Formerly Geo Rail Chapter 6.3 — Railroad Track Subgrade: Special Topics
GPR is an efficient, non-destructive tool for mapping ballast fouling, subballast thickness, and subgrade moisture conditions along track. It is common practice for mainline rehabilitation investigations.
GPR uses an antenna (typically 400 MHz or 1 GHz) mounted on a hi-rail vehicle to transmit and receive electromagnetic pulses through the track structure. Reflections at material boundaries provide:
The depth to a reflector:
d_GPR = (v × t_twtt) / 2 (ft)
where:

| Material | ε_r | Wave Velocity (ft/ns) |
|---|---|---|
| Clean ballast, dry to moist (measured) | 3–4 | 0.492–0.568 |
| Clean granite ballast (value often assumed in practice) | 5–6 | 0.402–0.440 |
| Moderately fouled ballast | 8–12 | 0.284–0.348 |
| Highly fouled/saturated | 15–30 | 0.180–0.254 |
| Subballast (granular, dry) | 6–9 | 0.328–0.402 |
| Clay subgrade (moist) | 20–40 | 0.156–0.220 |
| Ballast voids/air | 1 | 0.984 |
Note: the clean-ballast row was revised to the measured values of 3 to 4 (Table 2.3-25 at the end of this section). The 5 to 6 often assumed is kept for comparison. Calibrate each survey at crib digs or by CMP.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| v | electromagnetic wave velocity in ballast (ft/ns) | Field test (geophysics) | From the dielectric constant, v = c/√εr, or measured directly by a common-midpoint (CMP) or wide-angle GPR survey (ASTM D6432). | project-specific |
| c | speed of light = 0.984 ft/ns | Constant | Physical constant or standard value. | project-specific |
| εr | relative dielectric constant of ballast (clean ballast: ε_r ≈ 3–4 measured, 5–6 often assumed) | Field test (geophysics) | Back-calculated at a crib dig or boring of known depth, εr = (c·t/2d)2, or from a CMP survey. Laboratory values by ballast type, fouling and moisture are in Table 2.3-26. | ≈ 3–4 clean (measured); calibrate |
| ttwtt | two-way travel time (ns) from radar trace | Field test (geophysics) | Read from the GPR record (ASTM D6432). Where the fouled zone has no sharp interface, use the depth of the energy drop on a short-time Fourier transform (STFT) plot. | project-specific |
Standard GPR deliverables for railroad geotechnical investigations:
Correlate GPR survey results with field-verified boring data before design recommendations are finalized.
GPR on track is harder than on pavement. The rails and ties, especially concrete ties, and nearby electrical wires interfere with the signal, and dense sampling at track speed was long a problem for scheduling (Saarenketo, in Jol 2009). Experience summarized from North America and Europe:
| Condition | Clark et al. (2001) | Sussmann et al. (2002), granite |
|---|---|---|
| Dry clean ballast | 3 | 3.6 |
| Moist clean ballast | 3.5 | 4 |
| Dry spent (fouled) ballast | 4.3 | 3.7 |
| Moist spent ballast | 7.8 | 5.1 |
| Wet spent ballast | 38.5 | 7.2 |
These measured values for clean ballast (3 to 4) are now the clean-ballast row of Table 2.3-6, which previously gave 5 to 6. Using 5 to 6 for clean, dry ballast underestimates the velocity and therefore the ballast thickness by roughly 10 to 30%. Use crib-dig or CMP calibration for each survey rather than either table. The two studies also differ widely for wet spent ballast (7 to 39), which shows how much the value depends on the fines, the water and the measurement.
For railroad work: Ask the GPR contractor which antennas will be used and why, how the dielectric value will be calibrated (CMP, crib digs or both), and whether lines will be run outside both rails as well as at the center. Schedule ballast-thickness surveys for frozen, dry or at least stable moisture conditions, and repeat surveys in the same season so the results can be compared. Treat a sharp difference between the three lines as a reason for a crib dig or boring at that location.
Source: Saarenketo, “NDT Transportation,” in Jol (ed.) (2009), Ch. 13, Section 13.8 and Table 13.3. Summarized and paraphrased; particle size converted. Full reference under S19.
A GPR depth is only as good as the dielectric constant used to convert travel time to depth. In practice that value is rarely known, and the change from clean to fouled ballast is usually gradual, so it may give no reflection at all. The study summarized here measured the dielectric constant of two ballast types in the laboratory, then used a time–frequency method to find fouling that does not show as a reflector.
Laboratory set-up. Two wooden boxes, 5 × 5 × 4 ft, were built with fiberglass screws so that no metal disturbed the signal. Each was filled with uniformly graded 2.5-in. granite or limestone ballast, oven-dry, compacted to 36.3% air voids (granite) and 37.8% (limestone). Data were collected with 2-GHz air-coupled horn antennas. The ballast was placed in 12-in. lifts. Dry clay was worked into the bottom lift at 10, 25, 40 and 50% of its void volume, clean lifts were added on top to a total of 36 in., and water was then sprayed into the bottom lift at up to 50% of its void volume. The layer thickness was measured at the box corners, so the dielectric constant could be back-calculated from the two-way travel time:
εr = (c · t / 2d)2
where c = 0.984 ft/ns, t = two-way travel time through the layer (ns) and d = layer thickness (ft). This is the depth equation of Section 2.3.9.2 solved for εr, and it is the same calculation used to calibrate a survey at a crib dig (Example 2.3-8).
| Ballast | Condition varied | Fitted line | R2 | εr over the tested range |
|---|---|---|---|---|
| Granite | Dry clay fouling F = 0 to 0.50 | εr = 3.24 + 1.04 F | 0.987 | 3.24 to 3.76 |
| Limestone | Dry clay fouling F = 0 to 0.50 | εr = 3.73 + 1.63 F | 0.993 | 3.73 to 4.55 |
| Granite, 13% fouled | Water W = 0 to 0.15 | εr = 3.96 + 31.9 W | 0.939 | about 3.9 to 9.1 |
| Limestone, 13% fouled | Water W = 0 to 0.15 | εr = 4.57 + 39.9 W | 0.980 | about 4.2 to 10.5 |
F = volume of dry clay as a fraction of the ballast void volume; W = volume of water as a fraction of the void volume. The ranges in the last column for moisture are those reported in the text of the paper; the fitted lines give 3.96 to 8.7 for granite and 4.57 to 10.6 for limestone. The paper’s conclusions give 3.96 to 4.84 for dry limestone over 0 to 50% fouling, which does not agree with its own fitted line (3.73 to 4.55); the granite range (3.25 to 3.77) does agree. Use the fitted lines, and read the 0.3 difference as a guide to how closely these values can be relied on. The moisture series also starts higher than the fouling line gives at 13% (3.37 granite, 3.94 limestone) because it was measured on the full 36-in. layered box. All of this is another reason to calibrate each survey rather than take a value from a table.
What the measurements show:
Reading fouling from a time–frequency plot. A short-time Fourier transform (STFT) breaks the radar trace into short time windows and plots the energy at each frequency against travel time, which converts to depth with the calibrated εr. Three signatures were found (Figure 2.3-74):
Antenna frequency. The voids in clean 2.5-in. ballast are about the size of the wavelength at 2 GHz (about 3.3 in. in clean, dry granite, where v ≈ 0.55 ft/ns), so the voids scatter the 2-GHz signal and that scatter is itself a sign of clean ballast. At 1 GHz the wavelength is about twice as long and the void scatter is barely visible. Choose 2 GHz where ballast condition is the question and lower frequencies (400 MHz to 1 GHz) where layer thickness and the subgrade are the question.
Field check. Data were collected on a main line of a Class I railroad located in eastern Wyoming, with granite ballast, using 2-GHz air-coupled antennas on a hi-rail vehicle. To reduce reflections from the rails and ties the antennas were carried 2 ft outside the rails, so the records are of the ballast shoulder. Shoulder samples were taken at 6-in. depth intervals for moisture and gradation, and the STFT depths were computed with the laboratory dielectric constant for the measured moisture. Table 2.3-27 compares the two.
| Case | 0–6 in. | 6–12 in. | 12–18 in. | 18–24 in. | 24–30 in. | 30–36 in. | STFT signature |
|---|---|---|---|---|---|---|---|
| 1 | 1.7 | 1.1 | 2.8 | 7.8 | 75 | 82 | Energy drop from about 25 in. to 36 in. |
| 2 | 0 | 0.2 | 106 | 87 | – | – | Energy drop at about 15 in.; high-energy zone at about 20 in. (rain before the survey) |
| 3 | 9.2 | 5.9 | 19.3 | – | – | – | Energy drop at about 17 in. |
| 4 | 5.6 | 5.0 | 13.8 | 34.8 | – | – | Small drop at 11 to 14 in.; large drop at about 18 in. |
FI = P4 + P200 (Table 2.3-5). The paper classes FI below 10 as clean, 10 to 20 as moderately fouled and above 20 as seriously fouled. FI can exceed 100 because the No. 200 fraction is also counted in P4. A dash means no sample at that depth.
In every case the energy drop fell in or at the top of the first sample interval classed as moderately or seriously fouled. Because each sample covers 6 in., a high FI shows fouling somewhere in that interval, not at its top. The GPR energy drop may locate the top of the fouling more closely than the samples do.
Limits. The authors warn against overselling the method. Noise from rails, ties and radio signals can hide the ballast information, and the STFT reading assumes a clean record. The laboratory fouling was dry clay; fines from ballast breakdown, coal dust or a pumping subgrade will give other values. The field records were taken on the shoulder, not under the ties. And without a good dielectric constant the depth of the energy drop is no better than the assumed value.
For railroad work: Ask the GPR contractor what dielectric constant was used for each reach and why, and require it to be calibrated at crib digs in each ballast type and moisture condition on the job. Ask for STFT (or similar time–frequency) plots where the clean-to-fouled change is gradual, and have energy drops and high-energy zones entered on the anomaly log (Section 2.3.9.3), with the high-energy zones treated as trapped water and a drainage question. Compare dry-season and wet-season surveys only if the calibration was repeated. Before setting an undercut depth from GPR, confirm the depth at a crib dig or boring, sampling in intervals of 6 in. or less.
Source: Leng, Z. and Al-Qadi, I. L. (2010). “Railroad Ballast Evaluation Using Ground-Penetrating Radar: Laboratory Investigation and Field Validation.” Transportation Research Record 2159, 110–117, Eqs. 1–5, Figs. 7–9, 11, Table 1. Summarized and paraphrased; fitted lines rounded and moisture and fouling expressed as fractions of void volume. Full reference under S5.
A Class I railroad located in Nebraska is planning an undercutting program on a granite-ballasted main line, and a 2-GHz hi-rail GPR survey has been run. Where the fouling is gradual there is no clear reflector, so the depth to the top of the fouled ballast is read from the energy drop on the STFT plot. The contractor converted travel time to depth with an assumed dielectric constant of 5.5. A crib dig at Station A found 14 in. of clean ballast over fouled ballast, and the energy drop there is at a two-way travel time of 4.5 ns. At Station B the drop is at 6.2 ns. The engineer must calibrate the dielectric constant at the dig, find the depth to fouling at Station B, and say how far the contractor’s depth is off.
| Variable | Value | Description |
|---|---|---|
| dA | 14 in. = 1.167 ft | Clean ballast thickness measured in the crib dig at Station A |
| tA | 4.5 ns | Two-way travel time to the energy drop at Station A |
| tB | 6.2 ns | Two-way travel time to the energy drop at Station B |
| εr,assumed | 5.5 | Dielectric constant assumed by the GPR contractor |
| c | 0.984 ft/ns | Speed of light |
| Reference values | Tables 2.3-25 and 2.3-26 | Measured dielectric constants of clean ballast |
(a) εr = 3.60. (b) v = 0.518 ft/ns. (c) The top of the fouled ballast at Station B is 19.3 in. below the top of ballast. (d) With the assumed 5.5 the contractor reports 15.6 in., 3.7 in. (19%) too shallow. (e) The calibrated value is within the range measured for clean, slightly moist ballast.
An error of this size matters for undercutting: a cut set from the contractor’s depth would leave about 4 in. of fouled ballast in place. Because depth scales with 1/√εr, every survey reach needs its own calibration where the ballast type or moisture changes. Granite and limestone differ, and a rain before the survey can raise the value sharply (Table 2.3-26). Here a higher value than 3.60 would make the depth at Station B shallower, and a lower value deeper. The calibration only holds for the clean layer above the energy drop. Below it the fouled ballast has a higher value, so do not use 3.60 to convert deeper reflectors such as the subballast interface. Confirm Station B with a second crib dig before the undercut depth is fixed.