i = Δh / L
Where Δh = head loss (ft) and L = seepage path length (ft).
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| Δh | head loss (ft) and L = seepage path length (ft). | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
v = k × i
v_a = k × i / n
Where n = porosity (dimensionless); typical values: gravels 0.25–0.40; sands 0.30–0.45; silts 0.35–0.50; clays 0.40–0.70.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| n | porosity (dimensionless) | Another equation | n = e/(1 + e), from the void ratio. | 0.25–0.55 for most mineral soils · by USCS group |
For embankment seepage with a defined flow net (N_f flow channels, N_d equipotential drops):
q = k × H × (N_f / N_d)
Where H = total head loss (ft); q = seepage flow per unit width of embankment (ft²/day).
Evaluate embankments next to waterways for seepage with a flow net or a numerical analysis when site-specific permeabilities are available, particularly at the approaches to scour-critical bridges.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| H | total head loss (ft) | Field or lab measurement | Recorded during the test or monitoring (readings, times, dimensions of the test setup). | project-specific |
Upward seepage beneath a railroad embankment or at the toe of a flood-side levee can cause piping or heave when the upward seepage force exceeds the submerged weight of soil:
i_cr = (G_s − 1) / (1 + e) = γ' / γ_w
Where:
For a typical medium sand (G_s = 2.65, e = 0.65):
i_cr = (2.65 − 1) / (1 + 0.65) = 1.65 / 1.65 = 1.00
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| icr | intermediate value computed on this page | Another equation | Computed: i_cr = (G_s − 1) / (1 + e) = γ' / γ_w | project-specific |
| Gs | specific gravity of solids (typically 2.65 for quartz sand) | Lab test | Specific gravity of solids (ASTM D854). 2.65–2.70 is usually adequate for mineral soils when untested. | 2.64–2.80 mineral; lower if organic · by USCS group |
| e | void ratio | Another equation | e = Gsγw/γd − 1, from Gs and γd; e0 for consolidation is reported by the consolidation test (ASTM D2435). | sands 0.35–0.85, clays 0.5–2.0 · by USCS group |
| γ' | buoyant unit weight (pcf) | Another equation | γ' = γsat − γw (γw = 62.4 pcf). Use below the water table. | 50–75 pcf for most mineral soils · by USCS group |
FS_piping = i_cr / i_exit
This manual recommends FS_piping ≥ 4.0 for permanent embankments adjacent to waterways where the exit is not protected by a filter. USACE EM 1110-2-1901 is written for dams and does not set a railroad criterion; state the criterion used.
AREMA MRE Chapter 8 addresses scour for foundations at waterway crossings; FHWA HEC-18 is the usual method. Total scour depth:
y_total = y_long + y_contr + y_local
Where:
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| ylong | long-term degradation scour (ft) — from channel bed trend analysis | Hydraulic study | From the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design. | project-specific |
y_s / y_1 = 2.0 × K₁ × K₂ × K₃ × K₄ × (a/y_1)^0.65 × Fr₁^0.43
Where:
Submit scour analysis results to the owner railroad's bridge engineering group. Railroad bridges are inspected at least annually under 49 CFR Part 237; for bridges the owner designates scour-critical, keep the scour evaluation and a monitoring plan in the bridge file.
| Symbol | What it is | Comes from | How to get it | Typical range |
|---|---|---|---|---|
| ys | pier scour depth (ft) | Hydraulic study | From the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design. | project-specific |
| y1 | flow depth directly upstream of pier (ft) | Hydraulic study | From the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design. | project-specific |
| K₁ | correction for pier nose shape (1.1 for square | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| K₂ | correction for angle of attack of flow | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| K₃ | correction for bed condition (1.1 for clear-water | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| K₄ | correction for armoring by bed material size | Chart, table or correction factor | Read from the cited chart or table for the site conditions; values listed in the definition. | project-specific |
| a | pier width (ft) | Project geometry | From project plans, survey and the design layout; layer depths and thicknesses from the boring logs. | project-specific |
| Fr₁ | Froude number at the pier = V₁ / √(g × y₁) | Hydraulic study | From the hydraulic model or study (HEC-RAS, FHWA HEC-18), stream gauge records or the drainage design. | project-specific |
| g | 32.2 ft/s² | Constant | Physical constant or standard value. | project-specific |
Water-laid soils are usually more permeable horizontally than vertically (wind-blown silts can be the reverse because of root holes). A flow net is only valid for isotropic conditions, so USACE draws it on a transformed section: multiply every horizontal dimension by √(kv/kh), draw a square flow net, then map it back to the true section. Seepage quantity uses the equivalent permeability k′ = √(khkv). Pore pressures and uplift can be read from either section, but gradients and seepage forces must be taken from the true section — the exit gradient in Eq. 2.8-16 is understated if it is scaled from the transformed net. Figure 9-S1 shows the same net for kh = kv, 4kv and 9kv.

At boundaries between soils of different permeability, flow channels narrow and equipotential spacing widens as water passes into the more permeable layer — head is lost mainly in the tighter soil.
USACE cites Cedergren’s case of a dam foundation logged from borings as uniform sandy gravel: lab tests on disturbed samples gave k ≈ 3 × 10−3 ft/day and a predicted underseepage of 3 ft3/day. The cutoff trench exposed streaks of openwork gravel (k ≈ 85,000 ft/day); without the cutoff, seepage would have been about 1,000,000 ft3/day. Grain-size sampling in drill holes washes out the very feature that controls flow. For railroad embankments beside rivers and at bridge approaches in alluvial gravel, rely on pumping tests and groundwater response to river stage, not lab permeability of disturbed samples. The reverse is also true: a thin continuous clay seam can control vertical flow through an otherwise pervious site.




Source: U.S. Army Corps of Engineers (1986, Change 1 1993). Seepage Analysis and Control for Dams. EM 1110-2-1901
A drain at the toe of an embankment, behind a wall, or around an edge-drain pipe must keep the protected soil in place while passing water. USACE EM 1110-2-1901 (App. D, adopted from the NRCS 1986 filter guide) sizes the filter from the protected (“base”) soil:

Table 9-S1. USACE filter criteria (d = base soil, D = filter)
| Base soil category | % finer than No. 200* | Retention criterion |
|---|---|---|
| 1 – fine silts and clays | > 85 | D15 ≤ 9 × d85 |
| 2 – sands, silts, clays, silty/clayey sands | 40–85 | D15 ≤ 0.028 in. |
| 3 – silty and clayey sands and gravels | 15–39 | D15 ≤ [(40 − A)/(40 − 15)] × [(4 × d85) − 0.028 in.] + 0.028 in. (A = % passing No. 200) |
| 4 – sands and gravels | < 15 | D15 ≤ 4 to 5 × d85 |
* After regrading the base soil on the minus No. 4 fraction when it contains gravel.
These criteria are more specific than the Terzaghi ratios used for subballast in Chapter 2.3 and are the ones to cite for edge drains, wall drains and toe filters in railroad embankments.
Source: U.S. Army Corps of Engineers (1986, Change 1 1993). Seepage Analysis and Control for Dams. EM 1110-2-1901
A head difference of more than about 6 ft across an embankment forces flow beneath the track. Seepage zones appear at the downhill toe within days, depending on fill permeability. Thin, permeable granular layers hidden in a fill can carry water deep into it unseen; an April 2013 slope failure followed exactly that path from a wet uphill ditch. Dirty or milky water and sand fans mean piping is underway. When seepage appears, do not plug it with clay. Let it out through ballast, geotextile and gravel so pressure cannot build.


After Geotechnology for Railroaders Program, Module 7.1, Module 4, Module 2; Module 7.1 §04–05; Module 4 §08; Module 2 §06. Full reference under Supplemental References.
The library's course notes on flow nets and on seepage through heterogeneous soil cover the three calculations most often needed when water stands against a railroad fill: the quantity of seepage, the exit gradient at the toe, and the equivalent permeability of a layered foundation. Layering matters more than any single permeability value: a thin sand seam under a clay-capped fill carries most of the flow and sets where it comes out.
Equation 2.8-21. Seepage from a flow net
Equation 2.8-22. Equivalent permeability of layered soil
Equation 2.8-23. Exit gradient and piping
| Result | Value |
|---|---|
| Equivalent kh / kv | 8.257 ft/day / 0.1847 ft/day |
| Seepage per foot | 3.293 ft³/day/ft |
| Total over 300 ft | 5.13 gpm |
| Exit gradient | 0.267 |
| FS against piping | 3.76 |
The layered foundation (sand over a thin clay over clean sand) has a horizontal permeability more than forty times its vertical value, so seepage concentrates in the lower sand and can surface beyond the toe. A factor of safety near 3.8 is adequate for this water level, but the chart in the calculator shows it falls below 3 if the pond rises a little over 2 ft, which is the kind of threshold that belongs in the site's live rating (Section 3.8.26).
Open the seepage calculator →
Flow-net seepage quantity, layered (anisotropic) permeability, exit gradient and factor of safety against piping, and a Hazen check of k from D10.
These documents are in the reference library. The method summaries above are paraphrased; equations are standard forms.