↑ Parent Menu⌂ Main Menu
← Chapter 7.3 Pavement Subgrade Evaluation
GHRM
Railway Ground Hazard Risk Management · 7.0 · Design
Sections · click a car to open it

7.3.8 Worked Examples

Pavement subgrade evaluation for railroad facilities encompasses two distinct but related infrastructure domains: (1) paved surfaces within railroad right-of-way —…
Authors: Daniel P. Colwell and Mario Ruel
7.3.8 Worked Examples
The three examples cover a flexible pavement, a rigid pavement and the seasonal subgrade modulus in a frost climate, for intermodal yards. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution.
Example 7.3-1: Flexible Pavement for Reach Stacker Lanes

New reach stacker lanes at an intermodal yard expansion on a Class I railroad located in Kansas City, Missouri. The AASHTO 1993 equation gives the structural number the subgrade needs for the design traffic; the layers are then chosen to supply it. The example then shows how much a treated subgrade saves.

Reach stacker lanesAsphalt a1, D1 = ?Base a2, m2 = 0.90, D2 = ?Subbase m3 = 0.90, D3 = ?(Option) 5% lime, 12 in., Mr 9,000CL subgrade, CBR 4%, Mr = 6,000 psiSN = ? Section?GivenW18 = 8,000,000 ESALsCBR 4%; Mr = 6,000 psiZR = −1.645; S0 = 0.45ΔPSI = 2.2; m2 = m3 = 0.90Lime-treated Mr = 9,000 psiRequiredRequired SNLayer section with and without limeBlack = given; red = required
Given and required for Example 7.3-1.

Given

VariableValueDescription
W188,000,000 ESALs20-year design (assumed for illustration)
SubgradeCL; soaked CBR = 4%; Mr = 1,500 × 4 = 6,000 psi
ZR, S0−1.645 (R = 95%); 0.45
ΔPSI4.2 − 2.0 = 2.2
m2, m30.90Fair drainage
Treated Mr9,000 psi5% lime, top 12 in.

Required

  • Required SN
  • A layer section that supplies it, with and without lime treatment

Equations

  1. Eq. 1 (AASHTO 1993): log W18 = ZRS0 + 9.36 log(SN + 1) − 0.20 + log(ΔPSI/2.7)/[0.40 + 1,094/(SN + 1)5.19] + 2.32 log Mr − 8.07 — solve for SN by trial
  2. Eq. 2: SN = a1D1 + a2D2m2 + a3D3m3 — layer coefficients a = 0.44 (HMA), 0.14 (base), 0.11 (subbase)

Steps

Step 1 · Trial SN = 6.0 (Eq. 1)
−0.740 + 7.909 − 0.20 − 0.204 + 8.765 − 8.07
W18 = 28.8M: too high
↓
Step 2 · Trial SN = 4.5
−0.740 + 6.930 − 0.20 − 0.160 + 8.765 − 8.07
W18 = 3.35M: too low
↓
Step 3 · Solve
SN = 5.07 for 8.0M
↓
Step 4 · Sections (Eq. 2)
4-8-10: 1.76 + 1.01 + 0.99 = 3.76; 6-10-12: 2.64 + 1.26 + 1.19
3.76 (deficient); 5.09 ≥ 5.07
↓
Step 5 · With lime (Mr = 9,000 psi)
SN required 4.46; 6-8-9: 2.64 + 1.01 + 0.89
SN = 4.54 ≥ 4.46
Spot check: Saves 2 in. of base and 3 in. of subbase, about 56 lb/ft² of aggregate.
↓
Solution
SN = 5.07: 6 in. HMA, 10 in. base, 12 in. subbase; or 6-8-9 on lime-treated subgrade.

Solution

Required SN = 5.07. On the untreated subgrade use 6 in. HMA, 10 in. base and 12 in. subbase (SN 5.09). With the top 12 in. lime-treated, 6 in. HMA, 8 in. base and 9 in. subbase (SN 4.54) suffice.

The aggregate saved is worth roughly $0.50/ft² at an assumed $18/ton, which must be weighed against the cost of the lime treatment. Treatment also lifts the subgrade CBR above an assumed 8% minimum, which matters for construction traffic as much as for the design.

Example 7.3-2: Rigid Pavement for a Crane Runway

An RTG crane runway and reach stacker lanes at an intermodal terminal on a Class I railroad located in Winnipeg. The silty sand subgrade is frost-susceptible to a design frost depth of 8 ft and is replaced with granular material, which also raises the support for the slab.

Crane runwayDoweled concrete slab D = ?Granular replacement to 8.0 ft (keff = 200 pci)SM subgrade, CBR 7%, F3D = ?GivenW18 = 12,000,000 ESALsZR −1.645; S0 0.35; ΔPSI 2.5f′c 4,500; S′c 650 psiEc = 3.82×106 psiJ = 3.2; Cd = 1.0; keff 200 pciRequiredSlab thickness DBlack = given; red = required
Given and required for Example 7.3-2.

Given

VariableValueDescription
W1812,000,000 ESALs
ZR, S0−1.645; 0.35
ΔPSI, pt2.5; 2.5
SubgradeSM, CBR 7%, F3: replaced to 8.0 ft with granular subbase
keff200 pciOn the replacement subbase
Concretef′c = 4,500 psi; S′c = 650 psi; Ec = 3.82×106 psi
J, Cd3.2 (doweled); 1.0

Required

  • Slab thickness D

Equations

  1. Eq. 1 (AASHTO 1993): log W18 = ZRS0 + 7.35 log(D + 1) − 0.06 + log(ΔPSI/3.0)/[1 + 1.624×107/(D + 1)8.46] + (4.22 − 0.32pt) log{S′cCd(D0.75 − 1.132) / [215.63J(D0.75 − 18.42/(Ec/k)0.25)]} — rigid pavement; solve for D by trial

Steps

Step 1 · D = 11 in.
(Ec/k)0.25 = 11.76; ratio term log(3,580/3,494) = 0.0105
W18 ≈ 18.5M ≥ 12M
↓
Step 2 · D = 10 in.
W18 ≈ 10.1M < 12M
↓
Step 3 · Thickness
D = 11 in. governs
↓
Solution
11-in. doweled JPCP.

Solution

An 11-in. doweled jointed plain concrete slab (about 18.5M ESAL capacity); 10 in. carries only about 10M.

Use #5 dowels at 12 in. across transverse joints spaced at 15 ft. Replace the F3 subgrade to 8.0 ft with non-frost-susceptible granular fill (no more than 3% passing the No. 200 sieve) over a geotextile separator; without it, frost heave would break the slab regardless of its thickness.

Example 7.3-3: Frost Depth and Effective Seasonal Resilient Modulus

Access roads at a terminal on a Class I railroad located in Winnipeg. The subgrade is stiff when frozen and very soft during the spring thaw. Averaging the moduli would hide the thaw; the AASHTO relative damage method weights each month by the damage it does.

2000400060008000MonthMr (psi)JunJulAugSepOctNovDecJanFebMarAprMayFrost depth = ? Effective Mr = ?GivenCL: w = 22%; γd = 95 pcfFI = 3,500 °F-dayskf = 1.10 BTU/hr·ft·°FMr by month (chart)RequiredFrost depthEffective seasonal Mr Black = given; red = required
Given and required for Example 7.3-3.

Given

VariableValueDescription
SubgradeCL; w = 22%; γd = 95 pcf
FI3,500 °F-daysDesign freezing index
kf1.10 BTU/hr·ft·°FFrozen conductivity
Mr by month5,500 (Jun–Oct); 4,000 (Nov); 8,000 (Dec–Feb); 2,000 (Mar); 1,375 (Apr–May) psi

Required

  • Frost depth
  • Effective Mr

Equations

  1. Eq. 1: L = 144 w γd; Zf = √(48 kf FI / L) — latent heat and Stefan frost depth, ft
  2. Eq. 2: uf = 1.18×108 Mr−2.32; Mr,eff = (ūf/1.18×108)−1/2.32 — AASHTO relative damage

Steps

Step 1 · Latent heat
144 × 0.22 × 95
3,010 BTU/ft³
↓
Step 2 · Frost depth
√(48 × 1.10 × 3,500 / 3,010) = √61.4
Zf = 7.8 ft
↓
Step 3 · Monthly damage
0.248, 0.519, 0.104, 2.59, 6.18
ūf = (5×0.248 + 0.519 + 3×0.104 + 2.59 + 2×6.18)/12 = 1.42
↓
Step 4 · Mr,eff
(1.42/1.18×108)−1/2.32
2,590 psi
Spot check: The harmonic mean would give 3,440 psi; the two thaw months carry 83% of the damage.
↓
Solution
Zf = 7.8 ft; design Mr = 2,590 psi.

Solution

Frost penetrates about 7.8 ft, and the effective design Mr is about 2,590 psi, less than half the summer value of 5,500 psi.

Recompute SN with this value. Replacing the frost-susceptible subgrade with granular material through the frost depth removes most of the thaw weakening at the depths that matter.

← Previous · 7.0 Design Chapter 7.2 — Ground Improvement Methods
Next · 7.0 Design → Chapter 7.4 — Earthworks Asset Management and Remedial Design