5.1.16 Borehole Geophysical Logging

In situ testing provides continuous or near-continuous soil and rock characterization without the inherent sample disturbance associated with laboratory testing.
Authors: Daniel P. Colwell and Mario Ruel
5.1.16 Borehole Geophysical Logging

Many railroad borings are drilled by rotary or wash methods with samples only at intervals, and rock is often cored only where it matters most. Borehole geophysical logs are run in the open or cased hole after drilling and fill the gaps between samples. They give a continuous record, by depth, of properties that relate to clay content, density, water content, fracturing and seismic velocity. They also give a consistent way of correlating layers from boring to boring. Logging costs little per foot compared with continuous coring, but the hole can usually be logged only once before it is grouted or caves, so the logs must be planned before drilling starts (ASTM D5753).

Table 5.1-12. Borehole geophysical logs useful in geotechnical work
LogMeasuresHole conditionsGeotechnical use
Natural gamma (total or spectral)Natural radioactivity (potassium, uranium, thorium), mostly from clay mineralsOpen or cased (PVC or steel), wet or dryClay content; sand-clay boundaries; correlating till and shale marker beds between borings
Electromagnetic induction (conductivity)Electrical conductivity of the ground around the holeOpen or PVC-cased; not in steelClay layers; saline or contaminated groundwater; pyritic or graphitic zones
Resistivity and spontaneous potential (SP)Resistivity of the formation; natural voltagesOpen, fluid-filledLithology; permeable beds; water quality
NeutronHydrogen content, which is water content below the water table and in clayOpen or cased; licensed radioactive sourcePorosity and water content; with density, clay identification
Gamma-gamma (density)Bulk density from back-scattered gamma raysOpen or cased; licensed source; needs a caliper correctionIn-place density of soil and rock; loose or disturbed zones; voids
CaliperHole diameterOpen holeWashouts, caving, cavities and soft zones; corrects the nuclear logs. In air-filled holes, gamma-gamma back-scatter can serve as a caliper (Mathew and Anderson)
Temperature, differential temperature, fluid conductivity, flowmeterFluid temperature, salinity and vertical flow in the holeOpen, fluid-filledWater-bearing fractures and solution zones; which zones carry the flow (Howard)
Full-waveform sonic, P-S suspensionP- and S-wave velocity of the wallOpen, fluid-filledSmall-strain modulus; rock quality; seismic site class
Optical and acoustic televiewerImage of the borehole wallOpen; clear fluid for opticalFracture orientation, aperture and spacing for kinematic analysis (Section 5.1.0)
Borehole radar (single-hole or crosshole)Radar reflections and transmissionOpen or PVC; resistive rockFracture zones and voids up to tens of feet from the hole, with orientation
Crosshole seismic and tomographyP- and S-wave travel times between holesTwo or more holes, cased and grouted (ASTM D4428)Velocity profile; velocity map between holes; fractured or weak zones
Borehole gravityGravity, giving bulk density over a large volumeLarge-diameter holeAverage density away from the disturbed wall; rarely used in shallow work

Logging overburden

Greenhouse and Pehme logged rotary holes through thick glacial deposits in southern Ontario to establish the stratigraphy and properties without coring every hole. The approach transfers well to railroad corridors:

  • Case each hole with 3-in. PVC drainage pipe, capped at the bottom and filled with fresh water just before logging. The nuclear tools can then be run safely without the hole caving onto them.
  • Log beside at least one continuously cored hole, and run the tools in calibration pits of known density, water content and clay content. The logs can then be read quantitatively, not only as “sand” or “clay.”
  • Distinctive, widespread units (a dense, bouldery till or a clay till) can be recognized on several logs at once and used as marker beds between borings. Units that look alike in drillers’ logs can often be told apart on the geophysical logs.
  • With natural gamma, neutron and gamma-gamma logs together, porosity, clay content and density can be estimated statistically for every layer the hole crosses.

Crosshole seismic tomography in rock

Sources fired in one hole and receivers in another give travel times along many crossing ray paths. These can be inverted for a map of P-wave velocity between the holes. Ivansson showed that the simple straight-ray solution has artifacts from travel-time errors and from bending of rays around slow zones. Check the map against synthetic travel times from a trial model before interpreting it. New used a “representative velocity” grid with points about 3 ft apart in granite and found that velocity reductions matched the observed fracturing. Velocity can be related to rock quality through the velocity index:

Eq. 5.1-24: VI = (VF / VL)2, where VF = field P-wave velocity of the rock mass and VL = P-wave velocity of intact core. VI is roughly equal to RQD/100 (Deere et al. 1967; RK-13), because open joints slow the wave in the field but are absent from the intact core.

Correct each travel time for the trigger and instrument delay, and use the true distance between source and receiver from deviation surveys of both holes. A 1-ft error in a 40-ft spacing changes the velocity by 2.5% and the velocity index by about 5%.

Borehole radar

Single-hole radar with the transmitter and receiver about 40 ft apart showed fracture zones that cross the hole as attenuation and delay of the direct wave. Fractures and voids away from the hole showed as reflections, and their angle gave the orientation of the zone (Olsson and Nilsson). Reflections came from up to about 145 ft away, and an air-filled drift was detected about 100 ft from the hole. Wright, Watts and Bramsoe detected an anomalous zone extending more than 65 ft from the hole in granite. Radar needs resistive ground: it works in fresh crystalline rock, limestone and dry sand, and fails in clay, shale and saline water.

Log quality

A log is only as good as its calibration (Hill). Calibration follows three steps: recorder, system, then tool. Ask the logging contractor for signed and dated calibration records, a field calibration check before and after logging, and a repeat run over a short section to show that the logs repeat. Depth control matters: tie the depth reference to the ground surface or top of casing and check it against a known feature such as the casing shoe. Have the engineer or a trained representative at the hole, because problems found at the office cannot be fixed once the hole is grouted.

For railroad work: Natural gamma and EM conductivity logs run in PVC-cased holes are cheap ways to trace soft clay layers between borings along an embankment or under a bridge approach. Caliper, density and televiewer logs locate voids, solution openings and mine workings at bridge piers and culverts (Chapter 2.11, Soluble Ground and Karst; Chapter 3.10, Mining and Man-Made Hazards). Crosshole seismic or radar between borings at a pier can show whether a weak zone seen in one core continues between the holes. Nuclear logging tools carry licensed radioactive sources, so they need a qualified logging contractor and the source handling rules on the right-of-way. Grout every hole after logging, as the railroad requires, so it does not become a path for water under the track.

Example 5.1-5: Rock Quality Between Borings From Crosshole P-Wave Travel Times

Problem Statement

A new bridge pier for a Class I railroad located in Kentucky will bear on limestone. Core from boring B-2 shows a broken zone near 30 ft, but B-1, 40 ft away, shows sound rock at that depth. A crosshole P-wave survey was run between the two borings to see whether the weak zone extends across the pier footprint. The engineer must convert the travel times to velocities, estimate rock quality, and decide where to put an added core boring.

Overburden Limestone Fractured or solution-enlarged zone? B-1 (source)B-2 (receiver) 20 ft30 ft40 ft L = 40.0 ft (from deviation surveys) Given Measured first arrivals:20 ft: 2.70 ms30 ft: 3.90 ms40 ft: 2.45 ms Trigger delay 0.10 msIntact core Vₗ = 18,000 ft/s Required(a) Vₚ at each depth(b) Velocity index(c) Estimated RQD and the zone to target
Figure 5.1-18. Example 5.1-5: crosshole P-wave survey between two borings at a bridge pier in limestone.

Given

VariableValueDescription
L40.0 ftSource to receiver distance at each depth, from deviation surveys of both holes
tm2.70, 3.90, 2.45 msMeasured first-arrival times at 20, 30 and 40 ft
td0.10 msTrigger and instrument delay, from a zero-offset test
VL18,000 ft/sP-wave velocity of intact core (laboratory pulse velocity)

Required

  • (a) Field P-wave velocity VF at each depth
  • (b) Velocity index at each depth
  • (c) Estimated RQD, and where to put the added boring

Equations

  1. Corrected time: t = tm − td
  2. Velocity: VF = L / t
  3. Eq. 5.1-24: VI = (VF / VL)2; RQD ≈ 100 VI (%)

Steps

Step 1 · Correct the times
2.70 − 0.10; 3.90 − 0.10; 2.45 − 0.10
t = 2.60, 3.80, 2.35 ms
↓
Step 2 · (a) Velocities
40.0 / 0.00260; 40.0 / 0.00380; 40.0 / 0.00235
VF = 15,400; 10,500; 17,000 ft/s
Spot check: 15,385 × 0.00260 = 40.0 ft ✓.
↓
Step 3 · (b) Velocity index
(15,385 / 18,000)2 = 0.8552; (10,526 / 18,000)2 = 0.5852; (17,021 / 18,000)2 = 0.9462
VI = 0.73; 0.34; 0.89
↓
Step 4 · (c) Estimated RQD
100 × VI
RQD ≈ 73% (fair) at 20 ft; 34% (poor) at 30 ft; 89% (good) at 40 ft
Spot check: ignoring the 0.10-ms delay at 30 ft gives 40 / 0.00390 = 10,260 ft/s and VI = 0.32, so the delay changes the answer only slightly here, but by more on shorter paths.
↓
Solution
The slow path at 30 ft (VI ≈ 0.34) shows that the poor zone seen in B-2 extends between the borings. Core a third boring near the middle of the footprint through the 25- to 35-ft interval.

Solution

(a) 15,400, 10,500 and 17,000 ft/s. (b) VI = 0.73, 0.34 and 0.89. (c) Estimated RQD about 73%, 34% and 89%; the weak zone near 30 ft continues across the footprint.

A single straight path gives the average along the path, not the location of the weak rock along it. Shoot the 25- to 35-ft interval at 1- to 2-ft depth steps, with source and receiver offset in depth to get crossing rays, and make a tomogram if the budget allows. Core a third boring near the middle of the footprint and check the core RQD against the velocity index before using the correlation for design. In limestone, a slow zone may be an open or clay-filled solution feature rather than fractured rock. If so, the pier needs the karst treatment of Chapter 2.11 rather than only a lower bearing value.

Source: Killeen (ed.) (1986), GSC Paper 85-27: Greenhouse and Pehme; Ivansson; New; Black; Olsson and Nilsson; Wright, Watts and Bramsoe; Mathew and Anderson; Howard; Hill. ASTM D5753; velocity index after Deere et al. (1967). Summarized and paraphrased; units converted. Full references under S9, S10, S11.