Gravity walls resist sliding and overturning through their own mass. Common materials include mass concrete and dry-laid or mortared stone masonry. Practical retained height limit is approximately 12–15 ft for mass concrete.


Factor of Safety Against Sliding:
FS_sliding = (W × tan δ_base + c_base × B) / P_A_total ≥ 1.5 (AREMA Ch. 8)
where:


Factor of Safety Against Overturning:
FS_OT = ΣM_resisting / ΣM_overturning ≥ 2.0 (AREMA Ch. 8)
Resultant Eccentricity:
e = B/2 − (ΣM_resisting − ΣM_overturning) / ΣV (ft)
For no tension at the base, the middle-third rule requires:
e ≤ B/6
This is the usual requirement for gravity and cantilever walls on soil supporting track; confirm the owner railroad's criterion (rock foundations may allow more eccentricity).
Bearing Pressure at Toe:
q_toe = (ΣV/B) × (1 + 6e/B) (psf)
Bearing Pressure at Heel:
q_heel = (ΣV/B) × (1 − 6e/B) (psf)
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| W | total vertical weight of wall + retained soil on heel (lb/ft) | Another equation | Area of the slice, wedge or wall section from the cross-section geometry × unit weight γ (from lab tests). | project-specific |
| δbase | friction angle at base (degrees) | Lab test (or fraction of φ') | Interface direct shear (ASTM D5321); otherwise δ = 0.6–1.0 φ' depending on the surface (steel, concrete, geosynthetic). | 0.6–1.0 φ' · by USCS group |
| cbase | base adhesion (psf) | Lab test | Effective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more. | 0–300 psf · by USCS group |
| B | base width (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| PAtotal | total active force including surcharge (lb/ft) | Loading criteria | From the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications. | project-specific |
| e | void ratio = B/2 − ( ΣM_resisting − ΣM_overturning ) / ΣV (ft) | Another equation | e = Gsγw/γd − 1, from Gs and γd; e0 for consolidation is reported by the consolidation test (ASTM D2435). | sands 0.35–0.85, clays 0.5–2.0 · by USCS group |


Cantilever walls use a reinforced concrete stem and footing to resist overturning. The critical design section is at the base of the stem. Retained heights of 10–25 ft are typical.
Stem base moment (per foot of wall):
M_stem = (K_A × γ × H³/6) + (K_A × q_design × H²/2) (ft·lb/ft)
Minimum embedment depth for adequate passive resistance:
d_min is determined by setting FS_sliding ≥ 1.5 with the contribution of passive resistance over the embedded depth of the footing toe.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| γ | total (moist) unit weight | Lab test | Weigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w). | sands 105–135, clays 95–130 pcf · by USCS group |
MSE walls use reinforced fill to develop internal stability. They are commonly preferred for retained heights of 10–40 ft where ROW permits adequate fill width. MSE walls are commonly designed to AASHTO LRFD Bridge Design Specifications in addition to AREMA Chapter 8.





Internal stability checks include:
External stability checks (sliding, overturning, bearing) use the MSE mass as an equivalent gravity wall.
Owner railroads may require a minimum cover of unreinforced structural fill between the top reinforcement layer and the ballast for MSE walls next to live track; confirm it.
Soldier pile walls use steel H-piles driven or drilled at 6–8 ft spacing with timber lagging. They are commonly used for temporary shoring during cut construction and for permanent retained cuts in urban railroad corridors where MSE fill width is unavailable.

Required embedment depth below excavation for cantilever soldier piles (simplified method):
(1/6) × K_p × γ × d³ = P_A × (ȳ + d), per foot of wall, taking moments about the pile tip; ȳ = height of P_A above the excavation level. For discrete soldier piles, apply the passive resistance over an effective width of about 2–3 pile widths.
Solve iteratively for d; common practice increases d by 20–40% for design.
Size timber lagging for the span and soil type (FHWA GEC 4).
Sheet pile walls (steel) are used for waterfront structures, scour protection, and temporary cofferdams. Free-earth support method for cantilever sheet piles:

d_theoretical is determined by moment equilibrium; common practice increases d_theoretical by 20–40% (USACE instead factors the passive strength; see the box below).
Anchored sheet pile walls use tie rods to reduce embedment depth and moment demand. The anchor force:
T_A = P_A − P_P (horizontal force equilibrium, free-earth support)
Owner railroads may require coated or encapsulated steel sheet piles for permanent waterfront applications where tidal or chemically aggressive conditions exist.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| γ | total (moist) unit weight | Lab test | Weigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w). | sands 105–135, clays 95–130 pcf · by USCS group |
Soil nail walls are constructed top-down and are well suited to cuts in stiff clays, dense sands, and weathered rock. Nail design:
T_design = σ_h × S_v × S_h / FS_nail (lb)
Pullout resistance per unit length: Q_u = π × d_borehole × q_s (lb/ft) where q_s is the unit skin friction (psf)
FHWA GEC 7 (FHWA-NHI-14-007, 2015) recommends a global stability FS of 1.5 for permanent soil nail walls. AREMA Chapter 1 (Section 2.3.3) lists soil nail walls among slope repair methods and says they must be designed by an experienced engineer.
Where a ballast shoulder or fill slope has slumped away from the ties and there is no room or time for a conventional wall, a micropile–tieback facing can be built from the embankment crest within track windows. Two projects in the AREMA Committee 1 files, both by GeoStabilization International (2018), show the arrangement:






Why micropiles fit railroad sites (SHRP2): they can be drilled through any ground, including boulders, rubble fill and old ballast, at any angle, with small rigs, low noise and little spoil (low-headroom rigs work under 10 ft clearance). Capacity comes from grout-to-ground bond (toe resistance neglected), so tension and compression capacities are about equal. At least about 40% of the load is carried by the steel. Capacities commonly exceed 200 tons in soil and 500 tons in rock, and most are under 100 ft long. Limitations: high slenderness (check buckling in very soft or liquefiable soil), and the method depends on contractor drilling and grouting skill, so load testing is essential.
Composite gabion walls (gabion facing combined with tiebacks, soil nails, reinforced concrete beams or drilled shafts) are marketed on the same principle — less excavation behind the face than a gravity gabion or cantilever wall — which matters when the excavation would otherwise undermine the track.


Source: GeoStabilization International (2018). Micropile Tieback Railroad Shoulder Repair, Class I railroad located in Illinois — drawings and construction photographs. AREMA Committee 1 files · GeoStabilization International (2018). Class I railroad Yard Culvert Wall — Micropile Cap (drawings). AREMA Committee 1 files · SHRP2 R02 / GeoTechTools (2012). Micro-piles — fact sheet


Section 7.1.4.5 increases the theoretical embedment by 1.3. EM 1110-2-2504 takes a different approach: it applies a strength-reduction factor to the passive side only (tan φeff = tan φ/FSP; ceff = c/FSP), uses best estimates elsewhere, and usually takes FSA = 1 unless wall deformation must be limited. It then solves directly for the penetration. The two approaches do not give the same depth; do not apply both.
Table 16-S1. Minimum FS on passive pressure for penetration depth (EM 1110-2-2504, Table 5-1, retaining walls)
| Loading case | Fine-grained soils | Free-draining soils |
|---|---|---|
| Usual | 2.00 Q-case; 1.50 S-case | 1.50 S-case |
| Unusual | 1.75 Q-case; 1.25 S-case | 1.25 S-case |
| Extreme | 1.50 Q-case; 1.10 S-case | 1.10 S-case |
Other USACE points relevant to track walls: in medium-dense or denser sand, the active state develops at about 0.1–0.2% of wall height (about ¼–½ in. for a 20-ft wall), while full passive needs about 2–4% (roughly 5–10 in.). This is why passive resistance should be discounted where track settlement is critical. For anchored walls, the Free Earth method gives stable walls with less penetration than Fixed Earth but overpredicts moment (use Rowe’s moment reduction). Initially place the anchor at ¼–⅓ of the exposed height below the top. Grouted anchors must lie entirely outside the active wedge and develop the tie-rod yield strength. Proof-test every anchor to 110% of required resistance and performance-test at least two to 150% of design capacity.
Source: U.S. Army Corps of Engineers (1994). Design of Sheet Pile Walls. EM 1110-2-2504
Lines along coasts, lakes and large rivers often depend on revetments, seawalls or bulkheads. EM 1110-2-1614 sizes armor stone by Hudson’s equation:
W = γrH3 / [KD(γr/γw − 1)3 cot θ]
where W is the armor unit weight (W50 for graded riprap) and H is the design wave height. Suggested KD for breaking waves: rough angular quarrystone, two layers, random 2.0 (1.2 for smooth rounded); graded riprap 2.2 (slopes 2.0–6.0 cot θ). A single layer of randomly placed rough stone is “do not use”, and graded riprap is not recommended where waves exceed 5 ft. For irregular waves on dumped riprap, the zero-damage stability number is Nsz = 1.14 cot1/6 θ with Hs.
Source: U.S. Army Corps of Engineers (1995). Design of Coastal Revetments, Seawalls, and Bulkheads. EM 1110-2-1614
For very tall embankment sides, Profillidis shows either a conventional retaining wall at the toe or reinforced soil: an assembly of good-quality granular backfill, metallic reinforcing bars or strips anchored in the fill, and a concrete facing. Reinforced soil is recommended particularly on poor and very poor subgrades (S1, S0) and allows very steep or vertical faces. A French cost comparison for railway projects found reinforced soil economically and technically advantageous over a retaining wall, especially at heights of 10–40 ft (Figure 7.1-13).











Caution for electrified lines. The book states that metallic-reinforced soil cannot be used on electrified railways, because return current corrodes the metal reinforcement and can lead to failure. Where a reinforced-soil wall is proposed near an electrified line or a DC transit system, address stray-current corrosion explicitly. Options include non-metallic (geosynthetic) reinforcement or a corrosion design that accounts for stray current.
After Profillidis (2014), §9.12.2, §9.13, Figs. 9.16–9.18. Full reference under Supplemental References.
Use a wall when a berm cannot be placed. Driven walls isolate the track from shallow-to-medium movement below but are not efficient against deep-seated failures. H-pile walls along the shoulder use piles about 4 ft apart. If movement continues, add a whaler so the piles act together; if it still moves, add soil anchors or tie back to piles on the far side of the grade. Rule of thumb: to hold 4 ft of unstable ground, embed at least 8 ft below the slip plane. At one Atlantic Canada site, a tidal bank retrogressing toward the track was treated with a temporary riprap toe berm and then a design combining 55-ft H-piles with a 40-ft sheet-pile wall.









After Geotechnology for Railroaders Program, Module 6.1; §05–07, §10. Full reference under Supplemental References.
Cretu et al. argue that risk assessment and value engineering (VE) belong together, because risk analysis characterizes the problems and VE generates the solutions. VE, also called value methodology, is a facilitated multidiscipline study built on function analysis. It asks what an element must do rather than what it is, and that is what separates it from simple cost cutting. For each high or moderate risk they add a function-based step to response planning:


Reducing a long risk narrative to a short function statement keeps the team focused on the thing that can actually be managed. It also tends to produce several candidate solutions instead of one.
For railroad work: Wall selection is a natural application. Suppose the risk is “soft clay below the planned cantilever wall may cause excessive rotation under E-80 surcharge.” The risk object is the foundation. The response functions might be “avoid foundation” (a lightweight-fill embankment or a pile-supported wall), “mitigate settlement” (ground improvement or preloading where a track window allows), “transfer design” (a performance-specified proprietary system) and “accept movement” (a flexible MSE or gabion wall with a resurfacing allowance). Screening these against track-outage limits, construction access from the right-of-way, and the railroad’s preferences for wall type gives a short list. The short list can then be ranked by weighted paired-comparison scoring and compared on a whole-life cost basis.
Source: Cretu, O., Stewart, R. and Berends, T. (2011). Risk Management for Design and Construction. Hoboken, NJ: John Wiley & Sons, pp. 157–162. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.
Soldier piles and lagging are this manual's standard wall next to track. Below the excavation the piles act as discrete elements, not a continuous wall, and the passive resistance per pile is more than the plane-strain value over the pile width. UK guidance (CIRIA C580, summarised in Pickles, 2012, pp. 995–996) gives the ultimate net resistance per pile when the spacing s is more than three pile widths b.
Equation 7.1-6. Ultimate passive resistance of a discrete pile, per unit depth
Pickles (2012), Eqs. 64.5–64.8, after Barton (1982) and Fleming et al. (1994). Divide by s for resistance per foot of wall. Kp = (1 + sinφ′)/(1 − sinφ′); valid for Kp = 3.0 to 5.3 (30° ≤ φ′ ≤ 43°). z is depth below the excavation and p′v the effective overburden there. Vol. II prints “≤” in both depth limits; the second limit of each pair is evidently ≥, where the deeper expression takes over.
Full active pressure is assumed on the retained side. The Kp² form is close to the 3Kp rule (Broms) used in many U.S. guidelines at Kp = 3 and higher at larger Kp; follow the governing railroad shoring guideline where it prescribes a method (Section 7.1.17).
Excavation unloads the clay in front of the wall; as negative pore pressures dissipate, the clay near the excavation base softens. Take the undrained strength as zero at the excavation level, rising to the design value at a depth L (Pickles, 2012, Eq. 64.4, p. 994):
Equation 7.1-7. Depth of softened clay below an excavation
cv = coefficient of consolidation; t = time the excavation is open. Use L of about 1.6 ft (0.5 m) where no groundwater recharge is possible.
For example, with cv = 0.1 ft²/day, L is about 4.1 ft after two weeks and about 10 ft after three months, which can remove much of the passive resistance a short embedment relies on. Also allow for unplanned over-excavation in front of the wall: 10% of the retained height, up to about 1.6 ft (0.5 m), in Eurocode practice (Pickles, 2012, p. 985).
Equation 7.1-8. Fixed anchor length from bond (skin friction)
Turner (2012), Eqs. 66.1–66.6, pp. 1017–1021. d = borehole diameter; L = fixed (bond) length; τ = grout–ground bond from load tests or published values; F = global factor (Vol. II recommends retaining the BS 8081 global factors).
Soldier piles in 2-ft drilled holes at 8-ft spacing support an excavation beside track. Below the excavation the soil is dense sand. Find the ultimate passive resistance per pile at 5 ft below the excavation and compare it with the 3Kp rule.
| Variable | Value | Description |
|---|---|---|
| b | 2 ft | Pile (drilled hole) width |
| s | 8 ft | Pile spacing (s > 3b = 6 ft) |
| φ′ | 34° | Sand below excavation |
| γ | 120 pcf | Unit weight (above groundwater) |
| z | 5 ft | Depth below excavation |
This is an ultimate value; apply the factor of safety or the reduced passive coefficient that the governing railroad shoring guideline requires before using it to find embedment.
In clay, replace this with the undrained form and reduce the strength near the excavation base by the softened depth L.
Paraphrased from the published sources below; values are converted to English units. Individual railroads, clients and projects are not named.