↑ Parent Menu⌂ Main Menu
← Chapter 2.4 Silts: Properties, Typical Values and Liquefaction
GHRM
Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · click a car to open it

2.4.19 Subballast as a Filter over Silty Subgrade

Silt sits between sand and clay: too fine to drain freely, too coarse and too weakly plastic to hold together when wet. That combination makes it the soil most often behind track pumping, frost heave, piping, sloughing cut slopes, collapsing loess and liquefaction of fine-grained ground.
Author: Daniel P. Colwell
2.4.19 Subballast as a Filter over Silty Subgrade

Silts and fine sands under track pump: wet fines are worked up into the ballast under each axle, the ballast fouls, the track goes soft and the surface fails, as in the mud spring under a western main line described in one of the conference papers. The subballast layer is the defense. It must be graded so that the subgrade cannot wash up into it and the ballast cannot punch down into it, which is the filter rule used for earth dams. AREMA Chapter 1, Part 2, sets out the method: plot the subgrade gradation, apply the filter ratios to its D15 and D50 to get the allowable band for the subballast, then size the combined ballast and subballast thickness with Talbot's equation.

2.4.19.1 Filter ratios and thickness

Table 2.4-19. Requirements for filter material (AREMA Table 1-2-4, after USBR 1963)
Character of subballastR50 = D50 subballast / D50 subgradeR15 = D15 subballast / D15 subgrade
Uniform gradation (Cu 3 to 4)5 to 10–
Well to poorly graded, subrounded grains12 to 5812 to 40
Well to poorly graded, angular particles (crushed stone)9 to 306 to 18

Also: maximum subballast size not larger than the largest ballast particle; no more than 5% passing the No. 200 sieve; crushed stone with a uniformity coefficient not over 15. Where the subgrade can pipe, keep subballast D15 below 5 times subgrade D85 and use a well-graded subballast.

Equation 2.4-27. Ballast plus subballast depth (Talbot)

h = (16.8 pa / pc)4/5

pa = average pressure under the tie (psi), pc = allowable subgrade pressure including safety factor (psi), h in inches below the tie. AREMA keeps 12 in. of ballast below the tie so tamping does not reach the subballast; the rest of h is subballast.

2.4.19.2 Worked example: the AREMA silt subgrade

Table 2.4-20. Subgrade D15 = 0.046 mm, D50 = 0.24 mm; crushed-stone subballast (calculator output)
CheckResult
D50 band (9 to 30 × 0.24 mm)2.16 to 7.2 mm; subballast 4.75 mm
D15 band (6 to 18 × 0.046 mm)0.28 to 0.83 mm; subballast 0.675 mm
Uniformity coefficient14.2
Passing No. 2003.0 %
Ballast + subballast depth for pa = 55 psi, pc = 18 psi23.4 in.
Subballast thickness under 12 in. of ballast11.4 in.

The bands and the 23.4 in. depth match the AREMA example (Figure 1-2-5 and Article 3.10.2.3).

Most dense-graded aggregate base specifications fall near this band, but each source should be checked against the actual subgrade, because a silt with D15 near 0.01 mm needs a much finer subballast than a sandy silt. Where suitable subballast is not available, a geotextile separator can supplement it.

Open the subballast filter calculator →
AREMA filter ratios for D15 and D50, maximum size, fines, uniformity and piping checks, and the Talbot thickness of ballast plus subballast.

Example 2.4-6: Subballast Filter Over a Silt Subgrade

This is the AREMA example of Table 1.5-20, worked by hand. A subballast over silt must satisfy two filter ratios so the silt cannot pump up into it, and then the ballast plus subballast must be thick enough to bring the subgrade pressure down to its allowable value.

pa = 55 psi under tieBallast, 12 in. minimumSubballast: D15 0.675, D50 4.75 mm, Cu 14.2, 3% finesFits filter bands? Thickness = ?Silt subgrade: D15,s 0.046 mm, D50,s 0.24 mmpc = 18 psi allowableTotal depth = ?GivenSubgrade D15 0.046, D50 0.24 mmSubballast D15 0.675, D50 4.75 mmR50 9–30; R15 6–18 (angular)pa = 55 psi; pc = 18 psiBallast 12 in. minimumRequiredAllowable D50, D15 bands; fit?Total depth and subballastthicknessBlack = given; red = required
Given and required for Example 2.4-6.

Given

VariableValueDescription
D15,s, D50,s0.046 mm and 0.24 mmSubgrade gradation
SubballastCrushed stone: D15 = 0.675 mm, D50 = 4.75 mm, Cu = 14.2, 3.0% passing No. 200Proposed material
RatiosR50 9 to 30; R15 6 to 18Table 2.4-19, angular particles
pa55 psiAverage pressure under the tie
pc18 psiAllowable subgrade pressure including safety factor
Ballast12 in. below the tieAREMA minimum

Required

  • Allowable D50 and D15 bands and whether the subballast fits
  • Total depth and subballast thickness

Equations

  1. Eq. 1: D50 band = R50 × D50,s; D15 band = R15 × D15,s — Table 2.4-19
  2. Eq. 2.4-27 (Talbot): h = (16.8 pa / pc)4/5 — ballast plus subballast depth, inches

Steps

Step 1 · D50 band
9 × 0.24 to 30 × 0.24
2.16 to 7.2 mm; 4.75 mm fits
↓
Step 2 · D15 band
6 × 0.046 to 18 × 0.046
0.28 to 0.83 mm; 0.675 mm fits
↓
Step 3 · Other requirements
Cu = 14.2 ≤ 15; 3.0% ≤ 5% passing No. 200
Both met
↓
Step 4 · Depth (Eq. 2.4-27)
(16.8 × 55 / 18)0.8 = 51.30.8
h = 23.4 in.
Spot check: ln 51.3 = 3.94; 0.8 × 3.94 = 3.15; e3.15 = 23.4.
↓
Step 5 · Subballast thickness
23.4 − 12
11.4 in.
↓
Solution
Subballast meets both filter ratios; 23.4 in. total, 11.4 in. of it subballast.

Solution

The crushed stone fits both filter bands and the gradation limits. The ballast plus subballast must be 23.4 in. deep, so 11.4 in. of subballast goes under 12 in. of ballast.

The results match the AREMA example (Figure 1-2-5 and Article 3.10.2.3). The bands scale with the subgrade: a silt with D15 near 0.01 mm would need a much finer subballast than this sandy silt, so each source must be checked against the actual subgrade. Where suitable subballast is not available, a geotextile separator can supplement it.

2.4.19.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated limits are standard or published values. Individual railroads are not named.

  • AREMA Manual for Railway Engineering, Chapter 1 (2019 edition), Part 2, Section 2.11 Sub-ballast: design, Talbot thickness, filter requirements (Table 1-2-4) and example (Figure 1-2-5).Official page ↗
  • AREMA conference paper (2019): a mobile mud spring under a western Class I main line.Find source ↗
  • AREMA conference papers (2017): principles of drainage; effective maintenance solutions for chronic subgrade locations.Find source ↗
← Previous · 2.0 The Underworld Chapter 2.3 — Track Substructure: Ballast, Subballast and Subgrade
Next · 2.0 The Underworld → Chapter 2.5 — Clays: Properties, Typical Values and Behavior