↑ Parent Menu⌂ Main Menu
← Chapter 2.8 Groundwater Characterization and Seepage
GHRM
Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · click a car to open it

2.8.4 Field Permeability Testing

Groundwater is the single most consequential subsurface variable in railroad geotechnical engineering.
Authors: Daniel P. Colwell and Mario Ruel
2.8.4 Field Permeability Testing
2.8.4.1 Slug Test — Rising Head (Bouwer-Rice Method)

Slug tests estimate the hydraulic conductivity (k) of the soil or rock at the piezometer screen interval by measuring the rate of water level recovery after a sudden injection or withdrawal of a known volume.

Equation 2.8-5 — Bouwer-Rice Method:

k = [r_c² × ln(R_e / r_w)] / [2 × L_e × t] × ln(y_0 / y_t)

Where:

  • k = hydraulic conductivity (ft/day)
  • r_c = casing radius (ft)
  • r_w = effective well radius including gravel pack (ft)
  • R_e = effective radius of influence (ft); estimated from Bouwer-Rice chart using H/r_w and (H − L_e)/r_w
  • L_e = length of screen (ft)
  • t = time elapsed from slug introduction (days)
  • y_0 = initial displacement from static water level (ft)
  • y_t = displacement at time t (ft)

Plot ln(y_t/y_0) vs. t; slope = −k × 2L_e / [r_c² × ln(R_e/r_w)].

Inputs: where each value comes from (8)
SymbolWhat it isComes fromHow to get itTypical range
k[r_c² × ln(R_e / r_w)] / [2 × L_e × t] × ln(y_0 / y_t)Field or lab testField: pumping test, slug test (ASTM D4044, withdrawn 2024) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only.clean sand 1–100, clay < 0.001 ft/day · by USCS group
rccasing radius (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
rweffective well radius including gravel pack (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Reeffective radius of influence (ft)Chart, table or correction factorRead from the cited chart or table for the site conditions; values listed in the definition.project-specific
Lelength of screen (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
ttime elapsed from slug introduction (days)TimeElapsed test time (recorded) or the analysis time chosen for design.project-specific
y0initial displacement from static water level (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
ytdisplacement at time t (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Constant Head Permeability Test
Constant Head Permeability Test
2.8.4.2 Constant-Head Test (ASTM D2434) — Granular Soils

For granular soils in the laboratory:

Equation 2.8-6 — Darcy Permeability (Constant Head):

k = Q × L / (A × Δh × t)

Where:

  • k = hydraulic conductivity (ft/s)
  • Q = volume of water collected (ft³)
  • L = specimen length (ft)
  • A = cross-sectional area of specimen (ft²)
  • Δh = head difference across specimen (ft)
  • t = collection time (s)
Inputs: where each value comes from (6)
SymbolWhat it isComes fromHow to get itTypical range
kQ × L / (A × Δh × t)Field or lab testField: pumping test, slug test (ASTM D4044, withdrawn 2024) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only.clean sand 1–100, clay < 0.001 ft/day · by USCS group
Qvolume of water collected (ft³)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Lspecimen length (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Across-sectional area of specimen (ft²)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Δhhead difference across specimen (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
tcollection time (s)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
2.8.4.3 Falling-Head Test (ASTM D5084) — Fine-Grained Soils
Equation 2.8-7 — Darcy Permeability (Falling Head):

k = (a × L / A × t) × ln(h₁ / h₂)

Where:

  • a = standpipe cross-sectional area (ft²)
  • h₁ = initial head (ft)
  • h₂ = final head after time t (ft)
  • L = specimen length (ft)
  • A = specimen cross-sectional area (ft²)
Inputs: where each value comes from (6)
SymbolWhat it isComes fromHow to get itTypical range
k(a × L / A × t) × ln(h₁ / h₂)Field or lab testField: pumping test, slug test (ASTM D4044, withdrawn 2024) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only.clean sand 1–100, clay < 0.001 ft/day · by USCS group
astandpipe cross-sectional area (ft²)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
h₁initial head (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
h₂final head after time t (ft)Field or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Lspecimen length (ft)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
Aspecimen cross-sectional area (ft²)Test setupDimension of the test equipment or specimen: from the test standard or the lab/field test record.project-specific
2.8.4.4 Pump Test (Theis / Cooper-Jacob Method)

For aquifer characterization on major railroad projects requiring dewatering design:

Equation 2.8-8 — Cooper-Jacob Straight-Line Method (Transmissivity):

T = 2.303 × Q / (4π × Δs)

Where:

  • T = transmissivity (ft²/day) = k × b (aquifer thickness b in ft)
  • Q = pumping rate (ft³/day; note: 1 gpm = 192.5 ft³/day)
  • Δs = drawdown per log cycle on s vs. log(t) plot (ft)
Inputs: where each value comes from (3)
SymbolWhat it isComes fromHow to get itTypical range
Tintermediate value computed on this pageAnother equationComputed: T = 2.303 × Q / (4π × Δs)project-specific
Qpumping rate (ft³/dayField or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Δsdrawdown per log cycle on s vsField or lab measurementRecorded during the test or monitoring (readings, times, dimensions of the test setup).project-specific
Equation 2.8-9 — Hydraulic Conductivity from Transmissivity:

k = T / b

Where b = saturated aquifer thickness (ft).

Inputs: where each value comes from (2)
SymbolWhat it isComes fromHow to get itTypical range
kT / bField or lab testField: pumping test, slug test (ASTM D4044, withdrawn 2024) or packer test. Lab: constant head (D2434) for sands, flexible-wall (D5084) for clays. Hazen k ≈ C·D102 for clean sands only.clean sand 1–100, clay < 0.001 ft/day · by USCS group
bsaturated aquifer thickness (ft).Project geometryFrom project plans, survey and the design layout; layer depths and thicknesses from the boring logs.project-specific
Equation 2.8-10 — Storativity (Confined Aquifer):

S = 2.25 × T × t₀ / r²

Where t₀ = time intercept where the Cooper-Jacob straight line intersects s = 0 on the time axis (days), and r = distance to observation well (ft).

Inputs: where each value comes from (1)
SymbolWhat it isComes fromHow to get itTypical range
t₀time intercept where the Cooper-Jacob straight line intersects s = 0 on the time axis (days), and r = distance to observation well (ft).TimeElapsed test time (recorded) or the analysis time chosen for design.project-specific
2.8.4.5 Typical Hydraulic Conductivity Values for Railroad Soils (English Units)
USCS SymbolSoil Typek (ft/day)k (ft/s)
GW, GPClean gravel100 – 3,0001.2×10⁻³ – 3.5×10⁻²
SW, SPClean sand10 – 3001.2×10⁻⁴ – 3.5×10⁻³
SMSilty sand0.3 – 103.5×10⁻⁶ – 1.2×10⁻⁴
MLSilt0.003 – 0.33.5×10⁻⁸ – 3.5×10⁻⁶
CLLean clay0.0003 – 0.013.5×10⁻⁹ – 1.2×10⁻⁷
CHFat clay< 0.0001< 1.2×10⁻⁹
Fractured rockVariable0.03 – 3003.5×10⁻⁷ – 3.5×10⁻³
Supplemental reference

Empirical k estimates — a check, not a design value

GEC 5 recommends estimating k from soil type and grain size before reducing test data, then treating any discrepancy of more than about two orders of magnitude as a sign of test error or unusual soil. Hazen’s equation, k (ft/day) = 2,835·C·d102 with C = 0.4–1.2 and d10 in mm, applies only to clean sands (< 5% passing No. 200, d10 = 0.0039–0.12 in.). Against slug tests in an alluvial sand aquifer, its error ranged from slight to more than one order of magnitude.

A continuous k profile from CPTu

Robertson and Cabal (2010) relate k to the soil behavior type index: k = 10(0.952 − 3.04 Ic) m/s for 1.0 < Ic ≤ 3.27, and k = 10(−4.52 − 1.37 Ic) m/s for 3.27 < Ic < 4.0. The relationship is approximate, but a CPTu profile shows thin pervious seams between piezometer screens that point tests miss. For soft clays (after Jamiolkowski et al., 1985) kh/kv is about 1–1.5 for homogeneous deposits, 2–4 for sedimentary clays with discontinuous pervious lenses, and 3–15 for varved clays with continuous pervious layers — the ratio needed for the transformed flow-net section above.

Source: Sabatini, P. J. et al. (2002). Evaluation of Soil and Rock Properties. Geotechnical Engineering Circular No. 5, FHWA-IF-02-034 (superseded by GEC 5, Geotechnical Site Characterization, FHWA-NHI-16-072 (2017)) · Robertson, P. K. and Cabal, K. L. (2010). Guide to Cone Penetration Testing for Geotechnical Engineering, 4th ed. Gregg Drilling & Testing

← Previous · 2.0 The Underworld Chapter 2.7 — Rock and Sand: Properties, Typical Values and Behavior
Next · 2.0 The Underworld → Chapter 2.9 — Collapsible Soils: Identification, Testing and Railroad Impacts