Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · click a car to open it
2.4.13 Worked Examples
Silt sits between sand and clay: too fine to drain freely, too coarse and too weakly plastic to hold together when wet. That combination makes it the soil most often behind track pumping, frost heave, piping, sloughing cut slopes, collapsing loess and liquefaction of fine-grained ground.
The examples use generic sites and are not taken from any client project. Examples 2.4-1 to 2.4-3 follow one floodplain site from classification to the two kinds of seismic check that silts need; Examples 2.4-4 and 2.4-5 cover the two other silt problems most often met on railroads, frost and collapse. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution.
Example 2.4-1: Classification and Liquefaction Susceptibility of Floodplain Silts
A low embankment crosses a river floodplain in a seismic region, and two silt layers lie below the water table. Silts are where the two liquefaction screens disagree most often, so the first question for each layer is not whether it will liquefy but which kind of analysis it needs: a sand-like triggering analysis or a clay-like cyclic softening analysis.
Given and required for Example 2.4-1.
Given
Variable
Value
Description
Layer A
5 to 18 ft; LL = 31, PI = 6, w = 29%, fines = 78%
Upper silt
Layer B
18 to 30 ft; LL = 58, PI = 24, w = 45%, fines = 96%
Lower silt
Screen 1
Boulanger and Idriss: PI < 7 sand-like; otherwise clay-like
Section 2.4.8
Screen 2
Bray and Sancio: w/LL ≥ 0.85 and PI ≤ 12 susceptible; PI > 18 not susceptible
Section 2.4.8
Required
USCS group of each layer
Which liquefaction analysis each layer needs
Equations
Eq. 2.4-1: PIA = 0.73 (LL − 20) — A-line
Eq. 2: w / LL — Bray and Sancio water content ratio
Steps
Step 1 · Layer A: A-line
0.73 (31 − 20) = 8.0; PI = 6 < 8.0; LL < 50
ML; 22% coarse ≥ 15%: silt with sand
↓
Step 2 · Layer B: A-line
0.73 (58 − 20) = 27.7; PI = 24 < 27.7; LL ≥ 50
MH, elastic silt
↓
Step 3 · Boulanger and Idriss
A: PI = 6 < 7; B: PI = 24
A sand-like; B clay-like
↓
Step 4 · Bray and Sancio (Eq. 2)
A: 29 / 31 = 0.94 ≥ 0.85 and PI ≤ 12; B: 45 / 58 = 0.78 and PI > 18
A susceptible; B not susceptible
Spot check: The two screens agree for both layers, so there is no borderline call to make.
Layer A is ML (silt with sand) and sand-like: evaluate liquefaction triggering (Example 2.4-2). Layer B is MH (elastic silt) and clay-like: evaluate cyclic softening (Example 2.4-3).
Both layers are silts and both plot below the A-line, yet they behave differently in an earthquake. Layer A’s low plasticity and high water content let it build pore pressure and liquefy; Layer B’s plasticity makes it soften gradually instead. Choosing the wrong analysis is a common error with silts and can be unconservative either way.
Example 2.4-2: SPT Triggering in a Sandy Silt
Layer A of Example 2.4-1 screened as sand-like, so it is checked with the simplified SPT triggering procedure of Youd et al. (2001). The calculation compares the cyclic stress the earthquake applies (CSR) with the cyclic resistance the soil has (CRR).
Given and required for Example 2.4-2.
Given
Variable
Value
Description
z
15 ft
Depth of the check, in Layer A
zw
5 ft
Depth to water
γ
115 pcf above, 120 pcf below the water table
Unit weights
N60
9
Energy-corrected blow count
FC
35%
Fines content of the cleaner sample used for the check
amax
0.20g
Design peak ground acceleration
Mw
8.0
Design magnitude
MSF
1.19
Magnitude scaling factor for Mw 7.0 (Table 6.5-3)
Kσ
1.0
Overburden correction (σ′v < 2,117 psf)
Required
Cyclic stress ratio CSR
Cyclic resistance ratio CRR7.5
Factor of safety against liquefaction FSL
Equations
Eq. 1: σv, u = γw(z − zw), σ′v = σv − u — stresses
Eq. 2.4-15: rd = 1.0 − 0.00765 z — stress reduction, z in ft ≤ 29.5
FSL = 1.42: liquefaction not predicted, with a modest margin.
Solution
CSR = 0.177, CRR7.5 = 0.211 and FSL = 1.42. Liquefaction is not predicted.
The margin over a typical target of 1.2 to 1.3 (check the client criteria in Section 6.5.9) is modest. The layer’s typical fines content of 78% gives the same correction as 35%, because the correction stops increasing at 35%, so the answer is controlled by the blow count. One N-value of 9 is thin evidence in a variable floodplain silt; CPTu soundings to look for looser zones should come before the result is accepted.
Example 2.4-3: Cyclic Softening of an Elastic Silt
Layer B of Example 2.4-1 is clay-like, so it does not liquefy in the sand sense; it can soften under cyclic loading. The check compares the cyclic stress with a cyclic resistance taken from the soil’s undrained strength ratio (Boulanger and Idriss 2007).
Given and required for Example 2.4-3.
Given
Variable
Value
Description
z
25 ft
Depth of the check, in Layer B
zw
5 ft
Depth to water
γ
115 pcf above; 108 pcf below the water table
Unit weights (108 pcf applied conservatively to the full 20 ft)
OCR
1.5
Lightly overconsolidated
S, m
0.22 and 0.8
SHANSEP parameters
amax, Mw
0.20g; 7.0
Same earthquake as Example 2.4-2
Kα
1.0
Level ground
Required
Undrained strength ratio and CRR
CSR and the factor of safety against cyclic softening
FS = 1.29 on level ground: significant cyclic softening not expected.
Solution
FS = 1.29 on level ground; significant cyclic softening is not expected.
Under the embankment side slope the static shear stress lowers the cyclic resistance (Kα < 1.0), so the check should be repeated beneath the slope. If the factor of safety there falls near 1.0, estimate the permanent displacement with a Newmark analysis (Chapter 6.5) rather than relying on the factor of safety alone.
Example 2.4-4: Capillary Rise and Frost Susceptibility of a Silt Subgrade
A yard track sits on a silt subgrade with the water table 6 ft down. Frost heave needs three things together: a frost-susceptible soil, freezing temperatures in it, and water supply. The capillary rise tells whether the water table can feed ice lenses in the frost zone.
Given and required for Example 2.4-4.
Given
Variable
Value
Description
Soil
ML silt; D10 = 0.0004 in.; e = 0.75
Subgrade
Fines
45% finer than 0.0008 in. (0.02 mm)
Frost-critical fraction
zw
6 ft below top of subgrade
Seasonal high water table
zf
5 ft
Design frost depth
C
0.0013 to 0.0065 in.·ft
Hazen capillary constant, low and high estimates, in the units of Eq. 2.4-5
Required
Range of capillary rise
Frost group and whether frost heave is likely
Equations
Eq. 2.4-5: hc = C / (e D10) — capillary rise (Hazen)
Steps
Step 1 · Capillary rise, low estimate
0.0013 / (0.75 × 0.0004)
hc = 4.3 ft
↓
Step 2 · Capillary rise, high estimate
0.0065 / (0.75 × 0.0004)
hc = 21.7 ft
↓
Step 3 · Does water reach the frost zone?
Low estimate: 6 − 4.3 = 1.7 ft below the subgrade surface; frost zone extends 5 ft down
Yes, even on the low estimate
↓
Step 4 · Frost group
ML with 45% finer than 0.02 mm (more than 3%)
F4
↓
Solution
F4 silt with capillary water in the frost zone: frost heave likely.
Solution
Capillary rise is 4.3 to 21.7 ft; even the low estimate brings water within 2 ft of the subgrade surface. The silt is group F4, and frost heave is likely.
All three conditions for heave in Section 3.8.8.1 are present. The remedies each remove one of them: lower the water table with underdrains (water), replace the silt within the frost depth with non-frost-susceptible material (soil), or insulate (freezing). The design should also allow for a reduced subgrade modulus during the spring thaw.
Example 2.4-5: Collapse Settlement of Loess Under a New Embankment
A 12-ft embankment for a second main track is planned over 10 ft of loess on dense till. Dry loess stands steeply and carries load well, but it can collapse when wetted under load. The first step screens whether collapse is likely; the second estimates how much.
Given and required for Example 2.4-5.
Given
Variable
Value
Description
H
10 ft
Loess thickness above dense till
γd
82 pcf
Dry unit weight
Gs
2.68
Specific gravity
LL
30
Liquid limit
w
11%
Natural water content
εc
6%
Collapse strain from ASTM D4546 at the design stress (about 1.9 ksf at mid-layer)
Required
Collapse screening
Collapse settlement if the full layer is wetted
Equations
Eq. 2.4-24: wsat = γw/γd − 1/Gs — water content at saturation; collapse likely where wsat > LL
Eq. 2.4-26: S = Σ εc H — collapse settlement of the layers expected to wet
Steps
Step 1 · Saturated water content (Eq. 2.4-24)
62.4/82 − 1/2.68 = 0.761 − 0.373
wsat = 38.8%
↓
Step 2 · Screen
38.8% > LL = 30%
Collapse is likely
Spot check: The soil would reach a water content above its liquid limit if saturated at its present density, so its structure cannot hold.
↓
Step 3 · Collapse settlement (Eq. 2.4-26)
0.06 × 10 ft
S = 0.6 ft = 7.2 in.
↓
Solution
About 7 in. of collapse settlement if the loess is wetted: not acceptable.
Solution
Collapse is likely, and wetting the full layer would add about 7.2 in. of settlement to the ordinary compression under the embankment.
Seven inches of differential settlement between the new and existing tracks is not acceptable. The options are to remove and recompact the loess under the new embankment, to pre-wet the foundation before building, or, where removal is not practical, to control every water source and build the ditches and culverts so that water stays away from the toe.