6.6.11 Risk Rating for Tunnels

Tunnels fit the GHRM risk framework of Chapter 3.8: a likelihood (frequency) rating from 1 to 5 for each element, a consequence (severity) rating, and a current risk from their combination. Table 6.6-5 gives the likelihood levels for the main tunnel elements, with the reasoning for each level.

Table 6.6-5. Likelihood ratings for tunnel elements (1 = very low, 5 = severe)
RatingLining (concrete, masonry)Unlined rockWater and icePortalRationale
1 Very lowSound; hairline cracks only; no voids foundMassive rock, Q > 10; no falls on recordDry or damp; no iceStable slopes; no rockfallNo defect that could develop into a failure within the inspection cycle.
2 LowMinor cracks and spalls; stable over several inspectionsQ 4–10; occasional small falls removed by scalingMinor drips; small ice removed routinelyMinor raveling caught by the ditchDefects present but stable; routine maintenance controls them.
3 ModerateCracks or spalls over the track; small voids; loose masonry unitsQ 1–4, or a weak bed or fault in otherwise good rock; repeated falls from one locationSteady leaks; ice in the clearance envelope some wintersRockfall reaching the track occasionally; old instabilityA defect that could reach the track or the train between inspections; needs a repair plan and closer inspection.
4 HighWidening crown cracks; delamination over the track; voids above the crown; lost mortar over large areasQ 0.1–1 without adequate support; recent falls onto trackHeavy inflow; ice in the envelope every winter; washing of finesActive slope movement above the portal; recent rockfall onto trackDeterioration is active and a failure affecting traffic is plausible within the next year; monitor and repair soon, with interim protection.
5 SevereArch deformation; new large cracks or spalling; falling materialQ < 0.1 unsupported, squeezing ground, or a fall that left an overhangInflow carrying sediment; ice blocking the envelopeMovement of the portal structure; large blocks perched above the portalFailure is likely or under way; restrict or stop traffic until made safe.

Consequence depends on train speed, traffic, whether passengers or hazardous materials are carried, the length of an outage (often much longer for a tunnel than for an open line), and whether a detour exists. Combine the ratings with the 5×5 matrix of Chapter 3.8. Risk reduction ratings for the chosen repair follow the same chapter.

For railroad work: Rate each tunnel by segment (portal zones, lining types, fault zones) rather than as a whole, because one bad segment controls the risk. Re-rate after every in-depth inspection and after any event, and feed monitored changes into the live rating described in Chapter 3.8.