5.2.13 Laboratory Testing Checklist

Laboratory testing is the scientific foundation of every geotechnical design.
Authors: Daniel P. Colwell and Mario Ruel
5.2.13 Laboratory Testing Checklist

Checklist · Part V · Subsurface Exploration

Laboratory Testing Checklist

Pre-Field0 of 7
Field0 of 6
Laboratory Phase0 of 6
Report Integration0 of 5
Ticks are saved in this browser.
Plain text version

Pre-Field

  • [ ] Analysis matrix completed (Table 5.2-1 adapted to project type); tests selected match analytical needs
  • [ ] Laboratory subcontract awarded; accreditation scope verified per-method for all required tests
  • [ ] COC forms prepared and printed; field team briefed on COC procedure
  • [ ] Shelby tube size and quantity confirmed (typically 3-in. OD for ASTM D1587, withdrawn 2024)
  • [ ] Shipping coolers, foam padding, and waterproof labels procured
  • [ ] Rush processing option confirmed with laboratory (if project schedule requires)
  • [ ] Sample retention requirements confirmed with client

Field

  • [ ] Water content taken on every sample (no exceptions)
  • [ ] Shelby tubes sealed within 2 hours of extraction; ends waxed
  • [ ] COC form completed for each sample; signed by collector
  • [ ] Samples shipped within 72 hours; COC transmitted to laboratory with shipment
  • [ ] Condition at laboratory receipt confirmed (email or call from lab supervisor)
  • [ ] Test assignments transmitted to laboratory with priority schedule

Laboratory Phase

  • [ ] 10% duplicate testing performed per QC program (Table 5.2-2)
  • [ ] SQD computed for all Shelby tube-based tests; poor quality samples flagged
  • [ ] All raw data retained by laboratory (not just final results)
  • [ ] Laboratory report includes technician and supervisor signatures
  • [ ] Electronic data (CSV or Excel) received and checked against PDF report
  • [ ] Accreditation certificate attached to laboratory report as QC document

Report Integration

  • [ ] Lab data master table complete (all samples; Table 5.2-6 format)
  • [ ] All design parameters sourced from lab data with traceability to sample ID and test date
  • [ ] SQD flags noted in engineering properties discussion (Section 6 of GDR/FGR)
  • [ ] Any test anomalies or out-of-specification results explained in report narrative
  • [ ] Sample retention calendar established; laboratory notified of client retention requirements
← Previous · 5.0 Testing Chapter 5.1 — In Situ Testing