DSM mechanically blends in-situ soil with cementitious binder (Portland cement, lime, or blends) using hollow-stem augers with injection ports. The resulting soil-cement mass (referred to as a "treated mass" or "column") achieves unconfined compressive strengths of 50–300 psi depending on binder content and soil type. DSM is used for:



Design unconfined compressive strength:
Where f_lab = field-to-laboratory strength ratio, commonly 0.2–0.5; use 0.25 for conservative preliminary design. Laboratory mix design targets q_u,lab ≥ 100 psi for soft clay treatment.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| qu | intermediate value computed on this page | Another equation | Computed: q_u = f_lab × q_u,field | project-specific |
| flab | 0.20–0.33 (field-to-laboratory strength ratio | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
Treated mass elastic modulus:
For q_u,field = 50–300 psi this gives about 7,500–150,000 psi. For settlement reduction using composite modulus approach:
Where a_DSM = area replacement ratio of DSM columns within the treated zone (typically 0.15–0.35 for track subgrade improvement).
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| EDSM | intermediate value computed on this page | Another equation | Computed: E_DSM = 150 ⋅ q_u,field to 500 ⋅ q_u,field (psi) | project-specific |
| Ecomposite | soil elastic modulus = a_DSM ⋅ E_DSM + (1 - a_DSM) ⋅ E_soil | Field test, lab test or correlation | Pressuremeter (ASTM D4719), DMT (D6635), plate load (D1196), triaxial secant modulus, or correlation with N60 or qc. | loose sand 200–500, dense sand 1,000–1,700 ksf · by USCS group |
| aDSM | area replacement ratio of DSM columns within the treated zone (typically 0.15–0.35 for track subgrade improvement). | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | typically 0.15–0.35 for track subgrade improvement |
| Railroad | q_u,field minimum (psi) | Test Method | Curing Period (days) | Notes |
|---|---|---|---|---|
| Typical | 50 | ASTM D2166 | 28 | Common practice; confirm with owner |
Owner railroads may set different values. Confirm them against the owner railroad's current standards when the work is scoped.
When there is no time to preload, columns of almost any type — aggregate piers, vibro-concrete columns, DSM columns, augered or driven piles — can carry the embankment to a firm layer. SHRP2 R02 notes that the method is most economical for 15–70 ft of soft clay, peat or organic soil, and cites the Rancocas Creek Railroad Bridge approach in New Jersey (Figure 17-S3). Key points of the recommended design procedure (there is no approved FHWA method):

Table 17-S3. Typical allowable column capacities (SHRP2, adapted from Elias et al., 2006)
| Column type | Allowable capacity (kip) | Typical length (ft) | Diameter/width (in.) |
|---|---|---|---|
| Stone columns | 20–110 | 10–35 | 18–47 |
| Geotextile-encased columns | 65–135 | 10–35 | 30–60 |
| Rammed aggregate piers | 50–150 | 10–35 | 24–36 |
| Augered piles | 75–250 | 15–80 | 12–24 |
| Vibro-concrete columns | 100–250 | 10–35 | 18–24 |
| Deep mixing columns | 90–270 | 30–100 | 24–120 |
| Precast concrete piles | 90–225 | 30–50 | up to 24 |
| Steel H / pipe piles | 90–450 / 180–550 | 15–100 / 30–130 | 6–12 / 8–48 |



Source: SHRP2 R02 / GeoTechTools (2012). Column-Supported Embankments — fact sheet, design guidance and photographs

Technology sheets for this method · see 7.2.16 Technology Library







Deep soil mixing is usually specified for strength and settlement. This study used it to stop seasonal heave and shrinkage of an expansive clay of moderate depth beneath pavements and earth structures.
For railroad work: Expansive clay subgrades cause recurring track surface and cross-level defects in dry and wet seasons (Chapter 2.5). Where the active zone is too deep for lime treatment of the top lifts (Section 7.2.7), soil-mix columns are an option for short critical lengths such as turnouts, crossings and bridge approaches.
Source: Madhyannapu, Puppala, Bhadriraju and Nazarian (2009), in Han, J. et al. (eds.) (2009), Advances in Ground Improvement, ASCE GSP 188. Full reference under Supplemental References.
Strength tests alone do not show whether binder is evenly distributed through a column. The authors measured the electrical resistivity of cores, and the parameters derived from it (formation factor, shape factor and anisotropy factor), and found them direct indicators of mixing uniformity. The results agreed with SPTs on the columns and unconfined compression tests on the cores. Double-slurry mixing produced markedly more uniform columns than single-slurry mixing.
For railroad work: Add a uniformity check to deep-mixing QA for railroad work: resistivity of cores, or geophysical testing of whole columns, alongside core recovery and strength. Ask the contractor which mixing process will be used, because the process affects uniformity as much as the binder content does.
Source: Liu, Zhang and Zhu (2009), in Han, J. et al. (eds.) (2009), Advances in Ground Improvement, ASCE GSP 188. Full reference under Supplemental References.
Column-type elements behave in three ways: granular columns (sand and stone), soil-cement columns (deep-mixed, lime and jet-grouted) and rigid piles (concrete and steel). Composite columns combine them by placing a small-diameter plain concrete, reinforced concrete or steel core in the center of a granular or soil-cement column.
For railroad work: Composite columns fit bridge approach embankments and high fills where ordinary soil-cement columns would be too weak in bending under the side slopes (see Section 7.2.8 on lateral behavior of embankment columns), but a full pile foundation is more than the job needs.
Source: Zheng, Liu and Chen (2009), in Han, J. et al. (eds.) (2009), Advances in Ground Improvement, ASCE GSP 188. Full reference under Supplemental References.