The three examples cover the three questions most often asked of a track section: is the subgrade overstressed, how fouled is the ballast, and will frost reach the subgrade. Each is laid out as Given, Required, Equations, a flow chart of the steps with a spot check at each, and the Solution with what it means for the track.
Example 2.3-1: Stress at the Top of Subgrade Under a Heavy-Haul Main Line
A main line on a Class I railroad located in the Powder River Basin of Wyoming carries unit coal trains at 286,000-lb gross rail load. The client asks whether the subgrade is adequate for the existing section. The method spreads the wheel load through the ballast and subballast to the subgrade and compares the stress there with what the subgrade can carry under repeated loading.
Given and required for Example 2.3-1.
Given
Variable
Value
Description
Pw
40,000 lb
Cooper E-80 wheel load
DLF
1.4
Dynamic load factor (assumed for heavy tonnage)
db, dsb
18 in. and 6 in.; d = 2.0 ft
Ballast and subballast thickness
Bt
0.917 ft (11 in.)
Concrete tie width
Lt
8.5 ft
Tie length
θ
35° (tanθ = 0.700)
Load spread angle through the granular layers
su
350 psf
Subgrade undrained strength, average of five vane tests
FS
3.0
Factor of safety for cyclic loading
Required
Dynamic wheel load and stress at the top of subgrade
Allowable subgrade stress and whether the subgrade is adequate
The granular thickness needed if it is not
Equations
Eq. 1: Pd = Pw × DLF — dynamic wheel load
Eq. 2: Aeff = (Bt + 2d tanθ)(Lt + 2d tanθ) — area at the top of subgrade (Section 2.3.2)
Eq. 3: σs = P / Aeff — average vertical stress at the top of subgrade
Eq. 4: σallow = (π + 2) su / FS — allowable stress from undrained bearing capacity
Eq. 5: Solve (0.917 + 1.4d)(8.5 + 1.4d) = Pw / σallow for d — required total granular thickness
Spot check: Check the recommended 38 in. (3.17 ft): A = 5.35 × 12.93 = 69.2 ft²; 40,000 / 69.2 = 578 psf < 600 psf.
↓
Solution
Subgrade overstressed (ratio 0.63); about 37 in. of granular material is needed.
Solution
The subgrade is overstressed: 952 psf static against 600 psf allowable, a ratio of 0.63. About 3.1 ft (37 in.) of ballast, subballast and blanket is needed.
A common section of 12 in. of ballast over 8 in. of subballast (20 in.) is far short. One solution is 24 in. of ballast over a 14-in. granular blanket (38 in. total), which brings the static stress to 578 psf. Where that much section is impractical, improving the subgrade itself, for example by wick drains and preloading (Chapter 7.2), is the alternative. The example compares the allowable stress with the static load because the factor of safety of 3 already allows for repeated loading; using the dynamic stress as well would count the dynamic effect twice.
Example 2.3-2: Ballast Fouling Assessment Along a Segment
A main line segment on a Class I railroad located in Georgia was reported for track geometry deviations. Ballast was sampled at 500-ft intervals over two miles. A single sample says how fouled the ballast is at one point; the pattern along the line says where to clean, where to undercut and where to look deeper.
Given and required for Example 2.3-2.
Given
Variable
Value
Description
P4
14.2%
Percent passing the No. 4 sieve, representative sample
P200
3.8%
Percent passing the No. 200 sieve, same sample
Samples
Six stations at 0.3-mile spacing (table in Step 3)
Along-alignment results
Classes
Table 2.3-5
Clean, moderately clean, moderately fouled (10 to 20), fouled (20 to 40), highly fouled (40 or more)
Required
Fouling Index and class for the representative sample
The extent of ballast needing cleaning or undercutting
Equations
Eq. 1 (Selig): FI = P4 + P200 — Fouling Index
Steps
Step 1 · FI of the representative sample (Eq. 1)
14.2 + 3.8
FI = 18.0: moderately fouled, approaching the cleaning threshold of 20
↓
Step 2 · FI at every station
9.7, 18.0, 27.8, 40.6, 23.0, 13.7 (stations 1 to 6)
Spot check: Station 4: 31.4 + 9.2 = 40.6; station 3: 22.1 + 5.7 = 27.8.
↓
Step 3 · Extent above the threshold
Stations 3 to 5 have FI ≥ 20
0.6 mile needs cleaning or undercutting; station 4 (FI 40.6) needs a subgrade investigation
↓
Solution
Representative FI = 18.0; 0.6 mile fouled, peaking at FI 40.6.
Solution
The representative sample has FI = 18.0, moderately fouled. Three consecutive stations are fouled or highly fouled, a 0.6-mile reach that needs ballast cleaning or undercutting.
The peak at station 4 is highly fouled and is the place to look for a ballast pocket or pumping subgrade; three borings there would tell whether undercutting alone is enough. Fouling that rises to a peak and falls again usually has a local source, such as a pumping subgrade or a drainage low point, rather than ballast wear, which is more uniform. At highly fouled locations track modulus often falls below 2,000 psi (Table 2.3-23); confirm it with a deflection measurement before designing the repair.
Example 2.3-3: Frost Blanket for a Frost-Susceptible Subgrade
A main line on a Class I railroad located on the Manitoba prairie crosses lacustrine clay and till, and track geometry defects appear every spring. The aim is to keep the freezing front out of the frost-susceptible subgrade. The example uses a simplified form of the modified Berggren equation; a full design uses the method of Chapter 7.3.
Given and required for Example 2.3-3.
Given
Variable
Value
Description
FIair
2,800 °F·days
Design freezing index (assumed from climate data)
Existing section
12 in. ballast + 6 in. subballast = 1.5 ft
Non-frost-susceptible cover over the subgrade
Subgrade
Frost-susceptible till, group F3
Chapter 7.3
λ
1.50 in./(°F·day)0.5
Assumed coefficient for granular fill; check against Chapter 7.3
Insulation
2 in. XPS, equivalent to about 2.5 ft of granular fill (assumed)
Optional
Criterion
The 32°F isotherm stays above the top of the subgrade
Design requirement (assumed)
Required
Frost penetration depth
Blanket thickness needed, with and without insulation
Spot check: 1.5 + 2.5 + 2.6 = 6.6 ft, the full penetration depth.
↓
Solution
31 in. of non-frost-susceptible blanket over 2 in. of XPS insulation.
Solution
Frost penetrates about 6.6 ft. Provide 31 in. of non-frost-susceptible (NFS or F1) granular blanket over 2 in. of XPS insulation board, below the existing subballast.
Without insulation the blanket would have to be over 5 ft thick, which is rarely possible under an operating track. Insulation trades thickness for cost and for a stiffness discontinuity at its ends, which needs tapering. The stress at the top of subgrade must still be checked with the new section (Example 2.3-1). Frost blanket designs are normally submitted under a professional engineer’s seal.