Primary Reference: USACE EM 1110-1-1804, Geotechnical Investigations, 1 January 2001, Chapters 8–9 Railroad Standards: AREMA MRE Chapter 1 & 8; the owner railroad's current engineering standards
Typical Values for This Chapter — from the GHRM Soil & Rock Properties Database
SPT-based consistency and density descriptors and in situ test variability. English units; every value cites its library source, table and page. For preliminary design and checking test results, not a substitute for site testing.
| Property | Soil / material | Class | Condition | Low | Typical | High | Units | Source |
|---|---|---|---|---|---|---|---|---|
| Undrained shear strength | Clay | CL-CH | Very soft | 251 | psf | LOOK T2.14 / 5.3, p.50 | ||
| Undrained shear strength | Clay | CL-CH | Soft | 251 | 386.5 | 522 | psf | LOOK T2.14 / 5.3, p.50 |
| Undrained shear strength | Clay | CL-CH | Firm | 522 | 783 | 1,044 | psf | LOOK T2.14 / 5.3, p.50 |
| Undrained shear strength | Clay | CL-CH | Stiff | 1,044 | 1,566 | 2,088 | psf | LOOK T2.14 / 5.3, p.50 |
| Undrained shear strength | Clay | CL-CH | Very stiff | 2,088 | 3,132 | 4,177 | psf | LOOK T2.14 / 5.3, p.50 |
| Undrained shear strength | Clay | CL-CH | Hard | 4,177 | psf | LOOK T2.14 / 5.3, p.50 | ||
| Unconfined compressive strength | Cohesive soil | CL-CH | Very soft (N < 2) | 0.25 | tsf | IDOT T4.4.6.1.2-2, p.119 | ||
| Unconfined compressive strength | Cohesive soil | CL-CH | Soft (N = 2–4) | 0.25 | 0.375 | 0.5 | tsf | IDOT T4.4.6.1.2-2, p.119 |
| Unconfined compressive strength | Cohesive soil | CL-CH | Medium stiff (N = 4–8) | 0.5 | 0.75 | 1 | tsf | IDOT T4.4.6.1.2-2, p.119 |
| Unconfined compressive strength | Cohesive soil | CL-CH | Stiff (N = 8–15) | 1 | 1.5 | 2 | tsf | IDOT T4.4.6.1.2-2, p.119 |
| Unconfined compressive strength | Cohesive soil | CL-CH | Very stiff (N = 15–30) | 2 | 3 | 4 | tsf | IDOT T4.4.6.1.2-2, p.119 |
| Unconfined compressive strength | Cohesive soil | CL-CH | Hard (N > 30) | 4 | 6 | 8 | tsf | IDOT T4.4.6.1.2-2, p.119 |
| SPT N-value | Cohesive soil | CL-CH | Very soft | 0 | 0.5 | 1 | blows/ft | GEC5 T23, p.137 |
| SPT N-value | Cohesive soil | CL-CH | Soft | 2 | 3 | 4 | blows/ft | GEC5 T23, p.137 |
| SPT N-value | Cohesive soil | CL-CH | Medium stiff | 5 | 6.5 | 8 | blows/ft | GEC5 T23, p.137 |
| SPT N-value | Cohesive soil | CL-CH | Stiff | 9 | 12 | 15 | blows/ft | GEC5 T23, p.137 |
| SPT N-value | Cohesive soil | CL-CH | Very stiff | 16 | 23 | 30 | blows/ft | GEC5 T23, p.137 |
| SPT N-value | Cohesive soil | CL-CH | Hard | 31 | 45.5 | 60 | blows/ft | GEC5 T23, p.137 |
| SPT N-value | Cohesive soil | CL-CH | Very hard | 60 | blows/ft | GEC5 T23, p.137 | ||
| SPT N-value | Granular soil | GW-SM | Very loose | 4 | blows/ft | LOOK T2.15, p.50 | ||
| Relative density | Granular soil | GW-SM | Very loose | 15 | % | LOOK T2.15, p.50 | ||
| SPT N-value | Granular soil | GW-SM | Loose | 4 | 7 | 10 | blows/ft | LOOK T2.15, p.50 |
| Relative density | Granular soil | GW-SM | Loose | 15 | 25 | 35 | % | LOOK T2.15, p.50 |
| SPT N-value | Granular soil | GW-SM | Medium dense | 10 | 20 | 30 | blows/ft | LOOK T2.15, p.50 |
| Relative density | Granular soil | GW-SM | Medium dense | 35 | 50 | 65 | % | LOOK T2.15, p.50 |
| SPT N-value | Granular soil | GW-SM | Dense | 30 | 40 | 50 | blows/ft | LOOK T2.15, p.50 |
| Relative density | Granular soil | GW-SM | Dense | 65 | 75 | 85 | % | LOOK T2.15, p.50 |
| SPT N-value | Granular soil | GW-SM | Very dense | 50 | blows/ft | LOOK T2.15, p.50 | ||
| Relative density | Granular soil | GW-SM | Very dense | 85 | % | LOOK T2.15, p.50 | ||
| Undrained shear strength | Clay | CL-CH | Very soft | 418 | psf | CRAIG T4.1, p.121 | ||
| Undrained shear strength | Clay | CL-CH | Soft | 418 | 626.5 | 835 | psf | CRAIG T4.1, p.121 |
| Undrained shear strength | Clay | CL-CH | Firm | 835 | 1,200 | 1,566 | psf | CRAIG T4.1, p.121 |
| Undrained shear strength | Clay | CL-CH | Stiff | 1,566 | 2,350 | 3,133 | psf | CRAIG T4.1, p.121 |
| Undrained shear strength | Clay | CL-CH | Very stiff | 3,133 | 4,700 | 6,266 | psf | CRAIG T4.1, p.121 |
| Undrained shear strength | Clay | CL-CH | Hard | 6,266 | psf | CRAIG T4.1, p.121 | ||
| Density index (relative density) | Sand | SP-SW | Very loose (N = 0–4) | 0 | 7.5 | 15 | % | CRAIG T8.3, p.309 |
| Normalized SPT value | Sand | SP-SW | Very loose (N = 0–4) | 0 | 1.5 | 3 | blows/ft | CRAIG T8.3, p.309 |
| Density index (relative density) | Sand | SP-SW | Loose (N = 4–10) | 15 | 25 | 35 | % | CRAIG T8.3, p.309 |
| Normalized SPT value | Sand | SP-SW | Loose (N = 4–10) | 3 | 5.5 | 8 | blows/ft | CRAIG T8.3, p.309 |
| Density index (relative density) | Sand | SP-SW | Medium dense (N = 10–30) | 35 | 50 | 65 | % | CRAIG T8.3, p.309 |
| Normalized SPT value | Sand | SP-SW | Medium dense (N = 10–30) | 8 | 16.5 | 25 | blows/ft | CRAIG T8.3, p.309 |
| Density index (relative density) | Sand | SP-SW | Dense (N = 30–50) | 65 | 75 | 85 | % | CRAIG T8.3, p.309 |
| Normalized SPT value | Sand | SP-SW | Dense (N = 30–50) | 25 | 33.5 | 42 | blows/ft | CRAIG T8.3, p.309 |
| Density index (relative density) | Sand | SP-SW | Very dense (N > 50) | 85 | 92.5 | 100 | % | CRAIG T8.3, p.309 |
| Normalized SPT value | Sand | SP-SW | Very dense (N > 50) | 42 | 50 | 58 | blows/ft | CRAIG T8.3, p.309 |
| Presumed allowable bearing value (BS 8004) | Dense gravel, or dense sand and gravel | GW, GP, SW | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 12.5 | ksf | CURTIN T1.1, p.5 | ||
| Presumed allowable bearing value (BS 8004) | Medium dense gravel, or sand and gravel | GW, GP, SW | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 4.2 | 8.3 | 12.5 | ksf | CURTIN T1.1, p.5 |
| Presumed allowable bearing value (BS 8004) | Loose gravel, or sand and gravel | GW, GP, SW | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 4.2 | ksf | CURTIN T1.1, p.5 | ||
| Presumed allowable bearing value (BS 8004) | Compact sand | SW, SP | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 6.3 | ksf | CURTIN T1.1, p.5 | ||
| Presumed allowable bearing value (BS 8004) | Medium dense sand | SW, SP | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 2.1 | 4.2 | 6.3 | ksf | CURTIN T1.1, p.5 |
| Presumed allowable bearing value (BS 8004) | Loose sand | SW, SP | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 2.1 | ksf | CURTIN T1.1, p.5 | ||
| Presumed allowable bearing value (BS 8004) | Very stiff boulder clay and hard clay | CL, CH | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 6.3 | 9.4 | 12.5 | ksf | CURTIN T1.1, p.5 |
| Presumed allowable bearing value (BS 8004) | Stiff clay | CL, CH | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 3.1 | 4.7 | 6.3 | ksf | CURTIN T1.1, p.5 |
| Presumed allowable bearing value (BS 8004) | Firm clay | CL, CH | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 1.6 | 2.35 | 3.1 | ksf | CURTIN T1.1, p.5 |
| Presumed allowable bearing value (BS 8004) | Soft clay and silt | CL, CH, ML | Footing width ≥ 3.3 ft; groundwater ≥ B below base | 1.6 | ksf | CURTIN T1.1, p.5 | ||
| Undrained strength of clay from hand-sample identification | Clay | Very soft | Extrudes between fingers | 420 | psf | ATKINSON T5.2, p.61 | ||
| Undrained strength of clay from hand-sample identification | Clay | Soft | Easily molded in fingers | 420 | 630 | 840 | psf | ATKINSON T5.2, p.61 |
| Undrained strength of clay from hand-sample identification | Clay | Firm | Molded by strong finger pressure | 840 | 1,205 | 1,570 | psf | ATKINSON T5.2, p.61 |
| Undrained strength of clay from hand-sample identification | Clay | Stiff | Cannot be molded in fingers | 1,570 | 1,830 | 2,090 | psf | ATKINSON T5.2, p.61 |
| Undrained strength of clay from hand-sample identification | Clay | Very stiff | Can be indented by thumbnail | 3,130 | psf | ATKINSON T5.2, p.61 |
| Property | Soil / material | Class | Condition | Low | Typical | High | Units | Source |
|---|---|---|---|---|---|---|---|---|
| CPT–SPT ratio (qc/pa)/N60 | Sensitive fine-grained | SBT zone 1 | 2 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Organic soils – clay | SBT zone 2 | 1 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Clays – silty clay to clay | SBT zone 3 | 1.5 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Silt mixtures – clayey silt to silty clay | SBT zone 4 | 2 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Sand mixtures – silty sand to sandy silt | SBT zone 5 | 3 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Sands – clean sand to silty sand | SBT zone 6 | 5 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Dense sand to gravelly sand | SBT zone 7 | 6 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Very stiff sand to clayey sand (OC or cemented) | SBT zone 8 | 5 | – | ROB T5, p.41 | |||
| CPT–SPT ratio (qc/pa)/N60 | Very stiff fine-grained (OC or cemented) | SBT zone 9 | 1 | – | ROB T5, p.41 |
| Property | Soil / material | Class | Condition | Low | Typical | High | Units | Source |
|---|---|---|---|---|---|---|---|---|
| Coefficient of variation of in situ test | Standard penetration test | Equipment + procedure + random | 15 | 30 | 45 | % | LOOK T10.3, p.137 | |
| Coefficient of variation of in situ test | Mechanical cone penetration test | Equipment + procedure + random | 15 | 20 | 25 | % | LOOK T10.3, p.137 | |
| Coefficient of variation of in situ test | Self-boring pressuremeter | Equipment + procedure + random | 15 | 20 | 25 | % | LOOK T10.3, p.137 | |
| Coefficient of variation of in situ test | Vane shear test | Equipment + procedure + random | 10 | 15 | 20 | % | LOOK T10.3, p.137 | |
| Coefficient of variation of in situ test | Pressuremeter, prebored | Equipment + procedure + random | 10 | 15 | 20 | % | LOOK T10.3, p.137 | |
| Coefficient of variation of in situ test – measurement error | Standard penetration test (SPT) | Total probable range | 15 | 30 | 45 | % | FGE T31.5, p.480 | |
| Coefficient of variation of in situ test – measurement error | Mechanical cone (MCPT) | Total probable range | 15 | 15 | 25 | % | FGE T31.5, p.480 | |
| Coefficient of variation of in situ test – measurement error | Electric cone (ECPT) | Total probable range | 5 | 7 | 15 | % | FGE T31.5, p.480 | |
| Coefficient of variation of in situ test – measurement error | Vane shear test (VST) | Total probable range | 10 | 14 | 20 | % | FGE T31.5, p.480 | |
| Coefficient of variation of in situ test – measurement error | Dilatometer (DMT) | Total probable range | 5 | 11 | 15 | % | FGE T31.5, p.480 | |
| Coefficient of variation of in situ test – measurement error | Pressuremeter, prebored (PMT) | Total probable range | 10 | 16 | 20 | % | FGE T31.5, p.480 | |
| Coefficient of variation of in situ test – measurement error | Self-boring pressuremeter (SBPMT) | Total probable range | 15 | 19 | 25 | % | FGE T31.5, p.480 |
| Property | Soil / material | Class | Condition | Low | Typical | High | Units | Source |
|---|---|---|---|---|---|---|---|---|
| Vertical scale of fluctuation | Clay – su | Lab testing | 2.6 | 15.4 | 28.2 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Clay – su | Vane shear | 6.6 | 13.4 | 20.3 | ft | FGE T31.6, p.484 | |
| Horizontal scale of fluctuation | Clay – su | Vane shear | 150.9 | 173.9 | 196.9 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Sand, clay – qc | CPT | 0.3 | 5.05 | 9.8 | ft | FGE T31.6, p.484 | |
| Horizontal scale of fluctuation | Sand, clay – qc | CPT | 9.8 | 136.2 | 262.5 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Offshore soils – qc | CPT | 1 | 1.15 | 1.3 | ft | FGE T31.6, p.484 | |
| Horizontal scale of fluctuation | Offshore soils – qc | CPT | 45.9 | 85.3 | 124.7 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Clay – qt | CPTu | 0.7 | 1.15 | 1.6 | ft | FGE T31.6, p.484 | |
| Horizontal scale of fluctuation | Clay – qt | CPTu | 75.5 | 146 | 216.5 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Cohesive-behavior soils – qc1N | CPT | 0.3 | 1.15 | 2 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Intermediate-behavior soils – qc1N | CPT | 1 | 2.15 | 3.3 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Cohesionless-behavior soils – qc1N | CPT | 1.3 | 2.45 | 3.6 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Sand – fs | CPT | 4.3 | ft | FGE T31.6, p.484 | |||
| Vertical scale of fluctuation | Cohesive-behavior soils – Ic | CPT | 0.7 | 1.15 | 1.6 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Intermediate-behavior soils – Ic | CPT | 2 | ft | FGE T31.6, p.484 | |||
| Vertical scale of fluctuation | Cohesionless-behavior soils – Ic | CPT | 1 | 2.45 | 3.9 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Sand – N | SPT | 7.9 | ft | FGE T31.6, p.484 | |||
| Vertical scale of fluctuation | Clay, loam – w | Lab testing | 5.2 | 23.5 | 41.7 | ft | FGE T31.6, p.484 | |
| Horizontal scale of fluctuation | Clay, loam – w | Lab testing | 557.8 | ft | FGE T31.6, p.484 | |||
| Vertical scale of fluctuation | Clay, loam – wL | Lab testing | 5.2 | 16.9 | 28.5 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Clay, loam – γ | Lab testing | 7.9 | 16.9 | 25.9 | ft | FGE T31.6, p.484 | |
| Vertical scale of fluctuation | Organic silty clay – e | Lab testing | 9.8 | ft | FGE T31.6, p.484 | |||
| Vertical scale of fluctuation | Organic silty clay – σ′p | Lab testing | 2 | ft | FGE T31.6, p.484 | |||
| Horizontal scale of fluctuation | Organic silty clay – σ′p | Lab testing | 590.6 | ft | FGE T31.6, p.484 | |||
| Vertical scale of fluctuation | Sand – ln(Dr) | SPT | 12.1 | ft | FGE T31.6, p.484 | |||
| Horizontal scale of fluctuation | Sand – ln(Dr) | SPT | 219.8 | ft | FGE T31.6, p.484 | |||
| Vertical scale of fluctuation | Sand – n | – | 21.3 | ft | FGE T31.6, p.484 | |||
| Horizontal scale of fluctuation | Sand – n | – | 10.8 | ft | FGE T31.6, p.484 |
| Property | Soil / material | Class | Condition | Low | Typical | High | Units | Source |
|---|---|---|---|---|---|---|---|---|
| Boring spacing along track alignment | Subgrade strength zone: Very high to high | New track or rehabilitation | 500 | ft | LI16 T8.1, p.358 | |||
| Boring spacing along track alignment | Subgrade strength zone: Medium | New track or rehabilitation | 200 | ft | LI16 T8.1, p.358 | |||
| Boring spacing along track alignment | Subgrade strength zone: Low to very low | New track or rehabilitation | 100 | ft | LI16 T8.1, p.358 | |||
| Casing diameter requiring test borings under track | Class I railroad pipeline crossings | Borings each side of track on the crossing centerline | 48 | in | RRPIPE1 T3.1.1, p.11 | |||
| Class I railroad public project investigation | Boring series spacing along line | 1,320 | ft | RRGEO text, p.1 | ||||
| Class I railroad public project investigation | Borings per series | 3 | each | RRGEO text, p.1 | ||||
| Class I railroad public project investigation | Cut-section boring depth below proposed ditch flowline | 5 | ft | RRGEO text, p.1 | ||||
| Bridge boring depth (Class I railroad) | Below spread footing | 2 | × footing width | RRBRG text, p.1 | ||||
| Bridge boring depth (Class I railroad) | Below estimated pile tip | From preliminary static analysis | 10 | ft | RRBRG text, p.1 |
Full database · Laboratory tests · Download Excel · Library documents for this chapter · Calculators for this chapter
Borings and sampling form the physical backbone of every geotechnical investigation we conduct for railroad clients. Whether we are planning a simple passing siding for a short line, upgrading a high-density mainline corridor for the owner railroads, or characterizing a soft-ground embankment for high-speed passenger corridor, the quality of subsurface data we deliver is only as good as the drilling methods, sampling protocols, and documentation we employ in the field. This chapter covers the full spectrum of boring techniques used in railroad geotechnical practice — hollow-stem auger, mud rotary, air rotary, and diamond core drilling — alongside standard sampling methods including the Split-Spoon Sampler (SPT), Shelby tube, piston sampler, and rock coring. Emphasis is placed on the complete SPT correction chain required for quantitative analysis, the preservation of sample quality for laboratory testing, and the documentation standards expected by Class I carriers and regional railroads alike. Worked calculation examples, a fully annotated boring log, and a representative laboratory data table are provided. The chapter closes with a field operations checklist, practical recommendations developed from active railroad project experience, and five practice questions with complete answers.
The correlations used in this chapter are listed below. Each gives an estimate, not a test result. The full equation, variables, range of applicability, constraints and source for each one, and the note to record whenever one is used, are in the Empirical Equations & Correlations reference.
| ID | Correlation | Gives |
|---|---|---|
| IS-01 | SPT energy & procedure correction | N₆₀ |
| IS-02 | SPT overburden normalization (sands) | (N₁)₆₀ |
| RK-10 | UCS from point load index | σ꜀ |
| IS-03 | Relative density of sand from SPT | Dᵣ |
| IS-05 | Friction angle of sand from SPT (Peck–Hanson–Thornburn) | φ' |
| IS-07 | Undrained shear strength of clay from SPT | Sᵤ |
| RK-04 | RQD from volumetric joint count | RQD |
For railroad clients, a boring log is not merely a field record — it is a legal and contractual document. Owner railroads commonly require subsurface investigation records in an approved format, retained for the life of the facility. Confirm the owner railroad's minimum boring log content and sample chain-of-custody requirements when the work is scoped. When our boring logs and sample records are weak, inaccurate, or incomplete, we expose both the client and our firm to design liability, change order disputes, and construction failures.
AREMA's Manual for Railway Engineering (MRE), Chapter 1, Part 1 (Section 2.1, Exploration and Testing), gives guidance on investigations for roadbed and earthwork. AREMA Chapters 8 and 15 define the Cooper E-80 live load and impact allowances for structures, and this manual uses dynamic load factors of about 1.3 to 1.5 for track substructure (Chapter 2.3). Subsurface data must cover the depths these loads influence for the track and structure configuration at hand. Our boring programs must be designed with these loading demands explicitly in mind, and the report should state how each boring depth was chosen.
Boring logs should meet the minimum data requirements of ASTM D5434 and be accompanied by a chain-of-custody record for all SPT and undisturbed samples. Record water content at every sample interval and describe drilling fluid returns during mud rotary drilling.
Our commitment to boring quality is therefore both a technical and a business imperative. A well-executed boring program, thoroughly documented and delivered in the client's preferred format, is a direct competitive advantage in railroad geotechnical practice.
The UIC subgrade classes ( Chapter 2.3, Section 2.3.4 ) are assigned from a short list of parameters. If track-subgrade borings are to support that classification, or a comparison with it, the sampling plan must recover them through the top 6.5 ft of subgrade, the depth Profillidis gives as mechanically affected by train loading:
After Profillidis (2014), §7.2, §9.5, Table 9.2. Full reference under Supplemental References.
Hollow-stem auger drilling is the preferred method for most railroad embankment, subgrade, and shallow foundation investigations where soil conditions permit. HSA allows continuous sample recovery through the auger stem without removing the drill string, minimizing borehole disturbance and reducing the risk of borehole collapse in granular soils above the water table.

Applicable client contexts:
Limitations: HSA is not appropriate in running sands below the water table (where heave into the auger stem is common), in hard or cemented soils, in rock, or where boring depths exceed approximately 100–120 ft. In these conditions, mud rotary or air rotary methods are substituted.
Equipment specifications:
Mud rotary drilling uses a pressurized fluid — typically a bentonite-water slurry — to cool the bit, carry cuttings to the surface, and stabilize the borehole wall. It is the preferred method for deep investigations (greater than approximately 100 ft), for offshore or waterway bridge site investigations, and for any condition where borehole stability cannot be maintained with HSA.
Applicable client contexts:
Critical operational note for railroad right-of-way: All drilling fluid returns must be captured and removed from the ROW. Drilling mud discharged onto active track subgrade will breach most railroad right-of-way agreements and can lead to suspension of field work. We require closed-loop mud pits or portable fluid containment systems on all mud rotary jobs conducted within 50 ft of active track.
Air rotary drilling uses compressed air (and in some cases air-foam mixtures) to circulate cuttings and cool the bit. It is the preferred method in rock or very hard soils where drilling fluid is impractical, and is commonly used to advance through casing in overburden before transitioning to diamond core in the rock zone.
Applicable client contexts:
Diamond core drilling recovers continuous cylindrical cores of intact rock for geomechanical characterization. Core drilling is required for any railroad structure with rock-socketed drilled shaft foundations, for tunnel portal and cut investigations, and for any project where bearing on rock or side resistance in rock is a foundation design parameter.
Core barrel sizes used in railroad practice:
| Size | OD (in.) | Core Diameter (in.) | Typical Use |
|---|---|---|---|
| NQ | 2.98 | 1.88 | Deep exploration; limited recovery in fractured rock |
| HQ | 3.78 | 2.50 | Standard size for most railroad bridge foundations |
| PQ | 4.83 | 3.35 | Large-diameter cores; used for tunnel and major structure investigations |
Some owner railroads require HQ-size core or larger for bridge foundation investigations where drilled shafts are anticipated; confirm when the work is scoped.
Shallow subgrade samples are taken with shovels, backhoes or hand augers; hand-auger depth is limited by how easily the auger can be pulled, so a powered auger sometimes advances the hole. Deep embankment sampling uses a drilling contractor: split-spoon SPT (ASTM D1586; 2-in. sampler driven 18 in. by a 140-lb hammer falling 30 in.) and Shelby tubes (ASTM D1587, withdrawn 2024; 3-in. × 30-in. thin-wall tube pushed hydraulically). For mud spots and soft track, a hand-dug trench across the shoulder is often the fastest way to see the layering, the water and the failure zone. At one Class I railroad subgrade repair, test pits confirmed subgrade conditions before the toe berm and cross trenches were designed.






After Geotechnology for Railroaders Program, Module 2, Module 3, Module 6.2; Module 2 §10; Module 3 §11; Module 6.2 §02. Full reference under Supplemental References.
Case study: 4.1.14.1 Auger versus core: when crushed rock is logged as soil (Look 2023), in Section 4.1.14 Case Studies.
The Standard Penetration Test is the single most important field test in railroad geotechnical practice. Nearly every design parameter used in embankment stability, foundation bearing capacity, settlement, and liquefaction analysis for our railroad clients is either directly derived from SPT N-values or calibrated against them. Executing the SPT correctly — and applying the complete correction chain before using N-values in analysis — is a non-negotiable quality standard.

Procedure:
Refusal: If 50 blows are required for less than 6 in. of penetration, the test is terminated and recorded as refusal at the applicable penetration depth.
The raw SPT N-value is meaningless for quantitative analysis without correction to a standard energy level of 60% of the theoretical free-fall energy. The corrected value, designated N₆₀, is calculated as:
Where:
Measure and report hammer energy for each SPT rig (ASTM D4633, withdrawn 2025). Measure energy for each rig with an SPT analyzer (for example a PDA with instrumented rods) at the start of each field mobilization, and report the measured E_m values in the investigation report.

| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| N60 | SPT blow count = N_raw × E_m × C_B × C_R × C_S 0.60 | Field test | Standard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633, withdrawn 2025) to correct to N60. | loose sand 4–10, dense 30–50 blows/ft · by USCS group |
| Em | hammer energy ratio (energy delivered / theoretical energy) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | ≈ 0.80–0.85 |
| CB | borehole diameter correction: 1.00 for 2.5–4.5 in | Test setup | Dimension of the test equipment or specimen: from the test standard or the lab/field test record. | project-specific |
| CR | rod length correction: 0.75 for rod length < 10 ft | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| CS | sampler correction: 1.00 for split spoon without liner | Test setup | Dimension of the test equipment or specimen: from the test standard or the lab/field test record. | project-specific |
For liquefaction and relative density analyses, N₆₀ is further corrected to a reference overburden stress of one atmosphere (P_a = 2,117 psf, about 1.06 tsf) to yield (N₁)₆₀:
Where:
Note: C_N is capped at 1.7 (Youd et al. 2001) to prevent unrealistically high corrections at low effective stress (shallow depth).
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| CN | intermediate value computed on this page | Another equation | Computed: C_N = √ P_a σ'_v ≤ 1.7 | project-specific |
| (N1)60 | SPT blow count = C_N × N60 | Field test | Standard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633, withdrawn 2025) to correct to N60. | loose sand 4–10, dense 30–50 blows/ft · by USCS group |
| Pa | atmospheric pressure = 2,117 psf = 1.0 tsf | Constant | Physical constant or standard value. | project-specific |
| σ'v | vertical effective stress at the test depth (psf) | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
| Material | N₆₀ (blows/ft) | Relative Density / Consistency |
|---|---|---|
| Sand | 0–4 | Very Loose |
| Sand | 4–10 | Loose |
| Sand | 10–30 | Medium Dense |
| Sand | 30–50 | Dense |
| Sand | > 50 | Very Dense / Refusal |
| Clay | 0–2 | Very Soft |
| Clay | 2–4 | Soft |
| Clay | 4–8 | Medium Stiff |
| Clay | 8–15 | Stiff |
| Clay | 15–30 | Very Stiff |
| Clay | > 30 | Hard |
Energy and rod corrections cannot fix a badly run test. GEC 5 (after Kulhawy and Mayne, 1990) lists the field causes and which way they push N:
Table 6-S3. Factors affecting SPT results
| Cause | Effect | Influence on N |
|---|---|---|
| Inadequate cleaning of hole | Test not in original soil; trapped soil compressed in sampler | Increases |
| Water head not maintained in borehole | Bottom of hole becomes quick | Decreases |
| Careless measure of drop | Energy varies, usually low | Increases |
| Hammer weight inaccurate | Energy varies 5–7% commonly | Either |
| Hammer strikes collar eccentrically | Energy reduced | Increases |
| No free fall (stiff rope, ungreased sheave, > 2 turns on cathead) | Energy reduced | Increases |
| Sampler driven above bottom of casing | Driven in disturbed, densified soil | Increases greatly |
| Non-standard sampler | Correlations invalid | Either |
| Coarse gravel or cobbles | Sampler plugged or impeded | Increases |
| Bent drill rods | Energy transfer inhibited | Increases |
Note that most errors increase N — i.e., they are unconservative. GEC 5 also notes that Skempton’s tabulated energy ratios (donut 0.5–1.0, safety 0.7–1.2, automatic 0.8–1.5 as CE = ER/60) are guidance only; measure ER per ASTM D4633 (withdrawn 2025).
Source: Sabatini, P. J. et al. (2002). Evaluation of Soil and Rock Properties. Geotechnical Engineering Circular No. 5, FHWA-IF-02-034 (superseded by GEC 5, Geotechnical Site Characterization, FHWA-NHI-16-072 (2017))
Case study: 4.1.14.2 SPT field values: counting error and three rigs on one site (Look 2023), in Section 4.1.14 Case Studies.
Silts and fine sands below the water table. In very fine sand and silt below the water table, the sampler drives faster than the pore water can drain. Dense soils dilate and develop suction, so the blow count reads high. The correction attributed to Terzaghi, and recommended by Tomlinson, reduces blow counts above 15:
N′ = 15 + ½ (N − 15) for N > 15; no correction for N ≤ 15
Apply it to the field N in saturated silts and very fine or silty sands before the energy and overburden corrections, when the N value will be used for relative density, friction angle or bearing. Do not apply it when using the liquefaction methods, which were calibrated on N values without it.
Which N the density table applies to. The Terzaghi and Peck relative-density limits for sand in Section 4.1.3.4 (0–4, 4–10, 10–30, 30–50, over 50) are good average values for normally consolidated natural sands once the blow counts are corrected for both energy and overburden, that is, for (N1)60 (Skempton 1986). Use (N1)60 with that table for sand; the clay consistency rows are read with N60.
Dynamic probes. Continuous dynamic probes are driven without a borehole and record blows per 4 in. (100 mm). The super-heavy probe (DPSH) has the SPT hammer, drop and diameter, so three consecutive 4-in. counts add up to an equivalent N. For other probes, an equivalent N in granular soil follows from assuming that penetration is proportional to the energy per blow and inversely proportional to the cone area:
NSPT = (Mp Fp As Ps) / (Ms Fs Ap Pp) × probe blows
where M and F are the hammer weight and drop, A is the end area, P is the penetration per recorded count, and subscripts s and p refer to the SPT (140 lb, 30 in., about 3.0 in.², 12 in.) and the probe. For the heavy probe (DPH: 110 lb, 19.7 in., 1.72-in. cone of 2.33 in.², counted per 4 in.) this gives N ≈ 2 × DPH blows per 4 in. There is no such equivalence in clay, where the probe’s rod friction and the soil’s rate effects differ; use probe results in clay only with correlations calibrated to that probe.
For railroad work: Fine sands and silts below the water table are common in floodplain approaches, culvert and bridge foundations, and tracks on old lake beds. Note on the boring log where the Terzaghi correction was applied, so later users do not apply it twice or leave it out of a liquefaction check. Dynamic probes are a quick way to fill gaps between borings along a track shoulder or embankment toe. Correlate them to the SPT at one or two borings on the job before using the conversion, and stop the probe where rod friction builds up in clay.
Source: Carter, M. and Bentley, S. P. (2016). Soil Properties and their Correlations, 2nd ed., §3.3.2–3.3.3, Eqs. 3.13 and 3.15. Summarized and paraphrased; probe dimensions converted to US units. Full reference under Supplemental References.
A culvert under a main line of a Class I railroad located in Louisiana is to be replaced with a jacked pipe. A boring at the jacking pit found fine silty sand below a water table 8 ft deep. At 25 ft an automatic hammer with a measured energy ratio of 82% recorded N = 31, with 3 ft of rod stick-up. A heavy dynamic probe (DPH) pushed beside the boring recorded 14 blows per 4 in. at the same depth. The engineer must correct the blow count, classify the density of the sand for the jacking-pit design, and check the probe against the boring.
| Variable | Value | Description |
|---|---|---|
| N | 31 | Field blow count at 25 ft, fine silty sand below the water table |
| Em | 0.82 | Measured hammer energy ratio (automatic hammer) |
| Rod length | 28 ft | 25 ft plus 3 ft stick-up: CR = 0.95 |
| CB, CS | 1.00, 1.00 | 4-in. borehole; standard sampler |
| Water table | 8 ft | γ = 120 pcf above, 125 pcf below; γw = 62.4 pcf |
| DPH | 14 blows per 4 in. | Heavy dynamic probe beside the boring, same depth |
(a) N′ = 23. (b) N60 = 30 and (N1)60 = 31. (c) Medium dense to dense with the fine-sand correction; dense without it. (d) The probe gives N ≈ 28, which agrees with the field blow count.
For the jacking-pit design, take the sand as medium dense. The uncorrected value would overstate the friction angle by a few degrees and understate the face pressure needed to keep the silty sand from running into the pipe. Fine silty sand below the water table is also the soil most likely to flow into a jacking pit or under a pipe face, so the dewatering and face-support plan matters more than the exact density class. Record on the log that the Terzaghi correction was used for the design values. Use the uncorrected N60 for any liquefaction check. Because the probe agrees with the boring, further probes can fill in the profile along the pipe alignment between borings.
Thin-walled Shelby tube samples are the standard method for recovering nominally undisturbed specimens of soft to medium stiff cohesive soils for consolidation, triaxial, and direct shear testing. The degree of sample disturbance is quantified by the Area Ratio (AR):

Where:
For a standard 3-in. OD Shelby tube with 2.875-in. ID:
An area ratio of 10% or less is the usual criterion for undisturbed sampling (Hvorslev; see Section 4.1.16). Standard 3-in. thin-walled tubes (ASTM D1587, withdrawn 2024) meet it.
Sample Quality Designation (SQD) per Lunne et al. (1997) for clays with OCR 1–2, based on the void ratio change (Δe/e₀) when the specimen is reloaded to the in situ stress in the consolidation test:
| Δe/e₀ | Sample Quality |
|---|---|
| < 0.04 | Very good to excellent |
| 0.04–0.07 | Good to fair |
| 0.07–0.14 | Poor |
| > 0.14 | Very poor |
Report sample quality (SQD) for Shelby tube samples used in consolidation analysis. Where undrained strength of soft clay governs design, specify fixed-piston samplers rather than open push tubes.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| AR | intermediate value computed on this page | Another equation | Computed: AR = D_e^2 - D_i^2 D_i^2 × 100% | project-specific |
| De | outside diameter of the tube cutting edge (in.) | Test setup | Dimension of the test equipment or specimen: from the test standard or the lab/field test record. | project-specific |
| Di | inside diameter of the tube (in.) | Test setup | Dimension of the test equipment or specimen: from the test standard or the lab/field test record. | project-specific |
The fixed-piston sampler uses a piston held stationary at the base of the borehole while the sample tube is advanced by hydraulic push, creating a partial vacuum that retains the sample and prevents water entry. Piston samples typically have lower disturbance than conventional push tubes and are preferred for marine and lacustrine soft clay investigations where sample quality is paramount.


GEC 5 (Table 47) flags soils and soft rocks where conventional SPT and tube sampling give misleading results. The ones that show up most often on railroad corridors:
| Material | Sampling difficulty | Engineering concern |
|---|---|---|
| Colluvium and talus | Thin weak lenses; rock fragments prevent sampling; boulders preclude drilling | Thin weak layer and water at the colluvium/rock contact control slope stability; talus may sit at FS ≈ 1. Use test pits, trenches, and surface-wave geophysics for talus thickness. |
| Shale, claystone and other degradable rock | Rock-like in place, needs coring; drilling water starts degradation | Rockfill or cut faces degrade on wetting; slope stability decreases progressively. |
| Cemented sands | High blow counts / refusal look like dense sand; coring water may dissolve binder | Brittle; collapse if the cement is soluble; long-term strength may drop to uncemented sand. |
| Sensitive (quick) clays | Metastable structure makes undisturbed sampling difficult; may need foil or block sampler | Can fail with little or no warning. |
For these materials, plan test pits or block samples, triple-tube coring, or in-situ tests (Chapter 5.1) rather than relying on SPT and Shelby tubes.
Source: Sabatini, P. J. et al. (2002). Evaluation of Soil and Rock Properties. Geotechnical Engineering Circular No. 5, FHWA-IF-02-034 (superseded by GEC 5, Geotechnical Site Characterization, FHWA-NHI-16-072 (2017))
Total Core Recovery (TCR) is the length of core recovered expressed as a percentage of the length drilled:

| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| TCR | Length of core recovered (ft) Length of core run (ft) × 100% | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
RQD quantifies the degree of fracturing in a rock mass. It is defined as the percentage of a core run consisting of intact pieces 4 inches or longer in length:
| RQD (%) | Rock Quality |
|---|---|
| 0–25 | Very Poor |
| 25–50 | Poor |
| 50–75 | Fair |
| 75–90 | Good |
| 90–100 | Excellent |
Measure RQD on every core run and report it on the boring log alongside TCR, hardness (field estimate) and the visual rock description. Photograph all core boxes before and after the geologist's review, and submit the photos with the boring data package.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| RQD | ∑ lengths of intact core pieces ≥ 4 in | Field mapping / core logging | From core logs and outcrop mapping using the cited rating tables (RQD per ASTM D6032; joint spacing, condition, water). | see rating tables |
USBR’s field rules (after Deere) remove most of the logger-to-logger scatter in RQD:

Table 6-S1. USBR fracture density descriptors (excludes mechanical breaks)
| Code | Descriptor | Criteria |
|---|---|---|
| FD0 | Unfractured | No observed fractures |
| FD1 | Very slightly fractured | Core mostly in lengths > 3 ft |
| FD3 | Slightly fractured | Mostly 1–3 ft, few scattered lengths < 1 ft or > 3 ft |
| FD5 | Moderately fractured | Mostly 0.33–1.0 ft, most about 0.67 ft |
| FD7 | Intensely fractured | Average 0.1–0.33 ft with fragmented intervals |
| FD9 | Very intensely fractured | Mostly chips and fragments with a few short core lengths |
Even-numbered codes (FD2, FD4, FD6, FD8) are used for intervals “in between” two descriptors. Report fracture frequency (natural fractures per foot) alongside RQD; a full entry reads, for example, “Slightly fractured (FD3), core in 0.8–4.7 ft lengths, mostly 1.7 ft; 25% bedding joints / 75% joints.”
Source: U.S. Bureau of Reclamation (1998). Engineering Geology Field Manual, 2nd ed., Vol. I, Ch. 5 (Discontinuities)
Table 6-S2. Rock core drilling methods (GEC 5, Table 5(b), after Day, 1999)
| Method | Sample | Best application | Limitations |
|---|---|---|---|
| Rotary coring, conventional double tube (ASTM D2113, withdrawn 2023) | 0.9–4 in. core up to 10 ft long; standard 2.1 in. (NX-class) | Continuous core in sound rock | Core lost in fractured or variable rock; bedding and joint dip visible but not strike |
| Wire-line coring | 1.1–3.3 in. core, 5–10 ft runs | Fractured rock (less caving during core removal); deep holes with faster cycle time | Same core-loss and orientation limits |
| Triple-tube with plastic liner | 1.1–2.1 in. core encased in liner | Swelling clays, shales and soft rock that swell or slake in air | Smaller sample; more complex equipment |
For railroad cut slopes and bridge foundations in shale, specify triple-tube (split inner tube or liner) coring: shale and claystone that slake on contact with drilling water are routinely logged as “poor RQD” when the fracturing is actually drilling-induced.
Source: Sabatini, P. J. et al. (2002). Evaluation of Soil and Rock Properties. Geotechnical Engineering Circular No. 5, FHWA-IF-02-034 (superseded by GEC 5, Geotechnical Site Characterization, FHWA-NHI-16-072 (2017))

A boring for a bridge approach embankment replacement on a Class I railroad located in western Kansas passes through silty sand into medium-dense alluvial sand. The raw blow count is corrected first for energy and equipment, giving N60, and then for overburden, giving (N1)60, which is the value most correlations for sand expect.
| Variable | Value | Description |
|---|---|---|
| N | 18 blows/ft | Raw blow count at 20 ft |
| Em | 0.82 | Automatic trip hammer |
| CB | 1.00 | 4-in. hollow-stem auger hole |
| CR | 0.95 | About 23 ft of rod (20 ft plus 3 ft of stick-up) |
| CS | 1.00 | Split spoon without liner |
| γ | 120 pcf above, 122 pcf below the water table | |
| zw | 8 ft | Water table |
N60 = 23 and (N1)60 = 26, at the medium dense to dense boundary (Dr about 65 to 75%).
The automatic hammer delivers more energy than the 60% standard, so the corrected count is higher than the raw one. Sand this dense has moderate to high liquefaction resistance, but it should still be screened formally with the site’s design ground motion (Chapter 6.5).
Soft marine clay is to be sampled at 22 to 26 ft for a passenger bridge approach rehabilitation. The crew has a 3.5-in. push tube. Its area ratio says how much soil the tube displaces; the project specification says which sampler must be used.
| Variable | Value | Description |
|---|---|---|
| De | 3.50 in. | Outside diameter at the cutting shoe |
| Di | 3.375 in. | Inside diameter at the cutting shoe |
| Spec | Piston sampling required for soft clay used for undrained strength | Project specification |
AR = 7.5%, so the tube meets ASTM D1587 (withdrawn 2024). The specification still requires a fixed-piston sampler for soft clay strength samples.
Area ratio controls one kind of disturbance; the piston controls another, by holding the sample in the tube during withdrawal. Record the requirement in the pre-field plan and procure the piston sampler before mobilization.
A 10-ft HQ core run in sandstone for a bridge scour and foundation investigation on a Class I railroad located in the Appalachians. RQD counts only sound pieces at least 4 in. long; recovery counts everything that came up.
| Variable | Value | Description |
|---|---|---|
| Run | 10 ft = 120 in. | HQ core |
| Pieces | 7.0, 2.5, 9.5, 1.0, 6.5, 8.0, 0.5, 4.5, 3.0, 2.5 in. | Measured in the core box; total 45.0 in. |
RQD = 30%, poor rock; TCR = 37.5%.
Low RQD with low recovery points to highly fractured sandstone, probably a weathered or fault-adjacent zone. Have a geologist review the core box photographs and describe the fractures before foundation design proceeds. This rock is unlikely to suit end bearing without a deep socket into competent rock below.
Project: Bridge Replacement — a Class I railroad line located in Virginia Boring: B-2 Date: April 15, 2026 Driller/Rig: drilling subcontractor, track-mounted rig Drilling Method: HSA (0–42 ft), Mud Rotary (42–65 ft) Hammer Type: Automatic Trip (E_m = 0.83, measured by PDA; N₆₀ uses C_R by rod length with 3 ft of stick-up) Water Table: Encountered at 18.0 ft during drilling; stabilized at 16.5 ft after 30 minutes

| Depth (ft) | Sample | Blows (6"/6"/6") | N_raw | N₆₀ | Soil Description | Lab Tests |
|---|---|---|---|---|---|---|
| 0–2 | SS-1 | 3/4/4 | 8 | 8 | Brown medium sand, trace gravel; fill | — |
| 5–6.5 | SS-2 | 5/6/7 | 13 | 13 | Brown silty fine sand; medium dense; moist | Sieve |
| 10–11.5 | SS-3 | 8/10/12 | 22 | 26 | Gray silty sand; medium dense; moist | Sieve, Atterberg |
| 15–16.5 | ST-1 | Push | — | — | Gray-brown firm silty clay; push recovery 18 in. | Consol, UU Tri |
| 20–21.5 | SS-4 | 12/15/18 | 33 | 43 | Gray sandy gravel; dense; wet; below GWT | — |
| 25–26.5 | SS-5 | 18/22/25 | 47 | 62 | Gray sandy gravel; very dense; wet | — |
| 30–31.5 | SS-6 | 50/4" | R | — | Refusal: 50 blows for 4 in. of penetration | — |
| 35–36.5 | CS-1 | Core run | TCR=75% | — | Gray medium sandstone; RQD=55%; moderately fractured | Unconf. Comp. |
| 40–41.5 | CS-2 | Core run | TCR=92% | — | Gray-brown sandstone; RQD=88%; slightly fractured | — |
SS = Split Spoon; ST = Shelby Tube; CS = Core Sample; R = Refusal; GWT = Groundwater Table; Consol = Consolidation; UU Tri = Unconsolidated-Undrained Triaxial; Unconf. Comp. = Unconfined Compression
Figure 4.1-1 Placeholder: Full-scale boring log in a typical railroad format, showing graphical soil profile, blow count vs. depth plot, water level indicators, and sample retention summary. [Insert CAD or boring log software output here.]
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
| Sample | Depth (ft) | Soil Description | w_n (%) | LL (%) | PL (%) | PI | γ_d (pcf) | USCS | Lab Tests Completed |
|---|---|---|---|---|---|---|---|---|---|
| SS-3 | 10–11.5 | Silty fine sand | 14.2 | 22 | 18 | 4 | 104 | SC-SM | Sieve, Atterberg |
| ST-1 | 15–16.5 | Silty clay | 38.7 | 48 | 24 | 24 | 82 | CL | Consol, UU Tri |
| SS-4 | 20–21.5 | Sandy gravel | 8.1 | NP | NP | NP | 118 | GW-GM | Sieve |
| CS-1 | 35–36.5 | Sandstone core | — | — | — | — | — | Rock | Unconf. Comp. |




Hunt describes two sampling methods for soils that thin-walled tubes handle poorly:

Source: Hunt, R. E. (2005). Geotechnical Investigation Methods: A Field Guide for Geotechnical Engineers. CRC Press
Haidar gives the basic duration relation used in CPM scheduling:
Activity duration = Work quantity ÷ Production rate (Haidar Eq. 3.1)
The time unit (hours, shifts, days) may be anything, provided it is used consistently throughout the schedule. He notes that the estimates need not be exact. When every duration is reasonable, over- and under-estimates tend to offset, and spending too much effort refining individual durations makes the schedule harder to build without making it better. He lists the factors that control how accurate an estimate will be: number of projects, complexity, design duration, construction method, resource availability, work quantity, labor and equipment productivity, quality of field management, geography and site conditions, and concurrent activities. He recommends getting each estimate from the person who will manage the work.
On logic, Haidar recognizes three relationships: predecessor, successor, and concurrent (independent). Concurrent means only that neither activity depends on the other, not that they must run at the same time. There is usually more than one correct sequence, and choosing among them requires knowing how the work is actually built.
For railroad work: split the drilling quantity by method, because production differs widely. Soil drilling with SPT intervals, Shelby tube sampling, rock coring and in-hole testing each need their own quantity and rate. Production rates should come from the firm’s own driller records for similar ground and access, not from catalog figures. Express the rate per effective hour under track protection. As an illustration only: 480 ft of soil drilling at 30 ft per effective hour is 16 effective hours. If a track window yields about 5 effective hours after protection setup, moves between holes and clearing, the work needs 4 windows. Add separate activities for rock coring, grouting or backfill, and the move-in and move-out of each site. Off-track work, such as CPT soundings from an access road or borings at the embankment toe, is often concurrent with on-track borings and can fill time when windows are cancelled. Record actual footage and hours each shift so that the next program’s production rates are better than this one’s.
Source: Haidar, A. D. (2016). Construction Program Management – Decision Making and Optimization Techniques. Cham, Switzerland: Springer International Publishing, pp. 64–66. Summarized and paraphrased. Full reference under Supplemental References.
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
Checklist · Part V · Subsurface Exploration
McKinnon (2012) builds on the accident ratio: for every serious injury there are larger numbers of minor injuries, more property-damage events, many near misses, and beneath those a broad base of high-risk acts and conditions. Heinrich (1931) reported 1 serious injury : 29 minor injuries : 300 no-injury accidents. Bird and Germain (1966), from nearly 2 million reported accidents, gave 1 serious : 10 minor : 30 property damage : 600 near misses. A British Tye-Pearson study gave 1 : 3 : 50 first aid : 80 damage : 400 near misses, and the U.K. HSE (1993) gave 1 : 11 : 441. McKinnon stresses that the exact numbers matter less than the conclusion: near misses are far more frequent than injuries, and often the only difference between the two is luck.
Because near misses share the same causes as accidents, they are free warnings. McKinnon’s system (recognition, reporting, risk ranking, investigation and remedy) does not investigate every report. Each near miss is ranked on a simple matrix of potential loss severity versus probability of recurrence. Events in the high–high cell are investigated as rigorously as a serious injury, as are high–medium-high and medium-high–medium-high events; lower-ranked reports are tracked and addressed once the high-potential ones are under control. He cites the “critical few” principle: perhaps 20% of near misses hold 80% of the loss potential. A no-blame policy is essential, since programs fail when reporting leads to discipline. He notes that rail has adopted this model through CIRAS, a confidential reporting system used in Britain.
For railroad work: Add near-miss reporting to the borings and sampling field checklist. Drilling on the right-of-way combines rotating equipment and overhead or buried utilities with train movements and roadway worker protection, so close calls such as a rig mast near the foul envelope, an unannounced train during setup, or a mislocated utility should be recorded on the daily report, ranked, and discussed at the next job briefing. The railroad’s own close-call program (for example FRA’s C3RS on participating carriers) may also apply; follow the client’s reporting rules.
Source: McKinnon, R. C. (2012). Safety Management: Near Miss Identification, Recognition, and Investigation. Boca Raton, FL: CRC Press (Taylor & Francis), pp. 12–17, 24–26. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.
Pre-Mobilization
During Drilling
Post-Field
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
| Topic | See Chapter |
|---|---|
| Boring location and depth planning | Chapter 3.9 |
| SPT-based classification | Chapter 2.2 |
| In situ testing (CPT, VST, PMT) | Chapter 5.1 |
| Groundwater measurements during drilling | Chapter 2.8 |
| Foundation bearing capacity from SPT | Chapter 6.1 |
| Settlement analysis from consolidation samples | Chapter 6.2 |
| Liquefaction screening using (N₁)₆₀ | Chapter 6.5 |
| Laboratory testing of recovered samples | Chapter 5.2 |
| Boring log reporting and submittal | Chapter 8.4 |
A boring for a railroad bridge abutment on a Class I railroad located in Nebraska was drilled with a donut hammer, although the owner (assumed) requires automatic hammers on bridge borings. At 35 ft the raw blow count in sand is 24. The engineer must correct the blow count, describe the sand, and decide what to do about the hammer requirement before the data are used for abutment design.
| Variable | Value | Description |
|---|---|---|
| N | 24 blows/ft at 35 ft | Raw blow count |
| Em | 0.45 | Donut hammer |
| CB, CR, CS | 1.05, 1.00, 1.00 | 5-in. hole; 35 ft of rod; no liner |
| γ | 118 pcf to 12 ft; 125 pcf below | Water table at 12 ft |
| Owner rule (assumed) | Automatic hammers on bridge borings |
(a) N60 = 19. (b) (N1)60 = 16. (c) Medium dense. (d) Report with a data-quality caveat, notify the railroad, and redrill borings that control design with a calibrated automatic hammer.
Do not scale the donut-hammer count up as if it had been driven with an automatic hammer: an automatic hammer in the same sand would have given about 13 blows and the same N60. Donut-hammer energy is highly variable and seldom measured, so the assumed 0.45 carries a large uncertainty.
On a passenger corridor project, a Shelby tube was pushed 18 in. into soft organic clay beneath a track embankment and came back with 14.5 in. of sample. The specification calls for piston sampling in soft clay. The field engineer must check the tube geometry and recovery and decide whether the sample can go to the laboratory for strength testing.
A Shelby tube in soft organic clay on a passenger corridor project. Recovery as well as area ratio says whether the sample is fit for strength testing.
| Variable | Value | Description |
|---|---|---|
| De, Di | 3.0 in.; 2.875 in. | At the cutting shoe |
| Push, recovery | 18 in.; 14.5 in. | |
| Spec | Piston sampling for soft clay |
(a) AR = 8.9%, acceptable. (b) SRR = 81%, which suggests sample loss or compression near the base. (c) Keep the sample for water content and index tests and resample the interval with a fixed-piston sampler.
Low recovery in soft organic clay usually means soft material piped past the valve or gas-rich clay compressed during withdrawal. Record the deviation and the corrective action in the field log.
A short-line railroad located in Missouri is replacing a timber trestle and wants to know whether a pile or shaft can end-bear on limestone. The first 10-ft HQ core run in weathered limestone recovered ten pieces totaling 40.5 in. The engineer must compute the rock quality from the core and recommend whether end bearing at this level is reasonable.
| Variable | Value | Description |
|---|---|---|
| Run | 120 in. | |
| Pieces | 2.5, 5.0, 0.5, 8.5, 1.0, 6.0, 3.0, 7.5, 2.0, 4.5 in. | Total recovered 40.5 in. |
(a) RQD = 26%, TCR = 34%. (b) Poor rock. (c) End bearing here risks punching into voids or soft infill.
Advance the boring through the weathered zone, watch for loss of drilling fluid and rod drops that mark karst, and redesign for drilled shafts socketed into competent rock if it is found at an acceptable depth. Bearing resistance on fractured rock (RQD 25 to 50%) is much lower than on competent rock (Chapter 6.1).
A track geometry deviation appeared overnight on a Class I railroad main line in karst country, and a sinkhole is suspected. A 10-mph slow order is in place and the railroad wants borings within 48 hours. The engineer must choose the drilling method, set the minimum boring program, and agree the documentation needed for an emergency investigation.
| Variable | Value | Description |
|---|---|---|
| Symptom | Sudden surface and cross-level deviation | Overnight |
| Suspected cause | Sinkhole or soft ground collapse | |
| Timeline | 48 hours |
No equation is needed; the answer follows from the criteria listed under Given.
(a) Hollow-stem auger with mud rotary backup. (b) Agree the reporting schedule and safety notifications with the railroad before drilling. (c) Three borings, at the deviation and 25 ft either side, to 30 ft or 10 ft into competent material.
Air pressure in a hole beside a marginal cavity can trigger the collapse the investigation is trying to find, which is why air rotary is ruled out. Deliver preliminary logs and a geohazard assessment by the end of day 2.
A Class I railroad located on the Assiniboine River in Manitoba is replacing a river bridge. Dolomite is expected at about 50 ft and the specification calls for HQ core. The first 10-ft run in rock recovered eight pieces totaling 67 in. The engineer must report the core size, compute the rock quality, and say how the data should be presented and tested for the foundation design.
| Variable | Value | Description |
|---|---|---|
| Core | HQ | Specification |
| Run | 120 in. | First run in dolomite |
| Pieces | 11.0, 8.0, 14.0, 3.5, 9.0, 5.5, 8.5, 7.5 in. | Total recovered 67.0 in. |
(a) 2.50 in. (b) RQD = 53% (fair), TCR = 56%. (c) Run-by-run columns with an RQD chart and photo references. (d) At least three UCS specimens per rock unit.
RQD close to TCR means nearly all recovered core is sound; the concern is the 44% that did not come up, which may be soft seams, solution features or drilling problems. Review the drilling record before interpreting the loss. For dolomite with qu of 5,000 to 20,000 psi, bearing rarely governs; socket geometry and uplift usually do.
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
Field case studies by Burt G. Look, from Earthworks: Theory to Practice – Design and Construction (CRC Press/Balkema, 2023), chosen for this chapter’s topics. Each is summarized from the book with its key figures and a closing note on railroad application added by the authors of this manual. Credit for the case material belongs to Look; see item S12 under Supplemental References.
Related section: 4.1.2 Drilling Method Selection
During construction a project manager ordered extra probe holes and concluded that a different, softer material had been found. It had not. The probes were drilled with a tungsten-carbide (TC) bit auger, while the design borings had been cored. Low- to medium-strength basalt with natural fractures at roughly 4 in spacing was crushed by the heavy rig, and the cuttings came up as “soil” graded through the No. 8, No. 30 and No. 40 sieves. Side by side with the adjacent core, the probe hole produced a new “soil” stratigraphy that conflicted with the design rock profile.
Look notes two related habits. Highly weathered rock is often described as soil in any case, and the material just above the start of coring is usually logged conservatively as a weaker grade because the SPT or wash sample there is less informative than core. Visual strength classification, point load index and other rock testing should be done on the core.
For railroad work: when probe holes, auger refusals or contractor holes are used to check rock levels for cuts, culvert footings or pile toes, record the drilling method on every log and compare like with like. A change of drilling technique is not a change of material.

Source: Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press/Balkema. Case study §2.6, pp. 68–70. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
Related section: 4.1.3 Standard Penetration Test (SPT) — Procedure and Corrections
An SPT N-value is reported as “factual”, but only whole blows can be counted, and the 6 in increments are judged against a chalk mark 0.2–0.39 in. wide in the under-7-second window between blows. That reading error alone is 7%–13% per increment. Digitally measured increments with a 6 in. target averaged 5.8 in. with a standard deviation of 0.63 in. (range 4.3–7.5 in.), a coefficient of variation of 11%–15%. The two test increments partly compensate; the error carried over from the seating drive matters more.
On a large investigation with three rigs, hammer energy and rod length were measured on Rigs 1 and 2. Rig 1 needed a correction factor of about 1.5, so its design strength and modulus rose by 50%. Rig 2 needed almost none. Rig 3 was never measured and was assumed to be 1.0. Across the 1,120 tests, 18% of N-values below 50 changed density class once corrected.
Look’s recommendation is that every rig carry a current energy certificate, as a laboratory carries accreditation, so the cost is shared across projects and firms that measure energy are not undercut by those that do not.
Table 6-LK1. Change in density class after energy correction, 1,120 SPTs at one site (after Look 2023, Table 3.1.19)
| Density class | Original N | Energy-corrected N60 | % changed |
|---|---|---|---|
| Very loose (< 4) | 45 | 43 | 4% |
| Loose (< 10) | 179 | 162 | 11% |
| Medium dense (< 30) | 446 | 354 | 25% |
| Dense (< 50) | 77 | 174 | 18% |
| Very dense (≥ 50), excl. rock | 50 | 64 | n/a |
For railroad work: ask for the hammer energy ratio with every boring subcontract and record the rig on each log. Liquefaction screening, pile capacity and bearing checks on railroad bridges all use corrected N60; an uncorrected value from an unmeasured rig is not a design value.

Source: Look, B. G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press/Balkema. Case study §6.12, pp. 194–196. Summarized and paraphrased; figures reproduced for internal reference. Full reference under Supplemental References.
New sidings, second main tracks and grade raises run for miles along an existing embankment, and the boring program has to sample the existing roadbed, the embankment and the cut slopes as well as the ground beneath. AREMA Chapter 1, Part 1, notes that new construction next to existing track may need only a few widely spaced borings unless problem areas show up, while creeping failures under existing track need exploration deep enough to intercept the failure plane, supplemented by trenches, test pits, inclinometers, piezometers and CPT. A Class I railroad's public projects geotechnical requirements turn this into a pattern, used by the calculator.
| Location | Borings | Depth |
|---|---|---|
| Each quarter mile, representing the prevailing cut or fill | Top of existing grade (between edge of ballast and shoulder), midslope, ditch line just off the toe | To stable track and embankment subgrade or foundation |
| Cut sections | Add one boring at the top of the cut slope, near the right-of-way line | Cut height plus 5 ft below the proposed ditch flowline; bulk samples for classification and modified Proctor |
| Culverts to be extended | One at each end | For sub-excavation and stabilization advice to limit differential settlement |
| Bridges, walls and unique structures | As the structure requires | Per structure design |
The report should also give stripping depth, sub-excavation, benching, compaction, ditch depth and grade, subballast thickness by the AREMA method, and stable fore and back slopes from stability analysis.
| Result | Value |
|---|---|
| Boring series | 13 |
| Total borings | 56 |
| Total footage | 1,280 ft |
| Average depth | 22.9 ft |
Borings on top of grade sit within a few feet of the live track, so each needs flagging and track time; in this example 13 of the 56 borings are of that kind. The logs should record ballast, subballast and fouling thicknesses, which feed Chapters 2.1 and 6.4. A geotechnical engineer should walk the corridor first and move or add borings where the reconnaissance shows soft ground, seepage or slope movement.
Open the corridor boring calculator →
Quarter-mile boring series, top-of-cut borrow borings, culvert-end and structure borings, with counts and footage.
These documents are in the reference library. The summaries above are paraphrased; equations and tabulated limits are standard or published values. Individual railroads are not named.
A strength or consolidation test is only as good as the sample. The Corps of Engineers' Geotechnical Investigations manual (EM 1110-1-1804, Appendix F) summarizes Hvorslev's classic criteria for sampler design. The area ratio, the volume of soil displaced by the cutting shoe relative to the sample, may be the most important single factor. Inside clearance lets the sample enter without wall friction. Outside clearance should be small, or wall friction can cause a bearing failure below the shoe. Sample length should be limited, the tube pushed in one fast, continuous stroke rather than driven, and recovery recorded. The manual also lists the usual causes of poor recovery: pressure above the sample from poor venting, suction below the tube as it is pulled, and failure to shear the sample off at the shoe.
Equation 4.1-1. Hvorslev's sampler ratios (EM 1110-1-1804, Eqs. 2-1 to 2-3)
| Item | Recommendation |
|---|---|
| Area ratio Ca | Preferably below 10 to 15%. ISSMFE (1966) accepted 5 to 20% with the edge taper reduced from 15° to 9° |
| Inside clearance Ci | 0 to 1% for very short samples; 0.5 to 3% for medium length; 0.75 to 1.5% for L/D of 6 to 8 |
| Outside clearance Co | Under 2 to 3% in cohesive soil; zero in cohesionless soil |
| Length to diameter | 5 to 10 in cohesionless soil; 10 to 20 in cohesive soil |
| Advance | Push with a fast, continuous, uniform motion; driving causes the greatest disturbance |
| Recovery | Vent the tube, rotate one or two turns to shear the sample, or use a piston sampler |
A standard 3 in. thin-wall tube of 16 gauge steel has an area ratio of 9.3% and a 2 in. tube of 18 gauge 10.6%. Both are within Hvorslev's preferred range. The standard split spoon used for the SPT has an area ratio of 111.6%, so its samples are disturbed and suitable only for index tests. A 24 in. push that recovers 21 in. gives 88% recovery and a warning to find out why. The nominal tubes show zero inside clearance; tubes with a rolled or swaged cutting edge give the 0.75 to 1.5% Hvorslev suggests, so measure the actual shoe.
Open the sampler disturbance calculator →
Hvorslev's area ratio, inside and outside clearance, length-to-diameter ratio and recovery, compared with the recommended limits, with common samplers for comparison.
These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.
Where borings for a bridge, wall or rock cut reach rock, two numbers from each core run carry most of the information: the recovery ratio, and the rock quality designation (RQD). RQD is the total length of pieces 4 in. or longer divided by the length cored. Das's Principles of Geotechnical Engineering defines both and gives Deere's descriptions from Excellent to Very poor. Look's Handbook of Geotechnical Investigation and Design Tables carries RQD into first estimates of rock mass strength and allowable bearing pressure, and into a check from joint counts on exposures. The Corps of Engineers' EM 1110-1-1804 asks for RQD on every run, with core loss shown on the log at its most likely depth. It points out that the weak, fractured zones where recovery is poorest are usually the critical ones for foundations and stability, and that larger core barrels improve recovery in them.
| RQD (%) | Quality (Deere) | Allowable bearing (Peck, Hansen and Thorburn), MPa (ksf) | Rock mass (Kulhawy and Goodman) |
|---|---|---|---|
| 90–100 | Excellent | 20–30 (418–627) | Design compressive strength 0.33–0.8qu; c = 0.1qu; φ = 30–60° (RQD over 70) |
| 75–90 | Good | 12–20 (251–418) | |
| 50–75 | Fair | 6–12 (125–251) | Design compressive strength 0.33qu; c = 0.1qu; φ = 30° (RQD up to 70) |
| 25–50 | Poor | 3–6 (63–125) | |
| 0–25 | Very poor | 1–3 (21–63) |
Bearing values are limited to the uniaxial strength of the rock or the allowable stress of the concrete; Look notes the RQD method is common but not suitable for detailed design. Sources: Das Table 18.7; Look Tables 9.13 and 22.1.
| Designation | Bit outside diameter, in. (mm) | Core diameter, in. (mm) |
|---|---|---|
| EX | 1-7/16 (36.5) | 7/8 (22.2) |
| AX | 1-7/8 (47.6) | 1-1/8 (28.6) |
| BX | 2-5/16 (58.7) | 1-5/8 (41.3) |
| NX | 2-15/16 (74.6) | 2-1/8 (54.0) |
Three 5 ft runs in a bedded limestone recover 57.5, 57 and 37.5 in. of core. The pieces 4 in. or longer total 47, 57 and 23.5 in., so the runs have RQDs of 78%, 95% and 39%. Overall the RQD is 71% and the recovery 84%, but the third run (39%) is a poor zone that a single average would hide. The first-approximation allowable bearing for the average is 125 to 251 ksf. A footing or pile tip should be designed on the weakest zone it will bear on, and that zone should be checked with laboratory strength tests.
Open the core RQD calculator →
Recovery and RQD run by run and overall, Deere's quality description, first-approximation rock mass properties and allowable bearing pressure, and an RQD check from a volumetric joint count.
These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.
RQD says how broken the rock is, but not which way the breaks run. For a rock cut, tunnel portal or rock-socketed foundation, joint orientation decides whether blocks can slide or topple out of the face (kinematic analysis, Chapter 2.7 and Chapter 6.3). Joint orientation can only be measured from core if the core is oriented.
Oriented coring. A knife in the core barrel cuts a continuous scribe line along the core. Before coring, the driller sets the knife on a known bearing, usually north, with a compass. Proprietary orientation tools do the same with a reference mark. Because the core does not rotate in the barrel, the scribe line stays a fixed reference. For each joint, the logger draws the horizontal line across the joint surface and measures the clockwise angle from the reference line to it: that is the strike. The dip is the angle between the joint surface and the horizontal, measured down the steepest line.
Notation. With the right-hand rule, place the right hand palm down on the joint with the fingers pointing down-dip; the thumb gives the strike direction, so the dip direction is strike + 90°. The same joint can be written three ways, and they are easily confused:
State the convention on every log and in every table of joint data.
Poles. Each joint plane can be represented by its pole, the line normal to the plane, plotted on the lower hemisphere of a stereonet. The pole trends opposite the dip direction (dip direction ± 180°) and plunges at 90° minus the dip. Clusters of poles define the joint sets used in kinematic analysis.
Apparent dip. On a section that is not parallel to the dip direction, such as a cut face or a cross section drawn square to the track, a joint appears flatter than its true dip:
tan α = tan δ × cos β
where α = apparent dip, δ = true dip and β = angle between the section and the dip direction.
For railroad work: Specify oriented core in borings for new or widened rock cuts, portals and high rock-socketed foundations, where surface mapping cannot reach the rock. Set acoustic or optical televiewer logging as an alternative in holes that stay open. Have the driller record the reference bearing and the borehole inclination for every run. Core from an inclined hole must be rotated back to true orientation before plotting.
Source: Rajapakse, R. (2016). Geotechnical Engineering Calculations and Rules of Thumb, 2nd ed. Oxford: Butterworth-Heinemann, Ch. 32 (dip angle and strike; oriented rock coring; concept of the pole). Summarized and paraphrased; the alternative notations, apparent-dip relation and recommendations for railroad work are standard practice added by the authors of this manual.
A Class I railroad located in Pennsylvania plans to widen a sandstone cut on the north side of its main line. The new face will dip 70° toward 170°. An oriented NX core from a vertical boring behind the face shows a persistent joint set. The logger recorded it as 40/070 in dip/strike notation, using the right-hand rule. Laboratory tilt tests give a joint friction angle of 30°. The engineer must convert the joint to dip direction and pole, find its apparent dip on a cross section square to the track, and make a first check of whether planar sliding out of the new face is possible.
| Variable | Value | Description |
|---|---|---|
| Joint | 40/070 | Dip 40°, strike 070° (right-hand rule), from oriented core in a vertical hole |
| Face | 70° toward 170° | Planned cut face |
| φj | 30° | Joint friction angle (tilt test) |
| Section | Bearing 170° | Cross section square to the track |
(a) Dip direction 160°; the joint is 070/40 in strike/dip and 40/160 in dip/dip-direction form. (b) The pole trends 340° and plunges 50°. (c) On the cross section square to the track it dips 39.6°. (d) It strikes nearly parallel to the face, daylights in it, and dips more steeply than its friction angle, so planar sliding toward the track is kinematically possible.
A single joint is only a first check. Plot all the oriented-core and face-mapping data on a stereonet, define the sets, and run the full kinematic and limit-equilibrium analysis (Chapters 2.7 and 6.3), including water pressure in the joints and train vibration. Options for this set are a flatter face (at or below about 40°, which needs much more excavation), rock bolts or dowels across the set, or a rockfall catchment sized for the blocks it can release. Record on the boring logs that the joint data are in dip/strike notation. A designer who reads 40/070 as dip/dip direction would put the joint dipping toward 070°, about 100° away from the face, and conclude wrongly that it cannot slide out.
Authors: Daniel P. Colwell and Mario Ruel. This chapter was written and compiled by Daniel P. Colwell and Mario Ruel for Railway Ground Hazard Risk Management.
Technical content is drawn from the published sources below, and credit for that material belongs to their authors and publishers. Tables, equations and figures taken from a specific source are also cited where they appear.
File locations for these documents are listed under Supplemental References.
Material in the green “Supplemental reference” boxes throughout this chapter was added from the following documents in the LEVI geotechnical library. Text is summarized or paraphrased; tables are reproduced with their original source noted; figures are reproduced from the cited document for internal reference use. Consult the original document before relying on a value for design. The Case Studies section summarizes case studies from item S12 by Burt G. Look; its figures are reproduced from the book for internal reference use, and the closing “For railroad work” note in each case study is added by the authors of this manual. Blocks tagged “Project management” summarize methods, examples and figures from the project-management, estimating and construction-management books listed here, applied to railroad work; the closing “For railroad work” note in each block is added by the authors of this manual.