Portals are where most tunnel incidents start. The rock and soil above a portal are usually weathered and loosened, the cut slopes were steepened to shorten the tunnel, and freeze-thaw and runoff are concentrated there. Typical problems are:
Common measures are scaling and bolting of the portal face, draped mesh or rockfall barriers, catchment ditches, drainage of the slope above, and portal extensions (canopies or rock sheds) that carry falling rock and snow over the track. Rock cut design and stabilization are covered in Chapter 6.3, Section 6.3.7, and the rockfall hazard rating for cuts in Section 3.8.29.
For railroad work: Rate each portal and its approach cuts with the rockfall hazard rating of Section 3.8.29 and include the slope above the portal in the slope inventory. After heavy rain, snowmelt or an earthquake, inspect the portals before the first train. Treat new diagonal cracks in a portal or movement of the portal face as a slope problem until shown otherwise.