↑ Parent Menu⌂ Main Menu
← Chapter 2.2 Soil and Rock Classification
GHRM
Railway Ground Hazard Risk Management · 2.0 · The Underworld
Sections · click a car to open it

2.2.13 Practice Questions

Consistent, reproducible classification of soil and rock is the common language shared between field personnel, laboratory technicians, design engineers, and railroad…
Authors: Daniel P. Colwell and Mario Ruel
2.2.13 Practice Questions
Each question is worked in the same five parts as the examples. Try it from the Given and Required before opening the steps. Question 2.2-5 is a reasoning question, so its steps are a chain of decisions rather than equations.
Question 2.2-1: Classify a High-Plasticity Clay

Problem Statement

A sample from the foundation of a Class I railroad embankment that is to be raised for a new grade has the gradation, Atterberg limits and water content shown. The engineer must classify the soil in both the USCS and AASHTO systems, find its liquidity index, and say what the results mean for carrying the added embankment load.

102030405060708090102030405060A-lineU-lineCLCHMLMH or OHLL = 50Liquid limit, LL (%)Plasticity index, PI (%)Foundation clay: LL 56, PI 32USCS = ?GivenF = 71% passing No. 200LL = 56%, PL = 24%PI = 32%wn = 41%Required(a) USCS group(b) AASHTO group and GI(c) Liquidity index, consistencyBlack = given; red = required
Given and required for Question 2.2-1.

Given

VariableValueDescription
F71%Percent passing No. 200
LL56%Liquid limit
PL24%Plastic limit
wn41%Natural water content

Required

  • (a) USCS group
  • (b) AASHTO group and GI
  • (c) Liquidity index and consistency

Equations

  1. Eq. 2.2-5: PI = LL − PL — plasticity index
  2. Eq. 2.2-8: PIA = 0.73 (LL − 20) — A-line: PI above it plots as clay (C), below as silt (M)
  3. Eq. 2.2-6: LI = (wn − PL) / PI — liquidity index
  4. Eq. 2.2-10: GI = (F − 35)[0.2 + 0.005(LL − 40)] + 0.01(F − 15)(PI − 10) — AASHTO group index; F = percent passing No. 200; a negative GI is reported as 0

Steps

Step 1 · Coarse or fine?
71% ≥ 50%
Fine-grained
↓
Step 2 · PI (Eq. 2.2-5)
PI = 56 − 24
PI = 32%
↓
Step 3 · A-line (Eq. 2.2-8)
PIA = 0.73 × (56 − 20) = 26.3%
PI > PIA and LL > 50: CH, fat clay
↓
Step 4 · AASHTO group
F > 35; LL > 40; PI > 10; PI = 32 > LL − 30 = 26
A-7-6
↓
Step 5 · GI (Eq. 2.2-10)
(71 − 35)[0.2 + 0.005 × 16] + 0.01 × 56 × 22 = 36 × 0.280 + 12.32 = 10.08 + 12.32
GI = 22.4, reported as 22
Spot check: AASHTO M 145 sets no upper limit on GI, so 22 is reported as computed.
↓
Step 6 · LI (Eq. 2.2-6)
LI = (41 − 24) / 32 = 17 / 32
LI = 0.53: medium consistency
↓
Solution
(a) CH; (b) A-7-6 (22); (c) LI = 0.53, medium.

Solution

(a) CH, fat clay. (b) A-7-6, GI = 22. (c) LI = 0.53, medium consistency.

The soil is highly plastic but not near its liquid limit, so it is not in an unstable state today. A GI of 22 is a very poor subgrade rating, and a fat clay foundation will consolidate under fill. Any embankment load over about 3 ft of fill warrants a settlement and ground improvement assessment (Chapters 6.2 and 7.2).

Question 2.2-2: Gradation Coefficients and the Dual Symbol

Problem Statement

A Class I railroad is building a new yard lead and wants to know whether the sand exposed at subgrade level can stay in place. A gradation test gave the grain sizes shown, with 9% non-plastic fines. The engineer must find the gradation coefficients, assign the USCS symbol, and comment on the sand as a track subgrade.

1001010.10.01020406080100No. 4No. 200D60 = 0.090 in.D30 = 0.019 in.D10 = 0.003 in.Cu, Cc, dual symbol ?Grain size (mm, log scale)Percent passingGivenD10 = 0.003 in. (0.076 mm)D30 = 0.019 in. (0.48 mm)D60 = 0.090 in. (2.3 mm)Fines F = 9%, non-plasticRequiredCu and CcUSCS dual symbolBlack = given; red = required
Given and required for Question 2.2-2.

Given

VariableValueDescription
D100.003 in.Grain size at 10% passing
D300.019 in.Grain size at 30% passing
D600.090 in.Grain size at 60% passing
F9%Fines content
LLNPFines are non-plastic

Required

  • Cu and Cc
  • USCS dual symbol

Equations

  1. Eq. 2.2-2: Cu = D60 / D10
  2. Eq. 2.2-3: Cc = D30² / (D10 D60) — SW: Cu ≥ 6 and 1 ≤ Cc ≤ 3

Steps

Step 1 · Cu
0.090 / 0.003
Cu = 30.0 ≥ 6: passes
↓
Step 2 · Cc
0.019² / (0.003 × 0.090) = 0.000361 / 0.000270
Cc = 1.34, between 1 and 3: passes
Spot check: The units cancel, so the ratio can be taken in inches without converting.
↓
Step 3 · Dual symbol
Well graded; fines 9% (5 to 12%); NP
SW-SM
↓
Solution
SW-SM, well-graded sand with silt.

Solution

Cu = 30.0 and Cc = 1.34; the sand is well graded. With 9% non-plastic fines it is SW-SM, well-graded sand with silt.

SW-SM is generally a suitable subgrade material. Its performance depends on compaction, so density is verified during construction (Chapter 5.3).

Question 2.2-3: Correcting Vane Shear Strength and Screening Activity

Problem Statement

A railroad embankment over soft plastic clay is to be checked for stability before a speed increase. Field vane tests gave the strength shown, and laboratory tests gave the plasticity index and clay fraction. The engineer must correct the vane strength for use in the stability analysis and screen the clay for swell potential.

Field vane shear tests overestimate the strength of plastic clays mobilized in an embankment failure, so the vane value is reduced by Bjerrum’s factor. The same sample’s activity screens it for swell.

Soft plastic claysu,VST = 0.22 tsf0204060800.60.81.00.850.75μ at PI 48 = ?Plasticity index, PI (%)Bjerrum correction μGivenPI = 48%Clay fraction 35%(finer than 0.002 mm)Required(a) Corrected su(b) Activity ABlack = given; red = required
Given and required for Question 2.2-3: field vane strength and Bjerrum correction.

Given

VariableValueDescription
su,VST0.22 tsfField vane shear strength
PI48%Plasticity index
Clay fraction35%Percent finer than 0.002 mm
μ0.85 at PI = 40%; 0.75 at PI = 60%Bjerrum correction factors read from the chart

Required

  • (a) Corrected undrained strength
  • (b) Activity and what it indicates

Equations

  1. Eq. 1: μ = μ60 + (60 − PI)/(60 − 40) × (μ40 − μ60) — linear interpolation of Bjerrum’s factor
  2. Eq. 2: su = μ su,VST — corrected strength
  3. Eq. 3 (Eq. 2.2-7): A = PI / (% finer than 0.002 mm) — Skempton’s activity

Steps

Step 1 · μ at PI = 48% (Eq. 1)
0.75 + (12 / 20) × 0.10 = 0.75 + 0.06
μ = 0.81
Spot check: 0.81 lies between 0.75 and 0.85 and nearer 0.85, since 48 is nearer 40.
↓
Step 2 · Corrected su (Eq. 2)
Uses: μ, su,VST
0.81 × 0.22 tsf = 0.178 tsf
su = 0.178 tsf = 356 psf
Spot check: 1 tsf = 2,000 psf; 0.178 × 2,000 = 356.
↓
Step 3 · Activity (Eq. 3)
A = 48 / 35
A = 1.37: active clay
Spot check: A above 1.25 is classed active; smectite (montmorillonite) is likely.
↓
Solution
(a) su = 356 psf; (b) A = 1.37, active.

Solution

(a) Corrected su = 0.178 tsf (356 psf). (b) A = 1.37, an active clay.

Using the uncorrected vane value would overstate the strength by about 19%. The activity says the clay mineral is probably smectite, so swell testing (ASTM D4546) is warranted before the subgrade or any structure is designed. Both the corrected strength and the swell data belong in the geotechnical report (Chapter 8.4).

Question 2.2-4: Rock Mass Rating for a Tunnel

Problem Statement

A passenger rail corridor is studying a short tunnel to replace a sharp curve around a ridge. A 10-ft core run from the feasibility boring gave the rock strength, RQD, joint spacing and condition shown, in a dry hole with joints favorably oriented for tunneling. The engineer must compute the rock mass rating and class for the tunnel feasibility report.

A 10-ft core run from a tunnel feasibility study on a passenger corridor. The same six RMR ratings are used as for a slope, but the orientation adjustment is taken from the table for tunnels.

Tunnels = 1.5 ftRMR and class = ?GivenUCS = 22,000 psi (152 MPa)RQD = 74% (10-ft core run)Joint spacing s = 1.5 ftSlightly rough, no infill, unweatheredDry boreholeOrientation favorable for tunnelingRequiredRMRRock mass classBlack = given; red = required
Given and required for Question 2.2-4.

Given

VariableValueDescription
UCS22,000 psi (152 MPa)Uniaxial compressive strength
RQD74%Rock quality designation
s1.5 ft (457 mm)Average joint spacing
ConditionSlightly rough, no infill, unweatheredJoint condition
WaterDry boreholeGroundwater
OrientationFavorable for tunnelingJoint orientation

Required

  • RMR and rock mass class

Equations

  1. Eq. 2.2-12: RMR = R1 + R2 + R3 + R4 + R5 + R6 — Bieniawski (1989); R6 for tunnels

Steps

Step 1 · R1
152 MPa is in the 100–250 MPa band
12
↓
Step 2 · R2
74% is in the 50–75% band
13
↓
Step 3 · R3
457 mm is in the 200–600 mm band
10
↓
Step 4 · R4
Slightly rough, tight, unweathered
25
↓
Step 5 · R5
Dry
15
↓
Step 6 · R6
Favorable for tunnels
−2
↓
Step 7 · RMR
12 + 13 + 10 + 25 + 15 − 2
RMR = 73: Class II, good rock
Spot check: Class II spans 61 to 80.
↓
Solution
RMR = 73, Class II, good rock.

Solution

RMR = 73, Class II (good rock).

For a tunnel the orientation adjustment is small when the joints are favorable, so the rating is governed by the rock itself. If the owner’s criterion for unsupported spans is, say, RMR of 60 or more, this rock meets it. A Q-system check is still recommended before tunnel support recommendations are finalized, because the two systems weigh joint sets and stress differently.

Question 2.2-5: Frost Susceptibility of a Silt Subgrade

Problem Statement

A Class I railroad located in Manitoba is rebuilding a main track that heaves every winter. The subgrade is a silt with the fines content shown, in a climate with deep seasonal frost. The engineer must assign the frost susceptibility group and explain what it means for the depth of non-frost-susceptible material above the subgrade.

A subgrade sample from a Class I railroad located in Manitoba. Frost susceptibility is assigned from the soil type and the percentage finer than 0.02 mm, and it decides how much non-frost-susceptible material must sit above the subgrade.

ML silt subgrade: 18% finer than 0.02 mmTrackBallast and subballastDeep seasonal frost (about 50°N)ice lensesFrost group = ? NFS thickness = ?GivenUSCS ML (silt)18% finer than 0.02 mmAbout 50°N, deep frostTrack heaves every winterRequiredUSACE frost groupImplication for NFS layerabove the subgradeBlack = given; red = required
Given and required for Question 2.2-5.

Given

VariableValueDescription
USCSMLSilt
% finer than 0.02 mm18%Fines in the frost-critical size range
ClimateAbout 50°NDeep seasonal frost

Required

  • USACE frost group
  • Practical implication for track design

Equations

No equation is needed; the answer follows from the criteria listed under Given.

Steps

Step 1 · Is the soil frost-susceptible?
18% finer than 0.02 mm > 3%
Yes
↓
Step 2 · Which group?
All silts (ML, MH) are grouped F4 once they are frost-susceptible
F4, the most frost-susceptible group
↓
Step 3 · What does design need?
Freezing index for the site; a non-frost-susceptible granular layer over the subgrade, thick enough for the freeze depth; geometry monitoring after construction.
↓
Solution
F4: provide non-frost-susceptible cover sized by a freeze-depth calculation.

Solution

USACE group F4, the most frost-susceptible group.

Silt with water available is the material that heaves most and loses most strength on thaw (Section 3.8.8). Document the frost group in the geotechnical data report, determine the site freezing index, and provide a non-frost-susceptible (NFS) granular subballast over the subgrade with its thickness set by a site-specific freeze-depth calculation, such as the modified Berggren equation (Chapter 7.3). Track geometry should be monitored (Chapter 5.3) through the first few freeze-thaw cycles after construction.

Empirical equation note · this section

Values from these correlations are estimates, not test results. State the equation ID and source when one is used, confirm the soil or rock is within its range, and calibrate against site testing before design.

  • IS-25 Field vane strength correction Sᵤ (field)Use: Soft clays, embankment stability on soft ground; based on back-analyzed failures. Typical PI 5–100%. Limits: Not applicable to fissured, varved, or organic clays without local calibration. Scatter about ±25%.
  • IX-10 Undrained strength from liquidity index Sᵤ (remolded)Use: Remolded clays; anchored at Su ≈ 35 psf at LL and ≈ 3,550 psf at PL. Limits: Remolded strength only; intact strength is higher by the sensitivity. Rough estimate.
  • RK-01 Rock Mass Rating (RMR₈₉) RMRUse: Jointed rock masses; tunnels, foundations; slopes via SMR (RK-06). Limits: Mixed versions (1976 vs 1989) give different values; state which is used.
  • RK-02 Rock mass quality (Q-system) QUse: Underground excavations; range 0.001–1000. Limits: Developed for tunnels; SRF and Jw are not directly meaningful for slopes. Use RQD ≥ 10 in calculation.
← Previous · 2.0 The Underworld Chapter 2.1 — Track Foundation Elements
Next · 2.0 The Underworld → Chapter 2.3 — Track Substructure: Ballast, Subballast and Subgrade