6.5.11 Representative Data Table

Seismic hazard characterization and liquefaction evaluation are critical components of geotechnical services for railroad infrastructure in seismically active regions.
Authors: Daniel P. Colwell and Mario Ruel
6.5.11 Representative Data Table
Table 6.5-7: Summary Liquefaction Assessment — Class I railroad Corridor located in the Willamette Valley, Oregon
BoringDepth (ft)N_measE_mN₆₀C_N(N₁)₆₀FC (%)ΔN(N₁)₆₀csCRR₇.₅CSR₇.₅FS_LStatus
B-11080.728.21.5412.6224.817.40.1850.3280.56Liquefiable
B-120140.7214.31.2017.2184.121.30.2320.3880.60Liquefiable
B-130220.7222.41.0222.980.423.20.2610.4080.64Liquefiable
B-21060.726.11.549.4285.314.70.1570.3280.48Liquefiable
B-220180.7218.41.2022.1122.124.20.2760.3880.71Liquefiable
B-310240.7224.51.5437.850.037.8NC0.328NCNon-liquefiable
B-320310.7231.61.2038.030.038.0NC0.388NCNon-liquefiable

NC = Non-liquefiable ((N₁)₆₀cs ≥ 30). Computed with the Example 6.5-1 inputs: γ = 120 pcf, water table at 5 ft, a_max = 0.456g, M_w = 7.0 (MSF = 1.19), C_R = 0.85, C_B = C_S = 1.0. FS_L values below 1.20 are flagged against the assumed DE minimum (Table 6.5-4).

Empirical equation note · this section

Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.

  • IS-01 SPT energy & procedure correction N₆₀Use: All soils tested by SPT (ASTM D1586). Normalizes blow count to 60% of theoretical free-fall energy, the basis for most U.S. correlations. Limits: CE ranges ~0.5–1.6 depending on hammer type; use measured energy (ASTM D4633, withdrawn 2025) where available. Rod-length factor ranges differ between Skempton (1986) and Youd et al. (2001).
  • IS-02 SPT overburden normalization (sands) (N₁)₆₀Use: Cohesionless soils; normalizes to σ'v0 = 1 atm. Cap of 1.7 recommended by NCEER workshop. Limits: Not applicable to clays. Unreliable at σ'v0 > ~4,200 psf, about 2 tsf (other CN forms preferred at depth).