5.1.8 Method Comparison and Selection Guide

In situ testing provides continuous or near-continuous soil and rock characterization without the inherent sample disturbance associated with laboratory testing.
Authors: Daniel P. Colwell and Mario Ruel
5.1.8 Method Comparison and Selection Guide
MethodPrimary OutputBest Suited SoilsRailroad Application
CPT / CPTuq_c, f_s, u₂Sands to soft claysLiquefaction screening; settlement (high-speed passenger corridor, a Class I railroad)
VSTs_u, S_tSoft to medium claysEmbankment stability; quick clay
PMTE_PMT, p_LAll soils; rock (SBP)Foundation modulus; stiff interbedded soils
DMTI_D, K_D, M_DMTSoft clays to dense sandsOCR, settlement input; subgrade assessment
MASWV_s profile, G_maxAll soils / rockSite class, G_max; muskeg thickness
Seismic RefractionV_P, layer depthsRock / stiff soilsDepth to rock, rippability

Selection hierarchy:

  1. If settlement governs → CPTu + DMT (primary), VST (soft clay verification)
  2. If liquefaction governs → CPTu preferred over SPT alone; MASW for G_max
  3. If rock depth / rippability governs → Seismic refraction first; supplement with borings
  4. If dynamic stiffness governs → MASW primary; seismic CPT if depth resolution needed
  5. If budget is limited (short line) → MASW + selective SPT borings; skip PMT unless abutment design is involved
Supplemental reference

How far to trust an SPT–CPT conversion

Converting between N and qc is routine when a corridor has old SPT borings and new CPT soundings. A Florida DOT data set (six sites, safety-hammer SPT, electric CPT) shows the limits:

Soil (USCS)Linear fit (qc in MPa)R2
Fine sand (SP)qc = 0.291N + 2.430.60
Silty fine sand (SM)qc = 0.12N + 5.00.35
Silty clayey fine sand (SM/SC)qc = 0.22N + 2.60.37
Fine sand with silt (SP-SM)qc = 0.15N + 7.20.11
Clayey fine sand (SC)qc = 0.06N + 5.70.09

Only clean sand gave a usable correlation, and its qc/N ratio matched the published values; sands with more than about 10% fines scattered badly and had higher qc/N than the literature. Treat a converted N or qc as a screening value. For design, calibrate with side-by-side SPT and CPT at a few stations in each geologic unit, and prefer the Robertson soil-behavior-type ratios (above) over a single constant.

Source: Jarushi, F., AlKaabim, S. and Cosentino, P. (2015). “A New Correlation between SPT and CPT for Various Soils.” Int. J. Geological and Environmental Engineering 9(2) · Robertson, P. K. and Cabal, K. L. (2010). Guide to Cone Penetration Testing for Geotechnical Engineering, 4th ed. Gregg Drilling & Testing, Inc.

Selecting in situ tests for track subgrade

Only two things need answering. For track subgrade, in situ testing has to establish strength (bearing) and stiffness (deformation), plus where the layering changes. Tests support design in one of two ways:

  • Indirectly: test result → soil parameter → design method. For example, vane su → bearing capacity.
  • Directly: test result → performance through a correlation. For example, CPT qc → subgrade modulus (Er ≈ 14 qc) → track modulus (Chapter 2.3, Section 2.3.6).
Table 7-SW1. Suitability of in situ tests for su and deformation in cohesive soils
TestVery soft claySoft clayMedium clayStiff claySilty claySilt
Field vaneAABCCD
CPTAAABBC
CPTuAAABBC
DMTAAAAAB
PMTBBAABC
SPTDCBAAA

A = high suitability; B = moderate; C = limited; D = not applicable.

Strengths and limitations.

  • In situ tests reach soils that are hard to sample, test a larger volume, give a near-continuous profile, and are quick and inexpensive.
  • Their drainage and boundary conditions are not known, the disturbance they cause is not known, they load the soil differently from track, at higher strain rates, and they say little about behavior under repeated load.

Choosing the test. CPT, vane and DMT depend least on the operator. Where stratigraphy is complex or variable, use more of a cheaper test. Where it is simple, fewer, more expensive tests are acceptable.

After Selig & Waters (1994), chs. 4 and 10. Full reference under Supplemental References.

Empirical equation note · this section

Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.

← Previous · 4.0 Subsurface Exploration Chapter 4.1 — Borings and Sampling
Next · 5.0 Testing → Chapter 5.2 — Laboratory Testing Program