6.3.7 Cut Slope Design in Rock

Slope stability governs the design of railroad embankments, cut slopes, and side-hill fills across railroad networks.
Authors: Daniel P. Colwell and Mario Ruel
6.3.7 Cut Slope Design in Rock

For rock cut slopes in Appalachia, Montana and Idaho, and the Rocky Mountains, kinematic analysis of joint and bedding plane orientations governs slope geometry over soil mechanics methods.

Equation 6.3-13 — Planar Rock Slide FS (Drained):

FS = (c'_j · A + (W·cos αp − U − V·sin αp) · tan φ'_j)

/ (W·sin αp + V·cos αp)

Where:

  • c'_j = joint cohesion (psf; often 0 for clean joints)
  • A = area of failure plane per unit width (ft²/ft)
  • W = weight of sliding block (lb/ft)
  • U = water uplift force on failure plane = 0.5 γ_w h_w A (lb/ft); h_w = water height in tension crack
  • V = water force in tension crack = 0.5 γ_w z_w² (lb/ft); z_w = water depth in crack
  • α_p = dip angle of failure plane (°)
  • φ'_j = joint friction angle (°)
Table 6.3-2 — Typical Rock Joint Strength Parameters for Railroad Cut Slopes
Rock Typec'_j (psf)φ'_j (°)Notes
Clean sandstone joint0–50028–35West Virginia and Montana cuts
Clay-filled shale parting0–2008–16Clay shale; use residual
Limestone bedding plane0–1,00032–40Gulf Coast carbonate
Granite exfoliation joint035–42Sierra Nevada
Weathered basalt0–50025–32Pacific Northwest

Kinematic feasibility of planar, wedge, and toppling failure must be evaluated by stereographic projection (stereonet analysis) using joint orientation data collected during field mapping. This analysis is summarized below and should be performed for every rock cut slope.

Inputs: where each value comes from (9)
SymbolWhat it isComes fromHow to get itTypical range
c'jjoint cohesion (psfLab testEffective cohesion intercept from the same triaxial or direct-shear tests used for φ'. Take c' = 0 for sands and for long-term design unless tests justify more.0–300 psf · by USCS group
Aarea of failure plane per unit width (ft²/ft)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Wweight of sliding block (lb/ft)Another equationArea of the slice, wedge or wall section from the cross-section geometry × unit weight γ (from lab tests).project-specific
Uwater uplift force on failure plane = 0.5 γ_w h_w A (lb/ft)Loading criteriaFrom the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications.project-specific
hwwater height in tension crackField measurementGroundwater level from boring logs, observation wells or piezometers (ASTM D5092 / D4750); design with the seasonal high level.project-specific
Vwater force in tension crack = 0.5 γ_w z_w² (lb/ft)Loading criteriaFrom the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications.project-specific
zwwater depth in crackField measurementGroundwater level from boring logs, observation wells or piezometers (ASTM D5092 / D4750); design with the seasonal high level.project-specific
αpdip angle of failure plane (°)Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
φ'jjoint friction angle (°)Lab test (or correlation)Triaxial CU with pore pressure (ASTM D4767) or CD (D7181), or direct shear (D3080). Sands are rarely sampled: estimate from SPT or CPT correlations (IS-04, IS-05, IS-08).sands 30–42°, clays 17–32° · by USCS group
Supplemental reference

Kinematic screening before stability analysis

Section 6.3.7 leaves stereonet analysis out of scope. The screening rules are short enough to apply to every railroad rock cut. Following Wyllie and Mah (2004), with face dip ψf and dip direction αf:

  • Planar sliding is possible when the plane daylights (ψp < ψf), dips more steeply than its friction angle (ψp > φj), and its dip direction is within about ±20° of the face. Outside ±20°, intact rock at one end of the block provides enough restraint.
  • Wedge sliding is possible when the line of intersection daylights (ψi < ψf) and plunges more steeply than φ. Its daylight envelope is wider than that for planes because two planes provide release.
  • Toppling requires steep planes dipping into the face, striking within about 10° of it, and satisfying (90° − ψf) + φj < ψp (Goodman and Bray, 1976).
  • The friction cone (radius φ) plotted on the same stereonet gives a first stability check for gravity loading only. It ignores water pressure and bolt forces, so kinematically possible blocks then go to the limit-equilibrium analysis of Eq. 6.3-13.

Wyllie and Mah note it is rarely possible to change an alignment enough to avoid an adverse structure; the choice is usually to flatten that face or reinforce it.

Why rock falls happen on transportation corridors

A California study of 308 highway rock falls (McCauley et al., 1985, reported by Wyllie and Mah) found that water-related causes account for 68% (rain 30%, freeze–thaw 21%, snowmelt 8%, channeled runoff 7%, plus differential erosion, springs and tree roots), and 85% when adverse geology is added. On a major western Canadian railroad, about 70% of 25 years of recorded falls occurred in winter, and falls smaller than about 1.3 yd³ occurred up to 50 times a year, while 13,100 yd³ slides recurred every 10–50 years. Many railroad cuts were blasted more than a century ago with techniques that damaged the rock, and have since weathered. Schedule scaling and inspection for late fall and early spring, and treat drainage as a primary rock-fall control.

Figure 6.3-16. Scaling crew on a cliff above the right-of-way.
Figure 6.3-16. Scaling crew on a cliff above the right-of-way.

Source: Wyllie, D. C. and Mah, C. W. (2004). Rock Slope Engineering: Civil and Mining, 4th ed. Spon Press

Supplemental reference

Surface support: high-tensile mesh and grouted reinforcement

Active high-tensile mesh. Draped mesh only guides falling rock to the ditch; a pretensioned mesh pinned with a grid of soil or rock nails actively holds the surface layer. The Geobrugg TECCO system (presented at the Appalachian geohazards conference) uses wire of more than 256 ksi, giving mesh tensile strength of about 10.2 kips/ft, compared with about 3 kips/ft for common steel wire mesh and 2.75 kips/ft for a PET geogrid. The design (RUVOLUM concept) checks (1) sliding of the surface layer parallel to the slope and (2) local failure between nails, and sets the maximum nail spacing. It does not replace a global stability analysis (e.g., Bishop) of deeper surfaces. The presentation cites failed alternatives — shotcrete facing replaced after about 10 years and soft geogrid facing that failed by creep, cutting at sharp edges and overload.

Rock Bolt vs Soil Nail
Rock Bolt vs Soil Nail
Figure 6.3-19. Rock mesh controlling raveling.
Figure 6.3-19. Rock mesh controlling raveling.
Figure 6.3-21. Slide-detector fence along a cutting.
Figure 6.3-21. Slide-detector fence along a cutting.

Load transfer in grouted bolts and cables. Wang, Hagan and Cao (2016) summarize laboratory work on fully grouted reinforcement:

  • Cable strands rarely rupture. Failure is more likely at the cable–grout interface (or the grout–rock interface), so capacity depends on load transfer, not steel strength. Modified strands (bulbed, indented) transfer load much better than plain strand because the geometry increases normal pressure at the interface.
  • Rebar bolts fail either by parallel shear on a cylindrical surface (smooth bars, closely spaced ribs, short embedment in stiff confinement) or by dilational slip on a conical surface. The optimum rib profile depends on grout properties and confining pressure.
  • Push tests overstate performance compared with pull tests (the bar expands under compression instead of necking). Verify bolt and anchor capacity with pull tests that load the bar in tension as in service.
Cable Anchoring of Rock Slopes
Cable Anchoring of Rock Slopes
Steel Cable Mesh on Slopes — Rockfall Protection
Steel Cable Mesh on Slopes — Rockfall Protection

Source: Amend, F. Slope Stabilization with High Tensile Wire Mesh. Geohazards in Transportation in the Appalachian Region Conference, Geobrugg North America · Wang, S., Hagan, P. C. and Cao, C. (2016). Advances in Rock-Support and Geotechnical Engineering. Butterworth-Heinemann

Rockfall Mitigation and Slope Stabilization
Rockfall Mitigation and Slope Stabilization

Rockfall management: stabilize, protect, warn

Table 6.3-6. Rock-slope management strategies and indicative costs
StrategyMethodsNotes
StabilizingDrainage, trimming, scaling, shotcrete, bolting; retaining walls; stabilizing berms; horizontal drainsHighest safety and reliability impact; cost varies; scaled-rock disposal can be a problem
ProtectingCatchment nets; barrier walls; lock blocks; rock sheds (~$1–10M); tunnels (~$3–50M); flumes (~$600K); rock mesh (~$100–250K)Nets for confined chutes and unscalable sources; keep catch ditches and wall accumulation zones clean
WarningSlide-detector fences; mercury and tip-over switches; temporary radio unitsA warning layer, not a fix: about 90% of trips prove passable; maintenance burden and false positives
Figure 6.3-17. A catchment net stopping a boulder.
Figure 6.3-17. A catchment net stopping a boulder.
Figure 6.3-18. Barrier wall at the base of a cliff.
Figure 6.3-18. Barrier wall at the base of a cliff.
Figure 6.3-20. Interlocking lock blocks with an uphill slide detector.
Figure 6.3-20. Interlocking lock blocks with an uphill slide detector.

One near-miss shows the limit of warning devices: the fence tripped as designed, but the train could not stop on the grade. Use engineering-grade concrete for lock blocks and source matching keys. Mark already-documented fallen rocks with an X.

After Geotechnology for Railroaders Program, Module 6.4; §02–04. Full reference under Supplemental References.

Supplemental reference · Blasting

Blasting and the Finished Cut Face

Production blasting breaks rock beyond the design line (overbreak), opens joints behind the face and loosens blocks. A blasted face therefore has lower effective joint strength and a higher long-term rockfall rate than the same rock cut by machine. Two controlled perimeter methods limit the damage:

  • Presplitting fires a row of closely spaced, lightly loaded holes along the final face before the production blast. The crack it forms stops the production blast from breaking past the line.
  • Cushion (trim) blasting fires the perimeter row after the production blast has been mucked out, against a free face.

A good controlled face shows half-barrels (half of each perimeter hole) along most of its height. Terrestrial laser scanning of each lift gives a difference model of the as-built face against the design. That shows overbreak and underbreak and lets the half-barrel count and the remaining catchment width be measured without anyone on the face (Feng, Wang and Röshoff, in Feng 2017).

In the Hoek-Brown criterion, blast damage enters through the disturbance factor D. Use D ≈ 0.7 for a well-controlled face and up to 1.0 for heavy production blasting. Example 2.7-5 in Chapter 2.7, Section 2.7.17 shows that D = 0.7 cuts the rock mass modulus to about a fifth of the intact value. Blast damage is limited to a zone near the face, so apply the reduced strength to that zone rather than to the whole slope.

For railroad work: Specify controlled perimeter blasting for every permanent cut face within rockfall reach of track. Typical specification items:
(1) a test section before production;
(2) perimeter-hole spacing and diameter shown on the blast plan;
(3) a face acceptance criterion, such as half-barrels visible over a set percentage of the face;
(4) scaling and inspection after each lift.
In stability checks for blasted faces, take joint cohesion as zero, use the disturbed-zone strength near the face, and plan scaling and bolting for the loosened zone. Overbreak narrows the catchment ditch, so check the as-built ditch width against the design after each lift. A face cut without perimeter control should carry a higher rockfall frequency rating until scaling and inspection show otherwise. Vibration limits and monitoring for blasting near track and structures are in Chapter 5.3, Section 5.3.27.

Source: Austin Powder Company (2002), glossary; FHWA (1991); Feng (ed.) (2017), Ch. 18. Summarized and paraphrased. Full references under S15, S16, S17.

Supplemental reference · Feng (ed.) (2017)

Testing Rock Bolts in Place

A standard pull test loads a bolt at the head until it holds the proof load or slips. For a fully grouted bolt it says little: the load is carried by the first foot or two of grout, so the test proves the head and the upper bond, not the anchorage along the bolt (Spearing et al., in Feng 2017). Two better tools are:

  • Short encapsulation pull test (SEPT): a test bolt is grouted over a short length only (about 12 in.) and pulled to failure. The grip factor is the load at slippage divided by the grouted length (lb per in.), and the anchorage stiffness is the slope of the load-displacement curve at about half the failure load.
  • Instrumented bolts: strain gauges in diametrically opposite slots along the bolt give the axial load profile during and after loading. Some gauges are lost when the bolt is spun into resin, so instrument extra bolts.

SEPTs repeated at 0, about 130 and about 190 to 270 days after installation in coal mine roofs found that the grip factor generally increased with time while the anchorage stiffness generally decreased (Chugh et al., in Feng 2017). A bolt that passes an early pull test can therefore become softer with time and allow more movement before it carries load.

For railroad work: Most railroad rock bolts and dowels are installed on cut faces and portals, are rarely retested, and sit in wet, freeze-thaw exposure. Specify proof testing of tensioned bolts. For fully grouted dowels, add SEPTs on sacrificial bolts in each rock type at installation, and repeat a few after a year or more where the bolts protect the track. Record the grip factor and stiffness as well as pass or fail. Include bolt heads, plates, grout cover and corrosion in the rock slope inspection cycle (Chapter 7.4), because a bolt that has lost its plate or rusted through its head no longer holds the block.

Source: Spearing, Kostecki and Jessu, “The needs and technologies for measuring the in situ performance of rock bolts,” Ch. 5; Chugh, Gurley and Bell, “Longer-term performance of grouted bolts in different lithologies in Illinois mines,” Ch. 8; in Feng (ed.) (2017). Summarized and paraphrased; units converted. Full reference under S17.

Tunnel portals: stability of portal faces and the slopes above tunnels, rockfall at portals and portal extensions are covered in Chapter 6.6, Section 6.6.6.

← Previous · 6.0 Analysis Chapter 6.2 — Settlement Analysis