Boring depth must be sufficient to characterize all soil and rock materials that will influence the performance of the planned structure or earthwork. Minimum boring depths for each project type are set by the applicable stress influence criterion, the structure geometry, and the owner railroad's requirements.
For footings and other structures, Das gives the ASCE (1972) rule: the minimum boring depth is the smaller of D1, where the stress increase falls to 10% of the applied pressure, and D2, where it falls to 5% of the effective overburden stress. The rule is for structures, not embankments (Section 3.9.5.3.3). Using the 2:1 stress distribution approximation:
Where:
Minimum boring depth condition (ASCE 1972, in Das):
Where σ'_v₀ is the effective overburden stress at depth z (psf), computed as:
with γ' = effective unit weight (pcf), typically 55–65 pcf (buoyant) below the water table, or 100–125 pcf (total) above it.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Q | total applied load (lb) | Loading criteria | From the loading criteria: AREMA MRE (Cooper E-80, impact), structural loads from the designer, or equipment specifications. | project-specific |
| B | footing width or embankment base width (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| L | footing length or embankment base length (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| z | depth below the base of the loaded area (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| σ'v0 | vertical stress / pore pressure = γ' × z | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
| γ' | buoyant unit weight | Another equation | γ' = γsat − γw (γw = 62.4 pcf). Use below the water table. | 50–75 pcf for most mineral soils · by USCS group |
For a square footing with total applied stress q (psf) over area B²:
D1 has a closed form for a square footing; D2 does not, because σ'v0 grows with z. The investigation planner (Section 3.9.5.3) solves both.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| γ' | buoyant unit weight | Another equation | γ' = γsat − γw (γw = 62.4 pcf). Use below the water table. | 50–75 pcf for most mineral soils · by USCS group |
| Project Type | Minimum Boring Depth (ft) | Source |
|---|---|---|
| Track subgrade, new or existing | 10 to 15 ft below proposed grade; stop at rock or 5 ft into dense or very stiff soil | Li and others (2016) |
| Embankment fill | 0.5 to 2 times the fill height below original ground, and through compressible soil | Das (2010); Look, Table 1.8 |
| Cut slope | Top of cut: to 5 ft below the proposed ditch flowline; toe: 16 ft or 10 ft into rock, whichever is shallower | A Class I railroad's public projects requirements; Look |
| Bridge, spread footing | About 2 B below the base, and the ASCE stress depth; Look gives 4 B to 5 B | A Class I railroad's bridge requirements; Das; Look |
| Bridge, piles or shafts | 10 ft below the estimated tip, or 10 pile diameters in competent strata | A Class I railroad's bridge requirements; Look |
| Bridge pier in a waterway | Below the estimated scour depth as well as the foundation criterion | Scour estimate (FHWA HEC-18 methods) |
| Retaining wall | About 2 to 2.5 times the retained height for a cantilever soldier pile wall; into rock or a firm layer | Practice |
| Culvert | 2 B to 4 B below the invert, and below compressible soil | Look, Table 1.8 |
| Slope failure investigation | Below the slide zone: as a guide 2 times the slope height or the width of the moving zone | Look, Table 1.8 |
| Rock coring | About 10 ft into rock to prove it is not a boulder | Look, Table 1.8 |
Values not supported by the sources in the library were removed in the November 2026 fact check (Table 3.9-8).
The railroad's bridge investigation requirements (Ruel, 2003) follow AREMA and add practical limits: borings extend below the depth significantly affected by the loads, river scour or deep shear — about twice the anticipated spread-footing width, or 10 ft below the estimated pile tip from a preliminary static analysis. One boring can be sufficient for a short bridge replacement in uniform, well-mapped geology; where practical, drill at the toe of the embankment rather than on the track. A railroad Bridges & Structures representative accompanies the crew.
The railroad also asks the geotechnical engineer for: allowable pile load vs. depth for each pile type (typical working load about 160 kips for a 14-in. H-pile), DRIVEN static capacity (compression and uplift), GRLWEAP driving criteria and maximum blows/in., p–y curves, and a linear lateral spring constant K per stratum for pile deflection up to about ½ in. at the bridge seat — so SPT, strength and unit-weight data must be sufficient for LPILE input in every stratum.
Table 5-S2. Guideline to extent of investigation (Look, 2007, Table 1.8, abridged)
| Development | Test spacing | Approximate depth |
|---|---|---|
| Bridges | Each pier | 4B–5B for shallow footings; 10 pile diameters in competent strata; in bedrock, ≥ 10 ft of coring and 3 pile diameters below founding level (RQD > 50%, moderately weathered or better) |
| Buildings | 65–165 ft | 2B–4B for pads/strips; 10 ft or 3 diameters below pile toe |
| Embankments | 80–165 ft at critical areas; 330–1,650 ft elsewhere | Beyond base of compressible alluvium at critical or suspect areas |
Source: Ruel, M. and KRK (2003). General Requirements for Geotechnical Investigations for the railroad's Bridge Construction Projects and “A Practical Approach to Lateral Loading on Piles for Railroad Bridge Design on Class I railroad Projects.” a Class I railroad · Look, B. G. (2007). Handbook of Geotechnical Investigation and Design Tables. Taylor & Francis
No single code fixes how many borings a railroad project needs or how deep they go. The criteria in the library come from four kinds of source, and they do not all agree: a Class I railroad's own requirements (public projects, bridge foundations and pipeline occupancy), a railway geotechnics text that ties boring spacing along the track to soil strength (Li and others), general investigation guides (Look's Table 1.8, USACE EM 1110-1-1804 Table 2-4 and a short course on site investigation), and the stress rule for structures given by Das. This section sets them side by side, fact-checks the spacing and depth values used elsewhere in this manual against them, and gives the planner that applies them. Use the railroad's requirement as the minimum, then tighten spacing and extend depth for the ground: weak, variable or suspect soil governs over any table.
| Feature | Spacing or number | Source |
|---|---|---|
| Track corridor (new siding, second main, extension) | One boring every 500 ft in high-strength soil, 200 ft in medium, 100 ft in low-strength soil | Li and others (2016), Table 8.1 |
| Existing line, cut and fill (public projects) | A series of three borings (on the track grade at the shoulder, at midslope, and in the ditch at the toe) about every quarter mile (1,320 ft), sited to represent the prevailing cut or fill | A Class I railroad's public projects requirements |
| Embankments | 80 to 165 ft at critical or suspect areas; 330 ft or more elsewhere, as for roads | Look, Table 1.8 |
| Cut slopes | 80 to 165 ft where H exceeds 16 ft; 165 to 330 ft where H is under 16 ft | Look, Table 1.8 |
| Landslide or slope failure | At least three borings or test pits along the critical section | Look, Table 1.8 |
| Bridges | At each pier and abutment; one boring can be enough for a short bridge in uniform, mapped geology | Look, Table 1.8; EM 1110-1-1804, Table 2-4; a Class I railroad's bridge requirements |
| Culverts | Under 66 ft long: one; 66 to 130 ft: one at each end; longer: each end and between, at most 66 ft apart. A boring at each end of a culvert to be extended | Look, Table 1.8; a Class I railroad's public projects requirements |
| Pipeline crossing under track | One on each side of the track on the pipe centerline, as close to the track as practicable | A Class I railroad's pipeline occupancy specification |
| Retaining walls | At each wall; 50 to 100 ft along the wall line | A Class I railroad's public projects requirements (at each wall); spacing is practice |
| Light towers, signal masts, catenary poles | At each foundation | Look, Table 1.8 (monopoles and towers) |
| Roads and yard pavement | One per 490 ft of centerline for a two-lane road (245 ft multilane); a grid over yards (practice) | EM 1110-1-1804, Table 2-4 |
Look's metric values are converted (25 m = 82 ft, rounded to 80; 50 m = 165 ft). Spacing tightens wherever the ground changes between borings, and test pits, probes or geophysics can fill the gaps.
| Feature | Minimum depth | Extend when | Source |
|---|---|---|---|
| Track subgrade | 10 to 15 ft below proposed grade | Poor soil is known or suspected; stop at rock or 5 ft into dense or very stiff soil | Li and others (2016) |
| Embankment | 0.5 to 2 times the embankment height below original ground; beyond the base of compressible soil at critical areas | Soft, organic or compressible soil continues | Das (2010); Look, Table 1.8 |
| Cut slope | Cut height to 5 ft below the proposed ditch flowline (top-of-cut boring); 16 ft below the toe or 10 ft into rock, whichever is shallower | Water-bearing or weak layers below the cut | A Class I railroad's public projects requirements; Look, Table 1.8 |
| Landslide | Below the slide zone: as a guide 2 times the slope height or the width of the moving zone, and 16 ft below the toe or 10 ft into rock | The slip surface is not found | Look, Table 1.8 |
| Bridge, spread footings | About 2 B below the base (1.5 B to 2 B); Look gives 4 B to 5 B for bridge footings | Compressible layers within the stress zone; scour depth | A Class I railroad's bridge requirements; short course; Look, Table 1.8 |
| Bridge, piles or shafts | 10 ft below the estimated tip; 10 pile diameters in competent strata | Weak layer below the tip | A Class I railroad's bridge requirements; Look, Table 1.8 |
| Rock | About 10 ft of core, to show that rock is not a boulder; for bridge piles, 3 diameters below founding level | Voids, clay seams or weathered zones | Look, Table 1.8 |
| Culvert | 2 B to 4 B below the invert (B = span), and below compressible soil | High fill over soft ground | Look, Table 1.8 |
| Pipeline crossing | Continuous sampling to 5 ft below the proposed invert; rock cored | – | A Class I railroad's pipeline occupancy specification |
| Light tower or pole | 15 ft for poles up to 66 ft high, rising to about 49 ft for 230 to 260 ft towers; less in hard ground, 30% more in soft | Loose sand or soft clay | Look, Table 1.8 |
| Road or yard pavement | 10 ft below finished grade (6.5 ft below formation in Look) | Organic or soft fill continues | EM 1110-1-1804, Table 2-4; Look, Table 1.8 |
Every boring that ends in soft, organic or loose soil, uncontrolled fill, or rock that could be a boulder is extended, whatever the table says.
For footings and other structures, Das gives the rule recommended by the American Society of Civil Engineers (1972). Find the depth D1 at which the stress increase from the structure falls to 10% of the applied pressure, and the depth D2 at which it falls to 5% of the effective overburden stress. The approximate minimum boring depth is the smaller of the two. The short course gives the same picture from elastic theory: under a square footing the stress increase is about 15% of the applied pressure at 1.5 B and 10% at 2 B, but under a long strip it is still 40% and 30% at those depths, so strips need deeper borings.
Equation 3.9-3. ASCE (1972) boring depth rule, with the 2:1 stress distribution
z is measured below the footing base; σ'v0 is the effective overburden stress at that depth, with the buoyant unit weight below the water table.
The rule was written for buildings and does not work for embankments. Under a strip as wide as a railroad fill, D1 is about 9 times the base width, which is why Das gives a separate range for embankments (one-half to two times the height) and why this manual no longer applies the stress check to fills.
| Check | Source | Planner |
|---|---|---|
| Square footing, depth where Δσ = 10% of q | About 2 B (short course, elastic); 2.16 B (2:1 closed form) | 2.17 B (B = 10 ft, D1 = 21.7 ft) |
| Long strip, depth where Δσ = 10% of q | Well beyond 2 B (short course: 30% at 2 B); 9 B (2:1 closed form) | 8.9 B |
| Track corridor in medium soil, 6,500 ft | One boring every 200 ft (Li and others) | 34 borings, 510 ft |
| Culvert 150 ft long | Each end and between, at most 66 ft apart (Look) | 4 borings |
| Pipeline crossing, invert 9 ft below the track | Each side, to 5 ft below the invert (a Class I railroad's specification) | 2 borings to 14 ft, rounded to 15 ft |
| Earlier value | Where | Published criterion | Now |
|---|---|---|---|
| Track subgrade borings every 500 to 1,000 ft | Table 3.3-2 | 100 to 500 ft by soil strength (Li and others); quarter-mile series as a railroad minimum | 100 to 500 ft; quarter-mile series as the floor |
| New sidings: 3 borings up to 5,000 ft; 1 per 2,500 ft beyond | Table 3.9-1 | As above | Spacing by soil strength |
| Embankment over 10 ft: 1.5 times the base width deep | Section 3.9.5.2 | 0.5 to 2 times the height (Das) | 0.5 to 2 H, through compressible soil |
| Depth where Δσ = 10% of σ'v0 | Section 3.9.5.1 | Smaller of D1 (10% of q) and D2 (5% of σ'v0), for structures only (ASCE, in Das) | Equation 3.9-3 |
| Culvert: one diameter below the invert | Table 3.3-3 | 2 B to 4 B below the invert (Look) | 2 B to 4 B |
| Rock core 5 to 10 ft | Table 3.3-3 | About 10 ft (Look) | 10 ft |
| Pile-supported abutment: 20 ft below the tip | Section 3.9.5.2 | 10 ft below the tip (a Class I railroad's bridge requirements); 10 pile diameters (Look) | 10 ft or 10 diameters |
Slope repair. A 600-ft embankment repair with 20-ft slopes in medium-strength soil, with the railroad's three-boring series (shoulder, midslope and toe) at each station. At the 165-ft spacing Look gives for critical areas the planner places 5 stations and 15 borings: the shoulder borings go through the fill and one fill height below original ground (40 ft), the midslope and toe borings to 30 ft. That is 500 ft of drilling, about 6.1 days at 90 ft/day including half a day to set up, and a standby allowance of 24.5 hr at 3.5 hr/day.
New siding. A 6,500-ft siding on medium-strength soil needs about 34 borings at 200-ft spacing, each 15 ft deep (510 ft). The railroad's quarter-mile series would give 6 stations and 18 borings; the soil-strength spacing governs here, and the railroad minimum governs only in strong, uniform ground.
Bridge footing. A 10-ft-square pier footing with its base 6 ft deep, bearing 4,000 psf, groundwater at 10 ft: D1 = 21.7 ft and D2 = 38.8 ft below the base, so the stress rule gives 21.7 ft. The railroad's 2 B gives 20 ft. The planner takes the deeper, 21.7 ft, and adds the 6-ft embedment: borings about 30 ft deep at each support.
Open the investigation planner calculator →
Boring number, spacing and depth for eleven railroad features from the published criteria above, the ASCE stress check for footings, soil and core footage, drilling days and train standby.
These documents are in the reference library. Summaries are paraphrased and metric values converted to English units. Individual railroads are not named.