The CPT advances a 1.41-in.-diameter cone at a rate of 0.8 in./sec per ASTM D5778. The standard cone has a projected tip area of 1.55 in² and a friction sleeve area of 23.25 in². The piezocone (CPTu) adds a porous filter element — typically at the u₂ position (shoulder behind tip) — to measure pore water pressure during advancement.
Measurements recorded per ASTM D5778:
For CPTu, the measured tip resistance is corrected for unequal area effects:
q_t = q_c + u₂ × (1 − a)
Where:
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| qt | CPT tip resistance = q_c + u₂ × (1 − a) | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
| qc | measured tip resistance (tsf) | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
| u₂ | measured pore water pressure at shoulder (tsf) | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
| a | net area ratio of cone (dimensionless) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | typically 0.75–0.85 |

The friction ratio is used for soil behavior type (SBT) classification:
R_f (%) = (f_s / q_c) × 100
Robertson (1990) SBT zones are used to classify soil type without physical samples. A simplified guide:
| SBT Zone | R_f (%) | q_c (tsf) | Typical Soil |
|---|---|---|---|
| 1 | >4 | <5 | Sensitive fine-grained |
| 2 | >3 | 5–25 | Organic / peat |
| 3 | 2–4 | 5–50 | Clay — low to medium OCR |
| 4 | 1–2 | 10–100 | Silt mixture |
| 5 | 0.5–1.5 | 50–200 | Sand mixture |
| 6 | <0.5 | >100 | Clean sand |
| 7 | <0.5 | >300 | Dense sand / gravel |
| 9 | >2 | >100 | Very stiff fine-grained |

| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| qt | CPT tip resistance | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
No additional content.
s_u = (q_t − σ_v) / N_kt
Where:
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| su | undrained shear strength = (q_t − σ_v) / N_kt | Lab or field test | Lab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening. | soft 250–500, stiff 1,000–2,000 psf · by USCS group |
| qt | corrected tip resistance (tsf) | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
| σv | total vertical stress at depth of interest (tsf) = γ × z / 2,000 [γ in pcf, z in ft, result in tsf] | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
| Nkt | cone factor (dimensionless) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | typically 10–18 |
| γ | total (moist) unit weight | Lab test | Weigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w). | sands 105–135, clays 95–130 pcf · by USCS group |
B_q = (u₂ − u₀) / (q_t − σ_v)
Where u₀ = hydrostatic pore pressure (tsf) = γ_w × h_w / 2,000; γ_w = 62.4 pcf, h_w = depth below water table (ft). B_q > 0.4 typically indicates soft, normally consolidated or sensitive clay — a critical flag on high-speed passenger corridor and Class I railroad alignments located in the Great Lakes region.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Bq | CPT tip resistance = (u₂ − u₀) / (q_t − σ_v) | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
| u₀ | hydrostatic pore pressure (tsf) = γ_w × h_w / 2,000 | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
| γw | 62.4 pcf, h_w = depth below water table (ft) | Constant | Physical constant or standard value. | typically indicates soft, normally consolidated or sensitive clay — a critical flag on Amt |
Chapter 6.5 presents the full liquefaction procedure; the key normalized parameter needed from CPT is:
q_c1N = (q_c / P_a) × (P_a / σ'_v)^0.5
Where:
Confirm with the owner railroad whether CPT-based screening is accepted for the project.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| qc1N | CPT tip resistance = (q_c / P_a) × (P_a / σ'_v)^0.5 | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
| qc | measured tip resistance (tsf) | Field test | Cone penetration test with pore pressure (CPTu, ASTM D5778). | loose sand 20–40, dense 120–200 tsf · by USCS group |
| Pa | 2,117 psf = 1.058 tsf | Constant | Physical constant or standard value. | project-specific |
| σ'v | vertical effective stress (tsf) | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
The non-normalized zones in Section 5.1.2.3 drift with depth because qc rises with overburden. Robertson’s normalized chart (Figure 7-S1) removes that effect and collapses the zone boundaries into one number:

Ic = [ (3.47 − log Qt)2 + (log Fr + 1.22)2 ]0.5, with Qt = (qt − σvo)/σ′vo and Fr = fs/(qt − σvo) × 100%.
| Zone | Soil behavior type | Ic | (qc/pa)/N60 |
|---|---|---|---|
| 1 | Sensitive, fine grained | N/A | 2.0 |
| 2 | Organic soils – clay | > 3.6 | 1.0 |
| 3 | Clays – silty clay to clay | 2.95–3.6 | 1.5 |
| 4 | Silt mixtures – clayey silt to silty clay | 2.60–2.95 | 2.0 |
| 5 | Sand mixtures – silty sand to sandy silt | 2.05–2.60 | 3.0 |
| 6 | Sands – clean sand to silty sand | 1.31–2.05 | 5.0 |
| 7 | Gravelly sand to dense sand | < 1.31 | 6.0 |
| 8 | Very stiff sand to clayey sand* | N/A | 5.0 |
| 9 | Very stiff fine-grained* | N/A | 1.0 |

* Heavily overconsolidated or cemented. Normalized SBT has better than 80% agreement with samples in independent studies (Robertson & Cabal, 2010). Apply the q/N ratios to qt in soft fine-grained soils.
Stopping the push and recording pore-pressure decay gives t50, the time to 50% dissipation, which yields the horizontal coefficient of consolidation (Robertson and Cabal report accuracy of about ± half an order of magnitude but excellent repeatability within a profile). Convert to vertical with cv = ch(kv/kh). Watch for dilative silts where u2 rises before it falls — run the test to true equilibrium, or measure t50 from the peak. In plastic clays dissipation can take many hours, so budget rig time accordingly on track-window-limited projects.
Robertson and Cabal recommend recording zero-load readings at the start and end of every sounding and checking wear, O-ring seals, push rods and the pore-pressure filter at the start and end of each test, with load-cell calibration at least every three months (or before and after major projects).
Source: Robertson, P. K. and Cabal, K. L. (2010). Guide to Cone Penetration Testing for Geotechnical Engineering, 4th ed. Gregg Drilling & Testing, Inc.
About 400 ft of track on a Class I railroad line located in northern Alberta was settling differentially into deep peat. Boreholes (including DH-1 and DH-3) built the stratigraphic section, and a track-mounted CPT rig filled in between them to define the depth and extent of the organic layer. The resulting design used 68 piles of 18-in. diameter, installed in two flights at 10° from vertical, to carry track load through the peat (see Chapter 6.1). Simple hand checks also help: at another site in the Rocky Mountain trench, clay that a thumb could penetrate an inch or more ruled out heavy equipment and rain-day work.


After Geotechnology for Railroaders Program, Module 6.2, Module 6.1; Module 6.2 §05; Module 6.1 §03. Full reference under Supplemental References.
The cone penetration test gives a continuous profile in minutes, which suits a long corridor where thin soft layers and lenses matter more than a few samples. Look's Handbook of Geotechnical Investigation and Design Tables and the FHWA's Evaluation of Soil and Rock Properties (GEC 5) give the standard interpretation. The tip resistance is corrected for pore pressure acting behind the cone. Soil type is judged from the friction ratio, checked against tip resistance and the pore-pressure ratio. Strength, stress history and friction angle then follow from empirical correlations. A dissipation test gives the horizontal coefficient of consolidation, the property that controls the wick drain design in Chapter 7.2. Simons, Menzies and Matthews' Short Course in Geotechnical Site Investigation and the Corps of Engineers' EM 1110-1-1804 place the CPT within an investigation and recommend calibrating it against borings and laboratory tests.
| Quantity | Relationship | Source |
|---|---|---|
| Corrected tip resistance | qt = qc + (1 − a)u2 | Look |
| Friction ratio; pore pressure ratio | FR = fs/qt; Bq = (u2 − u0)/(qt − σvo) | Look |
| Soil type from FR | < 1% coarse to medium sand; 1–2% fine or silty sand; 2–5% clays; > 5% peat | Look, Table 5.13 |
| Undrained strength | su = (qt − σvo)/Nkt, Nkt about 10 to 20 (15 typical) | GEC 5, Table 33 |
| Preconsolidation stress | σ′p = 0.33(qt − σvo) | GEC 5, Eq. 41 |
| Friction angle, clean sand | φ′ = 17.6° + 11.0 log[(qc/pa)/(σ′vo/pa)0.5] | GEC 5 |
| Horizontal consolidation | ch = T*a²√Ir/t50, T* = 0.245 (u2) | GEC 5 (Teh and Houlsby) |
The example sounding passes through 6 ft of dense sand fill, about 12 ft of soft clay, and dense sand below. The clay readings give su as low as 479 psf with Nkt = 15. A dissipation test at a 6.9-minute t50 (the same reading and rigidity index as GEC 5's worked example, which gives 29 × 10−3 cm²/s) gives ch = 2.64 ft²/day. That value goes straight into the wick drain calculator. The sands give φ′ of about 41° to 42°. Near the surface the correlation tends to run high because the overburden stress is small.
Open the CPTu interpretation calculator →
Corrected tip resistance, friction ratio, Bq, soil type, undrained strength, OCR and friction angle for each reading, plus ch from a dissipation test, with a depth profile.
| U (%) | 1 − U | T*, filter at mid-face (u1) | T*, filter behind the tip (u2) |
|---|---|---|---|
| 20 | 0.8 | 0.014 | 0.038 |
| 30 | 0.7 | 0.032 | 0.078 |
| 40 | 0.6 | 0.063 | 0.142 |
| 50 | 0.5 | 0.118 | 0.245 |
| 60 | 0.4 | 0.226 | 0.439 |
| 70 | 0.3 | 0.463 | 0.804 |
| 80 | 0.2 | 1.04 | 1.60 |
U is measured from the initial excess pore pressure, not the peak reading, where the two differ.
| Test | Relationship |
|---|---|
| Cone (CPT) | σ′p = 0.33(qT − σvo) |
| Piezocone, face element | σ′p = 0.47(u1 − u0) |
| Piezocone, shoulder element | σ′p = 0.54(u2 − u0) |
| Flat dilatometer | σ′p = 0.51(p0 − u0) |
| Self-boring pressuremeter | σ′p = 0.45pL |
| Field vane | σ′p = 3.54su,VST |
Fissured clays fall outside these trends; benchmark against oedometer tests.
| NkT | Matches undrained strength from |
|---|---|
| 10 | Triaxial compression |
| 15 | Direct simple shear (common default) |
| 20 | Triaxial extension |
GEC 5 notes that 15 is a commonly used value, but the right factor depends on the deposit; calibrate it against laboratory or vane strengths.
| Bq | Non-cohesive | Cohesive |
|---|---|---|
| 0.0 to 0.2 | Dense sand (qT > 52 tsf, 5 MPa) | Hard or stiff overconsolidated soil (qT > 104 tsf, 10 MPa) |
| 0.0 to 0.4 | Medium or loose sand (21 to 52 tsf, 2 to 5 MPa) | Stiff clay or silt (10 to 21 tsf, 1 to 2 MPa) |
| 0.2 to 0.8 | Firm clay or fine silt (qT < 10 tsf, 1 MPa) | |
| 0.8 to 1.0 | Soft clay (qT < 5 tsf, 0.5 MPa) | |
| > 0.8 | Very soft clay (qT < 2 tsf, 0.2 MPa) |
1 MPa is about 10.4 tsf.
The dissipation method was checked against GEC 5's worked example (a u2 cone, radius 0.70 in. (1.78 cm), Ir = 230). The table repeats the calculation at every stage of dissipation. The computed ch rises as dissipation proceeds, so state which stage was used; the calculator uses the 50% value. The profile below is the worked example sounding, with qt and the undrained strength interpreted in the clay.
| Normalized excess pore pressure | T* (u2) | Time (min) | ch, GEC 5 (10−3 cm²/s) | ch, recomputed |
|---|---|---|---|---|
| 0.8 | 0.038 | 1.9 | 16 | 16 |
| 0.7 | 0.078 | 3.1 | 20 | 20 |
| 0.6 | 0.142 | 4.6 | 25 | 25 |
| 0.5 | 0.245 | 6.9 | 29 | 28 |
| 0.4 | 0.439 | 10.4 | 34 | 34 |
| 0.3 | 0.804 | 15.9 | 41 | 40 |
| 0.2 | 1.600 | 26 | 49 | 49 |
These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.