In situ testing provides continuous or near-continuous soil and rock characterization without the inherent sample disturbance associated with laboratory testing.
Each question is worked in the same five parts as the examples.
Question 5.1-1: Corrected Tip Resistance and su
Problem Statement
A bridge approach fill on a Class I railroad has been settling, and the abutment is to be checked for bearing on the clay beneath it. A piezocone sounding through the fill reached the clay, and at 30 ft it recorded the tip resistance and pore pressure shown. The engineer must correct the tip resistance and estimate the undrained strength of the clay for the abutment bearing check.
Given and required for Question 5.1-1.
Given
Variable
Value
Description
qc, u2
6.80 tsf; 0.95 tsf
a
0.82
σv
1.95 tsf
Nkt
13
Required
(a) qt
(b) su
Equations
Eq. 5.1-1: qt = qc + u2(1 − a) — corrected tip resistance
(a) qt = 6.97 tsf. (b) su = 0.386 tsf (772 psf), a medium clay.
The value is suitable input for abutment bearing capacity (Chapter 6.1) once Nkt is confirmed for this clay.
Question 5.1-2: Vane Strength, Sensitivity and Design Strength
Problem Statement
A Class I railroad embankment along a lakeshore is to be widened for a passing track, over a highly plastic lacustrine clay. Field vane tests at 12 ft gave the peak and remolded torques shown. The engineer must convert the readings to strength, find the sensitivity, and give the design strength for the widening, noting whether the clay triggers an enhanced seismic review.
Eq. 5.1-8: St = su,peak / su,remolded — sensitivity
Eq. 5.1-7: su,design = μ su,peak — Bjerrum; μ = 0.85 at PI 40, 0.75 at PI 60, 0.65 at PI 80
Steps
Step 1 · (a) Peak
6 × 8.6 / 0.1438
359 psf
↓
Step 2 · (b) St
Remolded 6 × 1.4 / 0.1438 = 58 psf; 359 / 58
St = 6.1
↓
Step 3 · (c) Design
μ at PI 70% = 0.70; 0.70 × 359
251 psf
↓
Step 4 · (d) Trigger
6.1 < 8
Not triggered
↓
Solution
Design su ≈ 250 psf; St = 6.1.
Solution
(a) 359 psf. (b) St = 6.1. (c) 250 psf. (d) Not triggered.
The clay is sensitive: it will lose most of its strength if disturbed. Load it in stages with piezometer control rather than relying on the design value at one placement.
Question 5.1-3: Site Class and Gmax of a Soft Site
Problem Statement
A new intermodal ramp track is planned on soft ground beside a river. An MASW survey gave the average shear wave velocity of the upper 100 ft and the velocity and unit weight of the upper layer shown. The engineer must assign the seismic site class, find the small-strain modulus of the upper layer, and explain what the results mean for the track and structures.
Given and required for Question 5.1-3.
Given
Variable
Value
Description
Vs,30
580 ft/s
γ, Vs
110 pcf; 410 ft/s
Upper layer
Required
(a) Site class
(b) Gmax of the upper layer
(c) Significance
Equations
Eq. 1: Gmax = (γ/g) Vs²
Steps
Step 1 · (a) Class
580 < 600 ft/s
Site Class E
↓
Step 2 · (b) Gmax
(110/32.2) × 410² = 3.416 × 168,100
574,000 psf = 287 tsf
↓
Solution
Class E; Gmax = 287 tsf.
Solution
(a) Site Class E. (b) Gmax ≈ 287 tsf. (c) Large amplification and a soft subgrade.
Class E carries the largest code amplification factors at low to moderate shaking, and a site-specific response analysis is advisable. The low stiffness also suggests the subgrade may need improvement (Chapter 7.2) to meet track modulus requirements.
Question 5.1-4: Depth to Rock From Seismic Refraction
Problem Statement
A Class I railroad plans to widen a rock cut to add a second track. A two-layer seismic refraction line along the cut gave the overburden and rock velocities and the crossover distance shown. The engineer must estimate the depth to rock and say whether the rock can be ripped or will need blasting next to the operating track.
Given and required for Question 5.1-4.
Given
Variable
Value
Description
V1, V2
3,800 and 9,200 ft/s
Overburden and rock
xc
48 ft
Crossover distance
Rippability
Difficult: 8,000 to 12,000 ft/s
Table in Section 5.1
Required
(a) Depth to rock
(b) Whether blasting is likely
Equations
Eq. 5.1-18: h = (xc/2) √[(V2 − V1)/(V2 + V1)]
Steps
Step 1 · (a) h
24 × √(5,400/13,000) = 24 × 0.6445
h = 15.5 ft
↓
Step 2 · (b) Rippability
9,200 ft/s
Difficult: blasting likely
↓
Solution
About 15.5 ft to rock; blasting likely.
Solution
(a) About 15.5 ft. (b) Blasting is likely.
Blasting near active track needs advance notice to the railroad, state explosive permits and a vibration limit agreed with the railroad. Confirm the rock depth with a boring before the excavation is priced.
Question 5.1-5: Dilatometer Parameters and Constrained Modulus
Problem Statement
A dilatometer sounding was made through the foundation of a railroad embankment that is to be raised 4 ft. At 14 ft, above the water table, the corrected pressures and effective stress are as shown. The engineer must compute the dilatometer indices, identify the soil type and find the constrained modulus to be used in the settlement estimate for the raise.
A KD this low is typical of loose, normally consolidated sand. ED is not a design modulus; MDMT is, and it feeds the immediate settlement estimate for the widening (Chapter 6.2). The OCR correlation is for clays (ID < 1.2) and is not used here.
Empirical equation note · this section
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
IS-12 Corrected cone resistanceqₜUse: All piezocone (CPTu) soundings; essential in soft clays and silts. Limits: Correction negligible in clean sands; critical in soft fine-grained soils. Requires u2 filter position.
IS-14 Undrained shear strength from CPTSᵤUse: Fine-grained soils penetrated undrained (Ic > ~2.6). Limits: Nkt depends on reference test (vane, CIUC, DSS) and plasticity; calibrate locally. Use Nkt toward upper end for conservative Su.
IS-23 Flat dilatometer (DMT) intermediate parametersI_D, K_D, E_DUse: All soils penetrable by the blade; ID < 0.6 clay, 0.6–1.8 silt, >1.8 sand. Limits: ED is not a design modulus; convert with MDMT = RM · ED (Marchetti 1980).
IS-25 Field vane strength correctionSᵤ (field)Use: Soft clays, embankment stability on soft ground; based on back-analyzed failures. Typical PI 5–100%. Limits: Not applicable to fissured, varved, or organic clays without local calibration. Scatter about ±25%.
IX-09 At-rest earth pressure coefficientK₀Use: Uncemented soils on primary unloading. Limits: Not valid on reloading or for compacted fills, where K0 is governed by compaction stresses. Cap at passive limit.
IX-13 Small-strain shear modulus (Hardin)G_maxUse: Uncemented clays and sands; lab resonant-column basis. Limits: Underestimates aged/cemented soils; field Vs (Gmax = ρVs2) is preferred.
Question 5.1-6: Time-Zero Drift in a Hi-Rail GPR Ballast Survey
Problem Statement
A Class I railroad located in Kansas ran a hi-rail GPR survey to map ballast thickness over a mile of track with recurring surface defects. The contractor’s section shows the ballast–subballast interface getting deeper toward the end of the line. Reviewing the raw data, the engineer finds that the air-wave first break (time zero) also arrives later toward the end of the line, as it does when the electronics warm up. A test pit at the start of the line found the interface 22 in. below the top of tie. The engineer must calibrate the velocity and decide whether the ballast really thickens (Section 5.1.15.4).
Figure 5.1-17. Question 5.1-6: schematic radargram with time-zero drift.
Given
Variable
Value
Description
t0
1.8 ns at start; 2.6 ns at end
Air-wave first break (time zero)
tr
9.4 ns at start; 10.2 ns at end
Interface reflection, raw two-way time
dpit
22 in.
Interface depth at the test pit (start of line)
c
11.8 in./ns
Speed of light in air
Required
(a) Wave velocity v in the ballast from the test pit
(b) Relative dielectric constant εr
(c) Interface depth at the end of the line with time-zero correction
(d) Apparent depth at the end if the drift is ignored, and the error
Equations
Eq. 1: d = v (tr − t0) / 2
Eq. 2: εr = (c / v)² (Section 5.1.15)
Steps
Step 1 · (a) Velocity
t = 9.4 − 1.8 = 7.6 ns; v = 2 × 22 / 7.6
v = 5.79 in./ns
↓
Step 2 · (b) Dielectric constant
(11.8 / 5.79)² = 2.04²
εr = 4.2
Spot check: A value of about 4 is typical of clean, fairly dry ballast; fouled or wet ballast reads higher.
↓
Step 3 · (c) Corrected depth at end
t = 10.2 − 2.6 = 7.6 ns; d = 5.79 × 7.6 / 2
d = 22.0 in.: no change in thickness
↓
Step 4 · (d) Uncorrected depth at end
Using the start time zero: t = 10.2 − 1.8 = 8.4 ns; d = 5.79 × 8.4 / 2
d = 24.3 in.: an apparent 2.3 in. of thickening
Spot check: The 0.8 ns drift times v/2 = 0.8 × 2.9 = 2.3 in., the same error.
↓
Solution
v = 5.79 in./ns; εr ≈ 4.2; corrected depth 22 in. at both ends; the apparent thickening is a 2.3-in. artifact of time-zero drift.
Solution
(a) v ≈ 5.8 in./ns. (b) εr ≈ 4.2. (c) 22 in., the same as at the test pit. (d) 24.3 in. if the drift is ignored: a false 2.3 in. of thickening.
The ballast does not thicken; the trend in the contractor’s section is a processing error. Ask for the data to be reprocessed with time zero picked trace by trace (or at least per file), and for a second test pit or core toward the end of the line to confirm the velocity, because a change in fouling or moisture also changes εr and the depth. Look for the cause of the surface defects elsewhere, for example in the subballast or subgrade (Chapter 2.3).