When piles are installed in a group, the group capacity may be less than the sum of individual pile capacities due to stress overlap. The group efficiency factor η is:

η = 1 − θ · [(n−1)·m + (m−1)·n] / (90 · m · n)
Where:
Common practice (see AREMA MRE Chapter 8 for piles) uses a center-to-center spacing of at least about 2.5–3 pile diameters. At S = 3D, common for railroad bridge pile groups, η ≈ 0.72–0.82.
For cohesive soils, the block failure mode must also be checked: the lesser of the group efficiency method and the block failure capacity controls.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| θ | arctan(D/S) in degrees | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| D | pile diameter (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| S | center-to-center spacing (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| m | number of columns | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| n | number of rows | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
Q_block = 2·D_g·(B_g + L_g)·su,avg + Nc·su,tip·B_g·L_g
Where:
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Dg | pile group embedment depth (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| Nc | 5(1 + 0.2D_g/B_g)(1 + 0.2B_g/L_g) ≤ 9 (Skempton) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| su | undrained shear strength | Lab or field test | Lab: UU triaxial (ASTM D2850) or unconfined compression (D2166). Field: vane shear (D2573), CPT su = (qt − σv)/Nkt, or pocket penetrometer/Torvane for screening. | soft 250–500, stiff 1,000–2,000 psf · by USCS group |