↑ Parent Menu⌂ Main Menu
← Chapter 2.3 Track Substructure: Ballast, Subballast and Subgrade
GHRM
Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · click a car to open it

2.3.17 Practice Questions

Formerly Geo Rail Chapter 6.3 — Railroad Track Subgrade: Special Topics

The track subgrade is the engineered foundation upon which the entire superstructure — rail, ties, ballast, and subballast — rests.
Authors: Daniel P. Colwell and Mario Ruel
2.3.17 Practice Questions
Each question is worked in the same five parts as the examples. Try it from the Given and Required before opening the steps.
Question 2.3-1: Stress at the Top of Subgrade

Problem Statement

A Class I railroad main line on concrete ties carries Cooper E-80 loading. The track section has 14 in. of ballast over 8 in. of subballast, and the railroad uses a dynamic load factor of 1.3. The engineer must find the dynamic wheel load, the effective loaded area at the top of subgrade and the vertical stress on the subgrade.

The same spreading method as Example 2.3-1, for a thinner section and a lower dynamic factor.

SubgradeballastsubballastPw = 40,000 lb, DLF 1.3Lt = 8.5 ft, Bt = 11 in.θ = 35°d = 1.833 ftAeff = ? σ = ?GivenCooper E-80 wheel 40,000 lbDLF = 1.3Ballast 14 in. + subballast 8 in.Concrete tie 11 in. × 8.5 ftθ = 35°Required(a) Dynamic wheel load(b) Effective area at subgrade(c) Vertical stressBlack = given; red = required
Given and required for Question 2.3-1.

Given

VariableValueDescription
Pw40,000 lbCooper E-80 wheel load
DLF1.3Dynamic load factor
d14 in. + 8 in. = 1.833 ftBallast plus subballast
Bt0.917 ft (11 in.)Concrete tie width
Lt8.5 ftTie length
θ35° (tanθ = 0.700)Load spread angle through the granular layers

Required

  • (a) Dynamic wheel load
  • (b) Effective area at the top of subgrade
  • (c) Vertical stress

Equations

  1. Eq. 1: Pd = Pw × DLF — dynamic wheel load
  2. Eq. 2: Aeff = (Bt + 2d tanθ)(Lt + 2d tanθ) — area at the top of subgrade (Section 2.3.2)
  3. Eq. 3: σs = P / Aeff — average vertical stress at the top of subgrade

Steps

Step 1 · (a) Pd (Eq. 1)
40,000 × 1.3
Pd = 52,000 lb
↓
Step 2 · (b) Aeff (Eq. 2)
2 × 1.833 × 0.700 = 2.566 ft; (0.917 + 2.566)(8.5 + 2.566) = 3.483 × 11.066
Aeff = 38.5 ft²
↓
Step 3 · (c) σs (Eq. 3)
52,000 / 38.5
σs = 1,349 psf = 0.67 tsf
Spot check: Example 2.3-1 had a thicker section and a larger DLF and gave a similar 1,333 psf; the two changes nearly cancel.
↓
Solution
(a) 52,000 lb; (b) 38.5 ft²; (c) 1,349 psf.

Solution

(a) Pd = 52,000 lb. (b) Aeff = 38.5 ft². (c) σs = 1,349 psf (0.67 tsf).

Whether 1,349 psf is acceptable depends on the subgrade strength, which is the subject of the next question.

Question 2.3-2: Is the Subgrade Adequate, and How Much Section Is Needed?

Problem Statement

A Class I railroad main line has been losing surface over a clay subgrade where vane tests found the undrained strength shown. Under the existing section the effective area at subgrade level is 42 ft². The engineer must check whether the subgrade is adequate for cyclic loading and, if not, find the granular thickness that would make it adequate.

A stiffer subgrade than Example 2.3-1, with the same section. The question runs the adequacy check and, because the check fails, solves for the thickness that would pass.

Clay subgrade, su = 500 psfballastsubballastPw = 40,000 lb (static)Aeff = 42.0 ft² (existing)θ = 35°d existingσ vs allowable = ?d to meet allowable = ?GivenStatic wheel 40,000 lbAeff = 42.0 ft²su = 500 psf; FS = 3.0Tie 11 in. × 8.5 ft; θ = 35°Required(a) Static stress(b) Allowable stress(c) Adequate?(d) Thickness d neededBlack = given; red = required
Given and required for Question 2.3-2.

Given

VariableValueDescription
su500 psfUndrained strength from vane tests
Pw40,000 lbStatic wheel load
Aeff42.0 ft²Effective area for the existing section
FS3.0For cyclic loading
Bt0.917 ft (11 in.)Concrete tie width
Lt8.5 ftTie length
θ35° (tanθ = 0.700)Load spread angle through the granular layers

Required

  • (a) Static stress
  • (b) Allowable stress
  • (c) Adequacy
  • (d) Thickness d that brings the stress to the allowable

Equations

  1. Eq. 1: σs = Pw / Aeff
  2. Eq. 2: σallow = (π + 2) su / FS
  3. Eq. 3: (0.917 + 1.4d)(8.5 + 1.4d) = Pw / σallow — solve for d

Steps

Step 1 · (a) Static stress (Eq. 1)
40,000 / 42.0
952 psf
↓
Step 2 · (b) Allowable stress (Eq. 2)
5.14 × 500 / 3.0
857 psf
↓
Step 3 · (c) Compare
952 > 857
Not adequate
↓
Step 4 · (d) Required area and thickness (Eq. 3)
A = 40,000 / 857 = 46.7 ft²; solve the quadratic
d = 2.22 ft (27 in.); use 30 in.
Spot check: At d = 2.22 ft: (0.917 + 3.11)(8.5 + 3.11) = 4.03 × 11.61 = 46.7 ft².
↓
Solution
Not adequate; about 27 in. of granular material is needed, so use 30 in.

Solution

(a) 952 psf. (b) 857 psf. (c) Not adequate. (d) d = 2.22 ft (27 in.); use 30 in.

Rounding up to 30 in. allows for placement tolerance and for ballast that will foul over time. The required thickness grows fast as the subgrade weakens: at su = 350 psf (Example 2.3-1) it was 37 in.

Question 2.3-3: Fouling Index of a Ballast Sample

Problem Statement

Track geometry has been deteriorating on a Class I railroad main line, and a ballast sample was taken from the crib. The gradation gave the percentages passing the No. 4 and No. 200 sieves shown. The engineer must compute the Fouling Index, classify the ballast and recommend maintenance action.

0102030P4 (No. 4)17.5%P200 (No. 200)4.2%Percent passing (crib sample)FI = ? Class = ? Action = ?GivenP4 = 17.5%P200 = 4.2%Fouled: FI 20 to 40 (Table 2.3-5)Required(a) Fouling Index(b) Class(c) Recommended actionBlack = given; red = required
Given and required for Question 2.3-3.

Given

VariableValueDescription
P417.5%Passing the No. 4 sieve
P2004.2%Passing the No. 200 sieve
ClassesTable 2.3-5Fouled: FI 20 to 40

Required

  • (a) Fouling Index
  • (b) Fouling class
  • (c) Recommended action

Equations

  1. Eq. 1: FI = P4 + P200

Steps

Step 1 · (a) FI
17.5 + 4.2
FI = 21.7
↓
Step 2 · (b) Class
20 ≤ 21.7 < 40
Fouled
↓
Step 3 · (c) Action
Schedule ballast cleaning; if geometry defects are present, investigate the subgrade with borings
↓
Solution
FI = 21.7, fouled: schedule cleaning.

Solution

(a) FI = 21.7. (b) Fouled. (c) Schedule ballast cleaning (undercutter-cleaner), and investigate the subgrade with borings if track geometry defects are present.

Cleaning restores drainage, but if the fines are coming up from a pumping subgrade they will return. Fines that match the subgrade soil, rather than ballast breakdown, are the sign to look below.

Question 2.3-4: Characteristic Length and Rail Bending Moment

Problem Statement

A Class I railroad main line with 136 RE rail runs on soft track with a modulus of 2,500 psi. The engineer must find the characteristic length of the rail and the maximum bending moment under a 40,000-lb wheel, and explain what soft track does to rail stress.

Soft trackPw = 40,000 lbsprings: track modulus ul = ? Mmax = ?Given136 RE rail, I = 95.0 in.⁴E = 30 × 10⁶ psiu = 2,500 psi (soft track)Pw = 40,000 lbRequired(a) Characteristic length l(b) Maximum rail momentBlack = given; red = required
Given and required for Question 2.3-4.

Given

VariableValueDescription
I95.0 in.4136 RE rail
E30 × 106 psiSteel
u2,500 psiTrack modulus
Pw40,000 lbWheel load

Required

  • (a) Characteristic length l
  • (b) Maximum rail bending moment

Equations

  1. Eq. 1: l = 1/β = (4EI / u)1/4
  2. Eq. 2: Mmax = P l / 4 — single wheel

Steps

Step 1 · (a) l (Eq. 1)
(4 × 30×106 × 95.0 / 2,500)1/4 = (4.56×106)1/4
l = 46.2 in.
Spot check: 46.24 = 4.56 × 106.
↓
Step 2 · (b) Mmax (Eq. 2)
40,000 × 46.2 / 4
Mmax = 462,000 in.-lb = 38,500 ft-lb
↓
Solution
l = 46.2 in.; M = 462,000 in.-lb.

Solution

(a) l = 46.2 in. (b) Mmax = 462,000 in.-lb (38,500 ft-lb).

Softer track (lower u) gives a longer characteristic length and so a larger moment: the rail spans further between effective supports. Compare Example 2.3-7, where u = 3,000 gives l = 44.1 in.

Question 2.3-5: Depth to a GPR Reflector in Ballast

Problem Statement

A hi-rail GPR survey on a Class I railroad main line recorded a strong reflector at a two-way travel time of 8.5 ns, and the ballast is estimated to have the dielectric constant shown. The design section has the ballast and subballast interface at 24 in. The engineer must convert the travel time to depth and say whether the result agrees with the design section.

GPR measures travel time, not depth. The depth depends on the wave velocity, which depends on the dielectric constant of the ballast, and the dielectric constant rises as the ballast fouls and holds water.

Ballast, εr = 6.5SubballastGPR antenna (hi-rail)t = 8.5 ns two-wayDesign interface 24 in.Depth = ? v = ?GivenTwo-way time t = 8.5 nsεr = 6.5c = 0.984 ft/nsDesign interface 24 in. (2.0 ft)Required(a) Wave velocity(b) Depth to reflector(c) Consistent with design?Black = given; red = required
Given and required for Question 2.3-5.

Given

VariableValueDescription
t8.5 nsTwo-way travel time to the reflector
εr6.5Estimated relative dielectric constant of the ballast
c0.984 ft/nsSpeed of light
Design24 in. (2.0 ft)Expected ballast/subballast interface depth

Required

  • (a) Wave velocity
  • (b) Depth to the reflector
  • (c) Whether the result is consistent with the design section

Equations

  1. Eq. 1: v = c / √εr
  2. Eq. 2: d = v t / 2 — two-way time, so halve

Steps

Step 1 · (a) v (Eq. 1)
0.984 / √6.5 = 0.984 / 2.550
v = 0.386 ft/ns
↓
Step 2 · (b) d (Eq. 2)
0.386 × 8.5 / 2
d = 1.64 ft = 19.7 in.
↓
Step 3 · (c) Compare
19.7 in. against 24 in.; εr of 6.5 lies between the clean (5 to 6) and moderately fouled (8 to 12) values of Table 2.3-6
Less ballast than designed, in near-clean ballast
↓
Solution
v = 0.386 ft/ns; d = 19.7 in., about 4 in. less than the design section.

Solution

(a) v = 0.386 ft/ns. (b) d = 1.64 ft (19.7 in.). (c) The reflector is about 4 in. shallower than the design interface.

Either the ballast has settled or the section was built thin. The depth also depends on the assumed dielectric constant: had the ballast been more fouled than assumed, the true depth would be shallower still. A correlation boring or test pit at the station calibrates the dielectric constant and confirms the layer thicknesses.

← Previous · 2.0 The Underworld Chapter 2.2 — Soil and Rock Classification
Next · 2.0 The Underworld → Chapter 2.4 — Silts: Properties, Typical Values and Liquefaction