In situ testing provides continuous or near-continuous soil and rock characterization without the inherent sample disturbance associated with laboratory testing.
The four examples reduce four common in situ tests to design values: CPTu strength in soft clay, vane strength with Bjerrum’s correction, site class from MASW, and subgrade CBR and modulus from a DCP test. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution.
Example 5.1-1: CPTu Characterization of a Soft Clay
A CPTu sounding supports an embankment widening on a Class I railroad located near Savannah, Georgia. In soft clay the pore pressure acting behind the cone tip is a large share of the measured resistance, so the tip value must be corrected before anything is computed from it.
Given and required for Example 5.1-1.
Given
Variable
Value
Description
qc
4.20 tsf
Measured tip resistance at 22 ft
u2
1.80 tsf
Pore pressure at the shoulder
a
0.80
Net area ratio
γ
108 pcf
Soil unit weight
zw
4 ft
Water table
Nkt
14
Cone factor
Required
Corrected tip resistance qt
Undrained strength su
Pore pressure ratio Bq
Equations
Eq. 5.1-1: qt = qc + u2(1 − a) — corrected tip resistance
Spot check: su/σ′v = 0.241/0.626 = 0.38, in the usual range for a normally to lightly overconsolidated clay.
↓
Solution
qt = 4.56 tsf; su = 482 psf; Bq = 0.37.
Solution
qt = 4.56 tsf, su ≈ 480 psf and Bq = 0.37: a soft, normally to lightly overconsolidated clay.
The correction added 0.36 tsf, about 8% of qt but 11% of the net resistance that su comes from; skipping it would overstate the strength. The value goes into the embankment stability analysis (Chapter 6.3). Nkt should be calibrated against vane or laboratory tests on the same clay before design.
Example 5.1-2: Vane Shear Test With Bjerrum’s Correction
Vane tests near the south shore of Lake Erie support an embankment stability check in soft lacustrine clay. The peak and remolded torques give strength and sensitivity; Bjerrum’s correction converts the vane strength to the strength mobilized in an embankment failure.
Eq. 5.1-8: St = su,peak / su,remolded — sensitivity
Eq. 5.1-7: su,design = μ su,peak — Bjerrum; μ = 0.85 at PI 40, 0.75 at PI 60, 0.65 at PI 80
Steps
Step 1 · Vane constant
7π × 0.187³ = 7π × 0.00654
0.1438 ft³
↓
Step 2 · Peak and remolded (Eq. 5.1-6)
6 × 12.4 / 0.1438; 6 × 3.1 / 0.1438
517 psf and 129 psf
↓
Step 3 · St (Eq. 5.1-8)
517 / 129
St = 4.0: medium sensitivity, below 8
↓
Step 4 · μ at PI 55% and design su (Eq. 5.1-7)
0.75 + (5/20)(0.10) = 0.78; 0.78 × 517
su,design = 402 psf
Spot check: 517 / 402 = 1.29: the raw vane overstates the strength by about 29%.
↓
Solution
su,design = 402 psf; St = 4.0.
Solution
Peak 517 psf, remolded 129 psf, St = 4.0, and design su = 402 psf.
Using the uncorrected vane strength would overstate the embankment’s stability by nearly 30%. Apply the Bjerrum correction to all vane data used in embankment design. The sensitivity does not reach the enhanced seismic review threshold, but it is high enough that the clay will lose most of its strength if disturbed.
Example 5.1-3: Site Class From an MASW Profile
An MASW survey for a new intermodal facility on a Class I railroad located in the Mid-Continent gives a layered shear wave velocity profile. The site class comes from the time-averaged velocity over the top 100 ft, not the simple average.
Given and required for Example 5.1-3.
Given
Variable
Value
Description
Layers
12 ft at 480; 28 ft at 920; 35 ft at 1,650; 25 ft at 3,200 ft/s
Spot check: A simple average of the four velocities would give 1,560 ft/s and Class C; the time average gives the soft layers their proper weight.
↓
Step 3 · Gmax (Eq. 2)
(120/32.2) × 480² = 3.727 × 230,400
858,900 psf ≈ 429 tsf
↓
Solution
Vs,30 = 1,185 ft/s, Site Class D.
Solution
Vs,30 = 1,185 ft/s, Site Class D; Gmax of the upper layer ≈ 429 tsf.
Class D calls for the site amplification factors Fa and Fv in seismic design (AREMA Chapter 9; AASHTO). Being within 2% of the Class C boundary, the result is sensitive to the soft top layer; a second MASW line or a downhole test would confirm it before the class is fixed. Gmax is the small-strain stiffness; the operating stiffness under heavy axle loads is lower.
Example 5.1-4: Subgrade Strength from a DCP Test in a Crib Dig
A section of main track on a Class I railroad located in the Ohio Valley needs surfacing every few months, and the ballast at the shoulder is stained with clay. During a track window the ballast is removed from one crib and a DCP is driven through the subballast into the subgrade. The example shows how a DCP record becomes the CBR and modulus values that the trackbed design uses, and why the subgrade soil type must be known before the correlation is chosen.
Given
Variable
Value
Description
Layer 1
8 in. in 16 blows
Subballast, well-graded sand and gravel
Layer 2
12 in. in 8 blows
Subgrade, lean clay (CL), from a hand-auger sample
Mr,design
6,000 psi
Subgrade modulus assumed in the original granular layer design
Required
DCP index of each layer
CBR of each layer
Resilient modulus of each layer, and whether the subgrade meets the design value
Equations
Eq. 5.1-20: DPI = penetration / blows — in./blow
Eq. 5.1-21: CBR = 7.80 / DPI1.12 (IS-26) — ASTM D6951 general correlation (written for DPI in in./blow); all soils except CH, and CL with CBR below 10
Eq. 5.1-22: CBR = 5.35 / DPI2 (IS-27) — ASTM D6951 correlation for CL with CBR below 10 (DPI in in./blow)
The subballast is adequate (CBR about 17); the subgrade is not (CBR about 2.4, Mr about 4,500 psi against 6,000 psi assumed).
The test points to the subgrade, not the ballast, as the cause of the repeated surfacing. That changes the fix: cleaning or replacing ballast would not last. The low modulus goes into the granular layer thickness check (Chapter 2.1, Section 2.1.17) to find the subballast thickness that keeps subgrade stress within its allowable value, and into the track substructure assessment (Chapter 2.3). One crib is one point: repeat the test at several cribs, chosen from GPR or track geometry records, and check the CBR of the clay in the laboratory before a design is fixed. Because CBR here is a correlated value, record it as such in the risk rating.
Empirical equation note · this example
Equations 5.1-21 to 5.1-23 are correlations. The DCP–CBR equations are converted from ASTM D6951 (which uses mm/blow) to in./blow; the modulus equation is from the AASHTO mechanistic-empirical pavement design guide. Use them for soils within their range and confirm with laboratory CBR or resilient modulus tests.
Empirical equation note · this section
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
IS-12 Corrected cone resistanceqₜUse: All piezocone (CPTu) soundings; essential in soft clays and silts. Limits: Correction negligible in clean sands; critical in soft fine-grained soils. Requires u2 filter position.
IS-14 Undrained shear strength from CPTSᵤUse: Fine-grained soils penetrated undrained (Ic > ~2.6). Limits: Nkt depends on reference test (vane, CIUC, DSS) and plasticity; calibrate locally. Use Nkt toward upper end for conservative Su.