A clay sample from the cut slope of a Class I railroad has the Atterberg limits, water content and clay fraction shown. The engineer must classify the clay, compute its activity and liquidity index, and say what they suggest about the clay’s history and behavior in the cut.
Three index properties that together say what kind of clay this is and what state it is in.
| Variable | Value | Description |
|---|---|---|
| LL, PL | 52 and 24 | Atterberg limits |
| wn | 30% | Natural water content |
| CF | 40% | Finer than 2 μm |
CH (fat clay); activity 0.70; liquidity index 0.21.
A water content this close to the plastic limit suggests the clay is overconsolidated or desiccated. It will be stiff in its present state but can soften if it gets wetter, which matters for cut slopes and subgrades exposed to water (Question 2.5-3).
A Class I railroad embankment over normally consolidated clay is to be raised. Field vane tests gave the strength shown at a depth where the effective stress is known. The engineer must find the design undrained strength for the stability analysis and check it against a SHANSEP estimate.
Field vane tests in plastic clays overestimate the strength that is mobilized in an embankment failure. Bjerrum’s correction reduces the vane value; SHANSEP gives an independent estimate from the effective stress.
| Variable | Value | Description |
|---|---|---|
| PI | 40 | Plasticity index |
| su,VST | 600 psf | Field vane strength |
| σ′v0 | 2,500 psf | Effective stress at the test depth |
| OCR | 1.0 | Normally consolidated |
| S | 0.22 | SHANSEP strength ratio |
Design su ≈ 500 psf. SHANSEP gives 550 psf, within 10%.
Two independent methods agreeing within 10% is good confirmation. Use the lower, vane-based value for design; the agreement shows the vane results are not disturbed or affected by sand layers.
A cut in stiff fissured clay on a Class I railroad stood for 40 years and then failed onto the track. The railroad needs a repair design and asks why the original cut failed. The engineer must say which drained strength the original design should have used and which the repair must use.
A reasoning question about the three drained strengths of a stiff clay: peak, fully softened and residual. Each applies to a different stage in the life of a slope.
| Variable | Value | Description |
|---|---|---|
| Soil | Stiff fissured clay; LL = 75, clay fraction 55% | High plasticity |
| History | The cut stood 40 years, then failed | Delayed failure |
| Strengths | Fully softened about 18° to 25°; residual about 9° to 16° (c′ = 0) | Table 2.5-7 |
No equation is needed; the answer follows from the criteria listed under Given.
The original design should have used the fully softened strength (about 18° to 25°, c′ = 0). The repair must use the residual strength on the existing slip surface (about 9° to 16°).
The 40-year delay is typical of cuts in stiff plastic clay and is the reason peak strengths are not used for permanent cuts. Once a slip surface exists, it does not regain strength, so a repair that assumes the fully softened strength will fail again on the same surface.