↑ Parent Menu⌂ Main Menu
← Chapter 6.1 Foundation Engineering: Bearing Capacity
GHRM
Railway Ground Hazard Risk Management · 6.0 · Analysis
Sections · click a car to open it

Empirical Equations — Use and Limitations

Foundation bearing capacity governs the structural adequacy of every load-transfer element in railroad infrastructure — bridge abutments and piers, signal equipment…
Authors: Daniel P. Colwell and Mario Ruel
Empirical Equations — Use and Limitations

The correlations used in this chapter are listed below. Each gives an estimate, not a test result. The full equation, variables, range of applicability, constraints and source for each one, and the note to record whenever one is used, are in the Empirical Equations & Correlations reference.

IDCorrelationGives
IS-01SPT energy & procedure correctionN₆₀
IS-04Friction angle of sand from SPT (Schmertmann form)φ'
IS-05Friction angle of sand from SPT (Peck–Hanson–Thornburn)φ'
IS-06Friction angle of sand from SPT (Hatanaka & Uchida)φ'
IS-07Undrained shear strength of clay from SPTSᵤ
IS-14Undrained shear strength from CPTSᵤ
IS-15Friction angle of sand from CPTφ'
RK-07Generalized Hoek–Brown criterionm_b, s, a
← Previous · 5.0 Testing Chapter 5.5 — The Observational Method and Trigger-Action Response Plans
Next · 6.0 Analysis → Chapter 6.2 — Settlement Analysis