↑ Parent Menu⌂ Main Menu
← Chapter 5.1 In Situ Testing
GHRM
Railway Ground Hazard Risk Management · 5.0 · Testing
Sections · click a car to open it

5.1.3 Vane Shear Test (VST)

In situ testing provides continuous or near-continuous soil and rock characterization without the inherent sample disturbance associated with laboratory testing.
Authors: Daniel P. Colwell and Mario Ruel
5.1.3 Vane Shear Test (VST)
At a glance. Provides: Peak and remolded su of soft clay, and sensitivity. Used for: Embankment stability and staged construction in soft clay, Nkt calibration, and screening of sensitive clays. Catalogue entry
5.1.3.1 Test Procedure

The field vane shear test (ASTM D2573) measures peak and remolded undrained shear strength of soft to firm cohesive soils. A four-bladed vane with H/D = 2 is pushed to the test depth and rotated at about 6°/minute. ASTM D2573 lists the standard vane sizes; the examples in this chapter use a 2.24-in. diameter × 4.49-in. vane, so check the actual vane size before using the equations below. The test is suited to soft clays with s_u < 1.0 tsf. It is inappropriate in sands, gravels, or stiff clays.

Specific applications by railroad client:

  • A Class I railroad — soft Atlantic Coastal Plain clays; VST is commonly specified for embankment stability assessments on sensitive clays.
  • High-speed passenger corridor — marine clays in the Baltimore-Philadelphia segment; VST combined with CPTu.
  • A Class I railroad — Leda (quick) clays in the St. Lawrence Lowlands require VST as a sensitivity check; this manual treats S_t > 8 as a trigger for slope stability re-analysis.
  • Short-line Gulf Coast subsidiaries — Mississippi Delta and Louisiana alluvial clays frequently exhibit s_u < 0.25 tsf; VST is the primary strength measurement tool in these areas.
5.1.3.2 Peak Undrained Shear Strength from Torque

No additional content.

Equation 5.1-6 — Peak Undrained Shear Strength:

For H/D = 2 (standard vane):

s_u (peak) = T_peak / [π × D³ × (H/(2D) + 1/6)]

Where:

  • T_peak = peak torque (lb·ft)
  • D = vane diameter (ft); example vane D = 2.24 in. = 0.187 ft
  • H = vane height (ft); example vane H = 4.49 in. = 0.374 ft

Substituting H/D = 2:

s_u (peak) = T_peak / [π × D³ × (1 + 1/6)]

= T_peak / [π × D³ × 7/6]

= 6 × T_peak / (7 × π × D³)

Converting result from lb/ft² to tsf: divide by 2,000.

Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
su (peak)undrained shear strength = T_peak / [π × D³ × (H/(2D) + 1/6)]Lab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.soft 250–500, stiff 1,000–2,000 psf · by USCS group
Tpeakpeak torque (lb·ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Dvane diameter (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Hvane height (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
5.1.3.3 Bjerrum Correction for Anisotropy and Strain Rate

Field vane s_u overestimates design undrained strength in plastic clays because the test is faster than field loading rates and the failure plane is not optimally oriented. The Bjerrum (1972) correction factor μ is applied:

Equation 5.1-7 — Corrected Design s_u:

s_u (design) = μ × s_u (field vane)

Where μ is a function of plasticity index (PI):

PI (%)μ (Bjerrum 1972)
101.00
201.00
400.85
600.75
800.65
100+0.60

For Class I railroad embankment stability analyses on Atlantic Coastal Plain soft clays (typical PI = 40–65%), μ = 0.75–0.85 is standard practice.

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
su (design)undrained shear strength = μ × s_u (field vane)Lab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.soft 250–500, stiff 1,000–2,000 psf · by USCS group
PIplasticity indexLab testPI = LL − PL from Atterberg limits (ASTM D4318).CL 7–30, CH 25–80 · by USCS group
5.1.3.4 Sensitivity

No additional content.

Equation 5.1-8 — Sensitivity:

S_t = s_u (peak) / s_u (remolded)

Clays with S_t > 8 are extra-sensitive (S_t > 16 is quick) and call for a project-level risk assessment and a slope stability analysis under seismic loading (Chapters 6.3 and 6.5).

Inputs: where each value comes from (1)
SymbolWhat it isComes fromHow to get itTypical range
suundrained shear strengthLab or field testLab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening.soft 250–500, stiff 1,000–2,000 psf · by USCS group
← Previous · 4.0 Subsurface Exploration Chapter 4.1 — Borings and Sampling
Next · 5.0 Testing → Chapter 5.2 — Laboratory Testing Program