Table 6.1-2 — Typical Bearing Capacity Values by Soil Type (English Units)| Soil Type (USCS) | Consistency/Density | s_u or φ' | q_allow Shallow Fdn (tsf) | Railroad Application |
|---|
| CH (Fat Clay) | Very soft | s_u = 250–500 psf | 0.25–0.50 | Avoid; use piles — Class I railroad located in coastal Georgia |
| CL (Lean Clay) | Soft | s_u = 500–1,000 psf | 0.5–1.0 | Siding footings minimum 3 ft embed. |
| CL | Stiff | s_u = 1,000–2,000 psf | 1.0–2.0 | Bridge abutment footings — a Class I railroad |
| CL/ML | Very stiff | s_u = 2,000–4,000 psf | 2.0–4.0 | Grade crossing slabs — a short-line railroad |
| SM (Silty Sand) | Loose | φ' = 28–32° | 1.0–1.5 | Use piles for bridge loads — a Class I railroad |
| SP (Poorly Graded Sand) | Medium dense | φ' = 32–36° | 1.5–2.5 | Signal foundations — a Class I railroad |
| SW/GW | Dense | φ' = 36–40° | 2.5–4.5 | Intermodal crane footings — a Class I railroad |
| GW (Well-graded Gravel) | Very dense | φ' = 40–45° | 4.5–7.0 | Mainline bridge piers — a Class I railroad |
| CL over bedrock | Stiff clay cap | Mixed | 1.5–3.0 w/ piles to rock | Class I railroad located in Appalachia |
| Limestone/Sandstone | Competent rock | RQD > 50% | 10–50+ | A Class I railroad bridge piers |
Table 6.1-3 — Pile Type Selection Guide| Client | Preferred Pile Type | Minimum FS (w/test) | Minimum FS (no test) | Wave Equation Required | Load Test Required |
|---|
| FRA (all classes) | Per AREMA Ch. 8 | 2.5 min | 3.0 min | As applicable | Per client |
Owner railroads may set different values. Confirm them against the owner railroad's current standards when the work is scoped.