↑ Parent Menu⌂ Main Menu
← Chapter 4.1 Borings and Sampling
GHRM
Railway Ground Hazard Risk Management · 4.0 · Subsurface Exploration
Sections · click a car to open it

4.1.6 Worked Calculation Examples

Borings and sampling form the physical backbone of every geotechnical investigation we conduct for railroad clients.
Authors: Daniel P. Colwell and Mario Ruel
4.1.6 Worked Calculation Examples
The three examples cover the corrections and ratios that turn field records into design numbers: SPT corrections, the area ratio of a sampling tube, and RQD. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution.
Example 4.1-1: SPT Corrections for a Bridge Approach Embankment

A boring for a bridge approach embankment replacement on a Class I railroad located in western Kansas passes through silty sand into medium-dense alluvial sand. The raw blow count is corrected first for energy and equipment, giving N60, and then for overburden, giving (N1)60, which is the value most correlations for sand expect.

Embankment / sandSand051015202530Depth (ft)GWT 8 ftN = 18 blows/ft at 20 ftN60, (N1)60, Dr = ?Automatic trip hammer, 4-in. HSAGivenN = 18 at 20 ftEm = 0.82; CB = 1.00CR = 0.95; CS = 1.00γ = 120 / 122 pcf; GWT 8 ftRequiredN60 (N1)60 Relative densityBlack = given; red = required
Given and required for Example 4.1-1.

Given

VariableValueDescription
N18 blows/ftRaw blow count at 20 ft
Em0.82Automatic trip hammer
CB1.004-in. hollow-stem auger hole
CR0.95About 23 ft of rod (20 ft plus 3 ft of stick-up)
CS1.00Split spoon without liner
γ120 pcf above, 122 pcf below the water table
zw8 ftWater table

Required

  • N60
  • (N1)60 and relative density

Equations

  1. Eq. 1: N60 = N Em CB CR CS / 0.60 — energy and procedure correction
  2. Eq. 2: σ′v = σv − γw(z − zw) — effective stress at the test depth
  3. Eq. 3: CN = (2,117/σ′v)0.5 ≤ 1.7; (N1)60 = CN N60 — overburden normalization

Steps

Step 1 · N60 (Eq. 1)
18 × 0.82 × 1.00 × 0.95 × 1.00 / 0.60 = 18 × 1.298
N60 = 23.4, use 23
↓
Step 2 · σ′v at 20 ft (Eq. 2)
σv = 8(120) + 12(122) = 2,424 psf; u = 12(62.4) = 749 psf
σ′v = 1,675 psf
↓
Step 3 · CN and (N1)60 (Eq. 3)
(2,117/1,675)0.5 = 1.124; 1.124 × 23
(N1)60 = 26
Spot check: CN is just above 1 because the effective stress is a little below one atmosphere (2,117 psf).
↓
Solution
N60 = 23; (N1)60 = 26.

Solution

N60 = 23 and (N1)60 = 26, at the medium dense to dense boundary (Dr about 65 to 75%).

The automatic hammer delivers more energy than the 60% standard, so the corrected count is higher than the raw one. Sand this dense has moderate to high liquefaction resistance, but it should still be screened formally with the site’s design ground motion (Chapter 6.5).

Example 4.1-2: Area Ratio of a Push Tube in Soft Clay

Soft marine clay is to be sampled at 22 to 26 ft for a passenger bridge approach rehabilitation. The crew has a 3.5-in. push tube. Its area ratio says how much soil the tube displaces; the project specification says which sampler must be used.

cutting shoeDe = 3.50 in.Di = 3.375 in.Section at the shoeArea ratio = ? Acceptable?GivenDe = 3.50 in.Di = 3.375 in.Piston sampling required for soft clayRequiredArea ratio Ar Is the tube acceptable?Black = given; red = required
Given and required for Example 4.1-2.

Given

VariableValueDescription
De3.50 in.Outside diameter at the cutting shoe
Di3.375 in.Inside diameter at the cutting shoe
SpecPiston sampling required for soft clay used for undrained strengthProject specification

Required

  • Area ratio and whether the tube is acceptable

Equations

  1. Eq. 1: AR = (De² − Di²) / Di² × 100% — area ratio; ASTM D1587 (withdrawn 2024) requires 10% or less

Steps

Step 1 · AR (Eq. 1)
(12.25 − 11.39) / 11.39 × 100 = 0.86 / 11.39 × 100
AR = 7.5% < 10%: meets ASTM D1587 (withdrawn 2024)
↓
Step 2 · Specification
Piston sampler required regardless of AR
↓
Solution
AR = 7.5%, geometrically acceptable, but a piston sampler is still required.

Solution

AR = 7.5%, so the tube meets ASTM D1587 (withdrawn 2024). The specification still requires a fixed-piston sampler for soft clay strength samples.

Area ratio controls one kind of disturbance; the piston controls another, by holding the sample in the tube during withdrawal. Record the requirement in the pre-field plan and procure the piston sampler before mobilization.

Example 4.1-3: RQD and Recovery of a Sandstone Core Run

A 10-ft HQ core run in sandstone for a bridge scour and foundation investigation on a Class I railroad located in the Appalachians. RQD counts only sound pieces at least 4 in. long; recovery counts everything that came up.

HQ sandstone core run79.56.584.5not recoveredRun = 120 in. (10 ft); recovered 45.0 in.Pieces (in.): 7, 2.5, 9.5, 1, 6.5, 8, 0.5, 4.5, 3, 2.5RQD = ? TCR = ? Rock quality?GivenRun 10 ft = 120 in. (HQ)Ten pieces, total 45.0 in.RQD counts pieces ≥ 4 in.RequiredRQD and TCRRock quality and foundation meaningBlack = given; red = required
Given and required for Example 4.1-3.

Given

VariableValueDescription
Run10 ft = 120 in.HQ core
Pieces7.0, 2.5, 9.5, 1.0, 6.5, 8.0, 0.5, 4.5, 3.0, 2.5 in.Measured in the core box; total 45.0 in.

Required

  • RQD and TCR
  • Rock quality and what it means for the foundation

Equations

  1. Eq. 1: RQD = Σ (pieces ≥ 4 in.) / run length × 100% — ASTM D6032
  2. Eq. 2: TCR = recovered length / run length × 100% — total core recovery

Steps

Step 1 · Pieces ≥ 4 in.
7.0 + 9.5 + 6.5 + 8.0 + 4.5
35.5 in.
↓
Step 2 · RQD (Eq. 1)
35.5 / 120
RQD = 30%
↓
Step 3 · TCR (Eq. 2)
45.0 / 120
TCR = 37.5%
Spot check: All ten pieces sum to 45.0 in.
↓
Solution
RQD = 30% (poor); TCR = 37.5%.

Solution

RQD = 30%, poor rock; TCR = 37.5%.

Low RQD with low recovery points to highly fractured sandstone, probably a weathered or fault-adjacent zone. Have a geologist review the core box photographs and describe the fractures before foundation design proceeds. This rock is unlikely to suit end bearing without a deep socket into competent rock below.

← Previous · 3.0 Risk Management Chapter 3.10 — Mining and Man-Made Hazards
Next · 5.0 Testing → Chapter 5.1 — In Situ Testing