↑ Parent Menu⌂ Main Menu
← Chapter 7.1 Retaining Structures
GHRM
Railway Ground Hazard Risk Management · 7.0 · Design
Sections · click a car to open it

7.1.18 Cantilever Sheet Pile Walls by the Blum Method

Retaining structures are among the most consequential geotechnical elements in railroad capital programs.
Authors: Daniel P. Colwell and Mario Ruel
7.1.18 Cantilever Sheet Pile Walls by the Blum Method

Steel sheet piles are the usual choice where a cut next to track has to be made quickly, in soft or water-bearing ground, or where the wall will be pulled when the work is done. A cantilever wall stands on its embedment alone: the soil in front of the toe pushes back as passive resistance, and a reverse pressure develops near the tip as the wall rotates about a point a little above it. The European sheet piling handbooks in the library simplify that reverse pressure, following Blum, into a single force at the theoretical toe. Embedment comes from moment equilibrium about that point, and the depth is then increased by about 20% so the reverse pressure can actually develop. For permanent railroad walls the manual still assumes soldier piles with lagging; sheet piles are covered here for temporary shoring and for sites where soldier piles cannot be drilled or driven.

7.1.18.1 Method

Equation 7.1-4. Blum equilibrium for a cantilever wall in cohesionless soil

x3 = m·x + n,   m = 6Q0/c,   n = 6M0/c,   c = γ(Kph/γEp − γGKah)

t = u + x  (Blum allowance Δt = 0.2t, driven length 1.2t);   Mmax = M0 + 0.385·Q0·√m

Here Q0 and M0 are the shear and moment from the active pressure at the point of zero net pressure, a distance u below the dredge line, and x is the depth from that point to the theoretical toe. The handbook's worked example, in metric units, gives m = 9.90 and n = 20.14, which solve to x = 3.88 m, so the embedment is t = u + x = 4.46 m, to which Blum's driving allowance Δt = 0.2t = 0.89 m is added. The calculator does not rely on the closed form. It integrates the factored active pressure (Coulomb, with wall friction), any uniform surcharge, and the Boussinesq strip pressure from an E80 axle group (80,000 lb spread over 5 ft by the tie length) when track is behind the wall, and it solves ΣM = 0 about the toe by bisection. With no surcharge and no wall friction the numerical solution matches the Blum result to within 0.1%.

Table 7.1-9. Sheet pile design items and typical values
ItemValue usedBasis
Active pressureCoulomb Kah with δa = 2/3φHandbook practice for steel against soil
Passive pressureKph with δp = 0 (Rankine) unless test data support more, divided by 1.5Partial factor on resistance
Driving allowanceΔt = 0.2t (Blum)Allows the reverse pressure to develop
Track live loadE80 strip, BoussinesqChapter 7.1 temporary shoring sections
Clearance to trackNo excavation within 12 ft of centerlineRailroad temporary shoring guidelines
Corrosion, natural soilabout 0.01 mm (0.0004 in.) per year per exposed faceEAU 2004, as cited in the handbook

7.1.18.2 Worked example

A 10 ft cut in sand (γ = 120 pcf, φ = 32°) with a 250 psf construction surcharge and no track: Kah/Kph = 0.256 / 3.255, equilibrium embedment 11.47 ft, embedment with the Blum allowance 13.76 ft, maximum moment 19,844 ft-lb/ft and a required section modulus of 7.2 in.³/ft at 33.3 ksi. Put the same wall 13 ft from track centerline with the E80 strip in place of the 250 psf surcharge and the embedment grows to 21.35 ft, the moment to 71,179 ft-lb/ft and the section modulus to 25.7 in.³/ft. Train load, not the soil, sets the section. For a permanent wall the 50-year corrosion loss at the handbook rate is 0.040 in. of total thickness, which reduces the section modulus that remains at the end of its life.

Deflection usually governs before stress does. Railroad shoring guidelines limit cantilever sheet piles next to track to granular soils or stiff clays, and they cap shoring movement at 3/8 in. (and rail movement at 1/4 in.) for walls 12 to 18 ft from centerline, and at 1/2 in. for walls 18 to 24 ft away. Check deflection with a beam-on-springs model before accepting the section from this calculator.

Open the cantilever sheet pile calculator →
Coulomb pressures, E80 strip surcharge, numerical moment equilibrium for embedment, the Blum driving allowance, maximum moment, required section modulus and corrosion loss.

7.1.18.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated limits are standard or published values. Individual railroads, clients and projects are not named.

  • Sheet Piling Handbook: Design (ThyssenKrupp GfT Bautechnik and HSP Hoesch), and the Sheet Piling Handbook, 3rd edition: Blum's method, the worked cantilever example, earth pressure with wall friction, partial factors, and corrosion ratesFind source ↗Library entry
  • M. Stuart, Steel Sheet Piling, PDH course S151A (2012): U.S. practice for cantilever and anchored sheet pile walls, section selection and drivingFind source ↗Library entry
  • A Class I railroad's guidelines for temporary shoring: the 12 ft clearance, the E80 surcharge, and deflection limitsFind source ↗
  • M.F. Ashby and D.R.H. Jones, Engineering Materials 1: An Introduction to Properties, Applications and Design, 3rd edition: corrosion rates and protective measures for steelFind source ↗
← Previous · 6.0 Analysis Chapter 6.6 — Tunnels and Portals