For Class I railroad mainline located in the prairies and Class I railroad operations located in Canada, frost susceptibility is a primary classification criterion. The U.S. Army Corps of Engineers frost susceptibility classification:
| FS Class | Description | Frost Heave Risk |
|---|---|---|
| FS-0 | Non-frost-susceptible | Negligible |
| FS-1 | Slightly frost-susceptible | Slight |
| FS-2 | Moderately frost-susceptible | Moderate |
| FS-3 | Moderately to highly frost-susceptible | High |
| FS-4 | Very highly frost-susceptible | Very High |
This manual labels the USACE frost groups FS-0 (NFS) and FS-1 to FS-4 (F1 to F4). Key criteria: GW, GP, SW, SP with < 3% finer than 0.02 mm = FS-0. All silts (ML, MH) = FS-4. Clays with PI > 12 = FS-3; lean clays with PI < 12 and varved clays = FS-4. In cold regions, assign a frost susceptibility class to all subgrade materials; Use a frost index analysis (freezing degree-days) together with the frost susceptibility class to set the minimum non-frost-susceptible ballast and subballast thickness.
The standard USACE groups (1965), which the FS classes above correspond to, are defined by the percent finer than 0.02 mm (20 μm), not the No. 200 sieve:
| Group | Soils |
|---|---|
| NFS | All soils with < 3% finer than 0.02 mm |
| F1 | Gravelly soils with 3–10% finer than 0.02 mm |
| F2 | Gravelly soils with 10–20% finer; sands with 3–15% finer than 0.02 mm |
| F3 | Gravelly soils > 20% finer; sands (except very fine silty sands) > 15% finer; clays with PI > 12 |
| F4 | All silts; very fine silty sands > 15% finer; lean clays with PI < 12; varved clays and other banded fine-grained sediments |
Susceptibility increases from F1 to F4. Carter and Bentley note that kaolinitic clays tend to heave more than montmorillonitic clays because water is more mobile in non-expanding clay structures — a counter-intuitive point when CH subgrade is assumed to be low frost risk. A quick screen (TRRL, 1970): granular soil with < 10% passing No. 200 is not susceptible; granular soil with > 10% fines or cohesive soil with PI < 20 is susceptible; cohesive soil with PI > 20 is not.
Confirm the frost-susceptibility classification with a hydrometer test, because the percent finer than 0.02 mm cannot be read from a sieve analysis.
Source: Carter, M. and Bentley, S. P. (2016). Soil Properties and their Correlations, 2nd ed. Wiley
Profillidis ranks silt as very frost-susceptible, clay as susceptible, and sand and gravel as not susceptible. Frost susceptibility is the third subgrade parameter, after soil class and hydrogeology, in climates where freezing is frequent. Protection is sized with the frost index ( Chapter 2.3, Section 2.3.5.3 ).
After Profillidis (2014), §9.4, §9.11.1. Full reference under Supplemental References.