Railway Ground Hazard Risk Management · Reference

Typical Soil Property Ranges by USCS Group

Screening values, in English units, for the soil inputs used in the manual's equations. Each equation's Inputs table links here for the variable it needs.

Use with care. These are typical ranges compiled from the references listed under each table. They are for planning, checking test results and preliminary design only. Design values come from site-specific field and laboratory testing.

GHRM home · Appendix F, Analytical Equations · Empirical Equations reference

Contents

Unit weight, water content and index properties (natural, in-place)

In-place values for natural deposits. Fill depends on compaction; see the compaction table.

USCS group Total (moist) unit weight γ
(pcf)
Dry unit weight γd
(pcf)
Natural water content w
(%)
Specific gravity Gs
(—)
Void ratio e (porosity n = e/(1+e))
(—)
Liquid limit LL / plasticity index PI
(%)
GW Well-graded gravel125–145115–1353–152.64–2.680.25–0.45NP
GP Poorly graded gravel120–140105–1303–152.64–2.680.30–0.60NP
GM Silty gravel120–140110–1305–202.65–2.700.30–0.60fines: PI < 4 or below A-line
GC Clayey gravel120–140105–1258–202.66–2.720.35–0.65fines: PI > 7, above A-line
SW Well-graded sand115–135100–1255–202.64–2.680.35–0.70NP
SP Poorly graded sand105–13090–1155–252.64–2.680.45–0.85NP
SM Silty sand110–13095–1208–252.65–2.700.40–0.80fines: PI < 4 or below A-line
SC Clayey sand110–13095–12010–252.66–2.720.40–0.80fines: PI > 7, above A-line
ML Silt (low plasticity)100–12580–11015–402.65–2.720.50–1.10LL 20–50; PI NP–10 (below A-line)
CL Lean clay105–13080–11515–402.68–2.750.50–1.20LL 20–50; PI 7–30 (above A-line)
OL Organic silt/clay (low LL)85–11050–8535–1002.40–2.651.0–3.0LL 30–50; LLoven/LL < 0.75
MH Elastic silt90–11555–9030–802.70–2.800.9–2.0LL 50–90; PI 10–40 (below A-line)
CH Fat clay95–12560–10025–702.70–2.800.7–2.0LL 50–110; PI 25–80 (above A-line)
OH Organic clay (high LL)80–10540–8050–2002.20–2.601.5–4.0LL 50–100; LLoven/LL < 0.75
PT Peat60–805–20200–1,5001.4–2.05–15—

Sources. Holtz, Kovacs & Sheahan (2011), An Introduction to Geotechnical Engineering, 2nd ed.; Das & Sobhan (2018), Principles of Geotechnical Engineering, 9th ed.; Terzaghi, Peck & Mesri (1996), Soil Mechanics in Engineering Practice, 3rd ed. · ASTM D2487, Standard Practice for Classification of Soils for Engineering Purposes (USCS); A-line PI = 0.73(LL − 20).

Drained strength

Peak effective-stress parameters for normally consolidated or compacted soil. Undrained strength su of fine-grained soil depends on consistency and stress history, not on group: see the consistency table.

USCS group Peak effective friction angle φ'
(degrees)
Effective cohesion c'
(psf)
Residual friction angle φ'r
(degrees)
Compacted (Standard Proctor) φ' / saturated c'
(degrees / psf)
GW Well-graded gravel35–450≈ φ'cv 32–36>38 / 0
GP Poorly graded gravel33–420≈ φ'cv 32–36>37 / 0
GM Silty gravel32–400–10028–34>34 / —
GC Clayey gravel28–360–20022–30>31 / —
SW Well-graded sand33–420≈ φ'cv 30–3438 / 0
SP Poorly graded sand30–380≈ φ'cv 30–3437 / 0
SM Silty sand28–360–10026–3234 / 420
SC Clayey sand26–330–20020–2831 / 230
ML Silt (low plasticity)27–340–10024–3232 / 190
CL Lean clay24–320–25012–2528 / 270
OL Organic silt/clay (low LL)20–280–10015–25— / —
MH Elastic silt22–300–20010–2225 / 420
CH Fat clay17–260–3006–1519 / 230
OH Organic clay (high LL)15–250–1008–18— / —
PT Peat25–40*0–200*—not used as fill

Sources. Holtz, Kovacs & Sheahan (2011), An Introduction to Geotechnical Engineering, 2nd ed.; Das & Sobhan (2018), Principles of Geotechnical Engineering, 9th ed.; Terzaghi, Peck & Mesri (1996), Soil Mechanics in Engineering Practice, 3rd ed. · Stark & Eid (1994) and Stark & Hussain (2013), drained residual strength correlations with LL and clay fraction. · NAVFAC DM-7.02 (1986) / UFC 3-220-01N, Table 8-1.4 “Typical Properties of Compacted Soils” (Standard Proctor density; CBR and k at CE-55 density).

* Peat (PT): effective-stress parameters are uncertain and fiber-dependent; design with undrained strength from field vane or CPT and a settlement-based approach.

Permeability and consolidation

Hydraulic conductivity in ft/day (1 cm/s ≈ 2,835 ft/day). Consolidation parameters for normally consolidated fine-grained soil; coarse-grained soils drain during loading and are analyzed with elastic or empirical settlement methods.

USCS group Hydraulic conductivity k
(ft/day)
Coefficient of consolidation cv
(ft²/day)
Compression index Cc
(—)
Recompression index Cr (Cs)
(—)
Secondary compression Cα (as Cα/Cc)
(—)
GW Well-graded gravel10–1,000free-draining———
GP Poorly graded gravel100–10,000free-draining———
GM Silty gravel0.001–10free-draining< 0.05——
GC Clayey gravel10−5–0.010.5–100.02–0.100.005–0.02—
SW Well-graded sand1–100free-draining———
SP Poorly graded sand0.1–100free-draining———
SM Silty sand0.001–11–500.02–0.100.005–0.02—
SC Clayey sand10−5–0.010.5–100.05–0.150.01–0.030.03±0.01
ML Silt (low plasticity)10−4–0.10.5–50.10–0.350.01–0.050.04±0.01
CL Lean clay10−6–10−30.05–10.10–0.400.01–0.080.04±0.01
OL Organic silt/clay (low LL)10−5–0.010.02–0.30.40–1.00.05–0.20.05±0.01
MH Elastic silt10−5–0.010.02–0.50.35–0.750.04–0.150.04±0.01
CH Fat clay10−7–10−40.005–0.20.35–0.900.04–0.180.04±0.01
OH Organic clay (high LL)10−6–10−30.005–0.10.60–2.50.1–0.50.05±0.01
PT Peat0.001–100.05–52–100.2–1.50.075±0.01

Sources. Holtz, Kovacs & Sheahan (2011), An Introduction to Geotechnical Engineering, 2nd ed.; Das & Sobhan (2018), Principles of Geotechnical Engineering, 9th ed.; Terzaghi, Peck & Mesri (1996), Soil Mechanics in Engineering Practice, 3rd ed. · Terzaghi & Peck (1967): Cc ≈ 0.009(LL − 10) for normally consolidated clays, applied to typical LL ranges; organic and peat values from Mesri & Ajlouni (2007). · Mesri & Godlewski (1977); Mesri & Castro (1987): Cα/Cc = 0.04 ± 0.01 inorganic clays and silts, 0.05 ± 0.01 organic, 0.075 ± 0.01 peat.

Stiffness and wave velocity

Ranges span loose to dense (coarse) and soft to hard (fine). Use the density/consistency table to narrow them.

USCS group Drained Young's modulus Es
(ksf)
Poisson's ratio ν
(—)
Shear-wave velocity Vs
(ft/s)
GW Well-graded gravel1,000–4,0000.25–0.40800–2,500
GP Poorly graded gravel1,000–4,0000.25–0.40800–2,500
GM Silty gravel600–2,5000.25–0.40700–2,000
GC Clayey gravel600–2,0000.25–0.40700–2,000
SW Well-graded sand200–1,7000.25–0.40500–1,500
SP Poorly graded sand200–1,7000.25–0.40400–1,400
SM Silty sand100–1,0000.25–0.40400–1,300
SC Clayey sand100–1,0000.25–0.40400–1,300
ML Silt (low plasticity)40–4000.30–0.35350–1,000
CL Lean clay40–2,0000.20–0.40 drained; 0.50 undrained250–1,500
OL Organic silt/clay (low LL)10–2000.30–0.40150–500
MH Elastic silt40–6000.20–0.40 drained; 0.50 undrained250–1,000
CH Fat clay40–1,5000.20–0.40 drained; 0.50 undrained250–1,500
OH Organic clay (high LL)10–2000.30–0.40150–500
PT Peat2–600.10–0.30100–300

Sources. Bowles (1996), Foundation Analysis and Design, 5th ed., Tables 2-7 (Es) and 2-8 (ν), converted to ksf. · ASCE 7-22 Ch. 20 site-class velocity bands; Kramer (1996), Geotechnical Earthquake Engineering.

Compaction, subgrade support and frost

Compaction values are Standard Proctor (ASTM D698). CBR and modulus of subgrade reaction are for compacted soil. Mr is from Mr = 2,555·CBR0.64 applied to the CBR range.

USCS group Max. dry unit weight / optimum water content
(pcf / %)
California Bearing Ratio CBR
(%)
Resilient modulus Mr
(psi)
Modulus of subgrade reaction k
(pci)
Frost susceptibility group (USACE)
(—)
Thermal conductivity, frozen kf
(BTU/hr·ft·°F)
GW Well-graded gravel125–135 / 8–1140–8027,000–42,000300–500NFS–F11.4–2.4
GP Poorly graded gravel115–125 / 11–1430–6022,000–35,000250–400NFS–F11.4–2.4
GM Silty gravel120–135 / 8–1220–6017,000–35,000100–400F1–F31.2–2.0
GC Clayey gravel115–130 / 9–1420–4017,000–27,000100–300F1–F31.2–2.0
SW Well-graded sand110–130 / 9–1620–4017,000–27,000200–300NFS–F21.4–2.4
SP Poorly graded sand100–120 / 12–2110–4011,000–27,000200–300NFS–F21.4–2.4
SM Silty sand110–125 / 11–1610–4011,000–27,000100–300F2–F41.2–2.0
SC Clayey sand105–125 / 11–195–207,000–17,000100–300F2–F31.2–2.0
ML Silt (low plasticity)95–120 / 12–24≤ 15≤ 14,000100–200F40.8–1.4
CL Lean clay95–120 / 12–24≤ 15≤ 14,00050–200F3 (PI > 12) / F4 (PI < 12)0.8–1.4
OL Organic silt/clay (low LL)80–100 / 21–33≤ 5≤ 7,00050–100F40.5–1.0
MH Elastic silt75–95 / 24–40≤ 10≤ 11,00050–100F40.8–1.4
CH Fat clay80–105 / 19–36≤ 15≤ 14,00050–150F30.8–1.4
OH Organic clay (high LL)75–100 / 21–45≤ 5≤ 7,00025–100F30.5–1.0
PT Peatnot suitable————0.2–0.8

Sources. NAVFAC DM-7.02 (1986) / UFC 3-220-01N, Table 8-1.4 “Typical Properties of Compacted Soils” (Standard Proctor density; CBR and k at CE-55 density). · AASHTO (2008) MEPDG Manual of Practice: Mr (psi) = 2,555·CBR0.64. · UFC 3-130-01 / TM 5-822-5 frost-susceptibility groups F1–F4 (based on % finer than 0.02 mm and PI). · Kersten (1949) thermal properties of soils, as used in UFC 3-130-06 (TM 5-852-6); depends on γd and w.

Density of coarse-grained soil (GW, GP, GM, GC, SW, SP, SM, SC)

Density state, not group, sets these values. Use (N1)60 and qc1N for depth-normalized comparisons.

DensityDr (%)N60 (blows/ft)qc (tsf)φ' (degrees)
Very loose0–150–4< 2028–30
Loose15–354–1020–4030–32
Medium dense35–6510–3040–12032–36
Dense65–8530–50120–20036–40
Very dense85–100> 50> 20040–45

Sources. Terzaghi & Peck (1967); Meyerhof (1956); Kulhawy & Mayne (1990), Manual on Estimating Soil Properties for Foundation Design, EPRI EL-6800. φ' ranges are for clean sand; add 2–5° for well-graded gravelly soil.

Consistency of fine-grained soil (ML, CL, OL, MH, CH, OH)

Undrained strength follows consistency and stress history. Normally consolidated clays typically have su/σ'v ≈ 0.20–0.25 (Mesri 1975; Ladd 1991). CPT: su ≈ (qt − σv)/Nkt, Nkt ≈ 10–18.

Consistencysu (psf)N60 (blows/ft)qt − σv (tsf, Nkt ≈ 14)
Very soft< 250< 2< 5
Soft250–5002–45–8
Medium stiff500–1,0004–88–15
Stiff1,000–2,0008–1515–30
Very stiff2,000–4,00015–3030–60
Hard> 4,000> 30> 60

Sources. Terzaghi & Peck (1967) consistency classes; ASTM D2488; FHWA GEC-5 (2017), Geotechnical Site Characterization. N60 correlations in clay are approximate; prefer vane, CPT or lab tests.

How each property is obtained

The same text appears in each equation's Inputs table.

PropertyComes fromHow to get it
Total unit weight γLab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).
Dry unit weight γdLab or field testLab: ASTM D7263 on tube samples. Field: nuclear gauge (ASTM D6938), sand cone (D1556) or drive cylinder (D2937). Or γd = γ/(1 + w).
Buoyant unit weight γ'Another equationγ' = γsat − γw (γw = 62.4 pcf). Use below the water table.
Max. dry unit weight γd,maxLab testProctor compaction test: Standard (ASTM D698) or Modified (ASTM D1557), as the spec requires.
Water content wLab testOven-dry water content of samples (ASTM D2216); field check by microwave (D4643) or nuclear gauge (D6938).
Specific gravity GsLab testSpecific gravity of solids (ASTM D854). 2.65–2.70 is usually adequate for mineral soils when untested.
Void ratio eAnother equatione = Gsγw/γd − 1, from Gs and γd; e0 for consolidation is reported by the consolidation test (ASTM D2435).
Liquid limit LLLab testAtterberg limits (ASTM D4318) on the minus No. 40 fraction.
Plasticity index PILab testPI = LL − PL from Atterberg limits (ASTM D4318).
Fines contentLab testPercent passing No. 200 sieve: washed sieve analysis (ASTM D1140 / D6913).
Grain size D10–D85Lab testGrain-size curve: sieve (ASTM D6913) plus hydrometer for fines (ASTM D7928). Read D10, D30, D50, D60, D85 from the curve.
Friction angle φ'Lab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).
Residual friction angle φ'rLab test (or correlation)Ring shear (ASTM D6467) or reversal direct shear (D3080); or Stark correlations with LL and clay fraction.
Cohesion c'Lab testEffective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more.
Undrained strength suLab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.
Hydraulic conductivity kField or lab testField: pumping test, slug test (ASTM D4044) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only.
Coefficient of consolidation cv, chLab test (or field)Consolidation test (ASTM D2435 or D4186), log-time or root-time fit at the design stress range. ch from CPTu dissipation tests.
Compression index CcLab testSlope of the virgin e–log σ' curve from a consolidation test (ASTM D2435). Screening: Cc ≈ 0.009(LL − 10).
Recompression index CrLab testUnload–reload slope of the e–log σ' curve (ASTM D2435). Screening: Cr ≈ Cc/5 to Cc/10.
Secondary compression CαLab testSlope of e vs log time after primary consolidation in the consolidation test (ASTM D2435).
Preconsolidation stress σ'p / OCRLab test (or correlation)Preconsolidation stress from the consolidation curve (Casagrande or work method, ASTM D2435). CPT screening: σ'p ≈ 0.33(qt − σv). OCR = σ'p/σ'v0.
Elastic modulus EsField test, lab test or correlationPressuremeter (ASTM D4719), DMT (D6635), plate load (D1196), triaxial secant modulus, or correlation with N60 or qc.
Poisson's ratio νAssumed (published values)Rarely measured; choose from published ranges. Use 0.5 for undrained clay.
Shear-wave velocity VsField testSeismic CPT, downhole or crosshole (ASTM D4428 / D7400), or MASW surface waves.
SPT N60Field testStandard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633) to correct to N60.
CPT qc, qt, fs, u2Field testCone penetration test with pore pressure (CPTu, ASTM D5778).
Relative density DrAnother equation (or correlation)From emax/emin tests (ASTM D4253/D4254) and in-place e, or from SPT/CPT correlations.
CBRLab or field testLab CBR (ASTM D1883, soaked) on compacted samples; field CBR (D4429); or from DCP (ASTM D6951) correlation.
Resilient modulus MrLab test (or correlation)Repeated-load triaxial (AASHTO T 307), or Mr ≈ 2,555·CBR0.64 (MEPDG).
Subgrade modulus kField test (or correlation)Plate load test (ASTM D1196 / AASHTO T 222), or correlation with CBR or Mr.
Thermal conductivity kfPublished dataKersten charts in UFC 3-130-06 (TM 5-852-6) for the measured γd and w.
At-rest coefficient K0Another equationK0 = 1 − sin φ' (NC), × OCRsin φ' for OC soil (Jaky; Mayne & Kulhawy). Field: DMT or self-boring pressuremeter.
Interface friction δLab test (or fraction of φ')Interface direct shear (ASTM D5321); otherwise δ = 0.6–1.0 φ' depending on the surface (steel, concrete, geosynthetic).
Rock UCSLab testUniaxial compression of rock core (ASTM D7012); point load index (D5731) for screening.

Compiled by D. P. Colwell for the GHRM manual, November 2026. Ranges transcribed or derived from the cited references; verify against the originals before design use.