↑ Parent Menu⌂ Main Menu
← Chapter 5.3 Construction Monitoring and Field Testing
GHRM
Railway Ground Hazard Risk Management · 5.0 · Testing
Sections · click a car to open it

5.3.8 Inclinometer Monitoring

Construction monitoring is the geotechnical consultant's final opportunity to verify that subsurface conditions match design assumptions, that materials meet…
Authors: Daniel P. Colwell and Mario Ruel
5.3.8 Inclinometer Monitoring

Inclinometers measure lateral ground movement (horizontal deflection) in embankments, slopes, and retaining walls. A probe is lowered through a casing installed in a near-vertical borehole to measure deviation from vertical.

Slope Stability Radar
Slope Stability Radar
5.3.8.1 Deflection Calculation

Incremental displacement:

δ_h = L × sin(θ) (in. per segment)

where L = probe wheel spacing (usually 2.0 ft) and θ = tilt angle read by accelerometer (radians or degrees).

Cumulative deflection from depth z to surface:

Δ_H = Σ (L × sin θ_i) (in.)

Plotted as deflection profile vs. depth. The shear zone (zone of maximum rate-of-change of deflection with depth) indicates the failure plane location.

5.3.8.2 Trigger Levels and Action Plans
Table 5.3-3. Inclinometer Trigger Levels — Railroad Applications
Trigger LevelCriteriaAction Required
AlertΔ_H > 0.25 in. in any 7-day periodNotify geotechnical engineer; increase reading frequency to daily
ActionΔ_H > 0.50 in. in any 7-day periodSuspend construction operations in affected zone; convene engineer review
EmergencyΔ_H > 0.10 in./day on 3 consecutive daysImmediately halt all loading; implement emergency support if needed; notify RR dispatcher

Source: typical practice and USACE guidance. Confirm trigger levels against the owner railroad's standards and the project specification.

Reading frequency during active construction:

  • Baseline: 3 readings prior to construction (establish stable reference)
  • Active filling: twice weekly minimum; daily if Alert level reached
  • Post-construction: weekly for first 3 months; monthly until stable

Simple crack monitoring and stabilization follow-up

Before or alongside instruments, crews monitor tension cracks with survey markers driven at the crack and paint marks across it, recording whether it is widening. After stabilization, the course’s program confirms effectiveness through follow-up geotechnical inspections over at least two years, tracked against track-inspection results. Keep records of trench-drain locations, since silt can clog them within 2–6 years.

Figure 5.3-18. Tension crack with a survey marker at a prairie slide site.
Figure 5.3-18. Tension crack with a survey marker at a prairie slide site.
Figure 5.3-19. Tension crack along the track shoulder.
Figure 5.3-19. Tension crack along the track shoulder.

After Geotechnology for Railroaders Program, Module 6.1, Module 7.1, Module 1, Module 6.6; Module 6.1 §05; Module 7.1 §05; Module 1 §10. Full reference under Supplemental References.

Supplemental reference · Hunt (2007), Sections 3.2.3 and 3.3.5

Acoustic emission monitoring and tiltmeters

Acoustic emission. Soil and rock that are deforming give off small stress waves (microseisms) as grains slide and bonds break. Geophones or accelerometers on a waveguide in a borehole count these emissions. Koerner and others (1978) proposed these levels for granular soil, for their equipment and a counting threshold of 0.025 V:

Emission rateInterpretation
NoneStable
10 to 100 counts/minMarginally stable
100 to 500 counts/minDeforming substantially; remedial measures needed now
Over 500 counts/minFailing

In a monitored toe excavation, counts rose after each cut and tapered off; after the fifth cut they rose rapidly within 30 minutes and peaked as the slope failed. On an active slide moving only 0.2 to 0.4 in. per year, emissions located the shear zone after three readings, in a smaller and deeper casing than an inclinometer needs, though the result is qualitative. Thresholds are specific to the equipment and soil, so they must be calibrated on each site.

Tiltmeters measure the rotation of a surface or structure (a retaining wall, abutment or signal mast foundation) with an electrolytic or servo-accelerometer sensor. They are read continuously and are well suited to automatic alarms.

For railroad work: Acoustic emission is a useful early warning on a cut or fill where trains must keep running during excavation at the toe, provided it is calibrated against an inclinometer or survey points. Tiltmeters on walls next to the track, connected to a data logger with a text or signal alarm, give continuous warning that manual inclinometer readings cannot.

Source: Hunt, R. E. (2007). Geotechnical Investigation Methods. CRC Press

Supplemental reference · Feng (ed.) (2017)

Fiber-Optic Strain and Temperature Sensing

Fiber-optic sensors come in two kinds (Wang and Gage, in Feng 2017):

  • Discrete sensors (fiber Bragg gratings, Fabry-Perot cavities, SOFO long-gauge sensors) measure strain or temperature at points along the fiber, with high resolution.
  • Distributed sensors use the cable itself as the sensor. Light scattered back along the fiber (Rayleigh, Raman or Brillouin) is analyzed for strain or temperature every 3 ft (1 m) or so, over cable lengths of miles. Distributed temperature sensing (DTS), distributed strain and temperature (DST) and distributed acoustic sensing (DAS) are the common systems.

In Brillouin systems, a strain of about 20 microstrain gives the same frequency shift as about 1.8°F (1°C) of temperature change. Strain and temperature must therefore be separated, usually with a second, loose-tube fiber that measures temperature only. How the cable is bonded to the ground (grouted in a borehole, glued to a structure, buried in a trench) controls what it actually measures.

For railroad work: A cable grouted in a borehole gives a continuous strain profile and locates a shear zone in the same way as an inclinometer, but it can be read remotely and keeps working after the inclinometer casing has sheared. A cable buried along an embankment crest or a retaining wall picks up developing tension cracks along its whole length. Plan the installation with the vendor: cable type, bonding, temperature compensation and a reading unit that can be left on site with power and communications. A fiber is cheap per foot, but the reading unit is not.

Source: Wang and Gage, “Fiber-optic monitoring in underground rock engineering,” in Feng (ed.) (2017), Ch. 17; Loew et al., Ch. 20. Summarized and paraphrased. Full reference under S27.

← Previous · 5.0 Testing Chapter 5.2 — Laboratory Testing Program
Next · 5.0 Testing → Chapter 5.4 — Geo-Environmental Testing on Railroad Corridors