The Standard Penetration Test is the single most important field test in railroad geotechnical practice. Nearly every design parameter used in embankment stability, foundation bearing capacity, settlement, and liquefaction analysis for our railroad clients is either directly derived from SPT N-values or calibrated against them. Executing the SPT correctly — and applying the complete correction chain before using N-values in analysis — is a non-negotiable quality standard.

Procedure:
Refusal: If 50 blows are required for less than 6 in. of penetration, the test is terminated and recorded as refusal at the applicable penetration depth.
The raw SPT N-value is meaningless for quantitative analysis without correction to a standard energy level of 60% of the theoretical free-fall energy. The corrected value, designated N₆₀, is calculated as:
Where:
Measure and report hammer energy for each SPT rig (ASTM D4633, withdrawn 2025). Measure energy for each rig with an SPT analyzer (for example a PDA with instrumented rods) at the start of each field mobilization, and report the measured E_m values in the investigation report.

| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| N60 | SPT blow count = N_raw × E_m × C_B × C_R × C_S 0.60 | Field test | Standard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633, withdrawn 2025) to correct to N60. | loose sand 4–10, dense 30–50 blows/ft · by USCS group |
| Em | hammer energy ratio (energy delivered / theoretical energy) | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | ≈ 0.80–0.85 |
| CB | borehole diameter correction: 1.00 for 2.5–4.5 in | Test setup | Dimension of the test equipment or specimen: from the test standard or the lab/field test record. | project-specific |
| CR | rod length correction: 0.75 for rod length < 10 ft | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| CS | sampler correction: 1.00 for split spoon without liner | Test setup | Dimension of the test equipment or specimen: from the test standard or the lab/field test record. | project-specific |
For liquefaction and relative density analyses, N₆₀ is further corrected to a reference overburden stress of one atmosphere (P_a = 2,117 psf, about 1.06 tsf) to yield (N₁)₆₀:
Where:
Note: C_N is capped at 1.7 (Youd et al. 2001) to prevent unrealistically high corrections at low effective stress (shallow depth).
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| CN | intermediate value computed on this page | Another equation | Computed: C_N = √ P_a σ'_v ≤ 1.7 | project-specific |
| (N1)60 | SPT blow count = C_N × N60 | Field test | Standard Penetration Test (ASTM D1586); measure hammer energy (ASTM D4633, withdrawn 2025) to correct to N60. | loose sand 4–10, dense 30–50 blows/ft · by USCS group |
| Pa | atmospheric pressure = 2,117 psf = 1.0 tsf | Constant | Physical constant or standard value. | project-specific |
| σ'v | vertical effective stress at the test depth (psf) | Another equation | From unit weights, layer thicknesses and the groundwater level: σv = Σγihi, u = γw × depth below the water table, σ' = σ − u. Use the design groundwater level. | project-specific |
| Material | N₆₀ (blows/ft) | Relative Density / Consistency |
|---|---|---|
| Sand | 0–4 | Very Loose |
| Sand | 4–10 | Loose |
| Sand | 10–30 | Medium Dense |
| Sand | 30–50 | Dense |
| Sand | > 50 | Very Dense / Refusal |
| Clay | 0–2 | Very Soft |
| Clay | 2–4 | Soft |
| Clay | 4–8 | Medium Stiff |
| Clay | 8–15 | Stiff |
| Clay | 15–30 | Very Stiff |
| Clay | > 30 | Hard |
Energy and rod corrections cannot fix a badly run test. GEC 5 (after Kulhawy and Mayne, 1990) lists the field causes and which way they push N:
Table 6-S3. Factors affecting SPT results
| Cause | Effect | Influence on N |
|---|---|---|
| Inadequate cleaning of hole | Test not in original soil; trapped soil compressed in sampler | Increases |
| Water head not maintained in borehole | Bottom of hole becomes quick | Decreases |
| Careless measure of drop | Energy varies, usually low | Increases |
| Hammer weight inaccurate | Energy varies 5–7% commonly | Either |
| Hammer strikes collar eccentrically | Energy reduced | Increases |
| No free fall (stiff rope, ungreased sheave, > 2 turns on cathead) | Energy reduced | Increases |
| Sampler driven above bottom of casing | Driven in disturbed, densified soil | Increases greatly |
| Non-standard sampler | Correlations invalid | Either |
| Coarse gravel or cobbles | Sampler plugged or impeded | Increases |
| Bent drill rods | Energy transfer inhibited | Increases |
Note that most errors increase N — i.e., they are unconservative. GEC 5 also notes that Skempton’s tabulated energy ratios (donut 0.5–1.0, safety 0.7–1.2, automatic 0.8–1.5 as CE = ER/60) are guidance only; measure ER per ASTM D4633 (withdrawn 2025).
Source: Sabatini, P. J. et al. (2002). Evaluation of Soil and Rock Properties. Geotechnical Engineering Circular No. 5, FHWA-IF-02-034 (superseded by GEC 5, Geotechnical Site Characterization, FHWA-NHI-16-072 (2017))
Case study: 4.1.14.2 SPT field values: counting error and three rigs on one site (Look 2023), in Section 4.1.14 Case Studies.
Silts and fine sands below the water table. In very fine sand and silt below the water table, the sampler drives faster than the pore water can drain. Dense soils dilate and develop suction, so the blow count reads high. The correction attributed to Terzaghi, and recommended by Tomlinson, reduces blow counts above 15:
N′ = 15 + ½ (N − 15) for N > 15; no correction for N ≤ 15
Apply it to the field N in saturated silts and very fine or silty sands before the energy and overburden corrections, when the N value will be used for relative density, friction angle or bearing. Do not apply it when using the liquefaction methods, which were calibrated on N values without it.
Which N the density table applies to. The Terzaghi and Peck relative-density limits for sand in Section 4.1.3.4 (0–4, 4–10, 10–30, 30–50, over 50) are good average values for normally consolidated natural sands once the blow counts are corrected for both energy and overburden, that is, for (N1)60 (Skempton 1986). Use (N1)60 with that table for sand; the clay consistency rows are read with N60.
Dynamic probes. Continuous dynamic probes are driven without a borehole and record blows per 4 in. (100 mm). The super-heavy probe (DPSH) has the SPT hammer, drop and diameter, so three consecutive 4-in. counts add up to an equivalent N. For other probes, an equivalent N in granular soil follows from assuming that penetration is proportional to the energy per blow and inversely proportional to the cone area:
NSPT = (Mp Fp As Ps) / (Ms Fs Ap Pp) × probe blows
where M and F are the hammer weight and drop, A is the end area, P is the penetration per recorded count, and subscripts s and p refer to the SPT (140 lb, 30 in., about 3.0 in.², 12 in.) and the probe. For the heavy probe (DPH: 110 lb, 19.7 in., 1.72-in. cone of 2.33 in.², counted per 4 in.) this gives N ≈ 2 × DPH blows per 4 in. There is no such equivalence in clay, where the probe’s rod friction and the soil’s rate effects differ; use probe results in clay only with correlations calibrated to that probe.
For railroad work: Fine sands and silts below the water table are common in floodplain approaches, culvert and bridge foundations, and tracks on old lake beds. Note on the boring log where the Terzaghi correction was applied, so later users do not apply it twice or leave it out of a liquefaction check. Dynamic probes are a quick way to fill gaps between borings along a track shoulder or embankment toe. Correlate them to the SPT at one or two borings on the job before using the conversion, and stop the probe where rod friction builds up in clay.
Source: Carter, M. and Bentley, S. P. (2016). Soil Properties and their Correlations, 2nd ed., §3.3.2–3.3.3, Eqs. 3.13 and 3.15. Summarized and paraphrased; probe dimensions converted to US units. Full reference under Supplemental References.
A culvert under a main line of a Class I railroad located in Louisiana is to be replaced with a jacked pipe. A boring at the jacking pit found fine silty sand below a water table 8 ft deep. At 25 ft an automatic hammer with a measured energy ratio of 82% recorded N = 31, with 3 ft of rod stick-up. A heavy dynamic probe (DPH) pushed beside the boring recorded 14 blows per 4 in. at the same depth. The engineer must correct the blow count, classify the density of the sand for the jacking-pit design, and check the probe against the boring.
| Variable | Value | Description |
|---|---|---|
| N | 31 | Field blow count at 25 ft, fine silty sand below the water table |
| Em | 0.82 | Measured hammer energy ratio (automatic hammer) |
| Rod length | 28 ft | 25 ft plus 3 ft stick-up: CR = 0.95 |
| CB, CS | 1.00, 1.00 | 4-in. borehole; standard sampler |
| Water table | 8 ft | γ = 120 pcf above, 125 pcf below; γw = 62.4 pcf |
| DPH | 14 blows per 4 in. | Heavy dynamic probe beside the boring, same depth |
(a) N′ = 23. (b) N60 = 30 and (N1)60 = 31. (c) Medium dense to dense with the fine-sand correction; dense without it. (d) The probe gives N ≈ 28, which agrees with the field blow count.
For the jacking-pit design, take the sand as medium dense. The uncorrected value would overstate the friction angle by a few degrees and understate the face pressure needed to keep the silty sand from running into the pipe. Fine silty sand below the water table is also the soil most likely to flow into a jacking pit or under a pipe face, so the dewatering and face-support plan matters more than the exact density class. Record on the log that the Terzaghi correction was used for the design values. Use the uncorrected N60 for any liquefaction check. Because the probe agrees with the boring, further probes can fill in the profile along the pipe alignment between borings.