6.1.2 Shallow Foundation Bearing Capacity — Vesić General Equation

Foundation bearing capacity governs the structural adequacy of every load-transfer element in railroad infrastructure — bridge abutments and piers, signal equipment…
Authors: Daniel P. Colwell and Mario Ruel
6.1.2 Shallow Foundation Bearing Capacity — Vesić General Equation
6.1.2.1 General Bearing Capacity Equation

The Vesić (1973) generalization of Terzaghi's original equation is the standard for computing ultimate unit bearing capacity q_ult for shallow foundations:

Bearing Capacity
Bearing Capacity
Bearing Capacity Determination
Bearing Capacity Determination
Safe Bearing Capacity (SBC) Calculation
Safe Bearing Capacity (SBC) Calculation
Equation 6.1-1 — Vesić General Bearing Capacity:

q_ult = c · Nc · Fcs · Fcd · Fci

+ q · Nq · Fqs · Fqd · Fqi

+ 0.5 · γ · B · Nγ · Fγs · Fγd · Fγi

Where:

  • c = cohesion intercept (psf)
  • q = effective overburden pressure at footing base = γ · D_f (psf); D_f = embedment depth (ft)
  • γ = effective unit weight of soil below footing base (pcf)
  • B = footing width (ft)
  • N_c, N_q, N_γ = dimensionless bearing capacity factors (function of φ')
  • F_cs, F_qs, F_γs = shape correction factors
  • F_cd, F_qd, F_γd = depth correction factors
  • F_ci, F_qi, F_γi = inclination correction factors
Inputs: where each value comes from (5)
SymbolWhat it isComes fromHow to get itTypical range
ccohesion intercept (psf)Lab testEffective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more.0–300 psf · by USCS group
qeffective overburden pressure at footing base = γ · D_f (psf)Another equationFrom unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level.project-specific
Dfembedment depth (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
γeffective unit weight of soil below footing base (pcf)Lab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group
Bfooting width (ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Equation 6.1-2 — Bearing Capacity Factors (Vesić):

Nq = e^(π·tan φ') · tan²(45 + φ'/2)

Nc = (Nq − 1) · cot φ' (use Nc = 5.14 when φ' = 0)

Nγ = 2(Nq + 1) · tan φ'

Table 6.1-1 — Bearing Capacity Factors vs. Friction Angle
φ' (°)N_cN_qN_γTypical Soil Description
05.141.000.00Soft–medium clay (UU condition)
56.491.570.45Soft clay with minor sand
108.352.471.22Silty clay
1510.983.942.65Stiff clayey silt
2014.836.405.39Dense silt, loose sand
2520.7210.6610.88Medium-dense sand
3030.1418.4022.40Dense sand, gravel-sand
3546.1233.3048.03Dense gravel
4075.3164.20109.4Very dense gravel
45133.9134.9271.8Dense rock fill
Inputs: where each value comes from (4)
SymbolWhat it isComes fromHow to get itTypical range
Nqintermediate value computed on this pageAnother equationComputed: Nq = e^(π·tan φ') · tan²(45 + φ'/2)project-specific
Ncintermediate value computed on this pageAnother equationComputed: Nc = (Nq − 1) · cot φ' (use Nc = 5.14 when φ' = 0)project-specific
φ'effective friction angleLab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
γtotal (moist) unit weightLab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group
6.1.2.2 Shape Correction Factors

For a rectangular footing of width B and length L (L ≥ B):

Equation 6.1-3 — Shape Factors:

Fcs = 1 + (B/L)(Nq/Nc)

Fqs = 1 + (B/L) tan φ'

Fγs = 1 − 0.4(B/L)

For a strip footing: B/L → 0, so F_cs = F_qs = F_γs = 1.0. For a circular footing (B = L): B/L = 1.0.

Inputs: where each value comes from (5)
SymbolWhat it isComes fromHow to get itTypical range
Fcsintermediate value computed on this pageAnother equationComputed: Fcs = 1 + (B/L)(Nq/Nc)project-specific
Fqsintermediate value computed on this pageAnother equationComputed: Fqs = 1 + (B/L) tan φ'project-specific
Fγsintermediate value computed on this pageAnother equationComputed: Fγs = 1 − 0.4(B/L)project-specific
φ'effective friction angleLab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
γtotal (moist) unit weightLab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group
6.1.2.3 Depth Correction Factors

No additional content.

Equation 6.1-4 — Depth Factors (Df/B ≤ 1):

Fcd = 1 + 0.4(Df/B)

Fqd = 1 + 2·tan φ'·(1 − sin φ')²·(Df/B)

Fγd = 1.0

For D_f/B > 1, replace D_f/B with arctan(D_f/B) in radians in the F_qd expression.

Inputs: where each value comes from (1)
SymbolWhat it isComes fromHow to get itTypical range
φ'effective friction angleLab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
6.1.2.4 Inclination Correction Factors

For a resultant load inclined at angle β from vertical (due to braking or wind forces):

Equation 6.1-5 — Inclination Factors:

Fci = Fqi = (1 − β/90)²

Fγi = (1 − β/φ')²

β is in degrees. For purely vertical loading, β = 0 and all inclination factors = 1.0.

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
φ'effective friction angleLab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
γtotal (moist) unit weightLab testWeigh and measure undisturbed tube samples (ASTM D7263); for fill, use the compaction spec. Or compute γ = γd(1 + w).sands 105–135, clays 95–130 pcf · by USCS group
6.1.2.5 Allowable Bearing Capacity

No additional content.

Equation 6.1-6 — Allowable Bearing Pressure:

q_allow = (q_ult − q) / FS + q

Where q = surcharge at footing base; FS = factor of safety (typically 3.0 for railroad structures with limited investigation; 2.5 with comprehensive investigation).

The net allowable bearing pressure is:

q_net,allow = (q_ult − q) / FS

For railroad bridge abutments, FS ≥ 3.0 is common practice. For yard and siding structures, FS = 2.5 may be acceptable with borings at every foundation location; confirm with the owner railroad.

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
qsurcharge at footing baseLoading criteriaFrom the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications.project-specific
FSfactor of safety (typically 3.0 for railroad structures with limited investigationDesign criterionSet by the owner railroad's standards, AREMA, AASHTO, USACE or the project specification.typically 3.0 for railroad structures with limited investigation
Supplemental reference

Two special cases common on railroad property

Strong layer over weak layer. A compacted ballast/subballast section or desiccated crust over soft clay is the typical railroad profile, and the Vesić equation (which assumes one homogeneous soil) overestimates capacity there. Das presents the Meyerhof and Hanna (1978) method: when the strong layer thickness H is small relative to B, the footing punches through the top layer (resisted by adhesion and passive force on vertical planes below the footing edges) and then fails the lower layer in general shear:

qu = qb + 2(Ca + Pp sin δ′)/B − γ1H  ≤  qt (capacity of the top layer alone)

where qb is the bearing capacity of the weaker layer and Ca = c′aH is the adhesion force. If H is large, the failure surface stays in the top layer and qt governs. For signal and equipment foundations on a thin working platform over soft subgrade, check this mechanism.

Footing at the top of a slope. Signal masts, catenary poles and bridge abutments often sit on or near an embankment crest. Meyerhof (1957) gives qu = c′Ncq + ½γBNγq, with Ncq and Nγq charted against slope angle, footing setback b/B, embedment Df/B and, for clay, the stability number Ns = γH/cu. Capacity increases with setback distance (Das charts b/B from 0 to about 6); a footing right at the crest can have a small fraction of its level-ground capacity. A worked example, footings on the slope face and poles in slopes are in Section 6.1.23. Always follow with a global slope stability check (Chapter 6.3).

Source: Das, B. M. Principles of Foundation Engineering. Cengage Learning

Supplemental reference

Presumptive allowable bearing pressures for preliminary sizing

For signal houses, small culvert headwalls and other minor railroad structures — or to sanity-check a Vesić result — NAVFAC DM-7.02 (Table 1) gives presumptive allowable pressures intended to provide adequate safety against failure and avoid detrimental settlement of individual footings:

Table 11-S1. Presumptive allowable bearing pressure, tsf (NAVFAC DM-7.02, Table 1, abridged)

Bearing materialConsistencyRangeRecommended
Massive crystalline igneous/metamorphic rock (granite, basalt, gneiss)Hard, sound60–10080
Foliated metamorphic rock (slate, schist)Medium hard, sound30–4035
Hard cemented shale, siltstone, sandstone, limestone without cavitiesMedium hard, sound15–2520
Weathered or broken bedrock (RQD < 25), except argillaceousSoft rock8–1210
Compaction shale / argillaceous rock, soundSoft rock8–1210
Glacial till, hardpan (GW-GC, GC, SC)Very compact8–1210
Gravel, gravel–sand (GW, GP, SW, SP)Very compact / medium / loose6–10 / 4–7 / 2–67 / 5 / 3
Coarse to medium sand (SW, SP)Very compact / medium / loose4–6 / 2–4 / 1–34 / 3 / 1.5
Fine to medium sand, silty or clayey sand (SW, SM, SC)Very compact / medium / loose3–5 / 2–4 / 1–23 / 2.5 / 1.5
Inorganic clay (CL, CH)Very stiff–hard / medium–stiff / soft3–6 / 1–3 / 0.5–14 / 2 / 0.5
Inorganic silt, varved silt-clay-fine sandVery stiff–hard / medium–stiff / soft2–4 / 1–3 / 0.5–13 / 1.5 / 0.5

NAVFAC’s notes matter for railroad use: controlled compacted fill takes the value of the equivalent natural soil; organic soil and uncompacted fill (common in old railroad embankments) must be investigated case by case; on compressible fine-grained soil, settlement generally governs; and a rock value may never exceed the intact UCS. Transient wind or earthquake loads may increase the pressure by up to one-third. Presumptive values are not a substitute for analysis where differential settlement matters, soils are soft, or groundwater is shallow.

Source: Naval Facilities Engineering Command (1986). Foundations and Earth Structures, Design Manual 7.02 (NAVFAC DM-7.02)

Foundation Design
Foundation Design
Supplemental reference

Footings on rock: failure mode depends on the joints

USACE EM 1110-1-2908 notes that rock foundation design is usually controlled by settlement, sliding or overturning, but bearing must still be checked, and the failure mode depends on joint spacing S relative to footing width B, joint orientation and condition (Figure 11-S1):

Typical bearing capacity failure modes for foundations on intact, jointed, layered and fractured rock (modified from Sowers, 1979, and Kulhawy &amp; Goodman, 1980).
Supplemental Figure 11-S1. Typical bearing capacity failure modes for foundations on intact, jointed, layered and fractured rock (modified from Sowers, 1979, and Kulhawy & Goodman, 1980). Source: U.S. Army Corps of Engineers (1994). Rock Foundations. EM 1110-1-2908, p. 6-2.
  • Intact rock (S > 4–5B): local shear in brittle rock (slip surfaces stay in the rock) or general wedge failure in ductile rock.
  • Steep, closely spaced, open joints: columns fail in unconfined compression — qult = 2c·tan(45° + φ/2), i.e., roughly the rock-mass UCS.
  • Steep, closely spaced, tight joints: general shear.
  • Steep joints spaced wider than B: splitting that progresses to general shear.
  • Joints dipping 20–70°: general shear, with a joint likely forming one face of the wedge.
  • Layered or fractured rock: punching or flexure of a stiff layer over a weak one, or general shear of a heavily fractured mass treated like soil.

For non-strip footings EM 1110-1-2908 applies Sowers’ shape corrections: Nc × 1.2 (circular), 1.25 (square), 1.12 (L/B = 2), 1.05 (L/B = 5); Nγ × 0.70, 0.85, 0.90, 0.95 respectively. Because rock masses usually have a large margin, USACE recommends starting from lower-bound c and φ.

Source: U.S. Army Corps of Engineers (1994). Rock Foundations. EM 1110-1-2908

6.1.2.6 Vesic Bearing Capacity Method and Calculator

The USACE manual Bearing Capacity of Soils (EM 1110-1-1905) sets out the general bearing capacity equation with the Terzaghi, Meyerhof, Hansen and Vesic factor sets and works each through the same footing. The Vesic set is used here because it handles footing shape, embedment and inclined load in one consistent form and is the basis of many agency programs. Track structures add two things to the usual building problem: longitudinal braking and traction forces make the load inclined, and the manual's table of typical factors of safety lists 4 for railway bridges, against 3 for ordinary footings.

6.1.2.6.1 Method

Equation 6.1-20. General bearing capacity equation (EM 1110-1-1905, Eq. 4-1)

qu = c Nc ζc + σ'D Nq ζq + 0.5 B γ'H Nγ ζγ

where σ'D is the effective overburden at the footing base, γ'H the effective unit weight within a depth B below the base, and each ζ the product of shape, depth and inclination factors.

Equation 6.1-21. Vesic bearing capacity factors

Nq = eπ tanφ tan²(45° + φ/2)   Nc = (Nq − 1) cotφ   Nγ = 2(Nq + 1) tanφ
Table 6.1-4. Vesic correction factors used by the calculator (EM 1110-1-1905, Table 4-6)
EffectCohesion ζcSurcharge ζqWedge ζγ
Shape1 + (B/W)(Nq/Nc)1 + (B/W) tanφ1 − 0.4 B/W
Depth (k = D/B, or tan−1(D/B) when D/B > 1)ζqd − (1 − ζqd)/(Nc tanφ); 1 + 0.4k for φ = 01 + 2 tanφ (1 − sinφ)² k1
Inclination (m = (2 + B/W)/(1 + B/W))ζqi − (1 − ζqi)/(Nc tanφ)(1 − T/Q)m(1 − T/Q)m+1

The calculator reproduces the manual's Vesic worked example (B = 3 ft, W = 6 ft, D = 2 ft, φ' = 30°, T/Q = 0.2): qu = 5.86 ksf.

Groundwater is handled as the manual recommends: σ'D uses buoyant weight below the water table, and γ'H is interpolated between moist and buoyant weight when the water table lies within B below the base. In loose or soft soil the local-shear option reduces tanφ by one third, which gives the lower-bound estimate of the manual's Equation 4-9.

6.1.2.6.2 Worked example: railroad bridge abutment footing

Table 6.1-5. Abutment footing on medium dense sand (calculator output)
InputValueResultValue
Footing B × W, embedment D8 ft × 30 ft, 4 ftNc, Nq, Nγ35.49, 23.18, 30.21
φ', c32°, 0Correction factors ζc, ζq, ζγ1.102, 1.100, 0.666
γ, γsat, water depth125 pcf, 130 pcf, 6 ftUltimate qu19.34 ksf
T/Q (longitudinal braking)0.10Allowable qa at FS 4 (railway bridge)4.83 ksf
Factor of safety4Allowable vertical load1,160.2 kips

The inclination factor alone removes roughly a fifth of the surcharge and wedge terms in this example, which is why longitudinal forces from braking and traction should be carried into the bearing check rather than treated only in the structural design. Settlement (Chapter 6.2) usually controls for footings wider than about 6 ft on sand.

Open the bearing capacity calculator →
Vesic method per EM 1110-1-1905: footing shape, embedment, inclined load, water table, local shear, and allowable pressure for a chosen factor of safety.

6.1.2.6.3 Sources in the library

These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.

  • Bearing Capacity of Soils, USACE EM 1110-1-1905 (1992), Bearing Capacity folder: general equation, Vesic factors, groundwater, factor of safety table and worked examples.Find source ↗Library entry
  • Bearing Capacity of Soils — Shallow Foundations and — Piled Foundations (course notes), Bearing Capacity folder.Find source ↗Library entry
  • Pile Design for Structural and Geotechnical Engineers (book): deep foundations, used where D/B exceeds the shallow range.Find source ↗
← Previous · 5.0 Testing Chapter 5.5 — The Observational Method and Trigger-Action Response Plans
Next · 6.0 Analysis → Chapter 6.2 — Settlement Analysis