Formerly Geo Rail Chapter 6.3 — Railroad Track Subgrade: Special Topics
AREMA MRE Chapter 1, Table 1-2-2 defines the standard ballast gradations. Numbers 24, 25, 3, 4A and 4 are main-line gradations; Numbers 5 and 57 are yard gradations. Two of the main-line gradations:
| Sieve Size | AREMA No. 4, 1½–¾ in. (% Passing) | AREMA No. 24, 2½–¾ in. (% Passing) |
|---|---|---|
| 3 in. | — | 100 |
| 2½ in. | — | 90–100 |
| 2 in. | 100 | — |
| 1½ in. | 90–100 | 25–60 |
| 1 in. | 20–55 | — |
| ¾ in. | 0–15 | 0–10 |
| ½ in. | — | 0–5 |
| ⅜ in. | 0–5 | — |
AREMA No. 24 (2½–¾ in.) and No. 4A (2–¾ in.) are the coarser main-line gradations commonly used for heavy-axle freight. No. 4 (1½–¾ in.) is the smallest main-line gradation. Confirm the gradation against the owner railroad's specification.
Per AREMA Chapter 1, Part 2, Table 1-2-1 (Section 2.3.3):
These requirements vary by owner railroad. Confirm them against the owner railroad's current standards when the work is scoped, and record the edition used.
Petrography first. A thin-section examination flags rock that will break down in track whatever the index tests say. Selig and Waters list these “fatal flaws” (after Watters et al.):
Abrasion tests measure different things.
In an AAR test on a Class I railroad at about 300 MGT per year, fouling (minus No. 4) grew 0.4–0.6% per year, and 75–90% of it came from ballast breakdown. Fouling correlated with AN.
Shape. AREA adopted the Corps definitions in 1986: flat means thickness ÷ width < 1/3, and elongated means length ÷ width > 3, with a limit of 5% by weight. Flaky, angular particles raise shear strength, but they also break more, accumulate more permanent strain and lower stiffness.
Gradation. In laboratory tests, uniform ballast (Cu 1.14) showed about twice the plastic strain and 4–5 times the degradation of a broader gradation (Cu 4.1). The broader grading is stronger and settles less. But it has less void space to store fines, it can segregate, and it is more susceptible to fouling. The railroad ranks coarse uniform gradations best for fouling life, then fine uniform, then broad. The book finds no basis for a single optimum size. Durability and room to store fines govern.
Other indicators. Higher specific gravity goes with durability. Low absorption goes with weathering resistance. Higher rodded unit weight goes with lateral stability. Where limestone or other soft stone sits in wet track, a wet attrition (Deval) test is worth requesting. British Rail limited it to 4%.
After Selig & Waters (1994), chs. 3, 7 and 8. Full reference under Supplemental References.
Section 2.3.3.2 gives the AREMA limits. Li et al. (2016) add two screens that are worth requesting when qualifying a new quarry: the Mill Abrasion test (Selig & Waters, 1994), which wears the stone in water and is more sensitive than LA Abrasion to the soft, clay-bearing rocks that turn to mud in track, and petrographic analysis of the parent rock. The railroad's limits show how far a freeze–thaw railroad tightens the AREMA values:
Table 2-S2. AREMA vs. Class I railroad ballast limits (Li et al., 2016, Table 3.3)
| Test | Procedure | AREMA | Class I railroad |
|---|---|---|---|
| Los Angeles Abrasion | ASTM C535 | 35% max. | 45% max. (paired with Mill Abrasion) |
| Mill Abrasion | Selig & Waters (1994) | – | 9% max. |
| Absorption | ASTM C127 | 1.0% max. | 0.5% max. |
| Sulfate soundness | ASTM C88 | 5.0% max. | 1.0% max. (mainline) |
Table 2-S3. Rock properties that lead to poor ballast performance (after Watters et al., 1987)
| Rock property | Deterioration problem |
|---|---|
| Soft minerals (e.g., clay shale) | Rapid wear and crushing |
| Minerals that weather or deteriorate rapidly | Weathering of the stone in track |
| Poorly consolidated texture | Rapid abrasion |
| High porosity | Freeze–thaw deterioration |
| Smooth particle surface | Poor stability |
| Long, flat particle shape | Poor stability; breakage of elongated pieces |
Li et al. recommend petrographic analysis of the parent rock whenever a new source is being qualified, because it shows secondary minerals and textures that the index tests can miss.
Source: Li, D., Hyslip, J., Sussmann, T. and Chrismer, S. (2016). Railway Geotechnics. CRC Press / Taylor & Francis
The European standard designates ballast by a pair of sieve sizes, 1¼ in. lower and 2 in. or 2½ in. upper, and lets the supplier declare a category for each property. The Los Angeles test is the reference hardness test (in the EN version: 22-lb sample, 1,000 revolutions at 31–33 rpm). Many older regulations simply require LA < 25.

| Los Angeles coefficient | Category | Micro-Deval coefficient | Category |
|---|---|---|---|
| ≤ 12 | LARB12 | ≤ 5 | MDERB5 |
| ≤ 14 | LARB14 | ≤ 7 | MDERB7 |
| ≤ 16 | LARB16 | ≤ 11 | MDERB11 |
| ≤ 20 | LARB20 | ≤ 15 | MDERB15 |
| ≤ 24 | LARB24 | > 15 | declared |
| > 24 | declared |
| Property | Category limits |
|---|---|
| Fine particles (passing No. 35) | A: 0.6% · B: 1.0% · declared > 1.0% |
| Fines (passing No. 230) | A: 0.5% · B: 1.0% · C: 1.5% · declared > 1.5% |
| Flakiness index | ≤ 15, ≤ 20, ≤ 35, declared > 35 |
| Shape index | ≤ 10, ≤ 20, ≤ 30, 5–35, declared > 30 |
| Particles ≥ 4 in. long (sample > 88 lb) | A: 4% · B: 6% · C: 8% · D: 12% |
Deval requirements in older regulations range from a coefficient greater than 12 (limestone) or 14 (hard rock) to greater than 16, which may exclude limestone and push a railway toward granite. French practice requires the LA and Deval results to plot together inside an acceptance band (Figure 2.3-18).


After Profillidis (2014), §12.2–12.4, Tables 12.2–12.9, Figs. 12.1, 12.5; after EN 13450 (2002). Full reference under Supplemental References.
Lateral (transverse) track resistance has three parts: friction under the tie (proportional to tie weight), friction along the tie sides from crib ballast, and passive resistance at the tie ends from the shoulder. The crib component is about 40–50% of the total for timber ties, 30% for monoblock concrete and 15–25% for twin-block ties, so under-filled cribs cost timber track the most.





These numbers explain why slow orders follow surfacing and undercutting, and why shoulder width and crib fill should be checked wherever a ground-hazard repair has disturbed the ballast section.
After Profillidis (2014), §13.3–13.6, Figs. 13.2, 13.3, 13.6, 13.7. Full reference under Supplemental References.
Ballast does six jobs: drainage, load distribution, vertical stiffness, longitudinal hold, lateral hold, and making surfacing practical. Failure of a function shows in the geometry: 2.5 in. or more of rail deflection at a joint means load distribution has failed, uneven support shows as cross-level, and ballast plowed in the direction of travel means it is too fine to hold the track. Judge ballast by digging, not by the surface.

Ballast shear strength comes from friction, which depends on size, angularity and interlocking. Prefer hard, dark, fine-grained extrusive rock (andesite, basalt, micro-diorite). Limestone, quartz, metamorphic rock and shale are unsuitable, and soft rock can grind into a mud spot within 2–3 years. Ballast life is roughly 200–900 MGT depending on rock type: some limestone lasts about 300 MGT, andesite about 900 MGT.

Shoulder width is a standard to enforce, not tolerate. A minimum 12-in. shoulder is what holds the ties laterally, and inadequate shoulders can contribute to derailments.
After Geotechnology for Railroaders Program, Module 3, Module 2; Module 3 §04–05, §11; after Selig & Waters (1994). Full reference under Supplemental References.
Seeley’s chapter on measuring rail track (CESMM3 Class S) sets out conventions that carry over to North American work:
His example is 492 ft of straight single track with ballast 10.33 ft wide, a 6-in. bottom ballast layer and about 5 in. of top ballast, timber ties at 29.5-in. centers, and 113 lb/yd rail.
Table 2-PM1. Table: Take-off for 492 ft of single track (after Seeley 1993, Example XVIII, converted to US units)
| Item | Calculation | Quantity |
|---|---|---|
| Bottom ballast | 492 × 10.33 × 0.49 ft | 92.7 CY |
| Top ballast (no deduction for ties) | 492 × 10.33 × 0.43 ft | 80.3 CY |
| Ties | 492 ft / 2.46 ft + 1 | 201 each |
| Rail, supply only | 2 rails × 492 ft at 113 lb/yd | 18.5 tons |
| Track laying | centerline length | 492 ft |
Seeley’s example, converted from metric, shows the measurement conventions in Section 2.4 applied to a short length of track. The take-off is the first step of any ballast or tie cost estimate (Chapter 3.7).
| Variable | Value | Description |
|---|---|---|
| L | 150 m = 492.1 ft | Length of straight single track |
| w | 3.15 m = 10.34 ft | Ballast width |
| tb | 0.15 m = 0.492 ft | Bottom ballast thickness |
| tt | 0.13 m = 0.427 ft | Top ballast thickness |
| s | 0.75 m = 2.46 ft | Tie spacing |
Bottom ballast 92.7 CY; top ballast 80.3 CY; 201 ties.
Rounded US dimensions (0.49 and 0.43 ft) give slightly different volumes; carry the unrounded conversions when checking a converted example. Top ballast is measured without deducting the ties, because the rate includes boxing and tamping around them.
For railroad work: when a geotechnical design calls for undercutting and new subballast and ballast, give the quantities in the same structure that the track contractor and the railroad’s material desk use. List separately:
State whether the ballast volume deducts the ties, and convert to tons with a unit weight measured for the actual quarry source. That way the engineer’s tonnage and the tonnage the railroad orders are computed on the same basis.
Source: Seeley, I. H. (1993). Civil Engineering Quantities, 5th ed. Basingstoke: The Macmillan Press, pp. 237–241. Summarized and paraphrased. Full reference under Supplemental References.