↑ Parent Menu⌂ Main Menu
← Chapter 4.1 Borings and Sampling
GHRM
Railway Ground Hazard Risk Management · 4.0 · Subsurface Exploration
Sections · click a car to open it

4.1.7 Annotated Sample Boring Log

Borings and sampling form the physical backbone of every geotechnical investigation we conduct for railroad clients.
Authors: Daniel P. Colwell and Mario Ruel
4.1.7 Annotated Sample Boring Log

Project: Bridge Replacement — a Class I railroad line located in Virginia Boring: B-2 Date: April 15, 2026 Driller/Rig: drilling subcontractor, track-mounted rig Drilling Method: HSA (0–42 ft), Mud Rotary (42–65 ft) Hammer Type: Automatic Trip (E_m = 0.83, measured by PDA; N₆₀ uses C_R by rod length with 3 ft of stick-up) Water Table: Encountered at 18.0 ft during drilling; stabilized at 16.5 ft after 30 minutes

Pile Boring Log
Pile Boring Log
Depth (ft)SampleBlows (6"/6"/6")N_rawN₆₀Soil DescriptionLab Tests
0–2SS-13/4/488Brown medium sand, trace gravel; fill—
5–6.5SS-25/6/71313Brown silty fine sand; medium dense; moistSieve
10–11.5SS-38/10/122226Gray silty sand; medium dense; moistSieve, Atterberg
15–16.5ST-1Push——Gray-brown firm silty clay; push recovery 18 in.Consol, UU Tri
20–21.5SS-412/15/183343Gray sandy gravel; dense; wet; below GWT—
25–26.5SS-518/22/254762Gray sandy gravel; very dense; wet—
30–31.5SS-650/4"R—Refusal: 50 blows for 4 in. of penetration—
35–36.5CS-1Core runTCR=75%—Gray medium sandstone; RQD=55%; moderately fracturedUnconf. Comp.
40–41.5CS-2Core runTCR=92%—Gray-brown sandstone; RQD=88%; slightly fractured—

SS = Split Spoon; ST = Shelby Tube; CS = Core Sample; R = Refusal; GWT = Groundwater Table; Consol = Consolidation; UU Tri = Unconsolidated-Undrained Triaxial; Unconf. Comp. = Unconfined Compression

Figure 4.1-1 Placeholder: Full-scale boring log in a typical railroad format, showing graphical soil profile, blow count vs. depth plot, water level indicators, and sample retention summary. [Insert CAD or boring log software output here.]

Empirical equation note · this section

Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.

  • IS-01 SPT energy & procedure correction N₆₀Use: All soils tested by SPT (ASTM D1586). Normalizes blow count to 60% of theoretical free-fall energy, the basis for most U.S. correlations. Limits: CE ranges ~0.5–1.6 depending on hammer type; use measured energy (ASTM D4633, withdrawn 2025) where available. Rod-length factor ranges differ between Skempton (1986) and Youd et al. (2001).
← Previous · 3.0 Risk Management Chapter 3.10 — Mining and Man-Made Hazards
Next · 5.0 Testing → Chapter 5.1 — In Situ Testing