Compute (N₁)₆₀ using the full correction chain established in Chapter 4.1:
For silty sands (fines content FC > 5%), apply fines correction to obtain the clean-sand equivalent (Idriss and Boulanger 2008):
Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| N60 | SPT blow count = N_meas ⋅ E_m ⋅ C_B ⋅ C_R ⋅ C_S 0.60 | Field test | Standard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633, withdrawn 2025) to correct to N60. | loose sand 4–10, dense 30–50 blows/ft · by USCS group |
| CN | intermediate value computed on this page | Another equation | Computed: C_N = √ 2,117 σ'_v ≤ 2.0 (P_a = 2,117 psf) | project-specific |
| (N1)60 | SPT blow count = C_N ⋅ N60 | Field test | Standard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633, withdrawn 2025) to correct to N60. | loose sand 4–10, dense 30–50 blows/ft · by USCS group |
| σ'v | vertical stress / pore pressure | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |

Using the Youd et al. (2001) relationship (after Rauch 1998) for M_w = 7.5:
Valid for (N₁)₆₀,cs < 30. For (N₁)₆₀,cs ≥ 30, the soil is considered non-liquefiable.

| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| CRR7.5 | 1 34 - (N_1)60,cs + (N_1)60,cs 135 + 50 [10 ⋅ (N_1)_60,cs + 45]^2 - 1 200 | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |

Minimum FS_L acceptance criteria for railroad infrastructure:
| Railroad | FEE Min FS_L | DE Min FS_L | MCE Min FS_L | Governing Standard |
|---|---|---|---|---|
| Common baseline | N/A | 1.2 | 1.0 | Common practice; AREMA Chapter 9 sets no FS_L |
Owner railroads may set different values. Confirm them against the owner railroad's current standards when the work is scoped.
The library's chapter on geotechnical earthquake engineering (J. D. Bray) and the military handbook Soil Dynamics and Special Design Aspects (MIL-HDBK-1007/3) both rest on the Seed and Idriss simplified procedure: compare the cyclic stress ratio an earthquake imposes on a layer with the cyclic resistance ratio the layer can supply, estimated from its corrected SPT blow count. Railroad embankments over loose saturated sand and the approach fills of bridges in river valleys are the usual concerns; lateral spreading toward a channel can move a bridge abutment or pier even when the bridge itself is undamaged.
Equation 6.5-1. Cyclic stress ratio (Seed and Idriss)
Equation 6.5-2. Cyclic resistance ratio for M 7.5 and factor of safety (NCEER clean-sand curve)
MSF = 102.24/Mw2.56; FS = CRR7.5 MSF / CSR
| Correction | Value used by the calculator |
|---|---|
| Energy | ER/60, with ER entered (automatic hammers commonly 75 to 90%) |
| Rod length | 0.75 below 13 ft of rod; 0.85 to 20 ft; 0.95 to 33 ft; 1.0 beyond |
| Borehole and sampler | Entered (1.0 for standard practice) |
| Overburden | CN = (Pa/σ'v)0.5 ≤ 1.7 |
| Fines content | (N1)60cs = α + β(N1)60, α and β from fines content (Idriss and Seed) |
For the eight-layer boring loaded as the calculator's example (amax = 0.25 g, Mw 7.0, water at 5 ft), the lowest factor of safety is 0.77 and 2 of the layers fall below 1.0. These are the loose layers at 10 and 15 ft, just below the water table. The layers at 20 and 35 ft are marginal (factors of safety of about 1.1), and the dense layers at 30 and 40 ft are too dense to liquefy. That pattern, with liquefaction confined to a shallow loose layer, is what drives lateral spreading toward a channel and settlement of the approach fill.
Open the liquefaction triggering calculator →
Layer-by-layer SPT procedure: corrections, fines adjustment, CSR, CRR, magnitude scaling and factor of safety, with a profile chart.
These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.