles; D = empty drum. ASTM D4644 (withdrawn 2025); ISRM suggested method.

Table 5.2-17. Slake durability classifications
First cycle Id1 (Franklin and Chandra, 1972)ClassSecond cycle Id2 (Gamble, 1971)Class
0–25%Very low0–30%Very low
25–50%Low30–60%Low
50–75%Medium60–85%Medium
75–90%High85–95%Medium high
90–95%Very high95–98%High
95–100%Extremely high98–100%Very high

Nagaraj (1993, Table 9.7) reprints the first-cycle classes with “high” and “very high” interchanged; the order above follows the original. Morgenstern and Eigenbrod (1974) also classify the amount of slaking by the liquid limit of the slaked material: very low below 20%, low 20 to 50%, medium 50 to 90%, high 90 to 140%, very high above 140%.

5.2.29.2 Worked example

Example 5.2-11: Durability of a Shale in a Rock Cut

Ten lumps of gray shale from a cut on a Class I railroad located in Pennsylvania were tested to decide whether the face needs protection. The masses are illustrative of a typical laboratory result.

Mesh drum half-immersed, 20 rpm for 10 min per cycledrum D = 1,220 gGivenDrum 1,220 g; drum + sample 1,715 gAfter cycle 1: 1,652 gAfter cycle 2: 1,571 g; LL = 38%RequiredId1, Id2Durability class
Slake durability: oven-dry lumps tumble in a mesh drum half-immersed in water; the fraction retained after two wet-dry cycles is Id2.

Given

VariableValueDescription
D1,220.0 gEmpty drum
A1,715.0 gDrum + oven-dry sample
B1,652.0 gAfter cycle 1
C1,571.0 gAfter cycle 2
LL38%Slaked fines

Required

  • Id1 and Id2
  • Durability and slaking classes

Equations

  1. Eq. 5.2-14: Id1 = (B − D)/(A − D) × 100
  2. Eq. 5.2-14: Id2 = (C − D)/(A − D) × 100
  3. Table 5.2-17: Classes

Steps

Step 1 · Sample mass
1,715.0 − 1,220.0
495.0 g
↓
Step 2 · First cycle
(1,652.0 − 1,220.0)/495.0 × 100
Id1 = 87.3%: high
↓
Step 3 · Second cycle
(1,571.0 − 1,220.0)/495.0 × 100
Id2 = 70.9%: medium
Spot check: The second cycle lost 81 g against 63 g in the first: the breakdown is accelerating, as it does in shales that soften with each wetting.
↓
Step 4 · Slaking amount
LL = 38% (20 to 50%)
Low
↓
Solution
Id2 = 70.9%: medium durability (Gamble).

Solution

The shale has medium durability (Id2 = 71%): it will weather noticeably once exposed.

In the cut, expect the shale to ravel back and undercut any harder sandstone beds above it; plan for a catchment ditch sized for that debris (rock fall hazard rating, Section 3.8.29), consider shotcrete or drapery on the shale band, and do not use the excavated shale as riprap or rockfill.

Open the slake durability calculator →
First- and second-cycle slake durability indices with the Franklin and Chandra and Gamble classes, the fragment type and the slaking class by liquid limit.

5.2.29.3 Sources

Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.

  • T.S. Nagaraj, Principles of Testing Soils, Rocks and Concrete, Elsevier (1993): Section 9.5.1 and Tables 9.6 and 9.7.Find source ↗
  • J.A. Franklin and R. Chandra (1972), The slake-durability test, International Journal of Rock Mechanics and Mining Sciences, 9, 325–341.Find source ↗
  • J.C. Gamble (1971), Durability-plasticity classification of shales and other argillaceous rocks, Ph.D. thesis, University of Illinois.Find source ↗
  • N.R. Morgenstern and K.D. Eigenbrod (1974), Classification of argillaceous soils and rocks, Journal of the Geotechnical Engineering Division, ASCE, 100(GT10).Find source ↗
  • ASTM D4644 (withdrawn 2025), Slake Durability of Shales and Other Similar Weak Rocks.Official page ↗
5.2.30 Soil Chemistry Tests: Methods, Sample Handling and Corrosivity

Railroad projects need soil chemistry results mainly to judge corrosion of buried steel and concrete (soldier piles, H-piles, corrugated metal culverts, anchors, soil nails), sulfate attack and sulfate heave in treated soil (Chapter 2.12; Section 7.2.7), and contamination (Chapter 5.4). Chemistry results depend on how the test is run and on what happened to the sample between the hole and the laboratory far more than most geotechnical index tests do (Conklin 2014).

5.2.30.1 Tests and what they measure

Table 5.2-18. Common soil chemistry tests for geotechnical work (after Conklin 2014)
TestHow it is measuredWhat to watch
pHpH meter in a soil–water mix, commonly 1:1 by weight (for example 10 g soil and 10 mL distilled water) after standing about 10 minutesTests in a salt solution (KCl or CaCl2) release exchangeable acidity and read lower (more acidic) than water tests. Corrosivity criteria assume the method in the governing standard, so the report must state the method and ratio. Do not let the laboratory substitute its own procedure.
Redox potential (Eh)Platinum and reference electrodes on a pH meter, reported in mVLow Eh means reducing (oxygen-free) conditions, typical of saturated and organic soil; these favor sulfate-reducing bacteria and microbially influenced corrosion. Eh depends on pH, so report both. Exposure to air changes Eh quickly: measure in the field or on sealed, promptly tested samples.
Electrical conductivity (EC)Conductivity cell on a saturated-paste extract or on a soil–water extract, in dS/mEC rises with dissolved salts. Soils with pH below 8.5 and EC above 4 dS/m are saline; high sodium makes soils sodic, which disperses clay. Extract EC (1 dS/m corresponds to about 1,000 ohm-cm in the extract) is not the same as soil-box resistivity of the saturated soil, so do not interchange them.
Sulfate and chlorideWater extraction, then ion analysisThe extraction ratio and the drying temperature both change the result (see below).
Moisture stateAir-dry soil still holds about 1–2% water, more in organic soilResults reported on an air-dry basis should state the residual water content.

5.2.30.2 Samples change after they leave the ground

  • Chemical species can increase, decrease or change form during sampling and storage. Microorganisms stay active in the sample, even when it is chilled; ammonia oxidizes to nitrate and hydrocarbons degrade.
  • Keep samples in the conditions they came from: saturated, oxygen-free samples should stay sealed and full. Use plastic or glass containers, keep them cool in an insulated cooler, and get them to the laboratory quickly.
  • Typical maximum holding times: pH as soon as possible; nitrate 2 days chilled; hexavalent chromium 1 day; chloride 28 days; sulfate 28 days chilled (EPA SW-846 Chapter 2 gives the full list).
  • Drying changes results. In one comparison of air-dried and oven-dried (200°F) samples, pH changed only slightly, but sulfate differed by 47% and potassium by 16%. Ask the laboratory how samples were dried before analysis.

5.2.30.3 Screening buried steel and concrete

FHWA guidance for buried steel reinforcement and soil nails treats ground as aggressive when any of the following applies: pH below 5 or above 10; resistivity below 3,000 ohm-cm; chloride above 100 ppm; sulfate above 200 ppm; or organic content above 1%. Use the same screen for soldier piles, H-piles, culvert pipe and anchors, and apply the railroad’s own criteria where they are stricter. Sulfate also governs concrete exposure class and the risk of sulfate heave in lime- or cement-treated soil.

For railroad work: Take corrosivity samples from the borings at the depths of buried steel and below the water table, not only from the surface, and specify the test standards (for example, AASHTO T 288, T 289, T 290 and T 291, or ASTM G51 and G187) in the laboratory request. Seal and cool the samples, and ask for pH and redox to be run first. In saturated organic ground, cinders, or old fills beneath yards, measure redox and look for sulfides, because reducing conditions can make steel corrode quickly even when pH and resistivity look acceptable. Report the method, the extraction ratio and the drying temperature with every result so that later tests can be compared.

Source: Conklin (2014), Chapters 5–9; screening limits from FHWA corrosion guidance for MSE walls and soil nails. Full reference under Supplemental References.

Author and Sources

Authors: Daniel P. Colwell and Mario Ruel. This chapter was written and compiled by Daniel P. Colwell and Mario Ruel for Railway Ground Hazard Risk Management.

Technical content is drawn from the published sources below, and credit for that material belongs to their authors and publishers. Tables, equations and figures taken from a specific source are also cited where they appear.

Primary sources

Supplemental references

File locations for these documents are listed under Supplemental References.

Supplemental References

Material in the green “Supplemental reference” boxes throughout this chapter was added from the following documents in the LEVI geotechnical library. Text is summarized or paraphrased; tables are reproduced with their original source noted; figures are reproduced from the cited document for internal reference use. Consult the original document before relying on a value for design. Blocks marked “After Selig & Waters (1994)” summarize item S7 for railroad clients; tables are condensed from the book and its figures are not reproduced. The Case Studies section summarizes case studies from item S8 by Burt G. Look; its figures are reproduced from the book for internal reference use, and the closing “For railroad work” note in each case study is added by the authors of this manual.

  1. U.S. Army Corps of Engineers (1970, with changes through 1986). Calibration of Laboratory Soils Testing Equipment. EM 1110-2-1909Find source ↗Library entry
  2. U.S. Army Corps of Engineers (1970, with changes). Laboratory Soils Testing. EM 1110-2-1906Find source ↗Library entry
  3. Das, B. M. (2002). Soil Mechanics Laboratory Manual, 6th ed. Oxford University PressFind source ↗
  4. Nagaraj, T. S. (1993). Principles of Testing Soils, Rocks and Concrete. Elsevier (Developments in Geotechnical Engineering)Find source ↗
  5. Profillidis, V. A. (2014). Railway Management and Engineering, 4th ed. Farnham, UK: Ashgate. Chapters 7–9, 11–13, 16–17, 20 and 22 (track system, mechanical behavior of track, subgrade, sleepers, ballast, transverse effects, maintenance, slab track, electrification foundations, safety)Find source ↗Library entry
  6. Geotechnology for Railroaders Program, Modules 1–8 (two-day training course reference: risk management, geology and soils, ballast and sub ballast, drainage, slides, slope and subgrade stabilization, scour, rock falls, beaver dams, winter problems, spring thaw, extreme weather, earthquakes). Field photographs and figures from the course; slope stabilization process slides adapted from material by D. ColwellFind source ↗
  7. Selig, E. T. and Waters, J. M. (1994). Track Geotechnology and Substructure Management. London: Thomas Telford. Used on this page: chs. 3, 7, 8, 9 and 10Find source ↗Library entry
  8. Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. Leiden: CRC Press/Balkema (Taylor & Francis). ISBN 978-1-032-10470-6. Case studies used on this page: §5.8, §7.9Find source ↗Library entry
  9. Conklin, A. R., Jr. (2014). Introduction to Soil Chemistry: Analysis and Instrumentation, 2nd ed. Hoboken, NJ: John Wiley & Sons. Used on this page: Section 5.2.30Find source ↗
← Previous · 5.0 Testing Chapter 5.1 — In Situ Testing