↑ Parent Menu⌂ Main Menu
← Chapter 5.3 Construction Monitoring and Field Testing
GHRM
Railway Ground Hazard Risk Management · 5.0 · Testing
Sections · click a car to open it

5.3.20 Suction and Seasonal Moisture Monitoring of Earthworks

Construction monitoring is the geotechnical consultant's final opportunity to verify that subsurface conditions match design assumptions, that materials meet…
Authors: Daniel P. Colwell and Mario Ruel
5.3.20 Suction and Seasonal Moisture Monitoring of Earthworks

Pore pressure in a clay embankment changes with the season and with the vegetation, and is often negative (suction) for much of the year. Standpipes measure only positive pressure. Monitoring for seasonal behaviour therefore needs instruments that read suction, and readings through at least one full dry and wet season; a few standpipes read for a few months are unlikely to capture the range, and the year monitored may not be typical (O'Brien, 2013, p. 30).

Table 5.3-12. Measurements for seasonal earthwork monitoring
MeasurementInstrument or testNotes
Pore pressure and suction in the fillTensiometers or suction-reading piezometers at 3 to 6 ft and deeperThe UK studies used flushable piezometers able to read suction ("geopiezometers") through dry summers
Lateral movementInclinometers at mid-slope and near the crestMost movement is in the upper few feet; read monthly to see the seasonal cycle
Crest and track settlementExtensometers, survey points, track geometry car dataCompare with soil moisture deficit, not just rainfall
Near-surface permeabilityGuelph permeameter at the slope surfaceGives field-saturated k of the cracked near-surface zone
ClimateSite rain gauge and published soil moisture or evapotranspiration dataA site gauge can differ from the regional record

After O'Brien (2013), pp. 21–25.

Laboratory suction measurement

A European round-robin compared the laboratory methods for measuring or controlling suction on identical specimens: axis translation (pressure plate and suction-controlled oedometer), high-capacity tensiometers, the osmotic method and the dewpoint potentiometer (Tarantino et al., 2011, pp. 129–140). Each covers a different range and has its own errors; contact between specimen and plate, for example, changed the measured water content in the pressure plate. Psychrometer readings were found unreliable below a few hundred kPa (Taibi et al., 2011, p. 50). Ask the laboratory which method it will use, and specify the drying or wetting path to match the field condition being modelled.

Sources

Paraphrased from the published sources below; values are converted to English units. Individual railroads, clients and projects are not named.

  • O'Brien, A. S. (2013). The assessment of old railway embankments – time for a change? In Gallipoli (ed.), Partial Saturation in Compacted Soils, pp. 19–32. ICE PublishingFind source ↗
  • Tarantino, A., Gallipoli, D. et al. (2011). Benchmark of experimental techniques for measuring and controlling suction. Géotechnique 61(4); reprinted in Partial Saturation in Compacted Soils, pp. 129–140Find source ↗
  • Taibi, S., Fleureau, J. M. et al. (2011). Some aspects of the behaviour of compacted soils along wetting paths. Géotechnique 61(5), 431–437; reprinted in Partial Saturation in Compacted Soils, pp. 45–53Find source ↗
← Previous · 5.0 Testing Chapter 5.2 — Laboratory Testing Program
Next · 5.0 Testing → Chapter 5.4 — Geo-Environmental Testing on Railroad Corridors