↑ Parent Menu⌂ Main Menu
← Chapter 4.1 Borings and Sampling
GHRM
Railway Ground Hazard Risk Management · 4.0 · Subsurface Exploration
Sections · click a car to open it

4.1.4 Undisturbed Sampling — Shelby Tube and Piston Sampler

Borings and sampling form the physical backbone of every geotechnical investigation we conduct for railroad clients.
Authors: Daniel P. Colwell and Mario Ruel
4.1.4 Undisturbed Sampling — Shelby Tube and Piston Sampler
4.1.4.1 Shelby Tube Sampling (ASTM D 1587)

Thin-walled Shelby tube samples are the standard method for recovering nominally undisturbed specimens of soft to medium stiff cohesive soils for consolidation, triaxial, and direct shear testing. The degree of sample disturbance is quantified by the Area Ratio (AR):

Storage of Samples
Storage of Samples
AR = De2 - Di2Di2 × 100%

Where:

  • D_e = outside diameter of the tube cutting edge (in.)
  • D_i = inside diameter of the tube (in.)

For a standard 3-in. OD Shelby tube with 2.875-in. ID:

AR = (3.0)2 - (2.875)2(2.875)2 × 100% = 9.000 - 8.2668.266 × 100% = 8.9%

An area ratio of 10% or less is the usual criterion for undisturbed sampling (Hvorslev; see Section 4.1.16). Standard 3-in. thin-walled tubes (ASTM D1587, withdrawn 2024) meet it.

Sample Quality Designation (SQD) per Lunne et al. (1997) for clays with OCR 1–2, based on the void ratio change (Δe/e₀) when the specimen is reloaded to the in situ stress in the consolidation test:

Δe/e₀Sample Quality
< 0.04Very good to excellent
0.04–0.07Good to fair
0.07–0.14Poor
> 0.14Very poor

Report sample quality (SQD) for Shelby tube samples used in consolidation analysis. Where undrained strength of soft clay governs design, specify fixed-piston samplers rather than open push tubes.

Inputs for the equations in this section (3)
SymbolWhat it isComes fromHow to get itTypical range
ARintermediate value computed on this pageAnother equationComputed: AR = D_e^2 - D_i^2 D_i^2 × 100%project-specific
Deoutside diameter of the tube cutting edge (in.)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Diinside diameter of the tube (in.)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
4.1.4.2 Fixed-Piston Sampler

The fixed-piston sampler uses a piston held stationary at the base of the borehole while the sample tube is advanced by hydraulic push, creating a partial vacuum that retains the sample and prevents water entry. Piston samples typically have lower disturbance than conventional push tubes and are preferred for marine and lacustrine soft clay investigations where sample quality is paramount.

Hvorslev fixed-piston sampler.
Supplemental Figure 6-S1. Hvorslev fixed-piston sampler. Source: U.S. Army Corps of Engineers (2001). Geotechnical Investigations. EM 1110-1-1804.
Pitcher double-tube core barrel sampler &mdash; a spring-loaded inner tube that projects ahead of the cutting bit in soft soil and retracts in hard soil; useful in stiff clays and weak rock where Shelby tubes cannot be pushed.
Supplemental Figure 6-S2. Pitcher double-tube core barrel sampler — a spring-loaded inner tube that projects ahead of the cutting bit in soft soil and retracts in hard soil; useful in stiff clays and weak rock where Shelby tubes cannot be pushed. Source: U.S. Army Corps of Engineers (2001). Geotechnical Investigations. EM 1110-1-1804.
Supplemental reference

Materials that defeat standard sampling

GEC 5 (Table 47) flags soils and soft rocks where conventional SPT and tube sampling give misleading results. The ones that show up most often on railroad corridors:

MaterialSampling difficultyEngineering concern
Colluvium and talusThin weak lenses; rock fragments prevent sampling; boulders preclude drillingThin weak layer and water at the colluvium/rock contact control slope stability; talus may sit at FS ≈ 1. Use test pits, trenches, and surface-wave geophysics for talus thickness.
Shale, claystone and other degradable rockRock-like in place, needs coring; drilling water starts degradationRockfill or cut faces degrade on wetting; slope stability decreases progressively.
Cemented sandsHigh blow counts / refusal look like dense sand; coring water may dissolve binderBrittle; collapse if the cement is soluble; long-term strength may drop to uncemented sand.
Sensitive (quick) claysMetastable structure makes undisturbed sampling difficult; may need foil or block samplerCan fail with little or no warning.

For these materials, plan test pits or block samples, triple-tube coring, or in-situ tests (Chapter 5.1) rather than relying on SPT and Shelby tubes.

Source: Sabatini, P. J. et al. (2002). Evaluation of Soil and Rock Properties. Geotechnical Engineering Circular No. 5, FHWA-IF-02-034 (superseded by GEC 5, Geotechnical Site Characterization, FHWA-NHI-16-072 (2017))