6.6.10 Monitoring Existing Tunnels

Inspection, assessment, repair and clearance improvement of existing railroad tunnels and their portals.
Author: Daniel P. Colwell
6.6.10 Monitoring Existing Tunnels

Monitoring tells whether a defect is stable or getting worse, and how fast. The common tools for existing tunnels are:

  • Crack gauges and pins across cracks, read by hand or with a data logger. Record temperature with each reading, because cracks in linings open and close with the seasons.
  • Convergence measurements between pins on opposite walls and the crown, by tape extensometer or total station.
  • Repeat laser scanning, comparing scans to find deformation and changes in clearance over the whole surface ([S4], Ch. 18).
  • Fiber-optic strain sensing along the lining or in boreholes (Section 5.3.8), and tiltmeters on portals and walls.
  • Piezometers behind the lining where water pressure is suspected.
  • On-site visualization, with sensors that show their state by color at the instrument, so track crews see a change at once (Section 5.3.21).

Set alert and action levels for each instrument from the expected behavior and the consequences, tie each level to an action (more frequent readings, a slow order, closure and inspection), and give the plan to the dispatcher and track supervisor. Observation-based methods, in which measured deformation is back-analyzed to update the rock parameters and the support, are described by Sharifzadeh et al. ([S4], Ch. 15).

For railroad work: Readings are only useful if someone looks at them. Assign a responsible engineer for each monitored tunnel, plot each instrument against time with its alert and action levels, and review the plots on a set schedule and after any event. Use the trend, not a single reading, to decide what to do; see Question 6.6-1.