Borings and sampling form the physical backbone of every geotechnical investigation we conduct for railroad clients.
Authors: Daniel P. Colwell and Mario Ruel
4.1.16 Sample Disturbance: Sampler Geometry and Recovery

A strength or consolidation test is only as good as the sample. The Corps of Engineers' Geotechnical Investigations manual (EM 1110-1-1804, Appendix F) summarizes Hvorslev's classic criteria for sampler design. The area ratio, the volume of soil displaced by the cutting shoe relative to the sample, may be the most important single factor. Inside clearance lets the sample enter without wall friction. Outside clearance should be small, or wall friction can cause a bearing failure below the shoe. Sample length should be limited, the tube pushed in one fast, continuous stroke rather than driven, and recovery recorded. The manual also lists the usual causes of poor recovery: pressure above the sample from poor venting, suction below the tube as it is pulled, and failure to shear the sample off at the shoe.

4.1.16.1 Criteria

Equation 4.1-1. Hvorslev's sampler ratios (EM 1110-1-1804, Eqs. 2-1 to 2-3)

Ca = (Dw² − De²)/De²;   Ci = (Ds − De)/De;   Co = (Dw − Dt)/Dt
Table 4.1-3. Recommended limits (Hvorslev, as summarized in EM 1110-1-1804)
ItemRecommendation
Area ratio CaPreferably below 10 to 15%. ISSMFE (1966) accepted 5 to 20% with the edge taper reduced from 15° to 9°
Inside clearance Ci0 to 1% for very short samples; 0.5 to 3% for medium length; 0.75 to 1.5% for L/D of 6 to 8
Outside clearance CoUnder 2 to 3% in cohesive soil; zero in cohesionless soil
Length to diameter5 to 10 in cohesionless soil; 10 to 20 in cohesive soil
AdvancePush with a fast, continuous, uniform motion; driving causes the greatest disturbance
RecoveryVent the tube, rotate one or two turns to shear the sample, or use a piston sampler

4.1.16.2 Worked example

A standard 3 in. thin-wall tube of 16 gauge steel has an area ratio of 9.3% and a 2 in. tube of 18 gauge 10.6%. Both are within Hvorslev's preferred range. The standard split spoon used for the SPT has an area ratio of 111.6%, so its samples are disturbed and suitable only for index tests. A 24 in. push that recovers 21 in. gives 88% recovery and a warning to find out why. The nominal tubes show zero inside clearance; tubes with a rolled or swaged cutting edge give the 0.75 to 1.5% Hvorslev suggests, so measure the actual shoe.

On the boring log, record the sampler, how it was advanced, the length pushed and the length recovered for every sample. When laboratory strengths look low or consolidation curves show no clear break, check sample quality before concluding that the clay is weak.

Open the sampler disturbance calculator →
Hvorslev's area ratio, inside and outside clearance, length-to-diameter ratio and recovery, compared with the recommended limits, with common samplers for comparison.

4.1.16.3 Sources in the library

These documents are in the reference library. The summaries above are paraphrased; equations and tabulated values are standard or published. Individual railroads, clients and projects are not named.

  • U.S. Army Corps of Engineers, Geotechnical Investigations, EM 1110-1-1804 (2001): Appendix F, sample quality and the parameters that affect sample disturbanceOfficial page ↗
  • N. Simons, B. Menzies and M. Matthews, A Short Course in Geotechnical Site Investigation: sampling methods and sample qualityFind source ↗
  • B.G. Look, Handbook of Geotechnical Investigation and Design Tables (2007): sampling and testing in site investigationsFind source ↗
← Previous · 3.0 Risk Management Chapter 3.10 — Mining and Man-Made Hazards
Next · 5.0 Testing → Chapter 5.1 — In Situ Testing