The sand cone test measures the in-place density of compacted fill directly: a hole is dug through a base plate, the soil removed is weighed, and the hole’s volume is found by filling it with a calibrated, free-flowing sand. It needs no radioactive source, so it is the referee test where nuclear gauge results are in dispute, and the calibration test for the gauge on each new fill material. The result feeds the compaction acceptance check (Section 5.3.2.5).
Equation 5.3-7. Sand cone density
Wcone = sand to fill the cone and plate opening (calibrated); ρsand = bulk density of the sand (calibrated); 1 g/cm³ = 62.43 pcf. ASTM D1556.
A sand cone test was run on a lift of embankment fill for a siding on a Class I railroad located in Indiana. The masses are illustrative of a typical field test. The specification requires 95% of the standard Proctor maximum dry unit weight of 120.5 pcf at a water content within 2 points of optimum (12.4%).
| Variable | Value | Description |
|---|---|---|
| ρsand | 1.52 g/cm³ | Calibrated sand |
| Wcone | 1,580 g | Cone and plate |
| Wbefore, Wafter | 7,230 g; 2,450 g | Jar + cone + sand |
| Wmoist | 4,400 g | Soil from the hole |
| w | 11.6% | Oven-dry |
| γd,max, wopt | 120.5 pcf; 12.4% | Standard Proctor |
The lift is at 97% relative compaction, 0.8 points dry of optimum, and passes.
Keep trains and heavy equipment away from the test while the sand runs: vibration packs the sand, overstates the hole volume and understates the density. If a nuclear gauge is being used on the same fill, this test is its correlation point.
Open the sand cone calculator →
Hole volume from the calibrated sand, moist and dry unit weight, relative compaction and the water content check against optimum.
Procedures are summarized in original wording; equations and tabulated values are standard or published. Sample data are those printed in the cited laboratory manual unless stated otherwise.