Chapter 6.4 — Infiltration and Seepage

How rainfall and water move into and through railroad fills, slopes and subgrade, how that is measured, and what it does to stability.
Author: Daniel P. Colwell

This chapter covers infiltration and seepage for railroad earthworks: rainfall infiltration and wetting fronts, loss of suction in unsaturated soil, steady seepage and seepage forces, internal erosion and filters, pore pressures in slopes, field infiltration testing and drainage design. Water is the most common trigger of railroad ground hazards (Section 3.8.18), so this chapter connects the analysis to the trigger and live ratings of Chapter 3.8.

Typical Values for This Chapter — from the GHRM Soil & Rock Properties Database

Permeability and capillary rise values for infiltration and seepage analyses. English units; every value cites its library source, table and page. For preliminary design and checking test results, not a substitute for site testing.

Permeability and capillary rise (60 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Coefficient of permeabilityGravel, well gradedGW1.0×10⁻¹1.0×10⁰1.0×10¹cm/sLOOK T8.4, p.118
Coefficient of permeabilityGravel, poorly gradedGP1.0×10⁰1.0×10¹1.0×10²cm/sLOOK T8.4, p.118
Coefficient of permeabilityGravel, siltyGM1.0×10⁻⁵1.0×10⁻⁴1.0×10⁻³cm/sLOOK T8.4, p.118
Coefficient of permeabilityGravel, clayeyGC1.0×10⁻⁶1.0×10⁻⁵1.0×10⁻⁴cm/sLOOK T8.4, p.118
Coefficient of permeabilitySand, well gradedSW1.0×10⁻³1.0×10⁻²1.0×10⁻¹cm/sLOOK T8.4, p.118
Coefficient of permeabilitySand, poorly gradedSP1.0×10⁻²1.0×10⁻¹1.0×10⁰cm/sLOOK T8.4, p.118
Coefficient of permeabilitySand, siltySM1.0×10⁻⁵1.0×10⁻⁴1.0×10⁻³cm/sLOOK T8.4, p.118
Coefficient of permeabilitySand, clayeySC1.0×10⁻⁶1.0×10⁻⁵1.0×10⁻⁴cm/sLOOK T8.4, p.118
Coefficient of permeabilityInorganic silt, low plasticityML1.0×10⁻⁷1.0×10⁻⁶1.0×10⁻⁵cm/sLOOK T8.4, p.118
Coefficient of permeabilityInorganic silt, high plasticityMH1.0×10⁻⁷1.0×10⁻⁶1.0×10⁻⁵cm/sLOOK T8.4, p.118
Coefficient of permeabilityInorganic clay, low plasticityCL1.0×10⁻⁷1.0×10⁻⁶1.0×10⁻⁵cm/sLOOK T8.4, p.118
Coefficient of permeabilityInorganic clay, high plasticityCH1.0×10⁻⁸1.0×10⁻⁷1.0×10⁻⁶cm/sLOOK T8.4, p.118
Coefficient of permeabilityOrganic silt/clay, low plasticityOL1.0×10⁻⁶1.0×10⁻⁵1.0×10⁻⁴cm/sLOOK T8.4, p.118
Coefficient of permeabilityOrganic silt/clay, high plasticityOH1.0×10⁻⁵1.0×10⁻⁴1.0×10⁻³cm/sLOOK T8.4, p.118
Coefficient of permeabilityPeatPt1.0×10⁻⁴1.0×10⁻³1.0×10⁻²cm/sLOOK T8.4, p.118
Coefficient of permeabilityUniformly graded coarse aggregate4.0×10⁻²1.3×10⁻¹4.0×10⁻¹cm/sCB T4.1, p.97
Coefficient of permeabilityWell-graded aggregate without fines4.0×10⁻³4.0×10⁻²4.0×10⁻¹cm/sCB T4.1, p.97
Coefficient of permeabilityConcrete sand, low dust content7.0×10⁻⁴7.0×10⁻³7.0×10⁻²cm/sCB T4.1, p.97
Coefficient of permeabilityConcrete sand, high dust content7.0×10⁻⁶7.0×10⁻⁵7.0×10⁻⁴cm/sCB T4.1, p.97
Coefficient of permeabilitySilty and clayey sands1.0×10⁻⁷1.0×10⁻⁶1.0×10⁻⁵cm/sCB T4.1, p.97
Coefficient of permeabilityCompacted silt7.0×10⁻⁸7.0×10⁻⁷7.0×10⁻⁶cm/sCB T4.1, p.97
Coefficient of permeabilityCompacted clay1.0×10⁻⁷cm/sCB T4.1, p.97
Capillary riseSandk ≈ 10⁻² cm/s0.30.50.7ftLOOK T7.20, p.113
Capillary riseSiltk ≈ 10⁻⁴ cm/s3.34.956.6ftLOOK T7.20, p.113
Capillary riseClayk ≈ 10⁻⁶ cm/s32.849.265.6ftLOOK T7.20, p.113
Hydraulic conductivityClean gravelSaturated1.0×10⁰1.0×10¹1.0×10²cm/sDASP T7.1, p.181
Hydraulic conductivityCoarse sandSaturated1.0×10⁻²1.0×10⁻¹1.0×10⁰cm/sDASP T7.1, p.181
Hydraulic conductivityFine sandSaturated1.0×10⁻³3.2×10⁻³1.0×10⁻²cm/sDASP T7.1, p.181
Hydraulic conductivitySilty claySaturated1.0×10⁻⁵1.0×10⁻⁴1.0×10⁻³cm/sDASP T7.1, p.181
Hydraulic conductivityClaySaturated1.0×10⁻⁶cm/sDASP T7.1, p.181
Capillary riseCoarse sand0.30.450.6ftDASP T9.2, p.262
Capillary riseFine sand12.54ftDASP T9.2, p.262
Capillary riseSilt2.513.825ftDASP T9.2, p.262
Capillary riseClay255075ftDASP T9.2, p.262
Coefficient of permeability for dewatering designSandy siltUSACE data5.0×10⁻⁴1.0×10⁻³2.0×10⁻³cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designSilty sandUSACE data2.0×10⁻³3.2×10⁻³5.0×10⁻³cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designVery fine sandUSACE data5.0×10⁻³1.0×10⁻²2.0×10⁻²cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designFine sandUSACE data2.0×10⁻²3.2×10⁻²5.0×10⁻²cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designFine to medium sandUSACE data5.0×10⁻²7.1×10⁻²1.0×10⁻¹cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designMedium sandUSACE data1.0×10⁻¹1.2×10⁻¹1.5×10⁻¹cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designMedium to coarse sandUSACE data1.5×10⁻¹1.7×10⁻¹2.0×10⁻¹cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designCoarse sand and gravelUSACE data2.0×10⁻¹3.2×10⁻¹5.0×10⁻¹cm/sUFC T3-4, p.3-6
Coefficient of permeability by grain sizeGravel1.0×10⁰cm/sATKINSON T6.2, p.78
Coefficient of permeability by grain sizeSand1.0×10⁻³3.2×10⁻²1.0×10⁰cm/sATKINSON T6.2, p.78
Coefficient of permeability by grain sizeSilt1.0×10⁻⁶3.2×10⁻⁵1.0×10⁻³cm/sATKINSON T6.2, p.78
Coefficient of permeability by grain sizeClay1.0×10⁻⁶cm/sATKINSON T6.2, p.78
Typical height of capillary riseGravel1inLOOK23 T4.1, p.98
Typical height of capillary riseCoarse sand12.54inLOOK23 T4.1, p.98
Typical height of capillary riseMedium sand4812inLOOK23 T4.1, p.98
Typical height of capillary riseFine sand122028inLOOK23 T4.1, p.98
Typical height of capillary riseSilt2843.559inLOOK23 T4.1, p.98
Typical height of capillary riseClay79118157inLOOK23 T4.1, p.98
Filter retention (piping) criterion by base soil categoryBase soil category 1> 85% finer than No. 200D15 ≤ 9 × d85 (not less than 0.2 mm)–EM1901 D-1, D-2, p.D-4
Filter retention (piping) criterion by base soil categoryBase soil category 240–85% finer than No. 200D15 ≤ 0.7 mm–EM1901 D-1, D-2, p.D-4
Filter retention (piping) criterion by base soil categoryBase soil category 315–39% finer than No. 200D15 ≤ [(40 − A)/(40 − 15)][(4 × d85) − 0.7 mm] + 0.7 mm (4 × d85 not less than 0.7 mm)–EM1901 D-1, D-2, p.D-4
Filter retention (piping) criterion by base soil categoryBase soil category 4< 15% finer than No. 200D15 ≤ 4 to 5 × d85 (4 × d85 under riprap or surging drains)–EM1901 D-1, D-2, p.D-4
Minimum Bligh creep ratio for dams on pervious foundationsVery fine sand or silt18–EM1901 T9-10, p.9-62
Minimum Bligh creep ratio for dams on pervious foundationsFine to medium sand15–EM1901 T9-10, p.9-62
Minimum Bligh creep ratio for dams on pervious foundationsCoarse sand12–EM1901 T9-10, p.9-62
Minimum Bligh creep ratio for dams on pervious foundationsFine gravel or sand and gravel9–EM1901 T9-10, p.9-62
Open this set in the database ↗
Permeability from CPT soil behavior type and kh/kv (12 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Permeability from soil behavior typeSensitive fine-grainedSBT zone 13.0×10⁻⁸3.0×10⁻⁷3.0×10⁻⁶cm/sROB T6, p.56
Permeability from soil behavior typeOrganic soils – claySBT zone 21.0×10⁻⁸1.0×10⁻⁷1.0×10⁻⁶cm/sROB T6, p.56
Permeability from soil behavior typeClays – silty clay to claySBT zone 31.0×10⁻⁸3.2×10⁻⁸1.0×10⁻⁷cm/sROB T6, p.56
Permeability from soil behavior typeSilt mixtures – clayey silt to silty claySBT zone 43.0×10⁻⁷1.7×10⁻⁶1.0×10⁻⁵cm/sROB T6, p.56
Permeability from soil behavior typeSand mixtures – silty sand to sandy siltSBT zone 51.0×10⁻⁵1.0×10⁻⁴1.0×10⁻³cm/sROB T6, p.56
Permeability from soil behavior typeSands – clean sand to silty sandSBT zone 61.0×10⁻³1.0×10⁻²1.0×10⁻¹cm/sROB T6, p.56
Permeability from soil behavior typeDense sand to gravelly sandSBT zone 71.0×10⁻¹3.2×10⁰1.0×10²cm/sROB T6, p.56
Permeability from soil behavior typeVery stiff sand to clayey sand (OC or cemented)SBT zone 81.0×10⁻⁶3.2×10⁻⁴1.0×10⁻¹cm/sROB T6, p.56
Permeability from soil behavior typeVery stiff fine-grained (OC or cemented)SBT zone 91.0×10⁻⁷1.0×10⁻⁶1.0×10⁻⁵cm/sROB T6, p.56
Permeability anisotropy kh/kvSoft clay – No or slightly developed macrofabric, essentially homogeneousCL-CH11.251.5–ROB T7, p.57
Permeability anisotropy kh/kvSoft clay – Fairly to well-developed macrofabric (discontinuous permeable lenses)CL-CH234–ROB T7, p.57
Permeability anisotropy kh/kvSoft clay – Varved clays and deposits with continuous permeable layersCL-CH3915–ROB T7, p.57
Open this set in the database ↗
Runoff coefficients, design storms and flood risk (57 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Rational method runoff coefficientBusiness – downtownASCE (1960)0.70.8250.95–HDS2 T5.7, p.5-33
Rational method runoff coefficientBusiness – neighborhoodASCE (1960)0.50.60.7–HDS2 T5.7, p.5-33
Rational method runoff coefficientResidential – single-familyASCE (1960)0.30.40.5–HDS2 T5.7, p.5-33
Rational method runoff coefficientResidential – suburbanASCE (1960)0.250.3250.4–HDS2 T5.7, p.5-33
Rational method runoff coefficientIndustrial – lightASCE (1960)0.50.650.8–HDS2 T5.7, p.5-33
Rational method runoff coefficientIndustrial – heavyASCE (1960)0.60.750.9–HDS2 T5.7, p.5-33
Rational method runoff coefficientRailroad yard areasASCE (1960)0.20.30.4–HDS2 T5.7, p.5-33
Rational method runoff coefficientParks, cemeteriesASCE (1960)0.10.1750.25–HDS2 T5.7, p.5-33
Rational method runoff coefficientUnimproved areasASCE (1960)0.10.20.3–HDS2 T5.7, p.5-33
Rational method runoff coefficientLawn, sandy soil, flat < 2%ASCE (1960)0.050.0750.1–HDS2 T5.7, p.5-33
Rational method runoff coefficientLawn, sandy soil, 2–7%ASCE (1960)0.10.1250.15–HDS2 T5.7, p.5-33
Rational method runoff coefficientLawn, sandy soil, steep > 7%ASCE (1960)0.150.1750.2–HDS2 T5.7, p.5-33
Rational method runoff coefficientLawn, heavy soil, flat < 2%ASCE (1960)0.130.150.17–HDS2 T5.7, p.5-33
Rational method runoff coefficientLawn, heavy soil, 2–7%ASCE (1960)0.180.20.22–HDS2 T5.7, p.5-33
Rational method runoff coefficientLawn, heavy soil, steep > 7%ASCE (1960)0.250.30.35–HDS2 T5.7, p.5-33
Rational method runoff coefficientAsphalt pavementASCE (1960)0.70.8250.95–HDS2 T5.7, p.5-33
Rational method runoff coefficientConcrete pavementASCE (1960)0.80.8750.95–HDS2 T5.7, p.5-33
Rational method runoff coefficientRoofsASCE (1960)0.750.850.95–HDS2 T5.7, p.5-33
Highway design storm return periodRural principal arterialAASHTO (1999)50yrHDS2 T1.1, p.1-5
Highway design storm return periodRural minor arterialAASHTO (1999)2537.550yrHDS2 T1.1, p.1-5
Highway design storm return periodRural major collectorAASHTO (1999)25yrHDS2 T1.1, p.1-5
Highway design storm return periodRural minor collectorAASHTO (1999)10yrHDS2 T1.1, p.1-5
Highway design storm return periodRural local roadAASHTO (1999)57.510yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban principal arterialAASHTO (1999)2537.550yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban minor arterialAASHTO (1999)25yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban collectorAASHTO (1999)10yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban local streetAASHTO (1999)57.510yrHDS2 T1.1, p.1-5
Risk the design flood is equaled or exceeded during service life2-year design floodService life 1 yr50%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life5-year design floodService life 1 yr20%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life10-year design floodService life 1 yr10%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life25-year design floodService life 1 yr4%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life50-year design floodService life 1 yr2%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life100-year design floodService life 1 yr1%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life2-year design floodService life 5 yr96.9%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life5-year design floodService life 5 yr67.2%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life10-year design floodService life 5 yr41%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life25-year design floodService life 5 yr18.5%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life50-year design floodService life 5 yr9.6%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life100-year design floodService life 5 yr4.9%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life2-year design floodService life 10 yr99.9%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life5-year design floodService life 10 yr89.3%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life10-year design floodService life 10 yr65.1%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life25-year design floodService life 10 yr33.5%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life50-year design floodService life 10 yr18.3%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life100-year design floodService life 10 yr9.6%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life5-year design floodService life 20 yr98.8%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life10-year design floodService life 20 yr87.8%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life25-year design floodService life 20 yr55.8%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life50-year design floodService life 20 yr33.2%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life100-year design floodService life 20 yr18.2%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life10-year design floodService life 50 yr99.5%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life25-year design floodService life 50 yr87%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life50-year design floodService life 50 yr63.6%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life100-year design floodService life 50 yr39.5%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life25-year design floodService life 100 yr98.3%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life50-year design floodService life 100 yr86.7%HDS2 T4.25, p.4-90
Risk the design flood is equaled or exceeded during service life100-year design floodService life 100 yr63.4%HDS2 T4.25, p.4-90
Open this set in the database ↗
Dewatering permeability and piping (creep ratio) (20 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Minimum weighted creep ratio against piping (Lane)Very fine sand or siltGranular foundation under a structure or excavation8.5–UFC T4-3, p.4-40
Minimum weighted creep ratio against piping (Lane)Fine sandGranular foundation under a structure or excavation7–UFC T4-3, p.4-40
Minimum weighted creep ratio against piping (Lane)Medium sandGranular foundation under a structure or excavation6–UFC T4-3, p.4-40
Minimum weighted creep ratio against piping (Lane)Coarse sandGranular foundation under a structure or excavation5–UFC T4-3, p.4-40
Minimum weighted creep ratio against piping (Lane)Fine gravelGranular foundation under a structure or excavation4–UFC T4-3, p.4-40
Minimum weighted creep ratio against piping (Lane)Medium gravelGranular foundation under a structure or excavation3.5–UFC T4-3, p.4-40
Minimum weighted creep ratio against piping (Lane)Coarse gravel with cobblesGranular foundation under a structure or excavation3–UFC T4-3, p.4-40
Minimum weighted creep ratio against piping (Lane)Boulders with some cobbles and gravelGranular foundation under a structure or excavation2.5–UFC T4-3, p.4-40
Coefficient of permeability for dewatering designSandy siltUSACE data5.0×10⁻⁴1.0×10⁻³2.0×10⁻³cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designSilty sandUSACE data2.0×10⁻³3.2×10⁻³5.0×10⁻³cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designVery fine sandUSACE data5.0×10⁻³1.0×10⁻²2.0×10⁻²cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designFine sandUSACE data2.0×10⁻²3.2×10⁻²5.0×10⁻²cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designFine to medium sandUSACE data5.0×10⁻²7.1×10⁻²1.0×10⁻¹cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designMedium sandUSACE data1.0×10⁻¹1.2×10⁻¹1.5×10⁻¹cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designMedium to coarse sandUSACE data1.5×10⁻¹1.7×10⁻¹2.0×10⁻¹cm/sUFC T3-4, p.3-6
Coefficient of permeability for dewatering designCoarse sand and gravelUSACE data2.0×10⁻¹3.2×10⁻¹5.0×10⁻¹cm/sUFC T3-4, p.3-6
Minimum Bligh creep ratio for dams on pervious foundationsVery fine sand or silt18–EM1901 T9-10, p.9-62
Minimum Bligh creep ratio for dams on pervious foundationsFine to medium sand15–EM1901 T9-10, p.9-62
Minimum Bligh creep ratio for dams on pervious foundationsCoarse sand12–EM1901 T9-10, p.9-62
Minimum Bligh creep ratio for dams on pervious foundationsFine gravel or sand and gravel9–EM1901 T9-10, p.9-62
Open this set in the database ↗
Railroad drainage: design storms and ballast permeability (61 values)
PropertySoil / materialClassConditionLowTypicalHighUnitsSource
Hydraulic conductivityClean gravelSaturated1.0×10⁰1.0×10¹1.0×10²cm/sDASP T7.1, p.181
Hydraulic conductivityCoarse sandSaturated1.0×10⁻²1.0×10⁻¹1.0×10⁰cm/sDASP T7.1, p.181
Hydraulic conductivityFine sandSaturated1.0×10⁻³3.2×10⁻³1.0×10⁻²cm/sDASP T7.1, p.181
Hydraulic conductivitySilty claySaturated1.0×10⁻⁵1.0×10⁻⁴1.0×10⁻³cm/sDASP T7.1, p.181
Hydraulic conductivityClaySaturated1.0×10⁻⁶cm/sDASP T7.1, p.181
Ballast hydraulic conductivity by fouling categoryBallast – CleanParsons (1990)2.5×10⁰3.6×10⁰5.1×10⁰cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Moderately cleanParsons (1990)2.5×10⁻¹7.9×10⁻¹2.5×10⁰cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Moderately fouledParsons (1990)1.5×10⁻¹1.9×10⁻¹2.5×10⁻¹cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – FouledParsons (1990)5.0×10⁻⁴8.7×10⁻³1.5×10⁻¹cm/sLI16 T6.2, p.279
Ballast hydraulic conductivity by fouling categoryBallast – Highly fouledParsons (1990)5.0×10⁻⁴cm/sLI16 T6.2, p.279
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 10%4.9×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 20%2.3×10⁰cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 20%6.3×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 20%1.1×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 30%1.1×10⁰cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 30%1.8×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 30%9.6×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 40%3.8×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 40%8.1×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 40%8.7×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with crushed ballast finesFouling ratio 50%1.7×10⁻¹cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with clayFouling ratio 50%6.1×10⁻²cm/sMATC T5.1.1, p.48
Permeability of fouled ballastBallast fouled with coal dustFouling ratio 50%5.4×10⁻²cm/sMATC T5.1.1, p.48
Design storm for under-track culvertsClass I railroad under-track culverts100yrRRCULV text, p.1
Design storm return periodTrack internal drainageRailroad drainage11.52yrLI16 T6.3, p.282
Design storm return periodSurface ditchRailroad drainage57.510yrLI16 T6.3, p.282
Design storm return periodCulvertsRailroad drainage5075100yrLI16 T6.3, p.282
Design storm return periodBridgesRailroad drainage100yrLI16 T6.3, p.282
Highway design storm return periodRural principal arterialAASHTO (1999)50yrHDS2 T1.1, p.1-5
Highway design storm return periodRural minor arterialAASHTO (1999)2537.550yrHDS2 T1.1, p.1-5
Highway design storm return periodRural major collectorAASHTO (1999)25yrHDS2 T1.1, p.1-5
Highway design storm return periodRural minor collectorAASHTO (1999)10yrHDS2 T1.1, p.1-5
Highway design storm return periodRural local roadAASHTO (1999)57.510yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban principal arterialAASHTO (1999)2537.550yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban minor arterialAASHTO (1999)25yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban collectorAASHTO (1999)10yrHDS2 T1.1, p.1-5
Highway design storm return periodUrban local streetAASHTO (1999)57.510yrHDS2 T1.1, p.1-5
Hydraulic conductivity of compacted soilWell graded clean gravelsGWUFC 3-220-20 Table 3-13.0×10⁻⁴3.0×10⁻³3.0×10⁻²cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilPoorly graded clean gravelsGPUFC 3-220-20 Table 3-13.0×10⁻³3.0×10⁻²3.0×10⁻¹cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilSilty gravelsGMUFC 3-220-20 Table 3-13.0×10⁻⁶3.0×10⁻⁵3.0×10⁻⁴cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilClayey gravelsGCUFC 3-220-20 Table 3-13.0×10⁻⁷cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilWell graded clean sandsSWUFC 3-220-20 Table 3-13.0×10⁻⁴3.0×10⁻³3.0×10⁻²cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilPoorly graded clean sandsSPUFC 3-220-20 Table 3-13.0×10⁻³3.0×10⁻²3.0×10⁻¹cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilSilty sandsSMUFC 3-220-20 Table 3-13.0×10⁻⁶3.0×10⁻⁵3.0×10⁻⁴cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilSand-silt-clay, slightly plastic finesSM-SCUFC 3-220-20 Table 3-13.0×10⁻⁸3.0×10⁻⁷3.0×10⁻⁶cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilClayey sandsSCUFC 3-220-20 Table 3-13.0×10⁻⁷cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilInorganic silts and clayey siltsMLUFC 3-220-20 Table 3-13.0×10⁻⁸3.0×10⁻⁷3.0×10⁻⁶cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilSilt-clay mixtureCL-MLUFC 3-220-20 Table 3-13.0×10⁻⁸cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilLean clayCLUFC 3-220-20 Table 3-13.0×10⁻⁸cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilOrganic silts, low plasticityOLUFC 3-220-20 Table 3-13.0×10⁻⁸cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilElastic siltsMHUFC 3-220-20 Table 3-13.0×10⁻⁹cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilFat clayCHUFC 3-220-20 Table 3-13.0×10⁻⁹cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of compacted soilOrganic claysOHUFC 3-220-20 Table 3-13.0×10⁻⁹cm/sUFC322020 T3-1, p.120
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines20% fouling2.3×10⁰cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay20% fouling6.3×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines30% fouling1.1×10⁰cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay30% fouling1.8×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines40% fouling3.8×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay40% fouling8.1×10⁻²cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – crushed-ballast finesBallast fouled with crushed ballast fines50% fouling1.7×10⁻¹cm/sPARSONS15 T5.1, p.33
Hydraulic conductivity of fouled ballast – clay finesBallast fouled with clay50% fouling6.1×10⁻²cm/sPARSONS15 T5.1, p.33
Open this set in the database ↗
References (16)
  1. ATKINSON – Atkinson, J. (2007). The Mechanics of Soils and Foundations, 2nd ed. Taylor & Francis.
  2. CB – Carter, M. & Bentley, S.P. (2016). Soil Properties and their Correlations, 2nd ed. Wiley.
  3. DASP – Das, B.M. (2010). Principles of Geotechnical Engineering, 7th ed. Cengage.
  4. EM1901 – U.S. Army Corps of Engineers (1993). EM 1110-2-1901, Seepage Analysis and Control for Dams (Change 1).
  5. HDS2 – FHWA (2002). Highway Hydrology, Hydraulic Design Series No. 2, 2nd ed. FHWA-NHI-02-001 (superseded by HDS-2 Highway Hydrology 3rd ed., FHWA-HIF-24-007 (2024)).
  6. HEC20 – FHWA (2001). Hydraulic Engineering Circular No. 20, Stream Stability at Highway Structures, 3rd ed. FHWA NHI 01-002 (superseded by HEC-20 4th ed., FHWA-HIF-12-004 (2012)).
  7. LI16 – Li, D., Hyslip, J., Sussmann, T. & Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis.
  8. LOOK – Look, B.G. (2007). Handbook of Geotechnical Investigation and Design Tables. Taylor & Francis.
  9. LOOK23 – Look, B.G. (2023). Earthworks: Theory to Practice – Design and Construction. CRC Press / Taylor & Francis.
  10. MATC – Parsons, R., Han, J. et al. (2014). Permeability, Resistivity and Strength of Fouled Railroad Ballast. Mid-America Transportation Center Report MATC-UK:148, University of Kansas.
  11. RRCULV – A Class I railroad. Guidelines for Under Track Culverts.
  12. PARSONS15 – Parsons, R.L., Han, J. et al. (2015). Mechanical and Hydraulic Properties of Recycled Railroad Ballast. Mid-America Transportation Center Report MATC-KU 465, University of Kansas.
  13. RAOHAMED – Rao, A.R. & Hamed, K.H. (2000). Flood Frequency Analysis. CRC Press.
  14. ROB – Robertson, P.K. & Cabal, K.L. (2010). Guide to Cone Penetration Testing for Geotechnical Engineering, 4th ed. Gregg Drilling & Testing.
  15. UFC – U.S. Department of Defense (2004). UFC 3-220-05, Dewatering and Groundwater Control (16 January 2004).
  16. UFC322020 – U.S. Department of Defense (2025). UFC 3-220-20, Foundations and Earth Structures (NAVFAC DM-7.2), 16 January 2025.
Correlations (9)
EstimateCorrelationLimits / notesSource
Hazen formulak (cm/s) ≈ C · D10² (mm), C ≈ 1.0–1.5Clean sands; Hazen (1911): C1 = 0.01–0.015 with k in m/sCB Eq. 4.5, p.97
Rational method peak flowQ = C i A (Q in cfs, i in in./hr, A in acres)C from the database (railroad yards 0.20–0.40); small basins only (< 500 acres)HDS2 5.7, p.5-33
Risk of exceedance during service lifeR = 1 − (1 − 1/Tr)^nTr = return period (yr), n = service life (yr)HDS2 Eq. 4.81, p.4-90
Hazen permeability estimatek (cm/s) = C · D10², C ≈ 100 (40–150), D10 in cmClean, uniform sand only; confirm with pumping testsUFC Eq. 3-2, p.3-6
Weighted creep ratio against piping (Lane)Cw = (ΣLv + ΣLh/3) / Δh ≥ tabulated minimum (2.5 boulders … 8.5 very fine sand or silt)Lv, Lh = vertical and horizontal seepage path lengths; Δh = head differenceUFC 4-3, p.4-40
Stream stability ratingR = Σ (wi × ri) over 13 indicatorsExcellent < 32, good 32–55, fair 55–78, poor > 78HEC20 D.2–D.3, p.D.6
Gumbel (EV1) flood quantile, method of momentsxT = x̄ + KT s; KT = −0.45 − 0.7797 ln[−ln(1 − 1/T)]x̄, s = mean and standard deviation of annual maxima; α = 0.7797 s, β = x̄ − 0.45005 sRAOHAMED Eq. 8.2.5–8.2.20, §7.2
Filter permeability and pipe criteriaD15(filter)/d15(base) ≥ 3 to 5; D50(filter)/hole or slot width ≥ 1.0Retention criterion by base soil category in Table D-2; no gap-graded filtersEM1901 Eq. D-1, D-2, p.D-5–D-6
Permeability from Ick = 10^(0.952 − 3.04 Ic) m/s for 1.0 < Ic ≤ 3.27; k = 10^(−4.52 − 1.37 Ic) m/s for 3.27 < Ic < 4.0 (× 100 for cm/s)Approximate guide onlyROB 6, p.56
All correlations ↗

Full database  ·  Laboratory tests  ·  Download Excel  ·  Library documents for this chapter  ·  Calculators for this chapter

Further reading — ICE Manual of Geotechnical Engineering
The chapters below cover the same ground in more depth. They are cited, not reproduced; see Appendix G for the full cross-reference and edition notes.
6.4.0 Purpose and Overview

Most railroad fills and cuts that fail do so during or after wet weather: water ponds against a fill above a plugged culvert, a wetting front advances into a dry clay slope and destroys its suction, or seepage at the toe carries fines out of the embankment. Analysis therefore has to answer three questions: how fast does water get in, where does it go, and what does it do to the forces that hold the ground in place.

Table 6.4-1. Water problems on railroad earthworks and where they are analyzed
ProblemMechanismSection
Rain on a dry or partly saturated slopeWetting front; loss of suction; perched water6.4.1 and 6.4.2
Water ponded against a fillSteady seepage through the fill; seepage force at the toe6.4.3
Fines leaving the toe or a culvert jointInternal erosion and piping6.4.4
River or reservoir drawdownRapid drawdown pore pressure6.4.5
Infiltration systems and drainageField permeability; drain capacity6.4.6 and 6.4.7
6.4.1 Rainfall Infiltration

Rain that reaches the ground either infiltrates or runs off. While the rainfall rate is below the soil's infiltration capacity, all of it enters; once it exceeds it, the excess runs off or ponds. Infiltration capacity falls with time as the near-surface soil saturates, toward a long-term rate close to the saturated hydraulic conductivity. The water moves down as a wetting front: above the front the soil is near saturation, below it the soil keeps its original moisture.

Equation 6.4-1. Green-Ampt infiltration rate

f = Ks [ 1 + (ψf · Δθ) / F ]

where f is the infiltration rate, Ks the saturated hydraulic conductivity, ψf the suction at the wetting front, Δθ the change in volumetric water content, and F the cumulative infiltration depth.

Two consequences matter on the railroad. First, a long, moderate rain does more damage to a clay slope than a short, intense one, because more of it gets in; antecedent rainfall is therefore part of the trigger (Section 3.8.12). Second, a wetting front reaching a less permeable layer (a clay core, rock, an old frozen zone) builds perched water above it, often along exactly the surface where the slope fails.

Rainfall, runoff and submergence. On a railroad the same storm infiltrates the slope, loads the ditches and raises the water against the fill.
Figure 6.4-1. Rainfall, runoff and submergence. On a railroad the same storm infiltrates the slope, loads the ditches and raises the water against the fill.
6.4.2 Unsaturated Soil Behavior

Above the water table, fine-grained soils hold water under suction (negative pore pressure). Suction adds apparent cohesion and is why steep cuts in dry silt and clay stand for years. Wetting removes it. A slope that is stable in a dry season can fail after rain with no rise in the water table at all, simply because the suction it depended on has gone.

Equation 6.4-2. Shear strength of unsaturated soil (extended Mohr-Coulomb)

τ = c′ + (σ − ua) tan φ′ + (ua − uw) tan φb

where (ua − uw) is matric suction and φb the angle describing the strength gained from suction.

Design practice. Do not rely on suction for long-term stability of railroad slopes. Use it to explain why a slope has stood and why it failed after a wet period, and check stability with the suction removed (Chapter 6.3).
6.4.3 Steady Seepage and Flow Nets

Where water stands against a fill for long enough (a blocked culvert, a pond, a river stage that lasts days), flow through the fill approaches steady state. Darcy's law governs the flow, and a flow net (or a seepage model) gives the head everywhere in the fill, the exit gradient at the toe and the quantity of seepage.

Equation 6.4-3. Darcy's law and seepage quantity

q = k i A    Q = k H (Nf / Nd) per unit length

where k is hydraulic conductivity, i the hydraulic gradient, A the area, H the head difference, and Nf, Nd the numbers of flow channels and equipotential drops in the flow net.

Seepage exerts a force on the soil skeleton equal to the gradient times the unit weight of water, acting in the direction of flow. At the downstream toe the flow turns upward and outward, which is why the toe softens, sloughs and is the first place to show distress. For dam and levee-type fills the Kozeny parabola gives a quick phreatic line through a homogeneous section.

Foundation soilEmbankment fillWater ponded against the fill (blocked culvert)Culvert, inlet blockedPhreatic lineSeepage exits at the toe: softening, sloughing, pipingTrack on the crest
Figure 6.4-2. Railroad fill with water ponded against one side behind a blocked culvert. The phreatic line drops through the fill and exits near the downstream toe, where seepage forces soften the toe and can start piping.
Permeability and seepage. Flow nets and seepage forces explain why the toe of a fill with water against it is where distress first appears.
Figure 6.4-3. Permeability and seepage. Flow nets and seepage forces explain why the toe of a fill with water against it is where distress first appears.
6.4.4 Internal Erosion and Piping

When the upward exit gradient at the toe approaches the critical gradient, the effective stress in the soil goes to zero and particles can be carried out. Once a pipe starts it concentrates flow and grows backward toward the water. Culvert joints that have separated, animal burrows and old timber structures in a fill give water the same short cut.

Equation 6.4-4. Critical hydraulic gradient

ic = γ′ / γw ≈ 1.0 for most soils;  factor of safety = ic / iexit, commonly at least 3 for heave and piping
Table 6.4-2. Filter criteria (Terzaghi type) for drains and toe filters
RequirementCriterionPurpose
RetentionD15 filter / D85 soil ≤ 4 to 5Keep soil particles from passing through the filter
PermeabilityD15 filter / D15 soil ≥ 4 to 5Filter much more permeable than the soil
Uniformity and segregationWell-graded filter, placed without segregationConsistent performance
GeotextilesApparent opening size and permittivity chosen for the soilWhere granular filters are impractical
Culvert outlets at the toe of a fill, one pipe section separated. Separated joints let water and fines move through the embankment and are a common start of piping in railroad fills.
Figure 6.4-4. Culvert outlets at the toe of a fill, one pipe section separated. Separated joints let water and fines move through the embankment and are a common start of piping in railroad fills.
6.4.5 Pore Pressures in Slopes

Slope stability analysis (Chapter 6.3) needs the pore pressure on the slip surface. Three ways of describing it are in common use: a phreatic surface (from readings or a seepage model), a pore pressure ratio ru = u / (γz), and a full seepage analysis. Railroad cases that need particular care are listed below.

Table 6.4-3. Pore pressure cases on railroad slopes
CaseApproach
Perched water on a clay or rock contact after rainPhreatic surface on the contact; check with the suction removed
Water ponded against a fill (blocked culvert)Steady seepage at the ponded level; this is the trigger condition for drainage-driven sites
Rapid drawdown after a floodDrawdown analysis; low-permeability fill keeps its high pore pressure while the support of the water outside is removed
Artesian pressure under a clay toePiezometers; uplift on the base of the clay
Live conditionsThe live rating (Section 3.8.26) raises the frequency index when rainfall or stage passes the site's threshold
6.4.6 Drainage Design

Drainage is usually the cheapest and most effective way to reduce the frequency of failure, because it acts directly on the trigger (Table 3.8-79). It only works while it is maintained.

Table 6.4-4. Drainage measures for railroad earthworks
MeasureActs onDesign notes
Ditch cleaning and regradingPonding at the toe; water in the ballastPositive grade to an outlet; invert below the subgrade
Culvert cleaning, upsizing or replacementPonding against the fillCapacity for the design storm (the 100-year event earns the most credit, Table 3.8-81); outlet protection
Subdrains and underdrainsWater in the subgrade and toeFilter-compatible aggregate or geotextile; cleanouts
Toe drains and drainage blanketsSeepage exit at the toeFilter criteria (Table 6.4-2)
Horizontal drainsGroundwater in the slopeSpacing from seepage analysis; monitor outflow
Surface sealing and diversionInfiltration at the crestDivert crest runoff away from cracks
6.4.7 Field Infiltration Testing

Where a design depends on water going into the ground (an infiltration basin, a storm chamber system), measure it. The borehole (single-ring) test below follows a municipal stormwater ordinance procedure that is widely used in the Midwest.

Table 6.4-5. Borehole infiltration test procedure (summary)
StepRequirement
Soil boringExtend at least 5 ft below groundwater; bag samples of each layer between the system bottom and the water table for sieve analysis; density and moisture of each layer; water at drilling and 24 hours; log by USDA texture
Test locationAt least 5 ft from the boring, or a horizontal distance equal to the depth from test bottom to water table, whichever is greater
SetupDrill to the test depth; push a PVC pipe 3 in. below the bottom; bentonite seal in the annulus; clean, uniform bottom; cap the pipe
Pre-soakFill the pipe and let it drain to saturate the soil; record the volume added
ReadingsRecord time and depth at intervals that give about 3 in. or less of decline; when within 12 in. of the bottom, refill to 24 in. above the bottom
EndRepeat until the rate of decline is constant, then two more cycles
TimingSome agencies do not allow testing within 24 hours after rain
06012018024002468Elapsed time (min)Rate (in./hr)Long-term rate K, ordinance methodFalling-head estimate (Hvorslev-type)
Figure 6.4-5. Results of a 4.4-hour borehole infiltration test in sand. The observed rate of decline stayed between about 13 and 24 in./hr late in the test; the ordinance method gave a long-term rate of about 2 to 3 in./hr, and the falling-head estimate settled at about 0.4 to 0.7 in./hr. The spread is why the method, the water table correction and the factor of safety must be stated with any design value.

The ordinance equations assume the wetting front stays above the water table; where it reaches the water table, the equations must be modified, as the worksheet does. Check the field value against grain-size correlations from the sieve analyses; where the correlation gives a higher permeability, the field value is the conservative one to use.

Design value. Apply a factor of safety of 2.0 to the field-tested permeability for capacity design (design permeability equal to one half of the field value), extend the system bottom into the clean sand found in the borings, and carry a bid item for over-excavation of any clay, silt or dirty sand pocket below it. Compacting the natural sand under the system reduces its permeability, sometimes dramatically, so specify how the base is prepared.

Do not test infiltration where groundwater is within a few feet of the surface; the result is meaningless and the site is not suited to infiltration. One recent client request banned infiltration tests outright for that reason.

6.4.8 Cross-References
Table 6.4-6. Related chapters
TopicRefer to
Groundwater characterizationChapter 2.8
Rainfall thresholds and triggersSections 3.8.11 and 3.8.12; Section 3.8.18
Slope stabilityChapter 6.3
Live ratingSection 3.8.26
Design credit for drainageTable 3.8-81
Ground improvement and retaining structuresChapters 7.1 and 7.2
6.4.9 Apps and Analytical Tools10

The web apps and the Geotechnical Analysis Suite calculators and workbook guides for this part of the analysis, gathered here from across the manual in the November 2026 restructure: 10 tools (3 interactive calculators). Where a tool applies to a particular section of this chapter it is also placed in that section in an orange tools strip. Each row lists the chapters and sections where the tool is used. Calculators open on dirtbert.com (sign-in required).

Apps

Each app runs in a web browser on a desktop or a phone, with nothing to install. How to use the apps (1.0.3).

Tools

Groundwater & Seepage
GWFalling Head Tube CalibrationsUsed in Chapter 2.8, 2.8.4 Field Permeability Testingguide onlyGuide
GWFlexible Wall PermeabilityUsed in Chapter 5.2, 5.2.3 Test Methods — ASTM Standards and English Unit Outputsguide onlyGuide
GWInfiltration Calculations & ProcedureUsed in Chapter 3.8, 3.8.12 Rainfall Thresholds and Weather-Based Operating Protocols; Chapter 2.8, 2.8.4 Field Permeability TestingCalculator ▸Guide
GWSeepage Through Dam (Kozeny)Used in Chapter 2.8, 2.8.5 Seepage Analysisguide onlyGuide
GWSlug Test — Bouwer–RiceUsed in Chapter 2.8, 2.8.4 Field Permeability Testingguide onlyGuide
GWSlug Test — HvorslevUsed in Chapter 2.8, 2.8.4 Field Permeability Testingguide onlyGuide
GWUnderseepageUsed in Chapter 3.8, 3.8.4 Hydraulic Failure Mechanisms; Chapter 2.8, Applies to the chapter as a wholeguide onlyGuide
GWWell Construction Summary (BRLF)Used in Chapter 2.8, 2.8.3 Piezometers — Types, Installation, and Monitoringguide onlyGuide
Pavements, Subgrade & Frost
PVCulvert TableoldUsed in Chapter 2.1, 2.1.5 Drainage ElementsCalculator ▸Guide
PVHDPE Pipe DesignUsed in Chapter 2.1, 2.1.9 Utility and Pipeline CrossingsCalculator ▸Guide

Calculator: Ballast Fouling and Drainage (Section 6.4.10)

Calculator: Rainfall, Suction and Shallow Slides (Section 6.4.11)

6.4.10 Ballast Fouling Indices and Drainage Capacity

Fouled ballast is the most common reason a track section stops draining. The fines come mostly from ballast breakdown, with contributions from infiltration from the surface (coal, ore, wind-blown soil), the subballast and the subgrade (pumping). Coarse broken particles do little harm and may even stiffen the ballast, but as fines accumulate they hold water, the voids clog, and geometry deteriorates fastest where fouled ballast and poor drainage occur together.

6.4.10.1 Fouling indices and drainage

Equation 6.4-5. Fouling indices

FI = P4 + P200 (Selig and Waters)   Four-sieve index = 0.4P19 + 0.3P6.7 + 0.2P1.18 + 0.1P0.15

P = percent passing the sieve (sizes in mm; No. 4 and No. 200 in FI).

Equation 6.4-6. Void contaminant index and fouled conductivity

VCI = (1 + ef)/eb × Gs,b/Gs,f × Mf/Mb × 100   kb/k = 1 + (VCI/100)(kb/kf − 1)

e = void ratio, Gs = specific gravity, M = dry mass; b = fresh ballast, f = fouling material.

Table 6.4-7. Fouling categories and intervention levels
CategoryFIPassing 3/4 in. (one railroad's single-sieve criterion)
Clean< 1–
Moderately clean1 to < 10< 25%
Moderately fouled10 to < 2025 to 40%
Fouled20 to < 4040 to 50%
Highly fouled≥ 40> 50%

Intervention levels: FI 30 (drainage reduction) and 40 (highly fouled); four-sieve index 80; 40% passing 3/4 in.; European agencies use 30% passing 14 mm or 22.4 mm.

Table 6.4-8. Drainage condition by relative conductivity
kb/kDrainage
≤ 3Free
3 to 30Very good
30 to 300Good
300 to 3,000Acceptable
3,000 to 300,000Poor
300,000 to 30,000,000Very poor
> 30,000,000Relatively impervious

The fouling index counts the fines twice because they control permeability, but sieving to the No. 200 in the field is impractical, so single-sieve criteria are used for field decisions. Mass-based indices also ignore the type of fines. The VCI measures the share of the ballast voids actually filled, and it is the only one of these measures that accounts for the low specific gravity of coal. At the same 15% fouling by mass, laboratory tests gave about 78% VCI for coal, 65% for clay and 52% for sand, while FI barely separated coal from sand. Above about 40% VCI, geogrid reinforcement adds little and ballast strength falls noticeably.

6.4.10.2 Worked example: sample from a wet spot

Table 6.4-9. Ballast sample: P4 10%, P200 6%, 35% passing 3/4 in., fines 10% of ballast mass (calculator output)
ResultValue
Fouling index16.0 (moderately fouled)
Four-sieve index20.3
Void contaminant index21.0 %
Drainage, silty or coal fines (kf = 2.8 ft/day)Poor drainage (kb/k = 8,547)
Drainage, clay fines (kf = 0.03 ft/day)Very poor drainage

None of the mass-based indices calls for cleaning, yet with clay fines filling a fifth of the voids the ballast drains very poorly. Where wet spots persist, test the fines (Atterberg limits, specific gravity) before deciding between shoulder cleaning, undercutting and subgrade work.

Open the ballast fouling calculator →
Fouling index, four-sieve index, single-sieve category, void contaminant index, fouled conductivity and drainage class.

6.4.10.3 Sources in the library

These documents are in the reference library. The method summaries above are paraphrased; equations are standard or published forms.

  • Railway Geotechnics (Li, Hyslip, Sussmann and Chrismer, 2016), Chapter 3: fouling index, single-sieve criteria and intervention levels.Find source ↗
  • Ballast Railroad Design: SMART-UOW Approach (Indraratna and others), Ballast folder: VCI, conductivity model and drainage classes.Find source ↗Library entry
  • Performance of Geogrid-Stabilised Fouled Ballast in Rail Tracks (thesis), Ballast folder: VCI threshold of 40%.Find source ↗Library entry
  • Permeability, Resistivity and Strength of Fouled Railroad Ballast (MATC report) and Properties of Fouled Railroad Ballast.Find source ↗
  • Track Geotechnology and Substructure Management (Selig and Waters, 1994): ballast fouling sources and effects.Find source ↗Library entry
6.4.11 Rainfall, Matric Suction and Shallow Slope Failure

Many cut and fill slopes along track stand steeper than their friction angle for years and then slide in a wet season. The extra strength comes from matric suction in the soil above the water table, and steady infiltration takes it away. Lu and Likos's Unsaturated Soil Mechanics gives closed-form tools for this. Their Chapter 7 derives the steady suction profile above the water table for a given infiltration or evaporation rate, using Gardner's exponential conductivity function. Their Section 8.2 takes the effective degree of saturation from the van Genuchten water retention curve as Bishop's effective stress parameter χ. Suction then adds a stress Se(ua − uw) to the normal stress on a potential slip plane. Dropping that into the infinite slope equation shows how a slope that is safe in dry weather can fail under steady rain without the water table ever reaching the slip surface.

6.4.11.1 Method

Equation 6.4-7. Steady suction profile, effective saturation and factor of safety

ψ(z) = −(1/α) ln[(1 − q/ks) e−αz + q/ks]  (z above the water table; q infiltration, positive downward)

Se = [1 + (αψ)n]−(1 − 1/n);   suction stress = Seγwψ
F = [c′ + (γd cos²β + Seγwψ) tanφ′] / (γd sinβ cosβ);  d = slip depth

Table 6.4-10. Representative hydraulic parameters (Lu and Likos, Table 7.1)
Soilnα (1/kPa)α (1/ft of head)ks (m/s)
Sand4 to 8.50.1 to 0.50.3 to 1.510−2 to 10−5
Silt2 to 40.01 to 0.10.03 to 0.310−6 to 10−9
Clay1.1 to 2.50.001 to 0.010.003 to 0.0310−8 to 10−13

α in 1/ft of suction head = α in 1/kPa × 2.99. Lu and Likos's representative infiltration rate is about 2.7 mm/day (0.11 in./day) and evaporation 1 mm/day.

With no flow the suction equals the height above the water table, which is the hydrostatic case. The solution also has a physical limit: steady infiltration cannot exceed ks, and when it reaches ks the suction falls to zero throughout. As a check, Lu and Likos's representative clay (ks = 0.014 ft/day, or 5 × 10−8 m/s; α = 0.015 per ft of suction head, or 0.005 kPa−1) under their highest infiltration rate gives about 650 psf (31 kPa) of suction 33 ft (10 m) above the water table, against 2,050 psf (98 kPa) with no flow. That is a change of roughly 1,360 psf (65 kPa), consistent with the “about 60 kPa” (1,250 psf) they describe for that case.

6.4.11.2 Worked example

A 1.5H:1V (33.7°) silt slope with φ′ = 32°, no cohesion and the water table 15 ft down is checked at a slip depth of 4 ft. Without suction its factor of safety would be 0.94, so it should not stand. With no flow, suction raises it to 2.88. Steady infiltration of 0.1 in./day lowers that to 2.27, and 0.25 in./day to 1.39. Once infiltration matches the silt's conductivity, the slope is back to 0.94 and fails. Drainage cannot help here because there is no water table at the slip depth. What helps is limiting infiltration (ditches above the crest, sealing cracks, vegetation) or flattening the slope.

Suction is real strength, but it is weather-dependent. Use it to explain why a slope has stood, never to justify a slope steeper than φ′ for design. Check the case with suction removed, and with the water table at its wet-season level, before relying on any steep cut or fill along track.

Open the rainfall and suction calculator →
Steady suction and effective saturation profiles above the water table for a given infiltration or evaporation rate, and the infinite-slope factor of safety with depth, with and without suction.

6.4.11.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.

  • N. Lu and W.J. Likos, Unsaturated Soil Mechanics: Chapter 7, steady suction profiles (Eqs. 7.4 and 7.5), van Genuchten effective saturation (Eq. 7.11), the effective stress parameter (Eqs. 7.15 and 7.16), and Tables 7.1 and 7.2Find source ↗
  • J.M. Duncan, S.G. Wright and T.L. Brandon, Soil Strength and Slope Stability, 2nd edition: infinite slope analysis and shallow slidesFind source ↗
  • B.M. Das, Principles of Geotechnical Engineering, 7th edition: effective stress in partially saturated soilFind source ↗
6.4.12 Seasonal Pore Pressure in Clay-Fill Embankments

Section 6.4.11 treats suction above a water table under steady infiltration. Old clay embankments add a seasonal cycle: in summer, vegetation dries the fill and suctions develop; in winter the fill wets up and pore pressure can become positive at depth. Monitoring and modelling of UK railway embankments show that pore pressure in these fills is seldom hydrostatic below a thin near-surface layer, and that the steady-state, saturated assumption usually made in embankment assessments is unreliable (O'Brien, 2013, pp. 19, 29–30).

Permeability controls the winter peak

Table 6.4-11. Measured permeability of dumped clay fill (saturated values)
Zone and testk (m/s)k (ft/day)
Clay fill below about 6.5 ft (2 m), variable-head borehole tests2 × 10−9 to 5 × 10−80.0006 to 0.014
Fill affected by silt and sand lenses10−7 to 5 × 10−60.03 to 1.4
Slope surface, Guelph permeameter (near field saturation)10−6 to 10−50.3 to 2.8

O'Brien (2013), Fig. 11 and p. 25. The borehole values are one to two orders of magnitude higher than for intact stiff fissured clay because of the clod–matrix fabric.

Three zones control the pore pressure: the near-surface fill, which is cracked and more permeable; the main body of clay fill; and the foundation soil. Modelling gave a critical intermediate range of fill permeability of about 5 × 10−8 to 5 × 10−7 m/s (0.014 to 0.14 ft/day): in that range most daily winter rainfall infiltrates and pore pressure rises quickly, so a run of moderately wet days can produce a higher winter pore pressure than one storm. Fill of about 10−9 m/s (0.0003 ft/day) or less responded too slowly to be at risk (O'Brien, 2013, pp. 25, 27). Small, steep embankments developed lower pore pressures than larger, flatter ones in the same models.

Equations for unsaturated flow and strength

Equation 6.4-8. Relative hydraulic conductivity (Mualem–van Genuchten)

k(Se) = ks Se0.5 [1 − (1 − Se1/m)m]2,   m = 1 − 1/n,   Se from Equation 6.4-7

van Genuchten (1980). The UK embankment models fitted van Genuchten parameters to a modified Croney water retention curve with a lower air-entry value, to represent the clod–matrix fill (O'Brien, 2013, Appendix).

Equation 6.4-9. Shear strength of unsaturated soil (extended Mohr–Coulomb)

τ = c′ + (σ − ua) tanφ′ + (ua − uw) tanφb

Fredlund, Morgenstern and Widger (1978). φb is the friction angle for suction; the Bishop form used in Section 6.4.11 is the special case tanφb = Se tanφ′.

Two cautions from the same work. Conductivity is lower on wetting than on drying at the same suction (hysteresis), which changes how fast a slope wets up; and reliable field values of unsaturated permeability for dumped fills are scarce, so modelled pore pressures are a guide to patterns, not predictions.

A few standpipe piezometers read for a few months will not find the winter peak in a clay embankment. Read pore pressure and suction through at least one full dry and wet season (Chapter 5.3, Section 5.3.20), and use the wettest period on record, not the monitoring period, when choosing design pore pressures.

Open the rainfall and suction calculator →
Steady suction profile, effective saturation and infinite-slope factor of safety with depth, now with an optional root cohesion zone.

Sources

Paraphrased from the published sources below; values are converted to English units. Individual railroads, clients and projects are not named.

  • O'Brien, A. S. (2013). The assessment of old railway embankments – time for a change? In Gallipoli (ed.), Partial Saturation in Compacted Soils, pp. 19–32. ICE PublishingFind source ↗
  • van Genuchten, M. T. (1980). A closed-form equation for predicting the hydraulic conductivity of unsaturated soils. Soil Sci. Soc. Am. J. 44, 892–898Find source ↗
  • Fredlund, D. G., Morgenstern, N. R. and Widger, R. A. (1978). The shear strength of unsaturated soils. Can. Geotech. J. 15(3), 313–321Find source ↗
← Previous · 6.0 Analysis Chapter 6.3 — Slope Stability Analysis