↑ Parent Menu⌂ Main Menu
← Chapter 5.2 Laboratory Testing Program
GHRM
Railway Ground Hazard Risk Management · 5.0 · Testing
Sections · click a car to open it

5.2.9 Worked Calculation Examples

Laboratory testing is the scientific foundation of every geotechnical design.
Authors: Daniel P. Colwell and Mario Ruel
5.2.9 Worked Calculation Examples
The three examples reduce the three laboratory tests that most often control railroad designs: consolidation, compaction with CBR, and CU triaxial. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution.
Example 5.2-1: Consolidation Test Analysis for a Bridge Approach

An oedometer test on a tube sample from 18 to 20 ft under a bridge approach embankment on a Class I railroad located in Georgia. Three numbers come out of the e-log σ′ curve: the preconsolidation stress, the compression index above it and the recompression index below it. Together with the present effective stress they say which settlement equation of Chapter 6.2 applies.

0.111011.21.41.61.8σ′ (tsf, log scale)Void ratio eσ′p = 1.50 tsfCc = ?Cr = ?OCR = ?Givene at 0.125–16 tsf (8 stages)σ′p = 1.50 tsf (Casagrande)γsat = 115 pcf; GWT at surfaceSample depth z = 19 ftRequiredCc and Cr OCRBlack = given; red = required
Given and required for Example 5.2-1.

Given

VariableValueDescription
Dataσ′ = 0.125, 0.25, 0.5, 1, 2, 4, 8, 16 tsf; e = 1.820, 1.795, 1.762, 1.698, 1.590, 1.430, 1.235, 1.015End of each load stage
σ′p1.50 tsfCasagrande construction (maximum curvature near 1.0 to 1.5 tsf)
γsat115 pcfWater table at the surface
z19 ftSample depth

Required

  • Cc and Cr
  • OCR

Equations

  1. Eq. 1: C = Δe / Δlog σ′ — slope of the e-log σ′ curve; Cc in the virgin range, Cr below σ′p
  2. Eq. 2: σ′v0 = (γsat − γw) z — present effective stress
  3. Eq. 3: OCR = σ′p / σ′v0

Steps

Step 1 · Cc, 2 to 8 tsf (Eq. 1)
(1.590 − 1.235) / log(8/2) = 0.355 / 0.602
Cc = 0.590
↓
Step 2 · Cr, 0.125 to 1 tsf (Eq. 1)
(1.820 − 1.698) / log(1/0.125) = 0.122 / 0.903
Cr = 0.135
Spot check: Cr/Cc = 0.23, within the usual 0.1 to 0.25.
↓
Step 3 · σ′v0 (Eq. 2)
(115 − 62.4) × 19
999 psf = 0.50 tsf
↓
Step 4 · OCR (Eq. 3)
1.50 / 0.50
OCR = 3.0
↓
Solution
Cc = 0.590; Cr = 0.135; σ′p = 1.50 tsf; OCR = 3.0.

Solution

Cc = 0.590, Cr = 0.135, σ′p = 1.50 tsf and OCR = 3.0: a moderately overconsolidated clay.

Use the overconsolidated settlement equations of Chapter 6.2: recompression only while the final stress stays below 1.50 tsf, and recompression plus virgin compression if the embankment pushes it past. Report all four values in the engineering properties table of the geotechnical report. Cc is taken from the straight part of the curve well above σ′p, not from the bend.

Example 5.2-2: Modified Proctor and Soaked CBR

Subgrade for an intermodal yard expansion on a Class I railroad located in Kansas City. The Proctor test sets the compaction reference; the CBR is run on a specimen compacted to the specified fraction of it and soaked, which is the condition the subgrade will be in after a wet season.

1012141618110115120Water content w (%)γd (pcf)γd,max, wopt = ?Design CBR = ? Target 95%?Givenw = 10.5, 12, 14, 16, 18%γd = 111.8, 115.4, 118.2, 117.1, 113.5RC 95%CBR loads 730 lb @0.1; 960 lb @0.2 in.Standard 3,000 / 4,500 lbRequire CBR ≥ 20%Requiredγd,max, wopt and target densityDesign CBRBlack = given; red = required
Given and required for Example 5.2-2.

Given

VariableValueDescription
Proctor pointsw = 10.5, 12, 14, 16, 18%; γd = 111.8, 115.4, 118.2, 117.1, 113.5 pcfModified Proctor
RC95% (assumed)Specimen compaction
Loads730 lb at 0.1 in.; 960 lb at 0.2 in.Soaked CBR
Standard loads3,000 lb at 0.1 in.; 4,500 lb at 0.2 in.ASTM D1883
RequirementCBR ≥ 20% (assumed)Subgrade or blanket

Required

  • γd,max, wopt and target density
  • Design CBR

Equations

  1. Eq. 1: γd,target = RC × γd,max
  2. Eq. 2: CBR = P / Pstd × 100% — at 0.1 and 0.2 in.; the higher governs if the test is valid

Steps

Step 1 · Peak of the curve
γd,max = 118.2 pcf at wopt = 14.0%
↓
Step 2 · Target (Eq. 1)
0.95 × 118.2
112.3 pcf
↓
Step 3 · CBR (Eq. 2)
730/3,000; 960/4,500
24.3% and 21.3%; 0.1 in. governs
↓
Solution
Design CBR = 24%.

Solution

γd,max = 118.2 pcf at 14.0%; design CBR = 24.3%, just above the assumed 20% requirement.

A soaked CBR of 24% is high for a lean clay, which commonly tests between 3 and 15%. Before the value is used, check the specimen’s classification, compaction and soak record, and run at least three more tests across the yard footprint. If the result is confirmed, the subgrade is marginally adequate; if not, plan for a blanket layer or treatment (Chapter 7.3).

Example 5.2-3: Effective Strength From a CU Triaxial Test

A cut slope in residual silty clay on a Class I railroad located in Appalachia. Three CU specimens with pore pressure measurement give the effective strength parameters for long-term (drained) slope stability. The p′-q′ plot turns three Mohr circles into a straight line, whose slope and intercept give φ′ and c′.

0200040006000800001000200030004000Normal stress σ′ (psf)Shear stress (psf)Envelope: φ′, c′ = ?Givenσ3 = 1,000; 2,000; 3,000 psfΔuf = 400; 710; 1,050 psfq = 820; 1,540; 2,290 psfRequiredEffective φ′ and c′Black = given; red = required
Given and required for Example 5.2-3.

Given

VariableValueDescription
σ31,000; 2,000; 3,000 psfCell pressures, specimens A to C
Δuf400; 710; 1,050 psfPore pressure at failure
q820; 1,540; 2,290 psf(σ1 − σ3)/2 at failure

Required

  • Effective φ′ and c′

Equations

  1. Eq. 1: σ′3 = σ3 − Δu; σ′1 = σ′3 + 2q
  2. Eq. 2: p′ = (σ′1 + σ′3)/2
  3. Eq. 3: q = a + p′ tanα; sinφ′ = tanα; c′ = a / cosφ′ — modified failure envelope

Steps

Step 1 · Effective stresses (Eq. 1)
A: 600 and 2,240; B: 1,290 and 4,370; C: 1,950 and 6,530 psf
σ′3 and σ′1
↓
Step 2 · Centers p′ (Eq. 2)
1,420; 2,830; 4,240 psf
↓
Step 3 · Slope (Eq. 3)
(2,290 − 820)/(4,240 − 1,420) = 1,470 / 2,820
tanα = 0.521; φ′ = 31°
↓
Step 4 · Intercept and c′ (Eq. 3)
a = 1,550 − 0.521 × 2,830 = 75 psf; 75 / cos 31°
c′ ≈ 90 psf
Spot check: Specimen B: 75 + 0.521 × 2,830 = 1,550 psf, against a measured q of 1,540 psf.
↓
Solution
φ′ = 31°; c′ ≈ 90 psf.

Solution

φ′ ≈ 31° and c′ ≈ 90 psf.

These are for long-term (drained) stability. Small cohesion intercepts from three points are uncertain; for a cut slope with a factor of safety near 1.3, test at least two more specimens and consider checking the slope with c′ = 0, because weathering of a residual soil in the cut face destroys cohesion first.

← Previous · 5.0 Testing Chapter 5.1 — In Situ Testing